• Title/Summary/Keyword: A photovoltaic system

Search Result 1,625, Processing Time 0.029 seconds

Properties of ZnO:Al thin film on variation of substrate temperature for display application

  • Keum, M.J.;Kim, H.W.;Cho, B.J.;Son, I.H.;Choi, M.G.;Lee, W.J.;Jang, K.W.;Kim, K.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1474-1476
    • /
    • 2005
  • ZnO:Al(AZO) has been investigated for the photovoltaic cell or TCO(Transparent Conductive Oxide) of the display, because it has good electrical and optical properties. In this study, the ZnO:Al(AZO) thin film prepared on variation of substrate temperature by FTS(Facing Targets Sputtering) system. In case of TCO, because resistivity and roughness values affect the lighting of the OLED, their factors are very important. Therefore, in this paper, the electrical and optical properties of the AZO thin film were investigated with the deposition conditions and its roughness was investigated on variation of the substrate temperature. In results, AZO thin film deposited with the transmittance over 80% and the resistivity was reduced from $1.36{\times}10^{-3}$ [O-cm] to $4{\times}10^{-4}$ [O-cm] with increasing the substrate temperature from R.T to $200[^{\circ}C]$. Especially, we could obtain the resistivity $4{\times}10^{-4}$ [O-cm] of AZO thin film prepared at working pressure 1[mTorr], input current 0.4[A] and substrate temperature $200[^{\circ}C]$.

  • PDF

Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop (Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구)

  • Lee, K.O.;Choi, J.Y.;Choy, I.;Jung, Y.S.;Yu, G.Y.;Song, S.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

A Study on the Remote Control of Photovoltaic/Solar Heating System according to Seasonal and Regional (계절 및 지역적 특성을 고려한 태양광발전 태양열시스템의 원격제어에 관한 연구)

  • Yoon H.S.;Kang B.B.;Lim J.Y.;Yoon P.H.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.938-941
    • /
    • 2003
  • 본 시스템은 나주 생물자원산업화센터에 설치된 태양광 및 태양열 시스템에 대한 운전결과특성으로써 특용작물배양의 전원 및 온수공급을 위한 것이다 태양광발전은 10kWP이고, 태양열시스템은 500l 로 구성되어 있다. 태양광발전시스템의 인버터는 10kW급 계통연계형으로써 상용전원과 연계해서 사용할 수 있도록 하였으며 태양열시스템은 생물자원산업화센터의 실험용 급탕으로 사용된다. 본 논문에서는 태양광발전과 태양열시스템이 설치된 생물자원산업화센터에 상주 근무인원을 대체하기 위해서 원격 모니터링 시스템을 구성하였고, 모니터링에 의해 축적된 데이터를 통해 그 특성을 비교하고자 한다.

  • PDF

Anti-Reflection Thin Film For Photoelectric Conversion Efficiency Enhanced of Dye-Sensitized Solar Cells (염료감응형 태양전지의 광전변환효율 향상을 위한 무반사 박막)

  • Jung, Haeng-Yun;Ki, Hyun-Chul;Hong, Kyung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.12
    • /
    • pp.814-818
    • /
    • 2016
  • DSSCs (dye-sensitized solar cells) based on $TiO_2/SiO_2$ multi layer AR (anti-reflection) coating on the outer glass FTO (fluorine-doped tin oxide) substrate are investigated. We have coated an AR layer on the surface of a DSSCs device by using an IAD (ion beam-assisted deposition) system and investigated the effects of the AR layer by measuring photovoltaic performance. Compared to the pure FTO substrate, the multi layer AR coating increased the total transmittance from 67.4 to 72.9% at 530 nm of wavelength. The main enhancement of solar conversion efficiency is attributed to the reduction of light reflection at the FTO substrate surface. This leads to the increase of Jsc and the efficiency improvement of DSSCs.

Research of DC-DC Converter for Ocean Buoy (해상용 브이에 적합한 DC-DC 컨버터 연구)

  • Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.839-844
    • /
    • 2007
  • This paper describes the performance of DC-DC converters for buoy such as buck, boost, and buck-boost. The operating characteristic and charging efficiency with battery, which has a considerable properties about converters with PV(photovoltaic) system, is analyzed in this paper. It is performed by using the MPPT(Maximum Power Point Tracker) algorithm The basic equations of switching operation for converter are described, and the equations are analyzed with according to switch state. Whereas this analysis is directed toward the selection of converter for buoy, it also provides the insight into the behaviour of converter and performance of the proposed algorithm Finally, the suitable DC-DC converter is proposed for buoy, and the characteristic experiment is performed with the buck converter.

An Experimental Study of Performance Improvement of Air Type PV/T Collector Units (실험에 의한 공기식 태양광·열 복합 유닛의 성능 비교)

  • Kim, Jin-Hee;Yang, Yeon-Won;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.7 no.6
    • /
    • pp.17-22
    • /
    • 2007
  • The integration of PV modules into building facades or roof could raise their temperature that results in the reduction of PV system's electrical power generation. Hot air can be extracted from the space between PV modules and building envelope, and used for heating in buildings. The extraction of hot air from the space will enhance the performance of BIPV systems. The solar collector utilizing these two aspects is called PV/T(photovoltaic/thermal) solar collector. This paper compares the experimental performance of two different types of air type PV/T collector units: the base case of a collector unit with 10cm gap for forced ventilation and the other unit with copper pin attached to PV module to enhance its thermal performance. The experimental results shows that the base case unit had the overall efficiency of 41.9% and the improved unit with copper pin attached to PV module had 50.1% efficiency. For these air type PV/T units, the forced ventilation of the air space improved the electrical performance as well as the thermal performance.

Active Frequency Drift Positive Feedback Method for Anti-islanding (단독운전검출을 위한 능동적 주파수 변화 정궤환기법)

  • So, J.H.;Jung, Y.S.;Yu, G.J.;Yu, B.G.;Lee, K.O.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1684-1686
    • /
    • 2005
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop(DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment in IEEE Std 929-2000 islanding test.

  • PDF

A Single-Source Photovoltaic Power Conditioning System using Forward-Flyback converter and Asymmetric cascaded Multi Level H-bridge Inverter (포워드-플라이백 컨버터와 단일 전원 비대칭 다단식 H-bridge 다중 레벨 인버터를 적용한 태양광 전력 조절 시스템)

  • Jeon, Young-tae;Sundar, Mohana;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.73-74
    • /
    • 2016
  • 본 논문은 포워드-플라이백 컨버터와 태양광 단일 전원 비대칭 다단식 H-bridge 다중 레벨 인버터를 적용한 태양광 전력 조절 시스템에 관한 논문이다. 이는 기존에 연구되었던 대칭형 다단식 H-Brdige 다중 레벨 인버터나 플라이백 컨버터를 사용한 태양광 전력 조절 시스템의 단점을 보완 한 것이다. 대칭형 다단식 멀티 레벨 인버터는 각 H-Bridge 구조 마다 독립된 전원이 필요하지만, 포워드-플라이백(Foward-Flyback) 컨버터를 접목시켜 단일 태양광 전원으로 하나의 다단식 H-Brdige 인버터를 구성 할 수 있고, 또한 기존의 플라이백 컨버터를 포워드-플라이백 컨버터로 대체 하면서 기존 대비 대용량 설비가 용이하고 효율적인 태양광 전력 조절 시스템을 설계 할 수 있다. 제안한 시스템의 가능성을 확인하기 위하여, PSIM 시뮬레이션을 통해 계통 연계형 1kW급 태양광 시스템의 최대 전력 추종 제어(Maximum Power Point Tracking)와 인버터의 $V_{dc}$ 전압 제어를 확인하였다.

  • PDF

Temperature Control for PV Panel Absorbing Heat by Phase Change Material and its Estimation (상변환물질을 활용한 태양광 패널 표면온도 제어효과 및 최적화 시스템)

  • Lee, Hyo-Jin;Chun, Jong-Han
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.10-15
    • /
    • 2010
  • The experimental study was conducted to optimize the system dissipating properly heat from the in-situ solar panel installed on the roof. For this purpose, six 12-Watt panels, which were consisted of the different design conditions such as containing phase change material(PCM), changing the array of the aluminum fin and honeycomb at the back of the panel, were tested. PCM, which had $44^{\circ}C$ melting point, was chosen in this study. In order to enhance absorbing and expelling heatin PCM, profiled aluminum fin was placed either inward oroutward from the panel. Furthermore, Aluminum honeycomb is imbedded in the back container to find if it would improve the thermal conductivity of PCM. During the experiment, there were ranged to $26^{\circ}C\sim32^{\circ}C$ for outdoor temperature and $700W/m^2\sim1000W/m^2$ for irradiance. As a result, the solar panel, combined with honeycomb and outward fins with PCM instead of placing the fins inward, is showing the best performance in terms of controling panel temperature and its efficiency.

A Study on Design for Energy-saving Based on Analysis of Current Situation in School Facilities (학교시설 현황분석을 통한 에너지절약설계 개선방향 연구)

  • Meang, Joon-Ho;Kim, Sung-Joong;Lee, Seung-Min;Ko, Hyun-Su
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.17 no.3
    • /
    • pp.1-8
    • /
    • 2018
  • We suggest improvement direction of energy-saving design based on analysis of current situation in school facilities. School facilities have large area among public buildings. While the number of students is decreasing, the number of school and energy consumption is increasing year after year. School facilities have excellent heat insulation property, but it requires further examination about excessive heat insulation plan. School facilities are using gas heat pump actively for cooling and heating, but has difference in use ratio of ground source heat pump by region. Thus School facilities requires active using of ground source heat pump and BIPV(Building Integrated Photovoltaic System).