• 제목/요약/키워드: A photovoltaic system

검색결과 1,629건 처리시간 0.046초

제주도 지역별 대용량 태양광발전소들의 여름 피크타임 기여도 연구 (Contribution of Large-Scale PV Plants in the Respective Region of the Jeju Island to Electric Power during Summer Peak Times)

  • ;고석영;사공준;권훈;이개명
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1873-1878
    • /
    • 2017
  • Both the introduction of the Renewable Energy Portfolio Standard (RPS) system into the electric energy market in 2012 and a decrease in the cost of constructing photovoltaic (PV) power plants have been increasing the number of MW PV plants in South Korea. Jeju Island is located at the center of three nations, South Korea, China and Japan, and its provincial government declared in 2012 that the island will be a clean region where greenhouse gases are not emitted by 2030. The Jeju provincial government is now doing its best to install PV plants and wind farms to realize a carbon-free island. In this study we investigated contribution of MW PV plants to the power of the electric grid during summer peak times on Jeju Island. Mt. Halla the highest mountain in South Korea, is located at the center of Jeju Island, and we divided the island into four regions and carried out analyses of a total of 24 PV plants. The average contribution of the PV plants in the respective region to electric power of Jeju Island during summer peak times was investigated and compared with those of the other regions. The best average contribution during the 12.5% maximum load period was obtained from the PV plants in the western region, and the value was 33% during 2015 and 2016.

반고정식 PV 시스템의 운영 스케줄 도출 및 그에 따른 발전 효율 변화 고찰 (Optimal Operation Schedule of Semi-Fixed PV System and Its Effect on PV Power Generation Efficiency)

  • 곽인규;문선혜;허정호
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.69-77
    • /
    • 2017
  • The amount of solar irradiation obtained by a photovoltaic (PV) solar panel is the major factor determining the power generated by a PV system, and the array tilt angle is critical for maximizing panel radiation acquisition. There are three types of PV systems based on the manner of setting the array tilt angle: fixed, semi-fixed, and tracking systems. A fixed system cannot respond to seasonal solar altitude angle changes, and therefore cannot absorb the maximum available solar radiation. The tracking system continually adjusts the tilt angle to absorb the maximum available radiation, but requires additional cost for equipment, installation, operation, and maintenance. The semi-fixed system is only adjusted periodically (usually seasonally) to obtain more energy than a fixed system at an overall cost that is less than a tracking system. To maximize semi-fixed system efficiency, determining the optimal tilt angle adjustment schedule are required. In this research, we conducted a simulation to derive an optimal operation schedule for a semi-fixed system in Seoul, Korea (latitude $37.5^{\circ}$). We implemented a solar radiation acquisition model and PV genereation model on MATLAB. The optimal operation schedule was derived by changing the number of tilt angle adjustments throughout a year using a Dynamic Algorithm. The results show that adjusting the tilt angle 4 times a year was the most appropriate. and then, generation amount of PV system increased 2.80% compared with the fixed system. This corresponds to 99% compared to daily adjustment model. This increase would be quite valid as the PV system installation area increased.

외피의 Passive Design 요소와 신재생에너지를 적용한 생물안전 밀폐시설의 에너지 시스템 개선방안 연구 (A Study on the Energy Improvement Plan of using Passive Design with Exterior Envelopes and Renewable Energy for Bio Safety Labotratory)

  • 황지현;범도;홍진관
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.491-496
    • /
    • 2014
  • In general, the entire air supply of a bio-safety laboratory (BSL) should be exhausted on the outside to ensure bio-safety, and the air conditioning system should always be operated to maintain a difference in the room pressure. As a result, the annual energy consumption of such a building is approximately five or ten times higher than that of an office building of the same magnitude. Thus, this study applies an actual operating system that targets BSL. The energy consumption is analyzed using the Energy Plus V8.0 program (an energy analysis program), and five kinds of cases that depend on the energy consumption of the basic BSL system are also analyzed. As a result, the energy consumption in Case 1 (basic system) is of 324.95 GJ. When the basic system of Case 1 is compared to that in Case 2 (basic system+passive design with exterior envelopes), an annual energy savings of is 6.9% is achieved. For Case 3 (basic system+Photovoltaic, PV) 12.7% is achieved, and for Case 4 (Solar Geothermal Hybrid System of renewable energy, SGHS) 49.5% is achieved. If a passive design with exterior envelopes and renewable energy system (PV+SGHS) is combined, as in Case 5, the energy consumption would be 118.15 GJ. Therefore, when this last system is compared to a basic system, the passive design with exterior envelopes and renewable energy system (PV+SGHS) can reduce energy consumption by 63.6%.

A Photovoltaic Power Management System using a Luminance-Controlled Oscillator for USN Applications

  • Jeong, Ji-Eun;Bae, Jun-Han;Lee, Jinwoong;Lee, Caroline Sunyong;Chun, Jung-Hoon;Kwon, Kee-Won
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권1호
    • /
    • pp.48-57
    • /
    • 2013
  • This paper presents a power management system of the dye-sensitized solar cell (DSSC) for ubiquitous sensor network (USN) applications. The charge pump with a luminance-controlled oscillator regulates the load impedance of the DSSC to track the maximum power point (MPP) under various light intensities. The low drop-out regulator with a hysteresis comparator supplies intermittent power pulses that are wide enough for USN to communicate with a host transponder even under dim light conditions. With MPP tracking, approximately 50% more power is harvested over a wide range of light intensity. The power management system fabricated using $0.13{\mu}m$ CMOS technology works with DSSC to provide power pulses of $36{\mu}A$. The duration of pulses is almost constant around $80{\mu}s$ (6.5 nJ/pulse), while the pulse spacing is inversely proportional to the light intensity.

태양광발전 저압연계시 인버터 출력단 전압상승에 대한 연구 (A study on the voltage rise of the inverter output terminal according to the low voltage Grid connection of solar power generation)

  • 조강연;어익수
    • 한국산학기술학회논문지
    • /
    • 제21권11호
    • /
    • pp.746-752
    • /
    • 2020
  • 환경문제가 세계적으로 심각하게 다뤄지면서 우리나라도 태양광발전 설비가 급속도로 증가하였다. 특히 소용량 태양광발전을 저압배전으로 연계하는 계통에서 인버터 출력단의 전압상승으로 인하여 저압배전계통 품질저하 및 부하설비에 악영향을 주고 있다. 또한 과전압에 의한 인버터 가동중지로 인하여 발전소의 경제적 손실을 줄 수 있다. 본 논문에서는 저압배전계통 연계에 따른 태양광 인버터 출력단 전압 상승 해결방안을 연구 하였다. 첫째, 역률제어 및 능동전압제어 인버터를 사용하여 무효전력을 제어하면 출력단 전압이 230.91V에서 208.99V로 단자전압 비율이 약 10%가 내려갔다. 둘째, 배전전압용 변압기 2차 Tap을 조정하면 약 15V의 전압조정이 가능하지만, 한전배전규정전압이 220±13V의 범위가 벗어나지 않는 한 Tap을 조정해 주지 않는 문제점이 있다. 셋째, 인버터의 댓 수를 제한하면 인버터 과전압 범위 안에서 인버터를 기동할 수 있다. 넷째, 단상이 아닌 삼상으로 연계하면 전압이 분배되어 전압상승을 방지 할 수 있다. 4가지 중 현장 적용이 용이한 것은 역률제어 및 능동전압제어 인버터를 사용하는 것임을 확인하였다.

Investigation of Instability in Multiple Grid-Connected Inverters with LCL Output Filters

  • Asghari, Fariba;Safavizadeh, Arash;Karshenas, Hamid Reza
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.757-765
    • /
    • 2018
  • This paper deals with the instability and resonant phenomena in distribution systems with multiple grid-connected inverters with an LCL output filter. The penetration of roof-top and other types of small photovoltaic (PV) grid-connected systems is rapidly increasing in distribution grids due to the attractive incentives set forth by different governments. When the number of such grid-connected inverters increases, their interaction with the distribution grid may cause undesirable effects such as instability and resonance. In this paper, a grid system with several grid-connected inverters is studied. Since proportional-resonant (PR) controllers are becoming more popular, it is assumed that most inverters use this type of controller. An LCL filter is also considered at the inverters output to make the case as realistic as possible. A complete modeling of this system is presented. Consequently, it is shown that such a system is prone to instability due to the interactions of the inverter controllers. A modification of PR controllers is presented where the output capacitor is virtually decreased. As a result, the instability is avoided. Simulation results are presented and show a good agreement with the theoretical studies. Experimental results obtained on a laboratory setup show the validity of the analysis.

독립형 풍력기반 Smart Microgrid 시스템의 현장 실증 시험을 위한 도서지역 전력 및 경제성 시뮬레이션 (Power and Economic Simulation of Island for the Field Demonstration Test of Smart Microgrid System Based on Stand-alone Wind power)

  • 강상균;이은규;이장호
    • 신재생에너지
    • /
    • 제10권3호
    • /
    • pp.22-30
    • /
    • 2014
  • The isolated self-generating electricity with diesel engine generator has been used in islands far away from main land. It costs high because of increasing oil price, and unsafe to have supplying oil and its related components by ship due to unexpectable marine conditions. Therefore there is the need for the hybrid system of renewable energy like wind or solar energy systems with oil engine generator, which can reduce oil use and extend oil supplying period. In this study, the feasibility of such hybrid system with smart micro grid on the eight islands of Jeon-nam province is surveyed to find good place for the demonstration test of the hybrid system. In each island, 3 wind turbine systems of 10 kW and photovoltaic of 20 kW are tested with already installed diesel engine. The performance and costs of the hybrid system in each island are compared in the given conditions of solar and wind energy potential. As a result of the study, Jung-ma island is recommended for the optimum place to make real field demonstration test of isolated hybrid generating and smart grid systems.

PSA 알고리즘에 의한 태양광 추적시스템의 효율분석 (Efficiency Analysis of PV Tracking System with PSA Algorithm)

  • 최정식;고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.36-44
    • /
    • 2009
  • 본 논문에서는 PSA(position solar algorithm)을 이용하여 태양광 추적시스템의 발전 효율을 분석하였다. 태양의 위치 추적시스템은 자연환경 조건에 무관한 태양광 발전시스템에 매우 효과적으로 필요하다. 프로그램 방식의 태양광 추적시스템은 구름이나 대기 조건에 의해 일사량이 급하게 변할 경우에도 오동작 없이 정확하게 태양을 추적을 할 수 있다. 따라서, 본 논문에서는 더욱 정확하게 태양의 위치를 추적하기 위한 PSA 알고리즘을 제시하고, 제시한 알고리즘을 이용하여 태양광 발전시스템의 효율을 분석한다. 또한 적용된 알고리즘에 의해 제어된 고도각 및 방위각을 한국 천문연구원에서 제공된 데이터와 비교한다. 본 논문에서는 고도각 및 방위각 제어의 오차와 적용된 알고리즘의 발전효율을 분석하고 결과를 통하여 적용된 알고리즘의 타당성을 입증한다.

방재 및 감재주택을 위한 건축 계획 요소의 설정 (Architectural Design Elements for Hazard-Resistant and Reduction House)

  • 김형언
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: Almost every research carried out in our country against the natural disaster is focused on the temporary facilities such as temporary housing, emergency shelter and as a result, it is very hard to find out researches on the ordinary houses which installed integrated systems of hazard-resistant against the natural disaster. Method: To conduct this research, categorizing process for design, structural, environmental and installation elements found in the Hazard-Resistant and Reduction House built for sale in Japan was performed. Result: In this study, several design concepts and subordinate items are recommended for hazard-resistant housing. First, design concept of 'Preparedness' which means security and access to the storage storing goods especially food & beverage for the emergencies is needed. The subordinate items consist of security of stocking space, diversified and circular storage system, and safety storage system. Second, design concept of 'Security' which means security of physical safety space and rapid recovery to returning to daily life against natural disaster is needed. The subordinate items consist of many items including not only structure and facilities but also architectural design method. And finally, design concept of 'Maintenance, Support and Return' which means minimizing the physical and psychological damages and support safety and physical conditions of the victims from the impact of the disaster to returning to daily life is needed. The subordinate items consist of high efficiency insulation/airtightness design, microclimate design, combination of photovoltaic system and storage battery, non-power appliance system against the power failure, storing system for drinking water, rainwater storing and utilization system.

LabVIEW와 DSP를 이용한 초저가 범용 태양광 발전시스템 VI-Tracer 개발 (Development of a Low Cost VI-Tracer for PV System using LabVIEW and DSP)

  • 김상용;박상수;장성재;김경훈;서효룡;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1049_1050
    • /
    • 2009
  • This paper deals with development of a low cost VI(Voltage-Currrent)-tracer for PV(Photovoltaic) system using LabVIEW and DSP(Digital Signal Processor). Although the conventional VI-tracer is a high cost equipment, it can‘t abstract the detailed parameters of solar cell. To overcome above mentioned disadvantages, in this paper, a converter type VI-tracer is developed. The DSP, which controls the buck-boost DC-DC converter, is used to implement the proposed VI-tracer algorithm. The proposed VI-tracer can abstract more detailed parameters of solar cell; A(temperature constant), Rs(series resistance), and Rsh(parallel resistance). The authors emphasize that the proposed VI-tracer can satisfy the users who need to get various parameters. A comparison between the proposed VI-tracer and the conventional VI-tracer is presented to show the effectiveness of the proposed system.

  • PDF