• Title/Summary/Keyword: A Scale of 1:1000

Search Result 138, Processing Time 0.029 seconds

Assessing the Positioning Accuracy of High density Point Clouds produced from Rotary Wing Quadrocopter Unmanned Aerial System based Imagery (회전익 UAS 영상기반 고밀도 측점자료의 위치 정확도 평가)

  • Lee, Yong Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.39-48
    • /
    • 2015
  • Lately, Unmanned Aerial Vehicles(UAV), Unmanned Aerial Systems(UAS) or also often known as drones, as a data acquisition platform and as a measurement instrument are becoming attractive for many photogrammetric surveying applications, especially generation of the high density point clouds(HDPC). This paper presents the performance evaluation of a low-cost rotary wing quadrocopter UAS for generation of the HDPC in a test bed environment. Its performance was assessed by comparing the coordinates of UAS based HDPC to the results of Network RTK GNSS surveying with 62 ground check points. The results indicate that the position RMSE of the check points are ${\sigma}_H={\pm}0.102m$ in Horizonatal plane, and ${\sigma}_V={\pm}0.209m$ in vertical, and the maxium deviation of Elevation was 0.570m within block area of ortho-photo mosaic. Therefore the required level of accuracy at NGII for production of ortho-images mosaic at a scale of 1:1000 was reached, UAS based imagery was found to make use of it to update scale 1:1000 map. And also, since this results are less than or equal to the required level in working rule agreement for airborne laser scanning surveying of NGII for Digital Elevation Model generation of grids $1m{\times}1m$ and 1:1000 scale, could be applied with production of topographic map and ortho-image mosaic at a scale of 1:1000~1:2500 over small-scale areas.

SIMULATED AP1000 RESPONSE TO DESIGN BASIS SMALL-BREAK LOCA EVENTS IN APEX-1000 TEST FACILITY

  • Wright, R.F.
    • Nuclear Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.287-298
    • /
    • 2007
  • As part of the $AP1000^{TM}$ pressurized water reactor design certification program, a series of integral systems tests of the nuclear steam supply system was performed at the APEX-1000 test facility at Oregon State University. These tests provided data necessary to validate Westinghouse safety analysis computer codes for AP1000 applications. In addition, the tests provided the opportunity to investigate the thermal-hydraulic phenomena expected to be important in AP1000 small-break loss of coolant accidents (SBLOCAs). The APEX-1000 facility is a 1/4-scale pressure and 1/4-scale height simulation of the AP1000 nuclear steam supply system and passive safety features. A series of eleven tests was performed in the APEX-1000 facility as part of a U.S. Department of Energy contract. In all, four SBLOCA tests representing a spectrum of break sizes and locations were simulated along with tests to study specific phenomena of interest. The focus of this paper is the SBLOCA tests. The key thermal-hydraulic phenomena simulated in the APEX-1000 tests, and the performance and interactions of the passive safety-related systems that can be investigated through the APEX-1000 facility, are emphasized. The APEX-1000 tests demonstrate that the AP1000 passive safety-related systems successfully combine to provide a continuous removal of core decay heat and the reactor core remains covered with considerable margin for all small-break LOCA events.

A Study on the Consecutive Renewal of Road and Building Information in the Multi-scale Digital Maps (다축척 수치지도의 도로 및 건물정보 일괄갱신 연구)

  • Park, Kyeong-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.1
    • /
    • pp.21-28
    • /
    • 2011
  • In the existing digital map of the Ver.1.0, it is impossible to make a small scale digital map, which is under the 1/5000 scale map, by using the 1/1000 digital map which is the most large scale one. Because of this reason, the existing digital maps are produced into a 1/1000 and a 1/5000 map by means of two different scale aerial photos. The next generation digital map should be successively related to a small scale digital map based on the most large scale digital one. This is so important from the aspects of data share and the consecutive renewal. Ever since the development of the digital map of the Ver. 2.0, the possibility of making a multi-scale consecutive digital map has been presented and the related research has been done again. The most basic thing in the multi-scale digital maps is to decide the criteria of the generalization between the two scales. In this study, I try to formulate the criteria of the generalization required to make the 1/5000 digital map by using the 111000 digital one. In addition, I by to explore the application possibility of the consecutive renewal by carrying out auto-generalization.

소수력 발전에 대하여

    • Journal of the Korean Professional Engineers Association
    • /
    • v.15 no.1
    • /
    • pp.32-35
    • /
    • 1982
  • The sudden shock of repeated oil crisis and the subsequent violent increases in petroleum prices have given rise to an intensive worldwide effort to develop alternate sources of clean energy. Against this background, a great deal of attention has recently come to be focused on mini-scale hydroelectric power turbine generation. There is now a strong demand for the development of a hydroelectric generator suitable for generating power on a small scale and copable of overcoming the high per kilowatt cost of conventional one's then Francis turbine. Hence was accordingly developed the "Cross flowturbine generator" of 1000kw and less, which we call. This mimi-scale water turbine is reliably and easily handled and also can be economicaly manufactored in a range with effective head of over 3meter's a flow rate of minimum 30 liter per sec and an output of below 1000kw good's.kw good's.

  • PDF

High Temperature Oxidation of Ti-6Al-4V, Ti-4Fe, Ti-(1,2)Si Alloys (Ti-6Al-4V, Ti-4Fe, Ti-(1,2)Si합금의 고온산화)

  • 박기범;이동복
    • Journal of the Korean institute of surface engineering
    • /
    • v.34 no.2
    • /
    • pp.135-141
    • /
    • 2001
  • Arc-melted Ti-6Al-4V, Ti-4Fe and Ti-(1,2) Si alloys were oxidized at 700, 800, 900 and $1000^{\circ}C$ in air. The oxidation resistance of Ti-4Fe was comparable to that of Ti-6Al-4V, while the oxidation resistance of Ti-(1,2) Si was superior to that of Ti-6Al-4V. Ti-2Si displayed the best oxidation resistance among the four alloys, but failed after oxidation at $1000^{\circ}C$ for 17h. The oxide scale formed on Ti-6Al-4V, Ti-4Fe and Ti-(1,2)Si consisted of ($TiO_2$ and a small amount of $Al_2$$O_3$), ($TiO_2$ and a small amount of dissolved iron), and ($TiO_2$ plus a small concentration of amorphous $SiO_2$), respectively. The oxide grains of the surface scale of the four alloys were generally fine and round.

  • PDF

Comparison of Unconfined and Confined Micro-scale Impinging Jets

  • Choo, Kyo-Sung;Youn, Young-Jik;Kim, Sung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2210-2213
    • /
    • 2008
  • In the present study, effects of degree of confinement on heat transfer characteristics of a micro-scale slot jet impinging on a heated flat plate are experimentally investigated. The effects of Reynolds numbers (Re = $1000{\sim}5000$), lateral distances (x/B = $1{\sim}10$), nozzle-to-plate spacings (Z/B = $1{\sim}20$), and degree of confinement ($B_c$/B = 3, 48) on the Nusselt number are considered. The results show that the effects of the degree of confinement on the cooling performance of the micro-scale impinging slot jet are significant at lower nozzle-to-plate spacings and higher Reynolds numbers. In addition, it is shown that the cooling performance of the micro-scale unconfined slot impinging jet is 200% higher than that of the micro-scale confined slot impinging jet.

  • PDF

Characteristics of LED Signal Lamp Driving by SMPS for Large-scale Traffic Signal (SMPS 구동 대형교통 신호용 LED 신호등의 특성)

  • Shin, Hyun-Yong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.643-648
    • /
    • 2011
  • In this study, SMPS driven LED traffic signal light for Large-scale traffic such as railroad and airport was designed and its electrical and EMI characteristics were measured. The output current of the LED module driven by SMPS was 1.67A for AC and DC input voltage over 10V. The conducted emission measured over 0.15~30MHz frequency range was lower than the allowed quasi-peak and average level, and the radiated noise measured over 30~1000MHz frequency range showed $23.96dB{\mu}V/m$ at 59.96MHz.

A Study on the Combustion Characteristics of the Small Scale Cyclone Incinerate System for Sludge (슬러지용 소형 사이클론 소각 시스템의 연소특성에 대한 연구)

  • Park, Woo-Cheul;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The performance of the small scale cyclone incinerate system (100kg/hr) to process the sewage sludge containing high moisture is evaluated. The incinerate system design is based on properties of the domestic sewage sludge. The combustion characteristics of the incinerate system is tested and analyzed with the various operation conditions of the moisture level, the sludge feed rate and the auxiliary fuel feed rate. The pressure loss of the whole system is appeared relatively small of 700mmAq under the normal operating condition and the temperature distribution of the incinerator internal combustion is maintained less than 1000C. Auxiliary fuel of 4.7 1/hr is required to incinerate 100kg sludge which include 87% moisture. Because the inside temperature of the incinerator is maintained less than $1000^{\circ}C$, it is predicted that the most NOx measured is produced not from the heat during the combustion process but from the oxidation of the N ingredient in the sludge. From the component analysis of ash, the organic matter is not entirely detected. Accordingly, it is estimated that the complete combustion has been accomplished in the incinerator.

  • PDF

A Study on the Post Occupancy Evaluation and the Optimum Scale of the Emergency Center In General Hospital (종합병원 응급센터의 거주후 평가와 적정 규모 결정에 관한 연구)

  • Lee, Teuk-Koo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1995
  • This thesis aims to establish a criterion to determine the scale of emergency beds and emergency wards equipped in general hospitals in the suburbs of Seoul. A new, large hospital (over 1000 beds) located in the southeast area of Seoul was selected and investigated for the case of this study, and throuh the P.O.E. a few mistakes in the method of determining the scale of the emergency department there came to light. Joining together, the effectiveness of the scale determination method devised by us (Lee's formula) was verified, and finally the optimum scale of the emergency department for this general hospital was proposed.

  • PDF

The Effect of $Y_2O_3$ Dispersoids on the High Temperature Oxidation of Ti-34wt%Al-1.5wt%Mn Alloys (Ti-34wt%Al-1.5wt%Mn 합금의 고온산화에 미치는 $Y_2O_3$ 분산입자 첨가효과)

  • Lee, Dong-Bok
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.6
    • /
    • pp.288-294
    • /
    • 2006
  • Alloys of TiAl-Mn-(0, 5, 10)wt.% $Y_2O_3$ were prepared by a powder metallurgical route, and their oxidation behavior was studied at 800, 900 and $1000^{\circ}C$ in 1 atm of air. The scale formed on the alloys consisted of $TiO_2$ and $Al_2O_3$ oxides. During oxidation, Mn tended to diffuse outward, whereas oxygen diffused inward. The dispersoids of $T_2O_3$, which segregated at the matrix grain boundaries, acted as a diffusion channel for cations and oxygen ions, nucleation sites for oxides, and vacancy annihilation sites. $T_2O_3$ increased the scale thickness, but improved the scale adherence.