Kim, Ji Hyun;Nam, Ki Chang;Kim, Hojun;Nam, Yeon Gyo;Kim, You Jin;jo, Eun hye;Kwon, Bum Sun
Journal of Biomedical Engineering Research
/
v.42
no.3
/
pp.86-93
/
2021
Purpose: The purpose of this study is to find out the cognizance of medical device safety information (MDSI) monitoring in the hospital and oriental hospital workers, and the different aspect of MDSI between oriental medical devices and medical devices. Methods: The survey was performed both in the oriental medicine hospital and general hospital. The survey had 16 items; 2 items basic questions, 5 items in the awareness of MDSI, 5 items in the education of MDSI, 4 items in the necessity of defining oriental medical devices and differences between general and oriental medical devices. A total of 120 hospital worker were participated; 60 oriental medicine hospital workers and 60 general hospital workers. They had worked in the oriental medicine or general hospital associated with 'Medical Device Safety Monitoring Center, Dongguk University Ilsan Hospital' in 2019 and 2020. Results: The cognizance of MDSI was high both in oriental medicine hospital and general hospital workers and there were no significant differences between oriental medicine and general hospital workers. When we divided the hospital workers into the senior workers who had worked for over 3 years and junior workers for less than 3 years, the senior workers had higher awareness of MDSI than junior workers. However, the cognizance of education of MDSI was high which was not different between senior and junior workers. Both hospital workers thought that it was necessary to define oriental medicine device legally and the oriental medical device might have low risk and less side effect than medical device. Conclusion: The cognizance of MDSI was high and there was no significant differences between oriental medicine and general hospital workers. Because the senior hospital workers had higher recognition of MDSI, we need to provide the continuous education program for junior hospital workers. Although oriental medical device are thought to be safer than medical device, we need to have a legal definition.
In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.
Ionizer is used for improving manufacturing process and reducing inferior goods in the clean room. As a general rule, neutralization of the electrostatic charge is most important to make TFT-LCD, PDP and OLED. Pulse AC-static eliminator with output voltage of about 10.5kV has been used these days as neutralization device. But this device has a problem with lower performance which was caused by particles-adhesion on the electrode when it has been used for a long time. So we studied to solve the problem with lower performance using high Frequency(72kHz) static eliminator which was produced by Piezo transformer device, and compared Pulse-AC type with Piezo-electronic device such as decay time and ion balance for 10 weeks periods. As a result of this study, we found that Piezo transformer device has been maintained normal condition for 10 weeks. Also, we made the rule by this study, normally Piezo transformer device has to clean the electrode during every 11th weeks.
The safety device of infrared type for dangerous machine being used currently has a harmful effect on human's eye and skin. In this paper we explain about the characteristics of lasr source and analyze the amount of harmfulness on human's eye by simulation method. We used the datas given by ANSI in this simulation.
Kim Young-Gyu;Kim Pil-Jong;Kwon Boo-Kil;Park Gyo-Shik;Kim Ji-Youn
Journal of the Korean Institute of Gas
/
v.10
no.3
s.32
/
pp.54-59
/
2006
A safety device with shut-off function was developed for preventing intentional accidents that might happen by separating of cutting hoses connected to pressure regulators used in residential LP gas facility. For the verification of function and field adaptability, the safety device with shut-off function was tested in the state of joining the device to the regulator and a field test was carried out at home. This study shows that, at the inlet pressure of 0.07-1.56 MPa, the device shuts off the gas within the 5m length of hose regardless of the installation condition of the regulator. The shut-off flow rate increases in the order of perpendicular upward, horizontal and perpendicular downward. From the results of the field tests carried out at home for 5 months, there appears no problem using a gas range or a boiler. If the developed shut-off device is commercialized and distributed in the market the intentional accidents occurred by cutting or separating hoses can be prevented remarkably.
This study suggests systematic procedures to improve safety policies on prevention of industrial accidents associated with industrial machines and devices. Specifically, new method of cause analysis of industrial accidents associated with industrial machines and devices is suggested and the related accident data are re-analyzed. Effectiveness of direct safety regulations such as safety certification, self-declaration of conformity, safety device regulation and safety inspection of industrial machines and devices are also analyzed. Based on those analysis results, transition from the current user-oriented safety device regulation to more balanced direct regulations on both manufacturer and user is suggested. Together with severity and frequency of industrial accidents, unit severity and unit frequency need to be taken into account to further assess the risk associated with a particular industrial machine or device. Balance between safety regulations will be realized by proper adjustment of lists of safety certification and inspection, and certification and inspection standards. This will also guarantee the maximum benefit over cost in such safety regulations.
With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.
As the use of automatic handling equipment for sensitive semiconductor devices is rapidly increased, manufacturers of electronic components and equipments need to be more alert to the problem of electrostatic discharges(ESD). In order to analyze damage characteristics of semiconductor device damaged by ESD, this study adopts a new charged-device model(CDM), field-induced charged model(FCDM) simulator that is suitable for rapid, routine testing of semiconductor devices and provides a fast and inexpensive test that faithfully represents ESD hazards in plants. High voltage applied to the device under test is raised by the field of non-contacting electrodes in the FCDM simulator, which avoids premature device stressing and permits a faster test cycle. Discharge current and time are measured and calculated. The characteristics of electrostatic attenuation of domestic semiconductor devices are investigated to evaluate the ESD phenomena in the semiconductors. Also, the field charging mechanism, the device thresholds and failure modes are investigated and analyzed. The damaged devices obtained in the simulator are analyzed and evaluated by SEM. The results obtained in this paper can be used to prevent semiconductor devices form ESD hazards and be a foundation of research area and industry relevant to ESD phenomena.
Jo Young-Do;Lee Kyung-Sik;Jang Sung-Dong;Kim Ji-Yun
Journal of the Korean Institute of Gas
/
v.5
no.4
s.16
/
pp.62-69
/
2001
Gas safety devices are very effective to prevent catastrophic gas accident in domestic. The safety devices are included in domestic gas equipment such as extinguishing safety device and adapted at pipeline such as fuse cock, shut off device with gas alarm and so forth. In spite of using those safety devices, a few hundreds of gas accident was happened annually in residential house. In this study, we analysed systematically the domestic accidents which was happened in five years using fault tree analysis(FTA) method and analysed the effectiveness of individual safety device. And also, it was suggested that the rate of accident was decreased quantitatively by increasing safety device which is adapted in domestic. By analysis of 769 gas accidents in domestic, the order of effectiveness of safety device to prevent domestic gas accident was the multi-functional gas-safe-meter(micom-meter), fuse cock, gas leak alarm and CO alarm. If the above four kind of safety device are adapted to every house, about $59\%$ of accident will be reduced and the most of catastrophic gas accident will be Prevented in domestic.
This study was conducted to develop a screening method using Colilert-18 and a device for the detection of E. coli from agri-food production environments and fresh vegetables. The specificity and sensitivity of Colilert-18 by temperature ($37^{\circ}C$ and $44^{\circ}C$) were evaluated with 38 E. coli and 78 non-E. coli strains. The false-positive rate was 3.8% (3/78) and 0% (0/78) at $37^{\circ}C$ and $44^{\circ}C$, respectively. The detection limit of E. coli at $37^{\circ}C$ at <1.0 log CFU/250 ml was lower than that at $44^{\circ}C$. The efficiency of the developed device, which comprised an incubator equipped with a UV lamp to detect E. coli in the field, was evaluated by measuring the temperature and UV lamp brightness. The difference between the set temperature and actual temperature of the developed device was about $1.0^{\circ}C$. When applying the developed method and device to various samples, including utensils, gloves, irrigation water, seeds, and vegetables, there were no differences in detection rates of E. coli compared with the Korean Food Code method. For sanitary disposal of culture samples after experiments, the sterilization effect of sodium dichloroisocyanurate (NaDCC) tablets was assessed for use as a substitute for an autoclave. The addition of one tablet of NaDCC per 50 ml was sufficient to kill E. coli cultured in Colilert-18. These results show that the developed protocol and device can efficiently detect E. coli from agri-food production environments and vegetables.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.