Analysis of Energy Reduction of Free Cooling System with Regions of South Korea (지역별 프리쿨링 시스템의 에너지 절감 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan;Baek, Seung-Moon;Heo, Jeong-Ho;Kim, Young-Min
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.82-88
    • /
    • 2014
  • Using low outdoor temperature, free cooling system is used in a data center or industrial air-conditioning for energy saving. Because use of IT equipment has increased in some office building recently, there is a growing trend towards using free cooing system. Free cooling system performance is influenced by outdoor temperature. Therefore the performance is different with regions. In this study, performance characteristic of free cooling system is analysed and energy reduction is compared with some regions. Selected regions are 4 cities; including Ulsan analyzed in preceding research, Seoul, ChunCheon and Daejeon. The Aspentech software HYSYS 8.0v was used to conduct the analysis of free cooling system based on temperature per hour of 4 cities in 2013, respectively. The main result is following as. Free cooing system in this study has energy saving effect when outdoor temperature below $7^{\circ}C$. Becuase temperature of Chuncheon is relatively low, using free cooling system can conserve most air-conditioning energy. Energy reduction amount of Seoul is 11%, Chuncheon is 17.5%, Deajeon is 15%, Ulsan is 14%. In case of large scale of air-conditioning, it is reasonable to use free cooling system although the system is used in Seoul.

An Application of Optimum Heat Exchanger for the Grasp on Performance Characteristics of $NH_3$ Refrigeration System

  • Ha Ok Nam;Kwon Il Wook;Hong Suck Ju;Kim Jae Yeol;Lee Jong In;Jeon Sang Sin;Ha Kyung Soo;Lee Seung Jae;Park Chan Soo;Jeong Song Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.69-74
    • /
    • 2005
  • Since the use of CFC and HCFC refrigerants is to be restricted due to the depletion of ozone layer, this experiment applies the $NH_{3}$ gas to study the performance characteristics from the superheat control for improving the energy efficiency. The experiments are carried out for the condensing pressure of refrigeration system from 1500kPa to 1600kPa by 50kPa and for degree of superheat from $0^{circ}$ to $1^{circ}$ by $10^{circ}$ at each condensing pressure. As a result of experiment, 1) As degree of superheat increased, evaporating pressure of the compressor decreased so equilibrium temperature decreased. And specific volume of refrigerant vapors increased so refrigerant mass flow and heat load of the evaporator decreased. 2) An influence of change of condensing pressure on heat load of the evaporator was insignificant. 3) With the identical degree of superheat, change of compressed temperature was insignificant according to each condensing pressure, so there was little change in enthalpy.4) when the degree of superheat is $0^{circ}$C at each condensing pressure, the refrigeration system has the hi띤est performance.

Risk Assessment Technique for Gas Fuel Supply System of Combined Cycle Power Plants (II) : Based on Piping System Stress Analysis (복합화력발전의 가스연료 공급계통에 대한 위험도 평가 기법 연구 (II) : 배관 시스템 응력 해석을 이용한 위험도 평가)

  • Yu, Jong Min;Song, Jung Soo;Jeong, Tae Min;Lok, Vanno;Yoon, Kee Bong
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.14-25
    • /
    • 2018
  • The combined cycle power plant has a cycle of operating the gas turbine with fuel, such as natural gas, and then producing steam using residual heat. The fuel gas is supplied to the gas turbine at a level of 4 to 5 MPa, $200^{\circ}C$ through a compressor and a heat exchanger. In this study, the risk assessment method considering the piping system stress was carried out for safe operation and soundness of the gas fuel supply piping system. The API 580/581 RBI code, which is well known for its risk assessment techniques, is limited to reflect the effect of piping stress on risk. Therefore, the systematic stress of the pipeline is analyzed by using the piping analysis. For the study, the piping system stress analysis was performed using design data of a gas fuel supply piping of a combined cycle power plant. The result of probability of failure evaluated by the API code is compared to the result of stress ratio by piping analysis.

A Study on Measures to Achieve Performance and Safety of Air Respirators for Fire Fighters (소방대원용 공기호흡기의 성능안전확보 대책에 관한 연구)

  • Son, Bong-Sei;Oh, Suk-Hwan;Kim, Yeop-Rae
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.77-81
    • /
    • 2012
  • This study of aims to provide basic data for improve the performance of air respirators that generate by bad influencing elements in fire emergency field. With three types of conditions set up for these tests, the pressures of containers have been extracted; the ambient temperatures have been checked, and the generation of moisture inside and outside container have been checked and identified. Specifically, these tests have been conducted at temperatures ranging between $-20{\sim}40^{\circ}C$. The pressures of containers have been extracted to reach between 0.4~0.8 MPa, using a pressure regulating valve. These tests have resulted in no change in the temperature and moisture outside the containers and no generation of moisture inside the containers as well. Although moisture has been generated inside the pressure gauge, the amount of moisture has not exceeded 25 $mg/m^3$, i.e. the limit suggested by the Korean Government. Therefore, it is judged that the moisture generated inside air respirators, which can be the most critical issue in the equipment, is likely to be caused in the process of managing the equipment or replacing air in the equipment at places of end-users, rather than in the process of manufacturing and production of the equipment.

Hardware Implementation of Real-Time Blind Watermarking by Substituting Bitplanes of Wavelet DC Coefficients (웨이블릿 DC 계수의 비트평면 치환방법에 의한 실시간 블라인드 워터마킹 및 하드웨어 구현)

  • 서영호;김동욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.3C
    • /
    • pp.398-407
    • /
    • 2004
  • In this paper, a blind watermarking method which is suitable to the video compression using 2-D discrete wavelet transform was proposed and implemented into the hardware using VHDL(VHSIC Hardware Description Language). The goal of the proposed watermarking algorithm is the authentication about the manipulation of the watermark embedded image and the detection of the error positions. Considering the compressed video image, the proposed watermarking scheme is unrelated to the quantization and is able to concurrently embed or extract the watermark. We experimentally verified that the lowest frequency subband(LL4) is not sensitive to the change in the spatial domain, so LL4 subband was selected for the mark space. And the combination of the bitplanes which has the properties of both the minimum degradation of the image and the robustness was chosen as the embedded Point in the mark space in LL4 subband. Since we know the watermark embedded positions and the watermark is embedded by not varying the value but changing the value, the watermark can be extracted without the original image. Also, for the security when exposing the watermark embedded position, we embed the encrypted watermark by the block cipher. The proposed watermark algorithm shows the robustness against the general image manipulation and is easily transplanted into the image or video compressor with the minimal changing in the structure. The designed hardware has 4037 LABs(24%) and 85 ESBs(3%) in APEX20KC EP20K400CF672C7 FPGA of Altera and stably operates in 82MHz clock frequency.