• Title/Summary/Keyword: 9/7 Filter

Search Result 481, Processing Time 0.024 seconds

An Experimental Study on the Material Characteristics of Mechanical Filters for Eliminating High-Frequency Noise in Accelerometer Measurements (가속도 측정에 있어 고주파 잡음 제거를 위한 기계적 필터의 재료 특성에 관한 실험적 연구)

  • Choi, Won-Yeong;Yoo, Seong-Yeol;Cha, Ki-Up;Kim, Sung-Soo;Noh, Myoung-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.7
    • /
    • pp.773-778
    • /
    • 2011
  • Accelerometers are widely used to measure the lateral vibrations of pipe-like structures such as a gun tube under impulse loads. Stress waves that precede the lateral vibrations due to the explosion within a gun contribute little to the vibrations, but saturate the accelerometer input. A mechanical filter eliminates this high-frequency stress wave and only transmits the signal corresponding to the lateral vibrations. The mechanical filter consists of a mechanical structure for mounting the accelerometers and a damping material. The low-pass filter characteristics are determined from the equivalent damping and stiffness property of this damping material. In this paper, we tested nine commercially available damping materials for their vibration characteristics by using a test rig. We also observed the change in the vibration characteristics while compressing the material. We designed and manufactured a mechanical filter and verified its filtering performance.

Optimization Method for Plasmonic Color Filters of High Optical Efficiency

  • Lee, Seonuk;Park, Junsu;Ju, Byeong-Kwon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.9-15
    • /
    • 2015
  • Various studies with regard to increasing the optical efficiency of plasmonic color filters have previously been conducted, such as mixing materials or applying diverse pattern shapes. Fundamentally, it is important to maximize the photonic crystal effect by finding the optimum periods of lattice as well as calculating the most efficient transmission area. In this study, we propose a technical method for optimizing the plasmonic color filters that have a high color gamut and luminance by analyzing the light spectrums based on the 1931 color coordinate system. Moreover, we suggest a calculation method in order to define the individual color purity of red and green and blue filters. Consequently, efficiency values are obtained independently from each color filter by evaluating the color purity and the luminance. The final result obtained from simulation are 27.6% of relative luminance and 25.3% of color gamut. The proposed optimization method is applicable to all plasmonic color filters having photonic crystal arrays.

A Study on the Modified Adaptive MMSE Filtering for Mixed-Noise Elimination in Image Signals (영상신호에서의 복합 잡음 제거를 위한 수정된 적응 MMSE 필터링에 관한 연구)

  • Lee, Je-Il;Kim, Sung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.70-76
    • /
    • 1996
  • In the case of an image corrupted with mixed noise, conventional MMSE filter can not remove such a mixed noise properly, because the impulse moise cause a certain bias of the minimum mean-square error estimate at regions close to outliers. In this paper, we proposed the new method or removal of mixed noise by combining MMSE filtering structure with local multi-windowing method according to directions and with ranked-order method. As a result, the improvement of the image quality with the proposed was obtained between about 9.7 and 35.2 times in the sense of NMSE(normalized mean square errors) evaluation than that of MMSE filter. Also, we could obtain the enhanced image in the mixed noisy image from visual and quantitative aspect.

  • PDF

[4+4] Cyclodimer of tert-Butyl 9-Anthroate and Furan and [4+4] Cyclodimers of Alkyl 9-Anthroate

  • 노태희;임희준;김대균;전경문
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.9
    • /
    • pp.998-1002
    • /
    • 1997
  • Irradiation of tert-butyl 9-anthroate and furan through a Uranium glass filter gave the [4+4] cyclodimer (21.8%) of tert-butyl 9-anthroate and furan and the 1,4-10',9' cyclodimer (4.2%) of tert-butyl 9-anthroate as well as the 9,10-10',9' cyclodimer (65.7%) of tert-butyl 9-anthroate. The [4+4] cyclodimer of tert-butyl 9-anthroate and furan was found to be thermally dissociated into their unit components with the activation enthalpy of 35.6 kcal/mole and the activation entropy of 7.6 eu, and photochemically dissociated to produce excited tert-butyl 9-anthroate. Quantum yields for the photodissociation to tert-butyl 9-anthroate and the formation of excited tert-butyl 9-anthroate in cyclohexane at room temperature were determined to be 0.56 and 0.19, respectively. The 1,4-10',9' cyclodimer of tert-butyl 9-anthroate in DMF was thermally dissociated into tert-butyl 9-anthroate with the activation enthalpy of 34.8 kcal/mole and the activation entropy of 16.4 eu. Upon irradiation, the [4+4] cyclodimers of tert-butyl 9-anthroate and the [4+4] cyclodimers of methyl 9-anthroate were quantitatively dissociated. However, no adiabatic photoreversion was observed from any of the cyclodimers. Quantum yields for the photodissociation in cyclohexane at room temperature were measured and compared.

A Study on the Utilization of Effluent Treated by Double Process Using Fixed-media and Sand Filter Coated by Nano Silver for Wastewater Reclamation and Reusing System (고정상 담체와 은나노 모래여과를 이용한 이중 공정에서 처리수의 중수도 활용에 관한 연구)

  • Seon, Yong-Ho
    • KSBB Journal
    • /
    • v.21 no.4
    • /
    • pp.317-323
    • /
    • 2006
  • This study focused on the availability of wastewater reclamation and reusing system as one of the alternatives against the global water shortage in near future, which system is composed of two treatment steps; first, wastewater is injected into upflow $A^2O$ biofilm process(anaerobic/anoxic/oxic) reactor filled with polyethylene fixed-media, and the effluent of 1st steps continuously passed through downflow nano silver sand filter. The pH of the effluent ranged from 7.39 to 8.06(average 7.84), the $COD_{Mn}$ was $8{\sim}18mg/L$(average 12.1 mg/L), and $BOD_5$ was $2.1{\sim}10.0mg/L$(average 4.9 mg/L), that met all the wastewater reclamation and reusing system criteria. Besides, the SS concentrations of the effluent which was $3{\sim}9mg/L$(average 4.95 mg/L) met the criteria(5 mg/L), showing 94.8% of average removal efficiency. The 99.1% of the average removal efficiency of the E-coliform did not met the criteria(Not detected), which indicates the needs for the following chlorine disinfection treatment with the residual chlorine concentration of above 0.2 mg/L. There are no bacteria on the sand surface coated by nano silver. The removal efficiency of T-N and T-P that could be included into the criteria in the future was 50.3% and 27.2% respectively.

Treatment of Nutrients Using the Upflow Vegetated Filter (상향류식 수초여과지를 이용한 영양염류처리)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1287-1292
    • /
    • 2006
  • Constructed wetlands are well known as highly efficient system to treat wastewater from different sources. Among the constructed wetlands, upflow types of constructed wetlands have become a common selection of wastewater during the last decade. We conducted a pilot scale study at peen house on treating potential of nutrients by upflow vegetated filter(UVF) pilot wetland which was combined with hydrodynamic separator and used the cattail plant(Typha angustifolia), and operated with artificial nutrients influent. This study evaluate the performances of upflow vegetated fille, in removal of nutrients. The objectives of this study were two-fold: (i) to evaluate the nutrients removal performance of pilot-scale upflow vegetated filter, filled with a mixture of perlite and soil media and planted with cattails and (ii) to design of scale-up upflow vegetated filter using Froude number. Results indicated that, under the condition of the ranges of hydraulic surface load rate were $22.7{\pm}9.6\;m^3/m^2/day$, the average removal of $COD_{Mn}$, and TN, TP were 57.5%, 40.0% and 41.5%, respectively. Computational fluid dynamics, FLUENT 6.0 program was used to predict the distribution of velocity in UVF and hydrodynamic separator. Full scale UVF was designed using the Froude number scale-up method that was assumed geomertic similarity between model and prototype. Result shows that the UVF with 3 m diameter has capacity of design sewage flowrate 75 $m^3/day$.

Design of a 5.8 GHz Broad Band-Pass Filter with Second of Harmonics Suppression Using the Open Stubs (2차 고조파가 억제된 5.8 GHz 광대역 개방형 스터브 대역 통과 여파기 설계)

  • Choi, Young-Gu;Kim, Bok-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1107-1116
    • /
    • 2007
  • In this paper, a broadband open stubs band pass filters which can suppress the second harmonics using Z-transform technique, is designed, fabricated and characterized. The proposed broadband filters integrate the band stop filter with the FSCS structure and ${\lambda}_g/4$ open stub in order to suppress the second harmonics. Due to insertion of BSF at input and output terminal, the size of the filter was increased in the conventional filter, however, in the proposed structure, the position of inverter that connects the stubs can be integrated between those stubs, thereby decreasing the size. So, it can be fabricated in the size of $18.7{\times}16.9mm^2$ which is smaller size than conventional one. The measured results of the proposed filters have center frequency of a 5.8 GHz with bandwidth of 95 %, insertion loss of 0.6 dB, return loss of 14 dB. The simulation results are consistent with measurement results. The filter is designed far X-band satellite communication and ITS applications.

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Magnetoresistance of IrMn-Based Spin Filter Specular Spin Valves (IrMn 스핀필터 스페큘라 스핀밸브의 자기저항 특성)

  • Hwang, J.Y.;Rhee, J.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.236-239
    • /
    • 2004
  • We studied the specular spin valve (SSV) having the spin filter layer (SFL) in contact with the ultrathin free layer composed of Ta3/NiFe2/IrMn7/CoFel/(NOLl)/CoFe2/Cu1.8/CoFe( $t_{F}$)/Cu( $t_{SF}$ )/(NOL2)/Ta3.5 (in nm) by the magnetron sputtering system. For this antiferromagnetic I $r_{22}$M $n_{78}$-pinned spin filter specular spin valve (SFSSV) films, an optimal magnetoresistance (MR) ratio of 11.9% was obtained when both the free layer thickness ( $t_{F}$) and the SFL thickness ( $t_{SF}$ ) were 1.5 nm, and the MR ratio higher than 11% was maintained even when the $t_{F}$ was reduced to 1.0 nm. It was due to increase of specular electron by the nano-oxide layer (NOL) and of current shunting through the SFL. Moreover, the interlayer coupling field ( $H_{int}$) between free layer and pinned layer could be explained by considering the RKKY and magnetostatic coupling. The coercivity of the free layer ( $H_{cf}$ ) was significantly reduced as compared to the traditional spin valve (TSV), and was remained as low as 4 Oe when the $t_{F}$ varied from 1 nm to 4 urn. It was found that the SFL made it possible to reduce the free layer thickness and enhance the MR ratio without degrading the soft magnetic property of the free layer.

The performance of SA filters according to the filter order (SA 여파기의 차수에 따른 성능 평가)

  • Song, Jong-Kwan;Yoon, Byung-Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.7
    • /
    • pp.1502-1507
    • /
    • 2005
  • The SA filters have a very flexible structure by limiting the maximum subwindow size. This flexible structure presents an effective trade-off between the complexity and performance of the filters. In this paper, experimental results showing the performance variation according to the change of filter order and subfilter type(such as max, min, exclusive-OR, mod) are presented. We designed optimal SA filters minimizing MSE for the various noise conditions. These results show several new properties of SA filters.