• Title/Summary/Keyword: 88검정시행일정

Search Result 4, Processing Time 0.02 seconds

자료

  • Korea Institute of Registered Architects
    • Korean Architects
    • /
    • no.2 s.227
    • /
    • pp.78-85
    • /
    • 1988
  • PDF

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

The Difference between Clinical Manifestations and Feeding or Delivery Methods in Healthy Full-term Neonates and Those with Nosocomial Rotaviral Infection (수유 및 분만방법에 따른 신생아실 로타바이러스 원내감염의 증상 차이)

  • Lee, So Young;Kim, Hyun Ji;Kim, Mi Young;Kim, Won Duck;Lee, Dong Seok;Kim, Doo Kwun;Choi, Sung Min
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.5
    • /
    • pp.454-458
    • /
    • 2003
  • Purpose : Rotavirus is the main cause of infantile diarrheal disease worldwide. The purpose of this study is to assess the difference between clinical manifestations and feeding or delivery methods in healthy full-term neonates and those with nosocomially-acquired rotaviral infection. Methods : The study was conducted on 348 babies who were delivered in Dongguk University Kyongju Hospital from Jan 1 to June 30 in 2001. Stool specimens were collected from clinically symptomatic neonates. We studied the rate of positive stool rotazyme ELISA tests and positive symptoms. We compared the frequency of clinical manifestations according to the feeding methods [breast feeding(BF) or formula feeding(FF)] and the delivery methods[normal vaginal delivery(NVD) or Cesarean section(C/sec)]. Results : Rotavirus was detected in 152 of 348 babies. The rate of positive rotazyme ELISA test was 43.7% in healthy full-term symptomatic neonates. The most common symptom of rotaviral enteritis was mild fever; the others were watery diarrhea, abdominal distension, vomiting, delayed weight gain, irritability, poor oral intake and dehydration. Compared with FF neonates, BF neonates have lower frequency of symptoms, especially watery diarrhea, delayed weight gain and poor oral intake. The symptomatic frequency was higher in FF and NVD neonates than BF and C/sec. Conclusion : The symptoms of rotaviral enteritis were less frequent in BF or C/sec delivered neonates. BF appeared to alleviate the rotaviral enteritis but further studies are needed. The cause of the lower frequency of symptoms in C/sec delivered neonates was unknown.