The Journal of Korean Institute of Communications and Information Sciences
/
v.27
no.1A
/
pp.26-34
/
2002
Mobile telecommunication systems such as IS-95 and IMT-2000 employ frame based communication using frames up to 20 msec in length and the receiving end has to store the whole frome before it is being processed. The size of the frame buffer ofter dominates those of the processing unit such as soft decision Viterbi decoder. The frame buffer for IMT-2000, for example, has to be increased 80 times as large as that of IS-95. One of the parameters deciding the number of bits in a frame will be obviously the number of bits in soft quantization. Start after striking space key 2 times. This paper has studied a new aspect of offset and quantization step size on BER performance and proposes a new 3-bit soft quantization algorithm which shows similar performance as that of 4-bit soft decision Viterbi receiver. The optimal offset values and step sizes for the other practical quantization levels ---16, 8, 4, 2--- have also been found. In addition, a new optimal symbol metric table has been devised which takes the accumulation value of various repeated signals and produces a rescaled 3-bit valu.tart after striking space key 2 times.
Kim, Jin-Eui;Kim, Jung-Soo;Han, Jae-Bok;Choi, Nam-Gil
The Journal of the Korea Contents Association
/
v.16
no.3
/
pp.219-231
/
2016
$^{99m}Tc$-DMSA planar scan that can analyze the functions of kidney quantitatively provides less information on a lesion than tomography scanning. Therefore, this study applied a high sensitivity all-purpose collimator that is sensitive to photonic signals to $^{99m}Tc$-DMSA and carried out a clinical scan with single photon emission computed tomography (SPECT). And diagnostic accuracy and time requirement of were analyzed to know the clinical usefulness of the applied scanning method. 10 subjects were intravenously injected with radiopharmaceutical product (1.0-1.2 MBq/kg) and scanned by a gamma camera with planar scanner (high resolution (HR)-mode, $256{\times}256$, 50 kcts/view, 4 image) and SPECT (HR / high sensitive (HS)-mode, $128{\times}128$, step and shoot, $180^{\circ}$, variable sec/angle, total 64 frame, OSEM reconstruction), respectively. The collected data was compared with an analysis program. The results showed that HS-mode SPECT detected total counts 1.8-5.6 times more than planar scan. Relative renal function evaluated based on the counts was not significantly different by two scanning methods (p=0.96) and it turned out that test time was shortened by 39% when HS-mode SPECT was used. Therefore, SPECT using HR, HS-mode collimator could analyze renal function more quantitatively than using planar scan and the former could diagnose the location information of a lesion more accurately than the latter as well as shortened test time requirement, which demonstrated the clinical usefulness of $^{99m}Tc$-DMSA renal SPECT using high sensitivity all purpose collimator.
Paenibacillus sp. HY-8 isolated from the digestive tracts of the longicorn beetle, Moechotypa diphysis, produced an extracellular endoxylanase with a molecular weight of 20 kDa estimated by SDS-PAGE. The xylanase was purified to near electrophoretic homogeneity from the culture supernatant after ammonium sulfate precipitation, gel filtration, and ionexchange chromatography. The purified xylanase exhibited the highest activities at pH 6.0 and $50^{\circ}C$. The $K_m\;and\;V_{max}$ values were 7.2 mg/ml and 16.3 U/mg, respectively, for birchwood xylan as the substrate. Nucleotide sequence of the PCR-cloned gene was determined to have the open reading frame encoding a polypeptide of 212 amino acids. The N-terminal amino acid sequence and the nucleotide sequence analyses predicted that the precursor xylanase contained a signal peptide composed of 28 amino acids and a catalytically active 19.9-kDa peptide fragment. The deduced amino acid sequence shared extensive similarity with those of the glycoside hydrolase family 11 of xylanases from other bacteria. The predicted amino acid sequence contained two glutamate residues, previously identified as essential and conserved for active sites in other xylanases of the glycoside hydrolase family 11.
Journal of the Korean Society of Fisheries and Ocean Technology
/
v.41
no.2
/
pp.122-128
/
2005
The experiments were conducted to fine out the handling characteristics of the FMT(Frame Mideater Trawl) in the southern waters of Korea using a trawler "DONGBAEK" belongs to Yosu National University. The realtionship between the net depth D(m) and the warp length L(m) at the towing speeds of 2.5k't and 3.5k't werw as follows ; D(m) = 0.30L - 1.3(2.5k't), D(m) = 0.16L - 1.5(3.5k't). Therefore, the net depth was 3.0m deeper when the warp length was 10m longer at the towing speed of 2.5k't and was 1.6m deeper for 10m longer at the speed of 3.5k't, respectively. The sinking speed of FMT was 6.5m/min when the warp releasing speed was 24m/min at the towing speed of 2.5k't and was 3.8m/min for 25m/min at the towing speed of 3.5k't, respectively. The rising speed of FMT was 6.9m/min when the warp rewinding speed was 28m/min at the towing speed of 2.5k't and was 5.3m/min for 25m/min at the towing speed of 3.5k't, respectively. The mean elapsed time getting to the stable towing condition was 104sec at the towing speed of 2.5k't and was 105sec at the towing speed of 3.5k't, respectively, and there was no time difference for the towing speed variation. During the towing, the net depth was comparatively stable on the condition of no change for the warp length and the towing speed.
Mansouri, Iman;Arabzadeh, Ali;Farzampour, Alireza;Hu, Jong Wan
Steel and Composite Structures
/
v.37
no.1
/
pp.91-98
/
2020
Steel plate shear walls are recently used as efficient seismic lateral resisting systems. These lateral resistant structures are implemented to provide more strength, stiffness and ductility in limited space areas. In this study, the seismic behavior of the multi-story steel frames with steel plate shear walls are investigated for buildings with 4, 8, 12 and 16 stories using verified computational modeling platforms. Different number of steel moment bays with distinctive lengths are investigated to effectively determine the deflection amplification factor for low-rise and high-rise structures. Results showed that the dissipated energy in moment frames with steel plates are significantly related to the inside panel. It is shown that more than 50% of the dissipated energy under various ground motions is dissipated by the panel itself, and increasing the steel plate length leads to higher energy dissipation capability. The deflection amplification factor is studied in details for various verified parametric cases, and it is concluded that for a typical multi-story moment frame with steel plate shear walls, the amplification factor is 4.93 which is less than the recommended conservative values in the design codes. It is shown that the deflection amplification factor decreases if the height of the building increases, for which the frames with more than six stories would have less recommended deflection amplification factor. In addition, increasing the number of bays or decreasing the steel plate shear wall length leads to a reduction of the deflection amplification factor.
This paper presents the real-time implementation of an AMR (Adaptive Multi Rate) vocoder which is included in the asynchronous International Mobile Telecommunication (IMT)-2000 mobile ASIC. The implemented AMR vocoder is a multi-rate coder with 8 modes operating at bit rates from 12.2kbps down to 4.75kbps. Not only the encoder and the decoder as basic functions of the vocoder are implemented, but VAD (Voice Activity Detection), SCR (Source Controlled Rate) operation and frame structuring blocks for the system interface are also implemented in this vocoder. The DSP for AMR vocoder implementation is a 16bit fixed-point DSP which is based on the TeakLite core and consists of memory block, serial interface block, register files for the parallel interface with CPU, and interrupt control logic. Through the implementation, we reduce the maximum operating complexity to 24MIPS by efficiently managing the memory structure. The AMR vocoder is verified throughout all the test vectors provided by 3GPP, and stable operation in the real-time testing board is also proved.
The Journal of Korean Institute of Communications and Information Sciences
/
v.37A
no.9
/
pp.786-791
/
2012
This paper presents a depth boundary sharpening method for improved view synthesis in 3D video. In depth coding, distortion occurs around object boundaries, degrading the quality of synthesized images. In order to encounter this problem, the proposed method estimates an edge map for each frame to filter only the boundary regions. In particular, a window-based filter is employed to choose the most reliable pixel as the replacement considering three factors: frequency, similarity and closeness. The proposed method was implemented as post-processing of the deblocking filter in JMVC 8.3.Compared to the conventional methods, the proposed method generated 0.49 dB PSNR increase and 16.58% bitrate decrease on average. The improved portions were subjectively confirmed as well.
Kim, Soo Cheol;Sumi, Kanij Rukshana;Sharker, Md Rajib;Kho, Kang Hee
Journal of Marine Life Science
/
v.3
no.1
/
pp.1-8
/
2018
Myosin is considered as the vital motor protein in vertebrates and invertebrates. Our present study was conducted to decipher the occurrence of myosin in dog fish (Squalus mitsukurii). We isolated one clone containing 979 bp cDNA sequence, which consisted of a complete coding sequence of 453 bp and a deduced amino acid sequence of 150 amino acids from the open reading frame with molecular weight, isoelectric point and aliphatic index are 16.72 Kda, 4.49 and 78.00, respectively. It contained 428 bp long 3' UTR with single potential polyadenylation signals (AATAAA). The predicted EF CA2+ binding domains were identified in residue 6-41, 83-118 and 133-150. A BLAST search indicates this protein exhibits a strong similarity to whale shark (Rhincodon typus) MLC3 (91% identical) and also house mouse (Mus musculus) MLC isoform 3f (81% identical). Phylogenetic analysis revealed that this protein is a MLC 3 isoform like protein. This protein also demonstrates highly conserved region with other myosin proteins. Homology modeling of S. mitsukuri was performed using crystal structure of Gallus gallus skeletal muscle myosin II based on high similarity. Reverse transcription-polymerase chain reaction (PCR), quantitative PCR results exhibits dogfish myosin protein is highly expressed in muscle tissue.
Journal of the Korean Society for Precision Engineering
/
v.16
no.2
s.95
/
pp.39-49
/
1999
This paper describes the development of a vision-aided position and orientation recognition system for automatically adjusting electronic tuners which control the waveform by rotating variable resisters. The position and orientation recognition system estimates the center and the angle of the tuner grooves so that the main controller may correct the difference from the ideal position and thereby manipulate the variable resisters automatically. In this paper a robust algorithm is suggested which estimates the center and the angle of the tuner grooves fast and precisly from the source image with lighting variance and video noise. In the algorithm morphological filtering, 8-chain coding, and invariant moments are sequentially used to figure out image segments concerned. The performance of the proposed system was evaluated using a set of real specimens. The results indicate the system works well enough to be used practically in real manufacturing lines. If the system adopts a high speed frame grabber which enables real time image processing, it can also be applied to positioning of robot manipulators as well as automated PCB adjusters.
Ganjavi, Behnoud;Hadinejad, Amirali;Jafarieh, Amir Hossein
Steel and Composite Structures
/
v.32
no.1
/
pp.91-110
/
2019
In the present study, the effects of six different ground motion scaling methods on inelastic response of nonlinear steel moment frames (SMFs) are studied. The frames were designed using energy-based PBPD approach with the design concept using pre-selected target drift and yield mechanism as performance limit state. Two target spectrums are considered: maximum credible earthquake spectrum (MCE) and design response spectrum (DRS). In order to investigate the effects of ground motion scaling methods on the response of the structures, totally 3216 nonlinear models including three frames with 4, 8 and 16 stories are designed using PBPD approach and then they are subjected to ensembles of ground motions including 42 far-fault and 90 near-fault pulse-type records which were scaled using the six different scaling methods in accordance to the two aforementioned target spectrums. The distributions of maximum inter-story drift over the height of the structures are computed and compared. Finally, the efficiency and reliability of each ground motion scaling method to estimate the maximum nonlinear inter-story drift of special steel moment frames designed by energy-based PBPD approach are statistically investigated, and the most suitable scaling methods with the lowest dispersion for two groups of earthquake ground motions are introduced.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.