• Title/Summary/Keyword: 7T MRI

Search Result 361, Processing Time 0.026 seconds

B1+ Homogenizaion over Whole Field of View in High Field MRI (고자장 MRI에서의 영상 영역에 대한 B1+ 균질성)

  • Kim, Hong-Joon;Son, Hyeok-Woo;Cho, Young-Ki;Yoo, Hyoung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.96-100
    • /
    • 2012
  • In high static field magnetic resonance imaging(MRI) systems, $B_0$ fields of 7 T and 9.4 T, the impressed RF field shows larger inhomogeneity than in clinical MRI systems with B0 fields of 1.5 T and 3.0 T. In multi-channel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the non-uniformity of the impressed RF $B_1^+$ field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected ROI(Region of Interest). To demonstrate the technique, the multichannel transmission line coil was modeled together with a human head phantom at 400 MHz for the 9.4 T MRI system and $B_1^+$ fields are obtained. In this paper, all the optimized $B_1^+$ in each isolated ROIs are combined to achieve significantly improved homogeneity over the entire field of view. The simulation results for 9.4 T MRI systems are discussed in detail.

Cerebral Infarction Model in Rat on Magnetic Resonance Imaging (흰 쥐의 뇌경색 병변에 대한 자기공명영상)

  • Jung, Ji-Sung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.55-58
    • /
    • 2011
  • It is important to study using experimental animals for research about stroke. Magnetic Resonance Imaging(MRI) is avaluable diagnosticmethods for stroke diagnosis. The purpose of this research is to know the Magnetic Resonance Imaging(MRI) and histopathological characteristics findings after induction of photothrombotic cerebral infarction in rat brain. Male Sprague-Dawley rats were anesthetized, Rose Bengal dye(20 mg/kg) was intravenously injected. The right sensonrimotor cortex of rat brain was exposed to cold light of 7 mm diameter at a position of 1 mm anterior and 3.5 mm lateral to bregma for 20 min. The post-infarction effects were monitored by T1 weighted and T2 weighted images of brain MRI. Histopathological changes were observed after Hematoxylin & Eosin staining. The lesion appeared clearly high signal intensity area on T2 weighted images(the major axis $7.04{\pm}0.11$ mm, the minor axis $3.08{\pm}0.04$ mm) and also H&E staining was same result. In conclusion, MRI was avaluable diagnostic methods for diagnosis and serial changes of stroke.

  • PDF

The Value of Additional Cervicothoracic Spine Sagittal T2-weighted Images Included in Routine Lumbar Spine MR Imaging (요추 MR영상에 포함된 경흉추 시상T2강조영상의 효용성 평가)

  • Seo, Jiwoon;Park, So Young;Lee, Joon Woo;Lee, Guen Young;Kang, Heung Sik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.91-100
    • /
    • 2013
  • Purpose : To evaluate the usefulness of cervicothoracic spine sagittal T2-weighted images (CT SAG T2WIs) included in routine lumbar spine MRI. Materials and Methods: Institutional review board approval was obtained and informed consents were waived for this retrospective study. The study group comprised 2,113 patients who underwent lumbar spine MRI from January 2005 to December 2005. CT SAG T2WIs were added in the routine lumbar spine MRIs. Radiologic reports were reviewed retrospectively for pathologic lesions on CT SAG T2WIs by one radiologist. Information of additional cervical or thoracic spine MRI and/or CT for further evaluation of positive findings on CT SAG T2WIs and their treatment were collected by retrospectively reviewing medical records. Results: The CT SAG T2WIs revealed 142 pathologic lesions in 139 (6.58%) of the 2,113 patients. They were easily obtained without positional change in a scan time of less than 2 minutes. Additional cervical or thoracic spine MRI and/or CT for positive findings on CT SAG T2WIs were performed in 13 patients. Seven patients underwent surgical treatment. Conclusion: CT SAG T2WIs included in routine lumbar spine MRI were useful in finding the pathologic lesions in cervicothoracic spine for the patients who assumed to have lesions in lumbar spine.

A New Medical Lead for Various MRI Systems (다양한 MRI 시스템에서 사용가능한 의료용 리드선)

  • Kim, Hongjoon;Yoo, Hyoungsuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.429-432
    • /
    • 2015
  • Radio Frequency (RF) coils in Magnetic Resonance Imaging (MRI) systems interact with a patient's tissues, resulting in the absorption of RF energy by the tissues. The presence of an electrically conducting medical implant may concentrate the RF energy and causes tissue heating near the implant devices. Here we present a novel design for a medical lead to reduce this undesired heating. Specific Absorption Rate (SAR), an indicator of heating, was calculated. Remcom XFdtd software was used to calculate the peak SAR distribution (1g and 10 g) in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 MHz (1.5 T MRI), 128 MHz (3 T MRI) and 300 MHz (7 T MRI) using a model of an MR birdcage body coil. Our results demonstrate that, our proposed design of adding nails to the medical lead can significantly reduce the SAR for different MRI systems.

A Study on the Usability of Echo Planar Image T2 FLAIR Sequence in the MRI of Acute Ischemic Cerebral Infarction (급성 허혈성 뇌경색 환자의 자기공명영상 검사 시 Echo Planar Image T2 FLAIR 기법의 유용성에 관한 연구)

  • Roh, Taegwan;Jo, Yongkeun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.957-964
    • /
    • 2020
  • T2 FLAIR sequence of MRI in Acute Ischemic Stroke patients is meaningful to those who have the diagnosis of cerebral hemorrhage and neurological deficiency, including the detection of cerebral infarction around Cerebrospinal fluid. However, because of the long acquisition time and mutative motion artifacts caused by movement, It is difficult to take the MRI image acquisition for non-cooperative patients who need to apply a rapid image acquisition. In this study, we applied the EPI-FLAIR sequence, which is one of the fastest pulse sequences in use, which is a combination of EPI sequence and T2 FLAIR sequence, to patients with acute ischemic cerebral infarction. Based on the qualitative and quantitative evaluation results of the EPI-FLAIR and T2 FLAIR image, we will evaluate the diagnostic usefulness of the EPI-FLAIR sequence.

Application of Magnetic Resonance Thermometry (MRT) on Fully Developed Turbulent Pipe Flow using 3T and 7T MRI (완전발달 난류 원관 유동에서의 3T 및 7T MRI를 이용한 자기공명온도계의 적용)

  • You, Hyung Woo;Baek, Seungchan;Kim, Dong-Hyun;Lee, Whal;Oh, Sukhoon;Hwang, Wontae
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.1
    • /
    • pp.26-37
    • /
    • 2020
  • Magnetic resonance thermometry (MRT) is a technique capable of measuring three-dimensional mean temperature fields by utilizing temperature-dependent shifts in proton resonance frequency. In this study, experimental verification of the technique is obtained by measuring 3D temperature fields within fully developed turbulent pipe flow, using 3T and 7T MRI scanners. The effect of the proton resonance frequency (PRF) thermal constant is examined in detail.

A Study of the Quantitative, Qualitative Analysis on Optimizing Diagnostic Imaging Device Selection in Nasopharynx MRI (비 인두 자기공명 검사 시 최적의 진단영상 장치 선택에 관한 정량, 정성적 평가에 관한 연구)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.1035-1043
    • /
    • 2019
  • The object of is this research is to find out the optimal Tesla by evaluating SNR and CNR, after testing 1.5 T and 3.0 T. The randomly selected patients tested by nasopharynx MRI transmitted in PACS were applied to the research. Two MRI units(1.5 T, 3.0 T) was used for analyzing the data. As a method of analysis, in T1W highlighting and T1 fat removal images, we set up a certain area of interest and evaluated the SNR and CNR on tongue, spinal cord, masseter muscle, fat, parotid gland, and tumor tissue. We evaluated the SNR and CNR by quantitative analysis of six tissue, measuring the quality of images for uniform fat removal, magnetic sensitivity artifact on a four-point scale by qualitative analysis. The statistical significance of this date analysis was based on independent sample verification and was accepted when the P value was less than 0.05. As a result of analysis of both devices, 3.0 T was high in the quantitative evaluation, while 1.5 T was high in the qualitative evaluation. Considering the advantages and disadvantages of each device, and if the device is selected complementarily and applied to patients, it is believed that it will provide the optimal information.

Improvement of High Permittivity Pads for Areas with Generally Low Signal Sensitivity at 7T MRI (7T MRI에서 일반적으로 신호 감도가 낮은 영역에 대한 고유전율 패드 개선)

  • Yong-Tae, Kim;Hyeon-Man, Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.761-769
    • /
    • 2022
  • Pads with high dielectric materials have been used in a variety of applications to locally improve the field sensitivity and homogeneity of RF pulses in clinical MRI studies. In this study, we aimed to improve such pads in consideration of the practical problems associated with the application of actual clinical images. A high permittivity pad to increase the attenuated B1 field strength was fabricated and tested in 7T MRI. Sim4Life simulation and experimental results show stronger and relatively uniform B1 near field. In order to improve the image quality in the whole cerebellum, known as a region with low sensitivity, a guide was made to reduce the mechanical change of the pad. In order to improve the wearing comfort, the pad was designed by dividing it into upper and lower parts. The facial pad showed an overall signal increase effect in areas such as the turbinate in the nasal cavity. Signal increase was expected in areas such as the frontal lobe and eyes, but the effect was either insignificant or it was difficult to see the effect in the imaging protocol. In conclusion, this paper showed a cerebellar-optimized pad with an improved nasal signal while maintaining its effectiveness.

Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence (MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • In this paper, we introduce how to change the reaction rate as mol concentration when we scan enhanced MRI with GBCA(Gadolinium Based Contrast Agent), Also show the changing patterns depending on diverse MRI sequences which are made by different physical principle. For this study, we made MRI phantom ourselves. We mixed 500 mmol Gadoteridol with Saline in each 28 different containers from 500 to 0 mmol. After that, MR phantom was scanned by physically different MRI sequences which are T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE and 3D SPCIR in 1.5T bore. The results were as follows : *T1 Spin echo's Total SI(Signal Intensity) was 15608.7, Max peak was 1352.6 in 1 mmol. *T2 FLAIR's Total SI was 9106.4, Max peak was 0.4 1721.6 in 1 mmol. *T1 FLAIR's Total SI was 20972.5, Max peak was 1604.9 in 1 mmol. *3D FLASH's Total SI was 20924.0, Max peak was 1425.7 in 40 mmol. *3D SPACE 1mm's Total SI was 6399.0, Max peak was 528.3 in 3 mmol. *3D SPACE 5mm's Total SI was 6276.5, Max peak was 514.6 in 2 mmol. *3D SPCIR's Total SI was 1778.8, Max peak was 383.8 in 0.4 mmol. In most sequences, High signal intensity was shown in diluted lower concentration rather than high concentration, And also graph's max peak and pattern had difference value according to the each different sequence. Through this paper which have quantitative result of GBCA's reaction rate depending on sequence, We expect that practical enhanced MR protocol can be performed in clinical field.

Relationship between anterior disc displacement with/without reduction and effusion in temporomandibular disorder patients using magnetic resonance imaging

  • Koh, Kwang-Joon;Park, Ha-Na;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.245-251
    • /
    • 2013
  • Purpose: This study was performed to evaluate the relationship between anterior disc displacement and effusion in temporomandibular disorder (TMD) patients using magnetic resonance imaging (MRI). Materials and Methods: The study subjects included 253 TMD patients. MRI examinations were performed using a 1.5 T MRI scanner. T1- and T2-weighted images with para-sagittal and para-coronal images were obtained. According to the MRI findings, temporomandibular joint (TMJ) disc positions were divided into 3 subgroups: normal, anterior disc displacement with reduction (DWR), and anterior disc displacement without reduction (DWOR). The cases of effusion were divided into 4 groups: normal, mild (E1), moderate (E2), and marked effusion (E3). Statistical analysis was made by the Fisher's exact test using SPSS (version 12.0, SPSS Inc., Chicago, IL, USA). Results: The subjects consisted of 62 males and 191 females with a mean age of 28.5 years. Of the 253 patients, T1- and T2-weighted images revealed 34 (13.4%) normal, DWR in 103 (40.7%), and DWOR in 116 (45.9%) on the right side and 37 (14.6%) normal, DWR in 94 (37.2%), and DWOR in 122 (48.2%) joints on the left side. Also, T2-images revealed 82 (32.4%) normal, 78 (30.8%) E1, 51 (20.2%) E2, and 42 (16.6%) E3 joints on the right side and 79 (31.2%) normal, 85 (33.6%) E1, 57 (22.5%) E2, and 32 (12.7%) E3 on the left side. There was no difference between the right and left side. Conclusion: Anterior disc displacement was not related to the MRI findings of effusion in TMD patients (P>0.05).