• Title/Summary/Keyword: 70ppb

Search Result 58, Processing Time 0.022 seconds

Effects of Environmental Endocrine Disruptor Bisphenol A on the Reproduction of Xiphophorus maculatus (환경호르몬 비스페놀 A가 Xiphophorus maculatus의 생식에 미치는 영향)

  • Deung, Young-Kun;Kim, Dong-Heui
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.43-50
    • /
    • 2004
  • In this study, we examined effects of environmental endocrine disruptor bisphenol A on the reproduction of Xiphophorus maculatus. We exposed the males of X. maculatus to the bisphenol A adjusted to the various concentrations such as 100 ppb, 200 ppb, 400 ppb and 800 ppb for 3 months for the experimental groups and then inbreeded with normal females that was not any treated. We counted the number of second generation for confirmation of fertilizing ability of first generation. Also, we observed the ratios of female and male, the abnormality and mortality, and spermatogenesis of the second generation was exposed to bisphenol A for 6 months. As the result, the number of fry in the second generation was $11.50{\pm}2.22$ in 100 ppb, $6.40{\pm}2.76$ in 200 ppb, $5.70{\pm}1.34$ in 400 ppb and $3.70{\pm}2.11$ in 800 ppb at the experimental groups while it was $19.00{\pm}3.02$ at the control group which was not treated with bisphenol A. This result showed that the experimental groups exhibited a decreasing tendency according to the increase of bisphenol A concentration comparing with the control group. The ratio of female and male of the second generation had no relations with the concentration of bisphenol A, and the ratios of abnormality and mortality were 0%. The spermatogenesis of experimental groups was normal in 800 ppb as well as 100 ppb, 200 ppb, 400 ppb after even 6 months.

Sensitivity of Five Clones of Populus alba × P. glandulosa Cuttings to Ozone Exposure in Open-Top Chambers in Relation to Their Growth Rates (Open-Top chamber 내(內)에서 오존에 노출(露出)시킨 현사시 5개(個) 클론의 생장량(生長量)과 오존에 대(對)한 민감성(敏感性)과의 관계(關係))

  • Kim, Tae Kyu;Lee, Kyung Joon;Kim, Goon Bo;Koo, Yong Bon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.1
    • /
    • pp.105-115
    • /
    • 2000
  • This study was conducted to test a hypothesis that sensitivity of trees to ozone exposure was related to their growth rates. Two cultivars of Populus alba ${\times}$ P. glandulosa with different genetic growth potential were used for the comparison. Two clones(72-30, 72-16) of cultivar No. 4 with fast growing potential and three clones(71-28, 72-27, 72-19) of cultivar No. 2 with slow growing potential were propagated in early spring by cutting in $2-{\ell}$ plastic pots. They were grown outdoor for 5 months and exposed in late August for 30 days to 70 and 130ppb ozone in a open-top chambers(2.5m in diameter and 2m in height). Ozone concentration in a control chamber was maintained below 30ppb by filtering with activated charcoal. Each treatment was replicated twenty times. In a control chamber, cultivar No. 4 grew 73%, 64%, and 38% faster than cultivar No. 2 in leaf weight, root weight, and total dry weight, respectively. Visible injury was observed only in cultivar No. 4 in 130ppb treatment. Ozone treatment at both 70 and 130ppb decreased height growth, dry weight of leaf, root, and entire plants in all five clones. Particularly root growth was reduced by 39.7% and 13.8% in cultivar No. 4 and No. 2, respectively, in 70ppb treatment. Consequently, shoot/root ratio of cultivar No.4 was increased by 63.4%, while that of cultivar No.2 was increased by 22.1%. Stomatal conductance decreased more in cultivar No.4 than in cultivar No.2. Net photosynthesis of cultivar No.4 at 130ppb ozone decreased by 69.5%, while that of cultivar No.2 decreased by 31.5%. Above mentioned physiological responses of two cultivars to ozone strongly suggested that fast growing cultivar No.4 was more sensitive to ozone than slow growing cultivar No.2. It was concluded that sensitivity of trees to ozone exposure was closely related to their growth rates.

  • PDF

Analytical examples of volatile amines in ambient airs (공기 중 저급아민류의 분석과 측정 사례)

  • Yu, Mee-Seon;Yang, Sung-Bong
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.216-223
    • /
    • 2005
  • In this study, several kinds of volatile amines in ambiant air were collected and their concentrations were expected from the calibration curves prepared by standard solutions of 7 amines by the official measuring method prescribed in Japanese Offensive Odor Law. The obtained calibration curves showed a good linearity and the detection limit of trimethyl amine was found to be about 0.033 ppb (0.040 ng) in case of 50 liters air. It means that trimethyl amine could be detected with the concentration of lower than its permitting level at the border line of companies. As typical examples of measuring amines in air, results of investigation of two sewage works and one rendering plant around the capital area indicated that 4 kinds of amines, i.e. methyl amine, dimethyl amine, trimethyl amine and isopropyl amine were detectable and concentrations of trimethyl amine at the primary sedimentation pond and sludge dewatering building of the sewage plant A showed 9.07 ppb and 7.79 ppb respectively, being over the concentration of odor strength 2.5, And the aeration tank, excrement input facility and indoor of maintenance room of excrement process building in the sewage plant B showed 70.0 ppb of dimethyl amine and 2.44 ppb of trimethyl amine.

Odor Characteristics of Malodorous Sulfur-containing Gas Emitted from a Sewer and Its Outlets (하수관거 및 토구에서 발생하는 유황계 화합물 악취특성)

  • Park, Sang Jin;Kwon, Soo Youl
    • Journal of Environmental Health Sciences
    • /
    • v.40 no.6
    • /
    • pp.477-483
    • /
    • 2014
  • Objectives: This study was carried out to investigate the characteristics of odors emitted from sewage in a sanitary sewer and its outlets. Methods: The concentration of mal-odorous sulfur was analyzed by gas chromatograph, and odor intensity was estimated by an on-site sensory test. Odor intensity calculated from instrumental analysis results was compared with odor intensity observed at field. Results: As a results, the concentration of $H_2S$ ranged from 2.4 ppb to 5,889 ppb (average 703 ppb), while $CH_3SH$, $(CH_3)_2S$, and $(CH_3)_2S_2$ showed from 10 ppb to 554 ppb (average 119 ppb) and from 20 ppb to 332 ppb (average 70 ppb) and from 2.7 ppb to 8.1 ppb (average 5 ppb) individually. Average odor intensity observed in the field was degree three. Odor intensity calculated from sulfur compound concentration was confirmed as similar to the observed odor intensity because the coefficient of variance between the observed and the calculated intensities was less than one. Conclusion: It was expected that the results of this study will be helpful to design a deodorizing device to reduce odor emissions from sewerage facilities in the future.

Effects of PCBs (Polychlorinated Biphenyls) on Energy Budget in Mysid, Neomysis awatschensis II. Effects of PCBs on Energy Budget in Mysid, Neomysis awatschensis (곤쟁이, Neomysis awatschensis의 에너지수지에 미치는 PCBs의 영향 II. 에너지수지에 미치는 PCBs의 영향)

  • CHIN Pyung;SHIN Yun-Kyung;JEON Eun-Mi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.1
    • /
    • pp.104-108
    • /
    • 1998
  • Analysis of energy budget in Neomysis awatschensis exposed to PCB toxicity was carried out by measurement of bioassay, growth, oxygen consumption, nitrogen excretion at 10 and $20^{\circ}C$. Energy contents of the body, molted exoskeleton and eggs, which measured to understand used energy for growth, molt and oxygen consumption were 5.52cal/mg, 2.17 cal/mg and 6.15 cal/mg, respectively. Feeding energies at $10^{\circ}C$ were 3.755ca1 in control group and 3.420 cal at 2.0 ppb concentration, of them, $70.19\%$ and $67.53\%$ of their energies were assimilated. At $20^{\circ}C$, feeding energies were 5.998 cal in control group and 4.166 cal at 2.0 ppb concentration. The assimilation efficiency of the mysid estimated by ash-ratio method ranged between $11.5\~67.5\%$ and $73.4\~70.5\%$ with PCB toxicity at $10^{\circ}C$ and $20^{\circ}C$ respectively. Energy used by respiration of total assimilated energy was $45.18\%$ in control group and $62.27\%$ in 2.0 pub concentration at $20^{\circ}C$, and energy used by metabolism was high 2.0 ppb concentration than control group.

  • PDF

Enzyme-Linked Immunosorbent Assay for Detection of Nivalenol (Nivaleno의 검출을 위한 효소 면역 측정법)

  • 손동화;이향범;곽보연;김수호;권창희
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.2
    • /
    • pp.129-134
    • /
    • 1998
  • To develop an enzyme-linked immunosorbent assay (ELISA) for nivalenol (NIV), we produced polyclonal antibodies against tetraacetyl nivalenol (Ac4-NIV) and established ELISA conditions. Ac4-NIV-hemisuccinate conjugated to bovine serum albumin (Ac4-NIV-HS-BSA) was immunized with Freund's adjuvants into rabbits subcutaneously several times. By use of the antiserum showing the highest titer and Ac4-NIV-HS-HRP conjugate, we established competitive direct ELISA (cdELISA). Standard curve of cdELISA showed that the detection range of Ac4-NIV was about 10~5,000 ng/ml (ppb). The cross-reactivities of the polyclonal antibody towards Ac4-NIV and acetyl T-2 were 100 and 70% respectively, and those towards NIV, deoxynivalenol, 3-acetyl deoxynivalenol, 15-acetyl deoxynivalenol, triacetyl deoxynivalenol, fusarenonX, and T-2 were less than 0.1%. When cdELISA was applied to NIV-spiked corns followed by extraction with 70% acetonitrile and acetylation with acetic anhydride in pyridine, the recovery rates of the Ac4-NIV were 108, 143, and 70% (average, 107%) in the levels of 100, 300, and 1,000 ng/g (ppb), respectively.

  • PDF

Reduction of Benzo(a)pyrene Content in Sesame Oil by Using Adsorbents (흡착제를 이용한 참기름의 벤조피렌 저감화)

  • Choi, Seung Kwan;Choe, Su Bin;Kang, Sung Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.4
    • /
    • pp.564-569
    • /
    • 2014
  • This study was conducted to reduce benzo(a)pyrene in sesame oil by addition of several kinds of absorbents (active carbon, diatomaceous earth, kaolin, acid clay, perlite, and silicate). Sesame oil containing 4.1 ppb benzo(a)pyrene was stirred with 0.2% (w/w) several kinds of adsorbents at $40^{\circ}C$ for 30 min. Active carbon resulted in the highest reduction of benzo(a)pyrene in sesame oil among the investigated adsorbents, and decolorization was observed only by using silicate. Reduction of benzo(a)pyrene was optimized by controlling amount the of active carbon, stirring time, and stirring temperature. Futher, 4.1 ppb benzo(a)pyrene in sesame oil was reduced by up to 0.91 ppb by adding 0.5% (w/w) active carbon and stirring for 30 min at $70^{\circ}C$. Optimized conditions were applied to sesame oil (2.14~4.11 ppb) purchased from a Gyeonggi traditional market, and benzo(a)pyrene in sesame oil was reduced by up 0.43~0.86 ppb.

Monitoring of Aluminium Phosphide Residues in Wheat and Wheat Flour (밀과 밀가루 중 알루미늄포스파이드 잔류량 모니터링)

  • Choi, Yong-Hoon;Yoon, Sang-Hyeon;Hong, Hye-Mi;Kang, Yun-Sook;Chae, Kab-Ryong;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.532-536
    • /
    • 2005
  • GC-NPD analysis was performed on residues of aluminium phosphide in raw wheat and wheat products by trapping gaseous phosphine in the headspace of vessel. In Australian wheat, over 95% of samples were detected below 1 ppb, considered as safe level, whereas in American wheat, about 70% of 58 samples were detected within 1-10 ppb with 4 showing over 10 ppb. About 14-22% phosphine residues of raw wheat were retained after milling process. Wheat samples of same origin showed significant varying levels of phosphine.

A Study on the Correlation and Concentration in Volatile Organic Compounds(Benzene, Toluene, Xylene) Levels According to the Indoor/Outdoor and the Type of Residents' House in Industrial Area (공단지역 일부 주민들의 주택유형 및 실내/외에 따른 VOCs(Benzene, Toluene, Xylene) 농도 및 상관성에 관한 연구)

  • Lee, Che-Won;Jeon, Hye-Li;Hong, Eun-Ju;Yu, Seung-Do;Kim, Dae-Sun;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.5
    • /
    • pp.351-359
    • /
    • 2010
  • The objectives of this study were to understand the characteristics of residents in industrial areas and factors affecting exposure to the Volatile Organic Compounds(VOCs : Benzene, Toluene, Xylene) as well as to assess exposure levels according to house-type, and whether residents were indoors or outdoors. This research was designed to assess the differences in exposure levels to indoor, outdoor and personal VOCs in a case group and a control group across all areas, as well as in each different area, from May to October 2007, in. 110 residents of the G, Y and H industrial areas of the Jun-nam province. The geometric mea-levels of airborne benzene for the case group 1.31part per billion(ppb) indoor, 1.29 ppb outdoor, and 1.32 ppb for personal exposure were significantly higher than for the control group 0.99, 0.87 and 0.57 ppb, respectively. The geometric mean level for toluene personal exposure across the G, Y and H areas was 5.70 ppb for the case group and 6.31 ppb for the control group. While the outdoor level was 4.27 ppb for the case group and 5.06 ppb for the control group, The indoor level for the case group was 4.78 ppb, similar to that of the control group 4.69 ppb. The geometric mean levels for airborne xylene across the G, Y and H areas were 0.16 ppb(outdoor), 0.12 ppb(personal exposure) and 0.10 ppb(indoor) for the case group, and for the control group were 0.17(personal exposure) and 0.09 ppb(indoor and outdoor). The indoor/outdoor(I/O) ratio for case group is 1.19, while that of the control group is 1.15, indicating that the indoor level was higher than the outdoor level. The interrelationship differences among the three different types of levels in the air in the G, Y and H areas are statistically significant, except for the difference between the indoor and outdoor figures for xylene. In terms of the different types of houses and energy type uesd, the geometric mean level for airborne benzene, toluene and xylene for houses were 1.61, 5.39 and 0.12 ppb, respectively. while the figures for flats were 0.67, 3.32 and 0.05 ppb, respectively. Outdoors, the levels of benzene and toluene in flats were 0.71 and 2.62 ppb, respectively. and 1.58 and 5.35 ppb in houses. For personal exposure, the house levels of benzene, toluene and xylene were all higher than for flats. Houses using oil for heating have significantly higher levels than flats, which use gas for heating.

Indoor and Outdoor $NO_2$ Concentration at Subway Station and Personal $NO_2$ Exposure of Subway Station Workers (지하철역사의 이산화질소 농도와 역무원의 이산화질소 개인폭로량)

  • 손부순;장봉기;박종안;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.134-141
    • /
    • 2000
  • The person' spending time in underground s[aces within indoor environment show a tendency to increase every year, but in Korea, levels and sources of pollutant in underground spaces have not been well-characterized. Therefore, as part or a larger indoor environmental study, conducted at subway station in Seoul, nitrogen dioxide was measured using passive samplers in 16 subway stations, 2 tunnels and 70 workers of subway station. The mean concentrations of nitrogen dioxide in subway stations were $27.87{\pm}7.15$ ppb at station office, $35.76{\pm}8.35$ ppb at platform, $52.60{\pm}13.04$ ppb at outdoor, respectively, and the Indoor/Outdoor ratio were 0.49~0.93. The mean concentrations of nitrogen dioxide in tunnels were $44.91{\pm}4.67$ ppb in Chunggye-Nowon tunnel with a single track, $42.55{\pm}3.33$ ppb in Mokkol-Taenung tunnel with double track, respectively, and as a result of t-test, a single track levels were higher than double track levels(p<0.05). The mean personal exposure of the subject of station workers was $29.40{\pm}9.75$ ppb.

  • PDF