• Title/Summary/Keyword: 70% alcohol solution

Search Result 50, Processing Time 0.024 seconds

Preparation of Composite Membranes Via PVA/PAM Solution Coating onto Hydrophilized PVDF Hollow Fiber Membrane and Their Pervaporation Separation of Water-ethanol Mixture (PVDF 중공사막의 표면친수화 후 PVA/PAM 용액의 코팅을 통한 복합막제조와 이의 물-에탄올계의 투과증발 분리)

  • Kim, Ji Seon;Park, Chae Young;Park, Hun Whee;Seo, Chang Hee;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.4
    • /
    • pp.312-318
    • /
    • 2013
  • Poly vinylidene fluoride (PVDF) hollow fiber membranes were hydrophilized using polyethylenimine (PEI) and p-xylylene dichloride (XDC), and poly(vinyl alcohol) (PVA) and poly (acrylic acid -co- maleic acid) (PAM) mixed solutions by varying the concentration of PAM were coated onto PVDF membrane surface. The surface coating was verified by the observation of scanning electron microscope (SEM) and the permselective characteristcs of the resulting composite membranes were tested for 90 wt% aqueous ethanol solution by the pervaporation technique. The effects of the corsslinking agent concentraion, the temperature of feed solution, and the reaction temperature on the flux and separation factors were measured. Typically, the flux, $1,480g/m^2hr$ at the reaction temperature $100^{\circ}C$, PAM 3 wt%, feed temperature $70^{\circ}C$ was obtained, on the other hand, for the separation factor, ${\alpha}_{W/E}=82$ at the conditions of the reaction temperature $100^{\circ}C$, PAM 15 wt% and feed temperature $25^{\circ}C$ was shown.

A Survey of the Radiographic Cassettes Disinfection of University Hospitals in Seoul (서울지역 대학병원의 방사선과 카세트 소독에 관한 연구)

  • Kweon, Dae-Cheol;Kim, Moon-Sun;Kim, Dong-Sung;Park, Peom
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.65-70
    • /
    • 2001
  • The purpose of this study is to prevent nosocomial infection in patients through contact of radiographic cassettes. Data were collected from radiographers working in 29 university hospitals in Seoul in February and March 2001. Radiographic cassettes were disinfected daily in 5 hospitals, weekly in 4 hospitals, monthly in 5 hospitals, bimonthly in 1 hospital and once every three months in another hospital. 12 other hospitals do not practice regular disinfections of radiographic cassettes. Gauze soaked in disinfectant solution is used in 7 hospitals while 11 hospitals used cotton and cloth soaked in disinfectant solution to clean the radiographic cassettes. 26 hospitals used 99% alcohol based disinfectant solutions while 3 hospitals used 75% alcohol based disinfectant. 26 hospitals use of intercourse cassettes outpatients and in patients. In 26 hospitals, all patients shared the same set of radiographic cassettes used in the hospitals, or in 26 hospitals, separate sets of radiographic cassettes are used for outpatients and inpatients. Separate sets of cassettes are used for ICU and inpatients in 6 others hospitals. 23 hospitals used the same sets of radiographic cassettes for all their patients. radiographic cassettes are cleaned in wash area in the study room of the radiographic department in 17 hospitals. 12 other hospitals do not have designated cleaning areas for the cassettes. All radiographers practiced hands washing with soap. All 29 hospitals surveyed have infection control committee. However, only 9 out of the 29 hospitals surveyed provided Infection disinfections control education to radiographers. Only 3 hospitals have radiographers sitting in the infection control committee. Infection management education is conducted in 63 hospitals annually, twice a year in 1 hospital and once every 3 months in 2 hospitals.

  • PDF

THE EFFECT OF REMOVAL OF RESIDUAL PEROXIDE ON THE SHEAR BOND STRENGTH AND THE FRACTURE MODE OF COMPOSITE RESIN-ENAMEL AFTER TOOTH BLEACHING (생활치 표백술 후 수종의 자유 산소기 제거제 처리가 복합 레진-법랑질 전단 접착 강도 및 파절 양상에 미치는 영향)

  • 임경란;금기연;김애리;장수미
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.399-408
    • /
    • 2001
  • Tooth bleaching has been prevailing recently for its ability to recover the color and shape of natural teeth without reduction of tooth material. However, it has been reported that bleaching procedure adversely affects the adhesive bond strength of composite resin to tooth. At the same time the bond strength was reported to be regained by application of some chemical agents. The purpose of this in vitro study was to investigate the effect of the removal of residual peroxide on the composite- enamel adhesion and also evaluated fracture mode between resin and enamel after bleaching. Sixty extracted human anterior and premolars teeth were divided into 5 groups and bleached by combined technique using of office bleaching with 35 % hydrogen peroxide and matrix bleaching with 10% carbamide peroxide for 4 weeks. After bleaching, the labial surfaces of each tooth were treated with catalase, 70% ethyl alcohol, distilled water and filled with composite resin. Shear bond strength was tested and the fractured surfaces were also examined with SEM. Analysis revealed significantly higher bond strength values. (p<0.05) for catalase-treated specimens, but water-treated specimens showed reduction of bond strength, alcohol- treated specimens had medium value between the two groups(p<0.05). The fracture mode was shown that the catalase group and the alcohol group had cohesive failure but the water sprayed group had adhesive failure. It was concluded that the peroxide residues in tooth after bleaching seems to be removed by gradual diffusion and the free radical oxygen from peroxide prevents polymerization by combining catalyst in the resin monomer. Therefore it may be possible to eliminate the adverse effect on the adhesion of composite resin to enamel after bleaching by using water displacement solution or dentin bonding agent including it for effective removal of residual peroxide.

  • PDF

Preparation and Characterization of Hydrogels of PVA and PVP Containing Chitosan by Radiation (방사선에 의한 키토산을 포함하는 PVA와 PVP 하이드로겔의 제조 및 특성)

  • 박경란;노영창
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.728-735
    • /
    • 2001
  • In this study, hydrogels from mixtures of chitosan/poly(vinyl alcohol) (PVA) and chitosan/poly(N-vinylpyrrolidone) (PVP) were prepared by ${\gamma}$-ray irradiation, and the mechanical properties such as gelation, water absorptivity and gel strength were examined to evaluate the applicability of these for wound dressing. The PVA : chitosan and PVP : chitosan ratio were in the range of 97:3 ~ 90:10, and the solid concentration of PVA/chitosan and PVP/chitosan solution were 15 wt%. Gamma irradiation with doses of 25, 35, 50, 60 and 70 kGy, was exposed to mixtures of PVA/chitosan and PVP/chitosan to evaluate the effect of irradiation dose. Gel content and gel strength increased as chitosan concentrations in PVA/chitosan and PVP/chitosan decreased, and as irradiation dose increased. Swelling degree increased as chitosan concentrations in PVP/chitosan and PVA/chitosan increased, and as irradiation dose decreased.

  • PDF

Effects of dissolution temperature on the rheological properties of polyvinyl alchol solutions in dimethyl sulfoxide

  • Cho, Yong-Han;Dan, Kyung-Sik;Kim, Byoung-Chul
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.2
    • /
    • pp.73-77
    • /
    • 2008
  • The rheological properties of polar solutions are very sensitive to preparative methods as well as measuring conditions. The effects of dissolution temperature on the rheological properties of the solutions of polyvinyl alcohol (PVA) in dimethyl sulfoxide were investigated over the range of dissolution temperatures $70-130^{\circ}C$. Viscosity was increased as dissolution temperature was increased. PVA solutions prepared at 120 and $130^{\circ}C$ showed Bingham behavior, which became less noticeable with decreasing dissolution temperature. The modified Cole-Cole plot of the solutions gave slope less than 2, suggesting the solutions were a heterogeneous system irrespective of optical transparency. Further, the slope was decreased with increasing dissolution temperature, indicating that the solid character got more prominent as dissolution temperature was increased. However, the relaxation time of the solutions was little dependent on dissolution temperature.

Study of Diffraction Efficiency Values for Photopolymer Films Added TiO2 Nanoparticles (TiO2 나노 입자를 첨가한 광고분자 필름의 회절효율 값에 대한 연구)

  • Her, Ki-Young;Kim, Dae-Heum
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.2
    • /
    • pp.123-127
    • /
    • 2009
  • In order to improve the diffraction efficiency of the photopolymer, we prepared a $TiO_2$ added photopolymer and investigated the optical properties. Prepared photopolymer films are based on polyvinyl alcohol (PVA) as a polymer binder, acryl amide (AA) as a photo-polymerizable monomer, triethanolamine (TEOA) as an initiator, and eosin Y as a sensitizer at 532 nm. To prepare the photopolymer films with the uniform thickness, the constant amount (2.5 ml) of the photopolymer solution was dropped on the glass and spread using a spin coater. Then films were dried for 72 hrs in a darkroom ($20^{\circ}C$, 40% RH) prior to the optical measurement. Then, the diffraction efficiencies of both the photopolymer films containing $TiO_2$ and non-contained films were measured with the various incident angles ($20{\sim}70^{\circ}$). Therefore, $TiO_2$ added photopolymer showed 5% higher diffraction efficiency than neat photopolymer without $TiO_2$ addition. The addition of $TiO_2$ into the photopolymer showed the high diffraction efficiency (over 70%) at broad range ($20{\sim}70^{\circ}C$) of the incident angle.

The Effect of Organic solvents on Interrupting Diapause Initiation in Prospective Diapause Eggs of Bombyx mori. (가잠란의 휴면개시조지에 관한 유기용매의 효과)

  • 김삼은
    • Journal of Sericultural and Entomological Science
    • /
    • v.27 no.1
    • /
    • pp.24-30
    • /
    • 1985
  • The effect of some organic solvents on interrupting diapause of Bombyx mori eggs was examined to provide a clue to the mechanism of diapause initiation. Methyl alcohol and benzene proved to be efficient in developing the prospective diapause eggs upto the stage of hatching or body pigmentation of the embryos. On the other hand, most of the eggs soaked in chloroform and mixture solution of chloroform-methyl alcohol (2:1) died in the early embryonic developmental stage with yellow or red brown colours, and the egg weights decreased upto ca. 40% of the original weight 8 days after the treatments. Methyl alcohol treatment for 2, 5 and 10 min to the 5hr-old-eggs led to empergence of the larvae, with high incidence (70∼80%) in the race of Kumchu X Chonghwa and with low indidence (1∼4%) in Daezo. The effect of same treatment to 20hr old eggs decreased to ca. 10% in the emergence of larvae in Kumchn X Chonghwa and increased to 20∼30% in Daezo, while the effect disappeared shortly after the diapause initiation (48hr-old-eggs). Considering the high dependency upon the egg age of the sensitivity to solvents, it was supposed that initiation and termination of diapause may be controlled by different mechanism. It was also suspected that the solvents exert their effect on the permeability of the eggshell.

  • PDF

Cytological Changes Associated with the Exposure of Escherichia coli to Several Disinfectants: An Ultrastructural Study (수종(數種) 항균제(抗菌劑) 처리(處理)에 의(依)한 Escherichia coli의 미세구조(微細構造) 변화(變化))

  • Deung, Young-Kun;Koh, Choon-Myung;Kim, Sung-Kwang
    • The Journal of the Korean Society for Microbiology
    • /
    • v.11 no.1
    • /
    • pp.1-11
    • /
    • 1976
  • An electron microscopic study has been made of the effects of change of cell structure of Escherichia coli treated with several disinfectants. The alterations observed as follows: 1. Nucleoid, cytoplasm which contain ribosomes and cell wall appeared to be composed of a parallel triple. layered membrane can observed in control Escherichia coli. 2. The nuclear material was no longer demonstrable in its normal sites. The cytoplasm lost its granularity, became homogeneous and disruption of cell wall were observed by the treatment with 70% ethyl alcohol and 3% $H_2O_2$. 3. Aggregation of ribosomes and condensation of nuclear material were also observed by the treatment of 5% lysol solution and 1% dodecyl-diamino-ethyl-glycin-hydrochloride. 4. In autoclaved group, the each layer of cell wall was separated and destroyed in some sites where cytoplasm was extracted.

  • PDF

Evaluation for Long-term Stability of EGCG Rich Green Tea Extract (EGTE) (신규 건강기능식품소재 'EGCG 고함유 녹차추출물(EGTE)'의 장기안정성 평가)

  • Cheon, Se In;Heo, Eun Ji;Yoon, Min Ji;Choi, Sang Un;Ryu, Geon-Seek;Ryu, Shi Yong
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.4
    • /
    • pp.328-335
    • /
    • 2018
  • 'EGCG(epigallocatechin gallate) rich Green Tea extract(EGTE)' was prepared by a convenient chromatographical manner using water and alcohol which was regarded as the most suitable and appropriate process for food manufacturing. The EGCG content in EGTE was estimated above 97%. Analysis of polyphenol components in green tea, i.e., catechin(C), epigallocatechin(EGC), epicatechin(EC), epigallocatechin gallate(EGCG), epicatechin gallate(ECG) and caffeine was performed by HPLC. The optimized HPLC method exhibited a good linearity of calibration curve, accuracy and precision. The long-term stability evaluation of EGTE was carried out with a powdered formulation and solution formulation by estimating the color change and measuring the EGCG content by HPLC analysis for one year. The EGCG content of the powdered EGTE stored in a transparent bottle at room temperature was retained over 97% at the end of the experimental period. The EGCG content of 0.1% water solution of EGTE stored in a transparent bottle at RT were observed to decrease below 30%, whereas that stored at $2^{\circ}C$ retained over 70%, respectively. These results suggested that a powdered formulation could be recommended for the commercialized nutraceutical product of EGTE rather than a solution formulation.

Hydrophilization of hydrophobic membrane surfaces for the enhancement of water flux via adsorption of water-soluble polymers

  • Kim, Ka Young;Rhim, Ji Won
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.101-113
    • /
    • 2016
  • In this study, to improve the water flux of porous hydrophobic membranes, various water-soluble polymers including neutral, cationic and anionic polymers were adsorbed using 'salting-out' method. The adsorbed hydrophobic membrane surfaces were characterized mainly via the measurements of contact angles and scanning electron microscopy (SEM) images. To enhance the durability of the modified membranes, the water-soluble polymers such poly(vinyl alcohol) (PVA) were crosslinked with glutaraldehyde (GA) and found to be resistant for more than 2 months in vigorously stirred water. The water flux was much more increased when the ionic polymers used as the coating materials rather than the neutral polymer and in this case, about 70% of $0.31L/m^2{\cdot}h$ (LMH) to 0.50 LMH was increased when 300 mg/L of polyacrylamide (PAAm) was used as the coating agents. Among the cationic coating polymers such as poly(styrene sulfonic acid-co-maleic acid) (PSSA_MA), poly(acrylic acid-comaleic acid) (PAM) and poly(acrylic acid) (PAA), PSSA_MA was found to be the best in terms of contact angle and water flux. In the case of PSSA_MA, the water flux was enhanced about 80%. The low concentration of the coating solution was better to hydrophilize while the high concentration inclined to block the pores on the membrane surfaces. The best coating condition was found: (1) coating concentration 150 to 300 mg/L, (2) ionic strength 0.15, (3) coating time 20 min.