• Title/Summary/Keyword: 6W2H

Search Result 2,819, Processing Time 0.038 seconds

Effect of Crystallization Treatment on the Magnetic Properties of Amorphous Strips Based on Co-Fe-Ni-B-Si-Cr Containing Nitrogen

  • Cho H.J.;Kwon H.T.;Ryu H.H.;Sohn K.Y.;You B.S.;Park W.W.
    • Journal of Powder Materials
    • /
    • v.13 no.4 s.57
    • /
    • pp.285-289
    • /
    • 2006
  • Co-Fe-Ni-B-Si-Cr based amorphous strips containing nitrogen were manufactured via melt spinning, and then devitrified by crystallization treatment at the various annealing temperatures of $300^{\circ}C{\sim}540^{\circ}C$ for up to 30 minutes in an inert gas $(N_2)$ atmosphere. The microstructures were examined by using XRD and TEM and the magnetic properties were measured by using VSM and B-H meter. Among the alloys, the amorphous ribbons of $Co_{72.6}Fe_{9.8}Ni_{5.5}B_{2.4}Si_{7.1}Cr_{2.6}$ containing 121 ppm of nitrogen showed relatively high saturation magnetization. The alloy ribbons crystallized at $540^{\circ}C$ showed that the grain size of $Co_{72.6}Fe_{9.8}Ni_{5.5}B_{2.4}Si_{7.1}Cr_{2.6}$ alloy containing 121 ppm of nitrogen was about f nm, which exhibited paramagnetic behavior. The formation of nano-grain structure was attributed to the finely dispersed Fe4N particles and the solid-solutionized nitrogen atoms in the matrix. Accordingly, it can be concluded that the nano-grain structure of 5nm in size could reduce the core loss within the normally applied magnetic field of 300A/m at 10kHz.

Repetitive operation characteristics of 500 Hz class excimer laser (500 Hz급 엑시머레이저의 반복동작특성)

  • 박홍진;이주희
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.232-237
    • /
    • 1996
  • A 500 Hz repetition rate excimer laser was developed as light source for pollution lidar. In this paper, the high repetitive output characteristics, the gas flow loop structure, and CR(clearing ratio) characteristics were investigated. Our laser system was constructed compact structure with a streamline gas flow loop and UV preionization. The real gas volume of laser is 10 liter. At 500 Hz repetitive operation, we have obtained average power of 53 watt with KrF laser gas. The variation of laser output, CR, and active volume are $\pm$6.7%, 2.3, and 2.0(H)$\times$1.2(W)$\times$56(L)=134 ㎤, respectively. Laser output power is declined to half at 3$\times$$10^6$ shots.

  • PDF

Isolation of main component and antioxidant activities on the stem and root of Rosa rugosa (해당화 줄기 및 뿌리의 주성분 분리 및 항산화활성)

  • Park, byoung-Jae
    • Korean Journal of Plant Resources
    • /
    • v.21 no.5
    • /
    • pp.402-407
    • /
    • 2008
  • Total phenol content was obtained from the stem extract of 7.8 (g/100g, D.W.) and root extract of 10.5 (g/100g, D.W.) on Rosa rugosa. S-4 and R-2 compounds were isolated from the stem and root of R. rugosa. The structure of S-4 and R-2 compounds was assigned as catechin by $^{1}H,\;^{13}C$ CNMR signal and TOF-MS. The tannin content of stem extract was 752.5 (mg/100g, D.W.) as 6.3 of gallic acid, 61.5 of epicatechin and 684.8 of catechin. The tannin content of root extract was higher about 2 times (1676.0) as 6.8 of gallic acid, 160.3 of epicatechin and 1508.5 of catechin than that of stem. It was shown that catechin was main compound in the stem and root extracts of R. rugosa. Antioxidant activities were stronger low concentration, and were not different of stem and root extracts. As the results, stem and root of R. rugosa were evaluated, as natural antioxidant resource.

Determination of Nursing Costs for Hospitalized Patients Based on the Patient Classification System (종합병원에 입원한 환자의 간호원가 산정에 관한 연구)

  • 박정호;송미숙
    • Journal of Korean Academy of Nursing
    • /
    • v.20 no.1
    • /
    • pp.16-37
    • /
    • 1990
  • A cost analysis for hospitalized patients was carried out based upon Patient Classification System(PCS) in order to determine an appropriate nursing fee. The data were collected from 21 nursing units of three teaching hospitals from April 1 to June 30, 1989. first, all of the 22,056 inpatients were classified into mildly ill(Class Ⅰ), moderately ill(Class Ⅱ), acutely ill(Class Ⅲ), and critically ill(Class Ⅳ) by the PCS which had been carefully developed to be suitable for the Korean nursing units. Second. PCS cost accounting was applied to the above data. The distribution of inpatients, nursing costs, and nursing productivity were as follows : 1) Patient distribution ranged from 45% to class Ⅰ, 36% to class Ⅱ, 15% to class Ⅲ, and 4% to class Ⅳ, the proportion of class Ⅳ in ‘H’ Hospital was greater than that of the other two hospitals. 2) The proportion of Class Ⅲ and Ⅳ in the medical nursing units was greater than that of surgical nursing units. 3) The number of inpatients was greatest on Tuesdays, and least on Sundays. 4) The average nursing cost per hour was W 3,164 for ‘S’ hospital, W 3,511 for ‘H’ hospital and W 4,824 for ‘K’ hospital. The average nursing cost per patient per day was W 14,126 for ‘S’ Hospital, W 15,842 for ‘H’ hospital and W 21,525 for ‘K’ hospital. 5) The average nursing cost calculated by the PCS was W 13,232 for class Ⅰ, W 18,478 for class Ⅱ, W 23,000 for class Ⅲ, and W 25,469 for class Ⅳ. 6) The average nursing cost for the medical and surgical nursing units was W 13,180 and W 13,303 respetively for class Ⅰ, W 18,248 and W 18,707 for class Ⅱ, W 22,303 and W 23,696 for class Ⅲ, and W 24,331 and W 26,606 for class Ⅳ. 7) The nursing costs were composed of 85% for wages and fringe benefits, 3% for material supplies and 12% for overhead. The proportion of wages and fringe benefits among the three Hospitals ranged from 75%, 92% and 98% for the ‘S’, ‘H’, ‘K’ hospitals respectively These findings explain why the average nursing cost of ‘K’ hospital was higher than the others. 8) According to a multi- regression analysis, wages and fringe benefits, material supplies, and overhead had an equal influence on determining the nursing cost while the nursing hours had less influence. 9) The productivity of the medical nursing units were higher than the surgical nursing units, productivity of the D(TS) - nursing units was the lowest while the K(Med) - nursing unit was the highest in 'S' hospital. In ‘H’ hospital, productivity was related to the number of inpatients rather than to the characteristics of the nursing units. The ‘K’ hospital showed the same trend as ‘S’ hospital, that the productivity of the medical nursing unit was higher than the surgical nursing unit. The productivity of ‘S’ hospital was evaluated the highest followed by ‘H’ hospital and ‘K’ hospital. Future research on nursing costs should be extended to the other special nursing areas such as pediatric and psychiatric nursing units, and to ICU or operating rooms. Further, the PCS tool should be carefully evaluated for its appropriateness to all levels of institutions(primary, secondary, tertiary). This study took account only of the quantity of nursing services when developing the PCS tool for evaluating the productivity of nursing units. Future research should also consider the quality of nursing services including the appropriateness of nursing activities.

  • PDF

The Comparison of the Ultra-Violet Radiation of Summer Outdoor Screened by the Landscaping Shade Facilities and Tree (조경용 차양시설과 수목에 의한 하절기 옥외공간의 자외선 차단율 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.20-28
    • /
    • 2013
  • The purpose of this study was to compare the ultra-violet(UV) radiation under the landscaping shade facilities and tree with natural solar UV of the outdoor space at summer middays. The UVA+B and UVB were recorded every minute from the $20^{th}$ of June to the $26^{th}$ of September 2012 at a height of 1.1m above in the four different shading conditions, with fours same measuring system consisting of two couple of analog UVA+B sensor(220~370nm, Genicom's GUVA-T21GH) and UVB sensor(220~320nm, Genicom's GUVA-T21GH) and data acquisition systems(Comfile Tech.'s Moacon). Four different shading conditions were under an wooden shelter($W4.2m{\times}L4.2m{\times}H2.5m$), a polyester membrane structure ($W4.9m{\times}L4.9m{\times}H2.6m$), a Salix koreensis($H11{\times}B30$), and a brick-paved plot without any shading material. Based on the 648 records of 17 sunny days, the time serial difference of natural solar UVA+B and UVB for midday periods were analysed and compared, and statistical analysis about the difference between the four shading conditions was done based on the 2,052 records of daytime period from 10 A.M. to 4 P.M.. The major findings were as follows; 1. The average UVA+B under the wooden shelter, the membrane and the tree were $39{\mu}W/cm^2$(3.4%), $74{\mu}W/cm^2$(6.4%), $87{\mu}W/cm^2$(7.6%) respectively, while the solar UVA+B was $1.148{\mu}W/cm^2$. Which means those facilities and tree screened at least 93% of solar UV+B. 2. The average UVB under the wooden shelter, the membrane and the tree were $12{\mu}W/cm^2$(5.8%), $26{\mu}W/cm^2$(13%), $17{\mu}W/cm^2$(8.2%) respectively, while the solar UVB was $207{\mu}W/cm^2$. The membrane showed the highest level and the wooden shelter lowest. 3. According to the results of time serial analysis, the difference between the three shaded conditions around noon was very small, but the differences of early morning and late afternoon were apparently big. Which seems caused by the matter of the formal and structural characteristics of the shading facilities and tree, not by the shading materials itself. In summary, the performance of the four landscaping shade facilities and tree were very good at screening the solar UV at outdoor of summer middays, but poor at screening the lateral UV during early morning and late afternoon. Therefore, it can be apparently said that the more delicate design of shading facilities and big tree or forest to block the additional lateral UV, the more effective in conditioning the outdoor space reducing the useless or even harmful radiation for human activities.

Evaluation of Three Pork Quality Prediction Tools Across a 48 Hours Postmortem Period

  • Morel, P.C.H.;Camden, B.J.;Purchas, R.W.;Janz, J.A.M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.2
    • /
    • pp.266-272
    • /
    • 2006
  • Numerous reports have evaluated the predictive ability of carcass probes for meat quality using measurements taken early postmortem or near 24 h. The intervening time period, however, has been largely ignored. In this study, the capacity of three probes [pH, electrical conductivity (EC), and grading probe light reflectance (GP)] to predict pork longissimus muscle quality (drip and cooking losses, Warner-Bratzler shear, $L^*$, n = 30) was evaluated at 45 min, 90 min, 3, 6, 12, 24, and 48 h postmortem. The strongest relationships were observed between cooking loss and 6 h EC and GP ($R^2$ = 0.66, 0.72), and $L^*$ and GP ($R^2$ = 0.57-0.66, 12-48 h). pH was most valuable early postmortem ($R^2$ = 0.63, 90 min with cooking loss). GP at 6 h most effectively ($R^2$ = 0.84) predicted a two factor (cooking loss+$L^*$) meat quality index. Results emphasize the predictive value of measures taken between 3 and 12 h postmortem.

Microshear bond strength according to dentin cleansing methods before recementation

  • Tasar, Simge;Ulusoy, Mutahhar Muhammed;Meric, Gokce
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • PURPOSE. The aim of this study was to determine the efficiency of Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser in different output powers for removing permanent resin cement residues and therefore its influence on microshear bond strength compared to other cleaning methods. MATERIALS AND METHODS. 90 extracted human molars were sectioned in 1 mm thickness. Resin cement was applied to surface of sliced teeth. After the removal of initial cement, 6 test groups were prepared by various dentin surface treatment methods as follows: no treatment (Group 1), ethylene diamine tetra acetic acid application (Group 2), Endosolv R application (Group 3), 1.25 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 4), 2 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 5) and 3.5 W Erbium, Chromium:Yttrium-Scandium-Gallium-Garnet laser irradiation (Group 6). The topography and morphology of the treated dentin surfaces were investigated by scanning electron microscopy (n=2 for each group). Following the repetitive cementation, microshear bond strength between dentin and cement (n=26 in per group) were measured with universal testing machine and the data were analyzed by Kruskal Wallis H Test with Bonferroni correction (P<.05). Fracture patterns were investigated by light microscope. RESULTS. Mean microshear bond strength ${\pm}$ SD (MPa) for each group was $34.9{\pm}17.7$, $32.1{\pm}15.8$, $37.8{\pm}19.3$, $31.3{\pm}12.7$, $44.4{\pm}13.6$, $40.2{\pm}13.2$ respectively. Group 5 showed significantly difference from Group 1, Group 2 and Group 4. Also, Group 6 was found statistically different from Group 4. CONCLUSION. 2 W and 3.5 W Erbium, Chromium: Yttrium-Scandium-Gallium-Garnet laser application were found efficient in removing resin residues.

Design and Fabrication of DLP Array Antenna for 3.5 GHz Band (3.5 GHz 대역에서 동작하는 DLP 배열 안테나의 설계 및 제작)

  • Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1037-1044
    • /
    • 2021
  • In this paper, we propose DLP(Dual Linear Polarization) array antenna for 3.5 GHz band. The proposed antenna has 1×4 array antenna and design two port network. A cross shape is inserted at the bottom of the patch for impedance matching. The size of each patch antenna is 18.85 mm(W1)×18.85 mm(L1), array antenna is designed on the FR-4 substrate, which is 236.0 mm(W)×60.2 mm(L), thickness (h) 1.6 mm, and the dielectric constant is 4.3. From the fabrication and measurement results, bandwidths of 70 MHz (3.54 to 3.61 GHz) for input port 1, 75 MHz (3.55 to 3.625 GHz) for input port 2 are obtained on the basis of -10 dB return loss and transmission coefficient S21 is under the -20 dB. Also, cross polarization between two port obtained.

Response of Armorclad Rockfish , Sebastes Hubbsi to the Attraction Lamp (유도등에 대한 우럭 , 볼락의 반응)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.1
    • /
    • pp.42-49
    • /
    • 1996
  • The author examined the response of Armorclad rockfish, Sebastes hubbsi [MATSUBARA]to the surface attracting lamps (0.5W, 0.8W, 1W) line in the experimental water tank ($550L{\times}58W{\times}73H$cm). The attraction rate was investigated in accordance with the intervals of lighting and putting out hour (1,5 minute) when each of the attraction lamps was gradually switched off after they were switched on all at once. The results are as follows : 1. Total distribution rate of fish in the illuminated section was 61.6%(mean 12.3%) in case of 1 minute interval, and 41.0%(mean 8.2%) in case of 5 minutes interval. 2. Mean distribution rate of fish at the illuminated section : \circled1Distribution rate at interval of 1 minute were 12.7% in 0.8W, 12.4% in 0.5W and 11.9% in 1 W respectively. \circled2Distribution rate at interval of 5 minutes were 9.0% in 1W, 8.6% in 0.8W and 7.0% in 0.5W respectively. 3. Attraction rates of the last section showed a little increasing as illuminating time elapsed. A difference of attraction rates according to lighting source in 1 minute interval was bigger than that in 5 minute interval. 4. Attraction rate of fish in only last section switched on : \circled1Attraction rate at interval in case of 1 minute were 52.0% in 0.8W, 46.7% in 0.5%W and 45.3% in 1W respectively. \circled2Attraction rate at interval in case of 5 minutes were 32.0% in 1W, 24.0% in 0.8W and 14.7% in 0.5W respectively.

  • PDF

A Study on the Rotary Tidal Current in the East China Sea (동지나해 어장의 회전 조류에 관하여)

  • 김진건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.2
    • /
    • pp.1-6
    • /
    • 1986
  • Even though it is well known that the tidal current in the East China Sea rotates clockwise, few report can be found about the precise pattern of it. To furnish some information available for the stow net fishermen, the author carried out the observation over 235 semidiurnal tidal cycle to investigate the pattern of the set and the rate of tidal current in the Korean fishing section 250 and 494, by reading the current meter and by tracing the corner reflectors with radar onboard the anchored obsen'ation vessel, from May 12, 1984 through February 27, 1986. The results obtained are as follows: 1. The mean semidiurnal tidal cycle was 12 h 20 m during spring tide, and 12 h 30 m during neap tide. 2. The mean interval from the calculated time of high water until the current began to set north was 2 h 30 m and 2 h 15 m in the fishing section 250 and 494 respectively, and the mean interval from the time of low water current began to set south was about 2 h 0 m in both sections. 3. In comparison of the occupied times to vary the set from one of 8 principal bearing points to the neighboring one, the shortest was while the set varied from N to NE and S to SW in the section 250 and 494 respectively. Contrary the longest was while the set varied from SE to S and from W to NW in the section 250 and 494 respectively. 4. In comparison of the rate while the set varied from one of 8 principal bearing points to the neighboring one, the fastest was while the set varied from SE to Sand NW to N in the section 250, and E to SE and W to NW in the section 494. Contrary the slowest was while the current set to NE and S W in the section 250, and N, NE and S W in the section 494.

  • PDF