• 제목/요약/키워드: 6D-Motion

검색결과 575건 처리시간 0.024초

의인성(醫因性) 말초신경병증(末梢神經病症) 치험(治驗) 1례(例) (A Case of Peripheral Neuropathy after Acupuncture)

  • 이경민;서정철;임성철;정태영;한상원
    • Korean Journal of Acupuncture
    • /
    • 제21권3호
    • /
    • pp.137-146
    • /
    • 2004
  • Objective : The purpose of this study is to report the patient with peripheral neuropathy, who improved by Oriental medical treatment. Methods : The patient was managed by acupuncture, moxibustion, physical treatment and herbal medicine. We checked digital infrared thermographic imaging(D.I.T.I.), electromyography(E.M.G.), nerve conduction velocity(N.C.V.), deep tendon reflex(D.T.R.), sensory recover area and range of motion(R.O.M.) of knee & ankle. Results : After 6 week treatment, clinical sign(the movement and sense of leg) of improvement was appeared. Also E.M.G., N.C.V., D.T.R. and D.I.T.I. was recovered to nearly normal range. Conclusion : The results suggest that combination of acupunture, moxibustion and herbal medicine is good method for treatment of peripheral neuropathy. But further studies may be required to concretely prove the effectiveness of this methods for treating peripheral neuropathy.

  • PDF

자기적 방법을 이용한 3차원 좌표 측정 (3-dimensional Coordinate Measurement by Pulse Magnetic Field Method)

  • 임윤빈;조육;허복회;손대락
    • 한국자기학회지
    • /
    • 제12권6호
    • /
    • pp.206-211
    • /
    • 2002
  • 본 연구에서는 3개의 펄스자기장발생 장치와 3-축의 탐지코일을 이용하여 3차원 좌표를 비접촉으로 측정할 수 있는 장치를 제작하였다. 펄스자기장을 만들어 주기 위하여 환 계수기와 아날로그 곱셈기를 사용하여 원하는 한 주기의 파형을 자기장발생장치의 각 축에서 만들어 질 수 있도록 하였다. 그리고 발생된 자기장 값을 거리 r에서 측정하기 위해 탐지코일에 유도된 전압을 증폭시키고 S/H증폭기로 최대 값을 측정하였다. 자기장발생 장치로부터 거리를 0.5m에서 1.5m까지 1차원과 2차원 상에서 탐지코일을 움직여 간을 측정하고 이를 거리로 환산하는 계산식에 의한 결과가 실제 거리의 값과 그 편차가 $\pm$0.5%에서 그 위치를 측정할 수 있음을 알 수 있었다.

굽힘 센서신호를 이용한 인공의수의 제어 (Control of an Artificial Arm using Flex Sensor Signal)

  • 유재명;김영탁
    • 한국지능시스템학회논문지
    • /
    • 제17권6호
    • /
    • pp.738-743
    • /
    • 2007
  • 본 연구는, 팔(하완)을 잃은 장애자용 인공 의수를 장애자가 자신의 의도에 따라 제어하기 위한 센서 시스템과 제어알고리즘에 관한 것이다. 먼저 장애자의 여러 가지 동작 의도를 검출할 수 있는 센싱 시스템을 연구하고 이 센싱 시스템으로부터 발생된 신호를 사용하여 인공의수를 제어하는 방법에 대하여 연구한다. 센서로서는 전기 저항식 굽힘 센서를 사용한다. 이 굽힘 센서를 팔의 상완 이두근과 오구완근에 각각 1개씩 단단히 부착한다. 부착된 센서로부터 출력된 신호는 근육의 굴곡량을 나타내며 팔의 동작의도를 판단 할 수 있는 신호처리 시스템을 통과시켜 하완의 굴곡과 신전 운동, 손의 내전과 외전 운동을 구별한다. 그리고 구별된 신호로부터 실제 팔의 운동 각도를 추정하여 인공의수의 각도를 제어한다. 본 연구의 효용성을 증명하기 위해 2개의 액추에이터와 포텐셔미터를 가진 간단한 인공의수를 제작하여 제어 실험을 하였다. 실험에서 실제 팔의 각도와 인공의수의 제어 각도 사이에는 센서 외부에서 발생되는 노이즈 및 인공의수의 회전 관성, 기계적인 마찰 등으로 인한 오차가 발생하였다. 따라서 오차 값과 오차의 변화 값에 근거한 퍼지 제어 알고리듬을 이용하여 재 실험을 한 결과 하완의 굴곡/신전 운동에서는 평균 약 4도, 손의 회내/외 운동에서는 평균 약 3도의 오차가 측정되어, 퍼지제어기를 설치한 이전보다 오차가 크게 개선되었다.

BoD 기반의 Steel Lazy Wave Riser(SLWR)와 계류된 FPSO와의 연성해석에 관한 수치해석 연구 (Numerical Study on the Coupled Responses of the Steel Lazy Wave Riser (SLWR) Based on the Basis of Design and Moored FPSO)

  • 권용주;남보우;박병원;오승훈;정재환;정동호
    • 한국항해항만학회지
    • /
    • 제43권6호
    • /
    • pp.344-352
    • /
    • 2019
  • 초심해역 자원개발용 라이저와 계류된 부유체와의 연성해석을 수행한다. 일반적으로 라이저의 안전성은 부유체와의 연성해석 없이 최대 offset을 고려한 해석을 통해 보수적으로 평가되는데, 본 연구에서는 계류된 부유체의 연성 운동해석을 고려하여 라이저의 안전성을 분석한다. 라이저는 초심해역에 적용되는 SLWR이 고려되며, 부유체는 FPSO가 적용된다. 연성을 고려하는 방법과 고려하지 않는 방법론에 대하여 제시한다. 계류선이 모두 안전한 정상상태(Intact) 조건과 사고(damaged) 조건을 고려하여, 각 조건에서 파랑 입사각도에 따라 연성해석 효과를 분석한다. 하중 조건에 따라 계류선의 장력, 부유체의 운동 및 라이저의 거동 등을 분석한다.

트레드밀을 이용한 보행간 Variability 분석에 관한 연구 (A Study on Stride-to-stride Variability by Treadmill Walking)

  • 최진승;강동원;탁계래
    • 한국운동역학회지
    • /
    • 제17권4호
    • /
    • pp.1-8
    • /
    • 2007
  • The purpose of this study was to investigate the difference in the stride-to-stride variability between two treadmill conditions; traditional treadmill and special treadmill whose speed can be adjusted automatically by subject's walking speed. Eight male subjects (25.1 years, 172.7 cm, 66.6 kg) were participated in treadmill walking experiment. First, preferred walking speed (PWS) of each subject was determined. Second, each subject performed walking experiment with fixed PWS condition and with free PWS condition for 10 minutes. 3D motion capture system (Motion analysis Corp., USA) with 6 cameras was used to collect motion data with sampling frequency of 120Hz. Temporal and spatial variables for stride-to-stride variability were calculated. Coefficient of variance (CV) which quantifies the amount of variability and Detrended Fluctuation Analysis (DFA) which explains the structure (self-similarity) of the variability were used for analysis. Results showed that the amount of variability during free PWS condition was greater than that of fixed PWS condition. DFA results showed that there was a statistical difference between two treadmill conditions for the variables of step length, stance time, and double support time. From these results, it is possible that traditional treadmill study might give incorrect conclusion about gait variability study. Further study is necessary to clarify these matters by considering the number of subjects, experimental time, and gait variables for the study of stride-to-stride variability.

A Novel System with EMG-controlled FES Enhanced Gait Function and Energy Expenditure for Older Adults

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung cheol Shin;Hwang-Jae Lee;Wan-hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권2호
    • /
    • pp.152-162
    • /
    • 2024
  • Objective: This study was conducted to analyze the effect of wearable Electromyography-controlled functional electrical stimulation (EMG-controlled FES) System on Gait Function and cardiopulmonary metabolic efficiency during walking in older adults. Design: Cross-section study Methods: Total 22 older adult participants suitable to selection criteria of this study participated in this study. The EMG-controlled FES System, which functions as a wearable physical activity assist FES system was used. All participations performed randomly assigned two conditions (Non-FES assist [NFA], FES assist [FA]) of walking. In all conditions, spatio-temporal parameters and kinematics and kinetics parameters during walking was collected via 3D motion capture system and 6 minutes walking test (6MWT) and metabolic cost during walking and stairs climbing was collected via a portable metabolic device (COSMED K5, COSMED Srl, Roma, Italy). Results: In Spatio-temporal parameters aspects, The EMG-controlled FES system significantly improved gait functions measurements of older adults with sarcopenia at walking in comparison to the NFA condition (P<0.05). Hip, knee and ankle joint range of motion increased at walking in FA condition compared to the NFA condition (P<0.05). In the FA condition, moment and ground reaction force was changed like normal gait during walking of older adults in comparison to the NFA condition (P<0.05). The EMG-controlled FES system significantly reduced net cardiopulmonary metabolic energy cost, net energy expenditure measurement at stairs climbing (P<0.05). Conclusions: This study demonstrated that EMG-controlled FES is a potentially useful gait-assist system for improving gait function by making joint range of motion and moment properly.

2D-Video Distrometer를 이용한 강수의 물리적 특성에 관한 사례연구 (Case Study on the Physical Characteristics of Precipitation using 2D-Video Distrometer)

  • 박종길;천은지;정우식
    • 한국환경과학회지
    • /
    • 제25권3호
    • /
    • pp.345-359
    • /
    • 2016
  • This study analyze the synoptic meteorological cause of rainfall, rainfall intensity, drop size distribution(DSD), fall velocity and oblateness measured by the 2D-Video distrometer(2DVD) by comparing two cases which are heavy rainfall event case and a case that is not classified as heavy rainfall but having more than $30mm\;h^{-1}$ rainrate in July, 2014 at Gimhae region. As a results; Over the high pressure edge area where strong upward motion exists, the convective rain type occurred and near the changma front, convective and frontal rainfall combined rain type occurred. Therefore, rainrate varies based on the synoptic meteorological condition. The most rain drop distribution appeared in the raindrops with diameters between 0.4 mm and 0.6 mm and large particles appeared for the convective rain type since strong upward motion provide favorable conditions for the drops to grow by colliding and merging so the drop size distribution varies based on the location or rainfall types. The rainfall phases is mainly rain and as the diameter of the raindrop increase the fall velocity increase and oblateness decrease. The equation proposed based on the 2DVD tends to underestimated both fall velocity and oblateness compared with observation. Since these varies based on the rainfall characteristics of the observation location, standard equation for fall velocity and oblateness fit for Gimhae area can be developed by continuous observation and data collection hereafter.

펨토초 레이저 미세가공을 위한 3차원 형상 복원 시스템의 최적설계 및 구현 (Optimal Design and Implementation of 3D Shape Restoration System for Femto-second Laser Micromachining)

  • 박정홍;이지홍;고윤호;박영우
    • 전자공학회논문지SC
    • /
    • 제43권6호
    • /
    • pp.16-26
    • /
    • 2006
  • 본 논문에서는 평판형 디스플레이 장치의 필수 구성품인 투명한 ITO(Indium-Tin-Oxide) 유리를 가공하기 위한 펨토초(Femto-second) 레이저 미세 가공의 효율을 극대화하기 위해 가공 대상체의 정보를 추출하는 시스템을 제안한다. 제안한 시스템은 레이저 스캐닝 시스템을 활용하여 펨토초 레이저빔의 초점 거리 오차와 각도 오차를 사전에 계측하고 3차원으로 형상을 복원한다. 본 시스템은 라인 스캔 레이저, 고해상도 카메라, 리니어 모션 가이드(Linear Motion Guide), 시스템 제어부로 구성되어있다. 또한 본 시스템의 모델링을 통한 카메라와 레이저의 위치와 측정 결과와의 관계를 나타낼 수 있는 민감도 지수를 정의하고, 이를 활용하여 더욱더 정확한 측정이 가능한 시스템을 설계할 수 있었다. 가공 대상체인 ITO 유리의 높이와 표면 형상을 측정하고 3차원으로 형상을 복원하여 주사 탐침 현미경(SPM)으로 얻은 결과와 비교하여 본 시스템의 성능을 검증하였다.

발목관절 피하밑주머니에 문제가 있는 뇌졸중 환자에게 의학적 운동치료가 발목 통증, 관절가동범위, 외상 후 스트레스 증상, 우울증에 미치는 영향: 사례연구 (The Effect of Medical Exercise Therapy Program on Ankle pain, Range of Motion, Stress After Traumatic Injury, and Depression in a Stroke Patient with Inflammation on Subcutaneous Bursa of Ankle Joint: Case Study)

  • 유창선;채경주
    • 대한정형도수물리치료학회지
    • /
    • 제21권2호
    • /
    • pp.53-62
    • /
    • 2015
  • Background: This study was to investigate the effect of 8-weeks medical exercise therapy on ankle pain, range of motion, stress symptom after traumatic injury, and depression, in a 51 years old stroke patient with right ankle joint inflammation. Method: The 8-weeks medical exercise therapy program was applied to 4 grades of Dosage 1 (1-3 weeks), Dosage 2 (4-5 weeks), Dosage 3 (6-7 weeks), and Dosage 4 (8 weeks) on right ankle joint inflammation in a female with right hemiplegia admitted to D hospital located in Gyeonggi-do. Result: The findings showed that visual analogue scale (VAS) scores improved from 8 to 0-1 scores, passive range of motion (ROM) increased to 5 degrees more than before, Korean-version impact of event scale-revised (IES-R-K) scores increased from 61 to 31 scores, and Korean-version beck depression inventory II (BDI-II-K) scores decreased from 51 to 17 scores. As such, the 8-week medical exercise therapy program may decrease the pain, increase ROM, improve stress after traumatic injury, and improve depression symptom. Conclusion: The presented evidence suggests that exercise and physical activity have beneficial effects on depression symptoms. It is possible to apply the medical exercise therapy for modulating pain experience and treating pain. Also, it may be effective methods to treat the psychological aspects of pain.

  • PDF

죽도 무게변화에 따른 검도 머리치기 동작의 운동학적 분석 (Kinematical Analysis on the Head Hitting Motion Based on Weight Change of Bamboo Swords)

  • 정남주;김재필;구종모
    • 한국운동역학회지
    • /
    • 제20권1호
    • /
    • pp.25-32
    • /
    • 2010
  • This study was performed to investigate the kinematic factors on the head hitting motion based on weight change of bamboo swords in kumdo. The kinematic factors, needed time per phase, COB displacement and velocity, angle(wrist, elbow, shoulder joint, hip joint, knee joint), were analyzed by the 3-D motion analysis method against 6 male middle school athletes. The results were as follows. 1. The needed time of head hitting motion based on weight change of bamboo swords was shorter when weight was heavier. 2. The COB displacement of left/right was bigger when weight was heavier. the displacement of right foot was higher at backswing phase and impact phase when weight was heavier and at impact time when weight was lighter. 3. The COB velocity was faster at impact time when weight was heavier, the velocity of sword tip was fastest for each event with bamboo sword weight of 440 g. 4. The angle of left elbow was smaller at top of backswing and impact when weight was heavier, the angle of left shoulder was bigger when weight was heavier, the right knee angle was biger at start when weight was heavier, at impact when weight was lighter.