• Title/Summary/Keyword: 6D Distance

Search Result 932, Processing Time 0.027 seconds

Effect of Distance Phoria on Stereoacuity (원거리 사위도가 입체시에 미치는 영향)

  • Chun, Young-Yun;Joo, Seok-Hee;Park, Seong-Jong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.101-105
    • /
    • 2008
  • Purpose: In this study we measured the mean value of the distance stereoacutiy for adult subjects and evaluated the variation of the distance stereoacuity according to correction of phoria using the Pola Test E-II of Carl Zeiss. Methods: We investigated the distance stereoacuity for 50 adults (male: 29, female: 21) ranging in age from 19 to 46 years using D6 Circle chart and D8 Line chart in the Pola Test E-II. Results: The mean values of the distance stereoacuity measured on the D6 Circle test and D8 Line test were 159.6 and 149.4 seconds of arc respectively. The mean variations of the distance stereoacuity according to correction of phoria in D6 Circle test were increased 43.2 seconds of arc in exophoria and 51 seconds of arc in esophoria, and those in D8 Line test were increased 42 seconds of arc in exophoria and 70.2 seconds of arc in esophoria. Conclusions: We knew from these results that the distance stereoacuity after prescription of phoria improved more esophoria than exophoria.

  • PDF

Capturing Distance Parameters Using a Laser Sensor in a Stereoscopic 3D Camera Rig System

  • Chung, Wan-Young;Ilham, Julian;Kim, Jong-Jin
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.387-392
    • /
    • 2013
  • Camera rigs for shooting 3D video are classified as manual, motorized, or fully automatic. Even in an automatic camera rig, the process of Stereoscopic 3D (S3D) video capture is very complex and time-consuming. One of the key time-consuming operations is capturing the distance parameters, which are near distance, far distance, and convergence distance. Traditionally these distances are measured by tape measure or triangular indirect measurement methods. These two methods consume a long time for every scene in shot. In our study, a compact laser distance sensing system with long range distance sensitivity is developed. The system is small enough to be installed on top of a camera and the measuring accuracy is within 2% even at a range of 50 m. The shooting time of an automatic camera rig equipped with the laser distance sensing system can be reduced significantly to less than a minute.

Characteristics of Supersonic Jet Impingement on a Flat Plate

  • 홍승규;이광섭;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2001.05a
    • /
    • pp.134-143
    • /
    • 2001
  • Viscous solutions of supersonic jet impinging on a flat plate normal to the flow are simulated using three-dimensional Navier-Stokes solver. The jet impinging flow structure exhibits such complex nature as shock shell, plate shock and Mach disk depending on the flow parameters. Among others, the dominant parameters are the ratio of the nozzle exit pressure to the ambient pressure and the distance between the nozzle exit plane and the impinging plane. In the present study, the nozzle contour and the pressure ratio are held fixed, while the jet impinging distance is varied to illuminate the characteristics of the jet plume with the distance. As the plate is placed close to the nozzle at 3D high, the computed wall pressure at or near the jet center oscillates with large amplitude with respect to the mean value. Here D is the nozzle exit diameter. The amplitude of wall pressure fluctuations subsides as the distance increases, but the maximum pressure level at the plate is achieved when the distance is about 4D high. The frequency of the wall pressure is estimated at 6.0 kHz, 9.3 kHz, and 10.0 kHz as the impinging distance varies from 3D, 4D, to 6D, respectively.

  • PDF

Characteristics of Supersonic Jet Impingement on a Flat Plate (평판에 충돌하는 초음속 제트에 유동특성)

  • Hong Seung-kyu;Lee Kwang-Seop;Park Seung-O
    • Journal of computational fluids engineering
    • /
    • v.6 no.3
    • /
    • pp.32-40
    • /
    • 2001
  • Viscous solutions of supersonic jet impinging on a flat plate normal to the flow are simulated using three-dimensional Navier-Stokes solver. The jet impinging flow structure exhibits such complex nature as shock shell, plate shock and Mach disk depending on the flow parameters. Among others, the dominant parameters are the ratio of the nozzle exit pressure to the ambient pressure and the distance between the nozzle exit plane and the impinging plane. In the present study, the nozzle contour and the pressure ratio are held fixed, while the jet impinging distance is varied to illuminate the characteristics of the jet plume with the distance. As the plate is placed close to the nozzle at 3D high, the computed wall pressure at or near the jet center oscillates with large amplitude with respect to the mean value. Here D is the nozzle exit diameter. The amplitude of wall pressure fluctuations subsides as the distance increases, but the maximum mean pressure level at the plate is achieved when the distance is about 4D high. The frequency of the wall pressure is estimated at 6.0 kHz, 9.3 kHz, and 10.0 kHz as the impinging distance varies from 3D, 4D, to 6D, respectively.

  • PDF

Study on Bearing Response of Single Lap Riveted Joint (Single Lap Riveted Joint의 베어링 거동 연구)

  • Heo Kwang-Su;Yoon Sung-Ho;Jeong Jong-Cheol;Lee Sang-Jin;Kim Jung-Seok
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.326-331
    • /
    • 2005
  • In this study, bearing response in single lap riveted joint is investigated by menas of single lap shear specimens with different types of adherend and fastener. Single lap shear specimen consists of adherend of SUS403 and carbon fabric/epoxy composite. Rivet of Avdel 2691 with 9.6mm diameter is used. Two types of fastener in single lap riveted joint are considered. One is a single lap shear specimen with single fastener, and the other is a single lap shear specimen with double fasteners. Especially, in case of single lap shear specimen with single fastener, the width of the specimen is varied as 2D, 3D, 4D, 6D at a fixed edge distance of 3D. Also the edge distance of the specimen is varied as 1.0D, 1.5D, 2.0D, 2.5D, 3.0D at a fixed width of 4D. In case of single lap shear specimen with double fasteners, two types of specimen are considered. One is a specimen with the width of 6D and edge distance of 3D. The other is a specimen with the width of 4D and edge distance of 2D. Here D designates the hole diameter for riveted joint.

  • PDF

A Study on LED Distance Recognition Measure Using Distance Measurement Correction Algorithm (거리계산 보정 알고리즘을 이용한 LED 거리 인식 측정에 관한 연구)

  • Kim, Ji-Seong;Jung, Dae-Chul;Kim, Yong-Kab
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.63-68
    • /
    • 2017
  • In this paper, Distance recognition measurement using distance calculation correction algorithm, was realization through LED dimming control. The calculation values for the RSSI average filtering and the RSSI feedback filtering were calculated and applied to reduce the error of the RSSI value measured from a long distance. It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements. A distance calculation correction algorithm to improve the accuracy was applied, which confirmed that as the distance increases, the range of errors decreases. In conclusion, unstable signals were corrected using the RSSI measurement result filtering, and the distance calculation correction algorithm was applied and performed to reduce the range of errors. In addition, RGB colors were implemented by LED to indicate the distance determination and the signal stability.

Measurement of the local heat transfer coefficient on a convex hemispherical surface with round oblique impinging jet (볼록한 표면위에 분사되는 원형경사충돌제트의 국소열전달계수 측정에 관한 연구)

  • 최형철;이세균;이상훈;임경빈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.846-854
    • /
    • 1999
  • Measurements of the local heat transfer coefficients were made on a hemispherically convex surface with a round oblique impinging jet. The liquid crystal transient method was used for these measurements. This method, which is a variation on the transient method, suddenly exposes a preheated wall to an impinging jet while video recording the response of liquid crystal for the surface temperature measurements. The Reynolds number used was 23000 and the nozzle-to-surface distance was L/d=2, 4, 6, 8, and 10 and the jet angle was $\alpha$=$0^{\circ}\; 15^{\circ}\;30^{\circ}C\; and \;40^{\circ}C$. In the experiment, the Nusselt number at the stagnation point decreases as the jet angle increases and has the maximum value for L/d=6. The X-axis Nusselt number distributions exhibit Secondary maxima at $0^{\circ}C\re $\alpha$\re 15^{\circ}C, L/d\le6$ for X/d<0(upstream) and at $0^{\circ}C\re $\alpha$40^{\circ}C,\;L/d\le4\;and\; at\; 30^{\circ}C\re $\alpha$$\leq$40^{\circ}C,\;L/d\le 6 $for X/d>0(downstream). The secondary maxima occurs at long distance from the stagnation point as the jet angle increases or the nozzle-to-surface distance decreases. The Y-axis Nusselt number distributions exhibit secondary maxima at Y/d=$\pm$2 for $0^{\circ}C\le a\le30^{\circ}C\; and\; L/d\le4, and \;for\;$\alpha$=40^{\circ}C$and L/d=2. The displacement of the maximum Nusselt number from the stagnation point increases as the jet angle increases or the nozzle-to-surface distance decreases and the maximum distance is about 0.67 times of the nozzle diameter. The ratio of the maximum Nusselt number to the stagnation Nusselt number increases as the jet angle increases.

  • PDF

A New 3D Depth Reconstruction Method Adaptive to Various Environments (환경 적응적 3D 깊이 재구성 방법)

  • Kim, Jung-Un;Kang, Hang-Bong
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.271-279
    • /
    • 2016
  • The recent development of the HD (High Definition) and UHD (Ultra High Definition) technology allowed the growth of 3D contents market. Yet the majority of the 3D contents in the market are strictly for 6.5 cm inter-ocular distance, causing various visual discomforts for the viewers who have different inter-ocular distance. Moreover, because the 3D contents are created for a fixed viewing distance, the change of the viewing distances when watching 3D contents can also cause visual conflicts. To solve this problem, we devised techniques that consider the environmental information of the viewer watching 3D contents. By analyzing the relationship between viewing distance, inter-ocular distance, and perceived depth, we created an adaptive content viewing system that reflects the viewer's environment to minimize any conflicts in watching 3D contents. From our experiments, we found that the performance of our adaptive content viewing system was reasonable.

Resonant Type Wireless Power Transfer Using an Optimized Antenna at 1m Distance (1m 거리에서 최적화된 안테나를 통한 공진방식 무선전력전송)

  • Kim, Young Hyun;Ryu, Daun;Park, Daekil;Koo, Kyung Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.3
    • /
    • pp.246-251
    • /
    • 2016
  • This paper has optimized WPT (wireless power transfer) antenna, and compared EM (electromagnetic) simulation result with measurement for the magnetic resonant type standard of A4WP (alliance for wireless power) using 6.78MHz frequency and 1m distance. Power transmission distance is affected by various factors such as system shape, antenna size, and resonator coil pitch etc, which were confirmed by the EM simulation. By simulation an optimized WPT antenna was designed for a fixed distance, and the transmission loss ${\mid}S_{21}{\mid}$ has been calculated with changing distance. Measurement was carried for the fabricated antenna, and the measured transmission loss is 1.5dB with 70% efficiency at maximum 1.3m distance compared to the simulated loss of 1.6dB with 69% efficiency

Accuracy Analysis of Satellite Imagery in Road Construction Site Using UAV (도로 토목 공사 현장에서 UAV를 활용한 위성 영상 지도의 정확도 분석)

  • Shin, Seung-Min;Ban, Chang-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.753-762
    • /
    • 2021
  • Google provides mapping services using satellite imagery, this is widely used for the study. Since about 20 years ago, research and business using drones have been expanding. Pix4D is widely used to create 3D information models using drones. This study compared the distance error by comparing the result of the road construction site with the DSM data of Google Earth and Pix4 D. Through this, we tried to understand the reliability of the result of distance measurement in Google Earth. A DTM result of 3.08 cm/pixel was obtained as a result of matching with 49666 key points for each image. The length and altitude of Pix4D and Google Earth were measured and compared using the obtained PCD. As a result, the average error of the distance based on the data of Pix4D was measured to be 0.68 m, confirming that the error was relatively small. As a result of measuring the altitude of Google Earth and Pix4D and comparing them, it was confirmed that the maximum error was 83.214m, which was measured using satellite images, but the error was quite large and there was inaccuracy. Through this, it was confirmed that there are difficulties in analyzing and acquiring data at road construction sites using Google Earth, and the result was obtained that point cloud data using drones is necessary.