• Title/Summary/Keyword: 65 system

Search Result 4,891, Processing Time 0.033 seconds

Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System (전차선로 동적특성에 따른 설치상태 분석)

  • Park, Young;Lee, Kiwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1605-1609
    • /
    • 2016
  • The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.

Development of Black Box for Home Battery Energy Storage System Connected with Solar Energy Generation (태양광발전 연계 가정용 배터리 에너지저장장치의 블랙박스 개발)

  • Kim, Sang-Dong;Park, Ji-Ho;Kim, Dong-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1295-1302
    • /
    • 2016
  • In this paper, a black box, which is provided the reliability and user safety of home battery energy storage system connected with solar energy generation, is developed. In the developed scheme, a status and diagnosis data of battery management system, power conditioning system, solar energy generation and grid is measured. This status and diagnosis data is stored and displayed in the developed black box. In addition, this status and diagnosis data is stored and displayed in a monitoring system and a smart phone of user. A performance evaluation of the developed black box is carried out using emulator of home battery energy storage system connected with solar energy generation. Consequently, the developed black box is proved its superiority of the reliability and user safety.

A Study on the Fault Analysis of the LVDC Using PSCAD/EMTDC (PSCAD/EMTDC를 활용한 LVDC 고장분석)

  • Kim, Soo-Hwan;Choi, Gyu-Wan;Moon, Jong-Fil;Kim, Tae-Hoon;Kim, Ju-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.3
    • /
    • pp.219-223
    • /
    • 2016
  • DC microgrid system is attracted attention in the world, because DC distribution system is more energy efficient than AC distribution system. To analyse the contribution effects of distributed generation(DG) in LVDC distribution system through modeling the Rectifier, DC/DC converter, Energy Storage System(ESS) and Photovoltaic(PV). using PSCAD/EMTDC. This paper analyses fault response characteristics in LVDC distribution system according to the interconnection and islanding operation of DG. Based on research results on the paper, direction for development of fault current reduction method for LVDC distribution system is suggested.

The Optimal Isolation Period of Vertically Story-added Remodeling Apartment Building with Seismic Isolation System (면진시스템을 적용한 수직증축 리모델링 공동주택의 최적 면진주기 산정)

  • Hur, Moo-Won;Lee, Yong-Hun;Lee, Sang-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.65-74
    • /
    • 2019
  • This study presents the optimal isolation period according to the number of vertically expended stories in order to provide the basic data for the application of the seismic isolation system in the vertically expended remodeling of the aged apartment. As a result of the structural analysis, the isolation period should be at least twice the primary structure in three-story vertical expansion, three times in two-story expansion, and four times in one-story expansion for the effective application of the isolation system. On the basis of the result, the efficacy of an isolation system for the actual apartment structure, which is three-story vertically expended, was analytically verified. The maximal acceleration response on the top floor reduced by 70% and 65% of the non-isolated structure in the X and Y directions respectively. Additionally, the base shear force decreased by 30% in the both directions, compared to the non-isolated structure.

CHARACTERIZATION OF A REGULAR FUNCTION WITH VALUES IN DUAL QUATERNIONS

  • Kim, Ji Eun;Shon, Kwang Ho
    • The Pure and Applied Mathematics
    • /
    • v.22 no.1
    • /
    • pp.65-74
    • /
    • 2015
  • In this paper, we provide the notions of dual quaternions and their algebraic properties based on matrices. From quaternion analysis, we give the concept of a derivative of functions and and obtain a dual quaternion Cauchy-Riemann system that are equivalent. Also, we research properties of a regular function with values in dual quaternions and relations derivative with a regular function in dual quaternions.

A Fault Calculation Method for Loop Structured Distribution Feeders (루프운전 배전선로의 고장계산 방법)

  • Hwang, Jihui;Lim, Seongil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1633-1638
    • /
    • 2016
  • Loop system arrangement in the primary distribution system has been increased for higher reliability of power supply to the customer. This paper presents a new fault calculation method for the loop structured unbalanced distribution feeders. Mathematical modeling method of the distribution system and superposition principal based fault calculation procedures are provided. In order to establish feasibility of the proposed method, various case studies have been performed using Matlab power system toolbox.

Diagnosis Engineering of Grounding System to Reduce Noise Signals (노이즈 저감을 위한 접지시스템 진단 엔지니어링)

  • Cho, Dae-Hoon;Lee, Ki-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1290-1294
    • /
    • 2016
  • In this study, we investigate the sources of system malfunctions by measuring and diagnosing various surges and noise signals from grounding systems for electrical and electronic systems and installations in order to ensure the reliability and stability of the system operations. We measured performance or structural problems detected in the grounding systems currently in operation and analyzed the measured data in order to eliminate noise currents and interferences causing the systems to malfunction and be damaged. Based on the analysis results, we proposed improving grounding systems and the wiring arrangements most appropriate for the grounding systems and carried out the installations as per the proposed engineering. We verified that the proposed engineering made the status of system operations improved by measuring the ground noise signals during the system operations and comparing them before and after improvements being carried out.

Analysis of Current Collection Performance Testing and Result of 350[km/h] Catenary System (350km/h 전차선로 집전성능 시험 및 결과 분석)

  • Heo, Yong-Seok;Lee, In-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.365-369
    • /
    • 2016
  • The 350[km/h] catenary system was successfully opened in Honam high speed line. This 350[km/h] catenary system is firstly constructed in South Korea. Therefore the current collection performance of this system should be tested and evaluated by the authority. This paper describes the testings by running of HEMU-430X train and the evaluation criteria and result analysis to determine whether the performance of the catenary is good or not as a verification of catenary-pantograph interface. In detail, the contact force by pantograph, arcs by loss of contact and uplift amount of the catenary support were measured and discussed as a category of the current collection performance.

Development and Evaluation of Advanced Telemetry System (개선된 텔레메트리 시스템 개발 및 평가)

  • 박차훈;서희돈;박종대
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.5
    • /
    • pp.513-517
    • /
    • 2000
  • In this study, we fabricated the advanced telemetry system that transmitting media use radio frequency(RF) for the middle range measurement of the physiological signals and receiving media use optical for electromagnetic interference problem. The telemetry system within a size of 65$\times$125$\times$45mm consists of three parts: a RF transmitter, a optical receiver and a physiological signal processing CMOS one chip. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum which enables a comfortable bed-side telemetry system.

  • PDF