• Title/Summary/Keyword: 64bit

Search Result 391, Processing Time 0.02 seconds

Design of Binary Constant Envelope System using the Pre-Coding Scheme in the Multi-User CDMA Communication System (다중 사용자 CDMA 통신 시스템에서 프리코딩 기법을 사용한 2진 정진폭 시스템 설계)

  • 김상우;유흥균;정순기;이상태
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.5
    • /
    • pp.486-492
    • /
    • 2004
  • In this paper, we newly propose the binary CA-CDMA(constant amplitude CDMA) system using pre-coding method to solve the high PAPR problem caused by multi-user signal transmission in the CDMA system. 4-user CA-CDMA, the basis of proposed binary CA-CDMA system, makes binary output signal for 4 input users. It produces the output of binary(${\pm}$2) amplitude by using a parity signal resulting from the XOR operation of 4 users data. Another sub-channel or more bandwidth is not necessary because it is transmitted together with user data and can be easily recovered in the receiver. The extension of the number of users can be possible by the simple repetition of the basic binary 4-user CA-CDMA. For example, binary 16-user CA-CDMA is made easily by allocating the four 4-user CA-CDMA systems in parallel and leading the four outputs to the fifth 4-user CA-CDMA system as input, because the output signal of each 4-user CA-CDMA is also binary. By the same extension procedure, binary 64 and 256-user CA-CDMA systems can be made with the constant amplitude. As a result, the code rate of this proposed CA-CDMA system is just 1 and binary CA-CDMA does not change the transmission rate with the constant output signal(PAPR = 0 ㏈). Therefore, the power efficiency of the HPA can be maximized without the nonlinear distortion. From the simulation results, it is verified that the conventional CDMA system has multi-level output signal, but the proposed binary CA-CDMA system always produces binary output. And it is also found that the BER of conventional CDMA system is increased by nonlinear HPA, but the BER of proposed binary CA-CDMA system is not changed.

Bone Marrow Immunoscintigraphy for the Detection of Skeletal Metastasis in Malignant Tumors: A Comparison with $^{99m}Tc$-MDP Bone Scan (악성종양에서 골수면역신티그라피를 이용한 골수전이의 평가 : $^{99m}Tc$-MDP 뼈스캔과의 비교)

  • Lee, Kyung-Han;Choi, Chang-Woon;Bang, Yung-Jue;Chung, Jun-Key;Chung, Hong-Keun;Lee, Myoung-Chul;Kim, Byoung-Kook;Kim, Noe-Kyeong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.89-97
    • /
    • 1994
  • Although bone scan is a highly sensitive test for detecting bone metastasis, its findings are often limited in specificity and cannot be used for assessing the bone marrow. Bone marrow scintigraphy may provide useful information but previous experience with radiolabelled colloid has been disappointing. Recently, $^{99m}Tc$ labeled anti-granulocyte monoclonal antibody (anti-NCA-95 MAb) has been introduced as a new bone marrow imaging agent. To evaluate the usefulness of $^{99m}Tc$ anti-NCA MAb bone marrow scans for detecting skeletal metastasis, bone marrow scans of 44 malignant tumor patients were evaluated and compared with bone scan findings. Bone scan showed abnormal lesions in 26(59%) cases, and 18 of these patients also had an abnormal bone marrow scan. Seven of the 8 patients who had normal bone marrow scan despite bone scan lesions were confirmed to be free from metastasis. There was one case with a marrow defect despite normal bone scan but the presence of metastasis was not determined due to loss of follow up. Bone scan demonstrated a total of 64 lesions while bone marrow scan showed 38 lesions. Fifty percent (32/64) of the bone scan lesions had matching marrow defects while the remaining 50% did not. Most of these non matched lesions were suggested to be nonspecific lesions such as rib fractures or degenerative change. Meanwhile bone marrow scan was able to detect 6 new lesions not detected by bone scan, bit metastasis in each lesion was not confirmed. Bone marrow scan was also helpful in assessing equivocal bone scan lesions to be of metastatic nature in 10 patients by demonstrating a matched marrow defect. Thus $^{99m}Tc$ anti-NCA MAb bone marrow scan can help exclude metastasis in patients with nonspecific bone scan lesions and may be able to detect metastatic lesions not seen with bone scan. It appears useful as a complementary study to bone scan in evaluating malignant tumor patients.

  • PDF

Robust DNA Watermarking based on Coding DNA Sequence (부호 영역 DNA 시퀀스 기반 강인한 DNA 워터마킹)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.2
    • /
    • pp.123-133
    • /
    • 2012
  • This paper discuss about DNA watermarking using coding DNA sequence (CDS) for the authentication, the privacy protection, or the prevention of illegal copy and mutation of DNA sequence and propose a DNA watermarking scheme with the mutation robustness and the animo acid preservation. The proposed scheme selects a number of codons at the regular singularity in coding regions for the embedding target and embeds the watermark for watermarked codons and original codons to be transcribed to the same amino acids. DNA base sequence is the string of 4 characters, {A,G,C,T} ({A,G,C,U} in RNA). We design the codon coding table suitable to watermarking signal processing and transform the codon sequence to integer numerical sequence by this table and re-transform this sequence to floating numerical sequence of circular angle. A codon consists of a consecutive of three bases and 64 codons are transcribed to one from 20 amino acids. We substitute the angle of selected codon to one among the angle range with the same animo acid, which is determined by the watermark bit and the angle difference of adjacent codons. From in silico experiment by using HEXA and ANG sequences, we verified that the proposed scheme is more robust to silent and missense mutations than the conventional scheme and preserve the amino acids of the watermarked codons.

Image Rejection Method with Circular Trajectory Characteristic of Single-Frequency Continuous-Wave Signal (단일 주파수 연속파 신호의 원형 궤도 특성을 이용한 영상 제거 방법)

  • Park, Hyung-Chul
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.4
    • /
    • pp.148-156
    • /
    • 2009
  • This paper presents a new image rejection algorithm based on the analysis of the distortion of a single-frequency continuous-wave (CW) signal due to the I/Q mismatch. Existing methods estimated the gain mismatch and phase mismatch on RF receivers and compensated them However, this paper shows that the circular trajectory of a single-frequency CW signal is distorted elliptic-type trajectory due to the I/Q mismatch. Utilizing the analysis, we propose a I/Q mismatch compensation method. It has two processing steps. In the first processing step, the generated signal is rotated to align the major axis of the elliptic-type trajectory diagram with the x-axis. In the second processing step, the Q-channel signal in the regenerated signal is scaled to align the regenerated signal with the transmitted single-frequency CW signal. Simulation results show that a receiver using the proposed image rejection algorithm can achieve an image rejection ratio of more than 70dB. And, simulation results show that the bit error rate performances of receivers using the proposed image rejection algorithm are almost the same as those of conventional coherent demodulators, even in fading channels.

CAN Data Compression Using DLC and Compression Area Selection (DLC와 전송 데이터 압축영역 설정을 이용한 CAN 데이터 압축)

  • Wu, Yujing;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.99-107
    • /
    • 2013
  • Controller area network (CAN) was designed for multiplexing communication between electronic control units (ECUs) in vehicles and thus for decreasing the overall wire harness. The increasing number of ECUs causes the CAN bus overloaded and consequently the error probability of data transmission increases. Since the time duration for the data transmission is proportional to CAN frame length, it is desirable to reduce the frame length. In this paper, a CAN message compression method is proposed using Data Length Code (DLC) and compression area selection algorithm to reduce the CAN frame length and the error probability during the transmission of CAN messages. By the proposed method, it is not needed to predict the maximum value of the difference in successive CAN messages as opposed to other compression methods. Also, by the use of DLC, we can determine whether the received CAN message has been compressed or not without using two ID's as in conventional methods. By simulations using actual CAN data, it is shown that the CAN transmission data is reduced up to 52 % by the proposed method, compared with conventional methods. By using an embedded test board, it is shown that 64bit EMS CAN data compression can be performed within 0.16ms and consequently the proposed algorithm can be used in automobile applications without any problem.

Changes in Matrix Metalloproteinase and Tissue Inhibitors of Metalloproteinase in Patients with Rotator Cuff Tears

  • Kwon, Oh-Soo;Kim, Young-Yul;Ha, Ji Yoon;Kang, Han Bit
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.64-67
    • /
    • 2014
  • Background: The purpose of this study was to determine whether in patients with rotator cuff tears a correlation exists between molecular changes and clinical parameters such as age, duration of symptom, range of motion, and tear size. Molecular changes of matrix metalloproteinase (MMP) and tissue inhibitor of metalloproteinase (TIMP) were assessed by measuring messenger RNA (mRNA) levels of the two proteins. Methods: The rotator cuff tissue from was obtained from the edge of a torn tendon revealed after debridement by a motorized shaver. Using the sample of rotator cuff tissue, the reverse transcription polymerase chain reaction was performed to quantify MMP-2 and TIMP-2 mRNA expression. To determine whether mRNA levels and the clinical variables, such as age, defect size, range of motion (ROM) of shoulder, and duration of symptoms, show any correlation, Spearman's correlation coefficients were used to test for significant differences. Results: There was an inverse correlation between the mRNA levels of MMP-2 and TIMP-2 from the torn rotator cuff tendons regardless of the clinical variables. However, comparison of mRNA levels versus clinical parameters such as age, defect size, range of motion and duration of symptoms revealed a number of findings. We found a significant correlation between age and mRNA levels of MMP-2 from torn cuffs (r = 0.513, p = 0.021). Further, we found a significant correlation between defect size in the full thickness tears and mRNA levels of MMP-2 (r = 0.454, p = 0.045). Conversely, no significant association between mRNA levels of MMP-2 and ROM or duration of symptom was found. Conclusions: Our results suggest that both MMP-2 and TIMP-2 may be involved in the disease process of rotator cuff tears. Although the level of mRNA expression of MMP-2 and TMP-2 remain constant in torn rotator cuffs irrespective of the clinical variables, their levels may be influenced by age and defect size, which could account to change in tendon degradation and the healing process.

DNA Watermarking Method based on Random Codon Circular Code (랜덤 코돈 원형 부호 기반의 DNA 워터마킹)

  • Lee, Suk-Hwan;Kwon, Seong-Geun;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.3
    • /
    • pp.318-329
    • /
    • 2013
  • This paper proposes a DNA watermarking method for the privacy protection and the prevention of illegal copy. The proposed method allocates codons to random circular angles by using random mapping table and selects triplet codons for embedding target with the help of the Lipschitz regularity value of local modulus maxima of codon circular angles. Then the watermark is embedded into circular angles of triplet codons without changing the codes of amino acids in a DNA. The length and location of target triplet codons depend on the random mapping table for 64 codons that includes start and stop codons. This table is used as the watermark key and can be applied on any codon sequence regardless of the length of sequence. If this table is unknown, it is very difficult to detect the length and location of them for extracting the watermark. We evaluated our method and DNA-crypt watermarking of Heider method on the condition of similar capacity. From evaluation results, we verified that our method has lower base changing rate than DNA-crypt and has lower bit error rate on point mutation and insertions/deletions than DNA-crypt. Furthermore, we verified that the entropy of random mapping table and the locaton of triplet codons is high, meaning that the watermark security has high level.

In-Band Full-Duplex Wireless Communication Using USRP (USRP 장치를 이용한 동일대역 전이중 무선통신 연구)

  • Park, Haeun;Yoon, Jiyong;Kim, Youngsik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.3
    • /
    • pp.229-235
    • /
    • 2019
  • The implementation of an in-band full-duplex wireless communication system is demonstrated in this study. In the analog/RF domain, the self-interference(SI) signal is reduced using a separate antenna for the transmitter and receiver paths, and most of the SI signal is canceled in the digital domain. A software defined radio(SDR) is used to implement the in-band full-duplex wireless communication system. The USRP X310 device uses transmitting and receiving antennas. By adjusting the gain of the transmitting and receiving ends of the SDR device, the magnitude of the SI signal entering the receiving antenna, and the size of the received signal from the outside, are both set to -64 dB. To verify the in-band full-duplex wireless communication performance, the source data is image and orthogonal frequency-division multiplexing is used for modulation. A WiFi standard frame with a carrier frequency of 2.67 GHz and bandwidth of 20 MHz is used. In the received signal, the SI signal is canceled by digital signal processing and the SI signal is attenuated by up to 34 dB. OFDM demodulation was impossible when the SI signal was not removed. However, the bit error rate is reduced to $2.63{\times}10^{-5}$ when the SI signal is attenuated by 34 dB, and no error is detected in the 100 Mbit data output as a result of passing through the Viterbi decoder.

Development of Digital Streamer System for Ultra-high-resolution Seismic Survey (초고해상 탄성파 탐사를 위한 디지털 스트리머 시스템 개발)

  • Shin, Jungkyun;Ha, Jiho;Yoon, Seongwoong;Im, Taesung;Im, Gwansung
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.3
    • /
    • pp.129-139
    • /
    • 2022
  • Analog-based streamers for ultra-high-resolution seismic surveys are capable of additional noise ingress in water, but the specifications cannot be expanded through interconnections. Foreign-produced digital streamers have been introduced and used primarily at domestic research institutes; however, the cost is high and smooth maintenance is challenging. This study investigates the localization of ultra-high-resolution digital streamers capable of high-resolution imaging of a geological structure. A digital streamer capable of 24-bit, 10 kHz digital sampling of up to 64 channel data was developed through research and development. Various quantitative specifications of the system were designed and developed close to the benchmark model, Geometrics' GeoEel streamer, and the number of modules that make up the system was drastically reduced, reducing development costs and making it easier to use. The field applicability of the developed streamer system was evaluated in an in situ experiment conducted in the waters around the Port of Yeong-il Bay in Pohang in April 2022.

DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER (실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구)

  • Park Kwan-Soo;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF