• Title/Summary/Keyword: 64개 기준색

Search Result 4, Processing Time 0.018 seconds

Multi-level Vector Error Diffusion Based on Primary Color Selection Considering Lightness (휘도를 고려한 기준색 선택 기반의 다단계 벡터 오차 확산법)

  • 박태용;조양호;이명영;하영호
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.5
    • /
    • pp.77-85
    • /
    • 2004
  • This paper proposes a multi-level vector error diffusion method using 64 primary colors to improve color impulse artifact in bright region. Vector error diffusion method causes color impulse artifact in bright region because we only use the Euclidean distance measure in quantization process. In order to reduce this artifact, the proposed method divides input color into chromatic color and achromatic color according to chroma value. In the case of chromatic color, input color is classified into bright region, middle bright region, and dark region according to lightness value. N candidate primary color is organized using lightness difference between input vector and 60 chromatic primary color vector in the case of bright region. Then, primary color with minimum vector norm between input vector and N candidate primary color in addition to 4 achromatic primary colors is selected as output color. As a result of experiments, the proposed method showed visually pleasing halftone output.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

The Effect of Color Filter on the Reading Ability in Teenager with Irlen-Syndrome (얼렌증후군에서 컬러필터가 읽기능력에 미치는 영향)

  • Lee, Dong-Joon;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.125-136
    • /
    • 2013
  • Purpose: The aim of this study was to investigate the effect of improving read speed with color filter or without color filter to improve reading disorder of teenager who were diagnosed as Meares-Irlen syndrome through survey inspection with Meares-Irlen syndrome visual stress (MISViS) score. Methods: MISViS subjects were selected from screening survey MISViS results given above 2.13 in the clinical criteria scores (MISViS score). Reading speed were measured quickly and efficiently the rate of reading via test in which randomly ordered common words are read aloud during a minute. Each of the subjects were worn a filter of the lowest concentration in each color filter group composed of 15 groups. Results: MISViS score of MISViS group and control group were 2.57 and 0.66, respectively. Results of reading speed with filter and without filter in MISViS group were $102.27{\pm}27.86$ wpm and $118.87{\pm}26.99$ wpm (p=0.001), respectively, as well as were $132.93{\pm}6.88$ wpm and $133.43{\pm}6.64$ wpm (p=0.131) in the normal group. Associated with error changes with filter and without filter between two groups, skipping in MISViS Group were from $0.25{\pm}0.62$ times to 0 times (p=0.191), Errors were from $1.83{\pm}1.69$ times to $0.17{\pm}0.38$ times (p = 0.004) and, repetitions were 0. skipping in control group were 0 times, errors were from $0.21{\pm}0.43$ times to $0.07{\pm}0.27$ times (p=0.336) and, repetitions were from $0.14{\pm}0.36$ times to 0 (p=0.165). The filter of blue series chosen in MISViS group had higher percentage (40%), whereas, subjects in normal group were more likely to prefer the filter of gray color (29%). Conclusions: This study showed that MISViS score have been used as a significant diagnosis for Irlen syndrome screening. This study found that wearing suitable color filter for MISViS patients were useful to improve learning with regard to reading. Unique color filter selection for MISViS subjects must be carefully considered since fit color filter are different personally.

Spawning Season and Growth of Korean Dark Sleeper, Odontobutis platycephala in Jaho Stream, Korea (자호천에 서식하는 한국고유종 동사리(Odontobutis platycephala)의 산란시기와 성장)

  • Hwa-Keun Byeon
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.148-155
    • /
    • 2024
  • This study investigated the ecological characteristics of Odontobutis platycephala at Jaho stream from January to December 2022. The riverbed structure of the species' habitat was rich in cobble and pebble. The water was deep, ranging from 22 to 153 cm, with an average of 64 cm, and the stream velocity was rapid at 0.89 (0.42-1.46) m/sec. The ratio of females to males was 1:1.02, and the total length of collected individuals ranged from 38 to 156 mm. The age according to the total length frequency distribution as of May indicated that the group with a total length of 38-69 mm was one year old, the group with 60-99 mm was two years old, the group with 100-139 mm was three years old, and the group 140-156 mm was four years or older. As a secondary gender characteristic, the genital papilla was cylindrical in females and cone-shaped with a pointed tip in males. Some females with a length ranging from 60 to 69 mm and all females 70 mm or longer were sexually mature. Some males with a length ranging from 70 to 79 mm and all males 80 mm or longer were sexually mature. The spawning season was from May to July, and the water temperature was between 17 ℃ and 28 ℃ during that period. The prosperous spawning season was June (24 ℃). The average number of eggs in the ovaries was 988 (284-2,722) per mature female, and the mature eggs were yellowish and spherical with a mean diameter of 1.46 (1.19-1.71) mm. The correlation between total length and body weight is BW=0.00000006TL3.12 with the constant a as 0.00000006 and the parameter b as 3.12. The mean condition factor (K) was 1.44 (0.96-2.26), and the slope was negative at -0.0007