• Title/Summary/Keyword: 60Hz

Search Result 1,303, Processing Time 0.027 seconds

Design of MSR for Magnetic Field Shielding of Low Frequency (저주파 자기장 차폐를 위한 자기차폐실 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.154-159
    • /
    • 2010
  • In this paper, the magnetically shielded room for low magnetic field shielding is designed and measured by fabricated. The size of magnetically shielded room was 3.0[m](W)$\times$3.0[m](L)$\times$3.0[m](H) to enter the industrial measuring instruments and analyzed DC and AC shielding characteristics of magnetic materials with a high permeability and AC shielding characteristics by eddy current of conductive materials. As a results, shielded room dimensions were obtained. To verify the analysis results, magnetically shielded room is fabricated and the calculated results are compared with the measured results. The Measured results show good agreement with calculated results. According to measurements, 5 times of 0.1[Hz] and 86 times of 60[Hz] is achieved at low frequency. The fabricated shielding room can be used as the magnetically shielding room for low magnetic field shielding.

A Study on Power Conversions of the Power Supply for Fire Safety Use (소방용 전원장치의 전력변환에 관한 연구)

  • Kwon, Seong-Pil;Lee, Jang-Won;Yook, Gil-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.462-465
    • /
    • 2011
  • 최근 우리나라에서는 대형 화재사고가 빈번히 발생함에 따라 그로 인한 재산 및 인명피해가 날로 증가하고 있는 실정이다. 따라서 건축물 내에서 화재가 발생할 경우 인명피해를 최소화하기 위하여 피난유도설비의 설치를 의무화하고 있다. 지금까지 일반적으로 가장 널리 사용되고 있는 피난유도설비로는 유도등이 있으며, 최근 들어 피난유도선의 설치도 다중이용업소를 중심으로 점차 확대되어가고 있는 추세이다. 피난유도설비는 평상시 이용되는 교류 상용전원에 의해서뿐만 아니라 비상시 이용되는 직류 비상전원에 의해서도 정상적으로 작동되어야 하기 때문에, 피난유도설비의 전원장치는 주어진 전원으로부터 주어지는 교류 또는 직류를 발광부에 맞게 일정한 전압과 주파수로 변환시켜주어야 한다. 실제로 LED(발광다이오드) 유도등은 상용전원으로부터 220V의 교류를 받아서 전원장치에서 정류변환을 통해 얻어지는 낮은 전압 24V의 직류를 이용하며, 대부분의 유도등 백라이트로 사용되고 있는 CCFL(냉음극형광램프)에는 상용전원으로부터 220V, 60Hz 교류를 인가받아 전원장치에서 정류 역변환을 통해 만들어진 100kHz의 고주파 교류가 공급된다. 더욱이 유도선의 전원장치에서는 상용전원 220V, 60Hz의 교류를 인가받아 정류 역변환 및 교류변환 과정을 차례로 거쳐 최종적으로 100V, 400Hz의 교류로 전환하여 TFEL(박막전계발광) 소자로 전송하게 된다. 한편, 상용전원이 차단된 상태에서도 전원장치는 마찬가지로 비상전원으로부터 24V의 직류를 공급받아 인버터를 통해 역변환 하여 100kHz의 고주파 교류를 만들어 주거나 추가적인 교류변환을 거쳐 100V, 400Hz의 교류로 변환시켜 내보낸다. 본 연구에서는 상대적으로 복잡한 전력변환 회로들을 포함하고 있는 유도선의 전원장치를 개선하여, 전원장치의 연결가능길이를 기존의 60m에서 최대 100m까지 연장시킴으로써, 터널이나 지하도와 같은 곳에서 특히 경쟁력을 갖게 될 것으로 기대된다.

  • PDF

Turbine Efficiency Measurement of Pulsating Flow in a Twin Scroll Turbocharger (맥동 유동이 있는 트윈 스크롤 터보과급기의 터빈 효율 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.386-391
    • /
    • 2021
  • Turbocharging is becoming a key technology for both diesel and gasoline engines. Regarding gasoline engines, turbocharging can help reduce carbon dioxide (CO2) emissions when used in conjunction with other technologies. This paper presents measurements of the turbine efficiency of pulsating flow in a twin-scroll turbocharger for gasoline engines. A cold gas test bench with a pulse generator was manufactured. The turbine efficiencies were calculated using the measured data of the instantaneous pressure and temperature of the inlet and exit of the turbine. The measurements were carried out at turbine speeds from 60,000 to 100,000 rpm under a pulsating flow of 25.0 Hz and 33.0 Hz. The turbine efficiencies ranged from 0.517 to 0.544. At the pulse frequency, 33.3 Hz, the variations in efficiency were 7.7% and 2.6% at turbine speeds of 60,000 rpm and 100,000 rpm, respectively. The turbine efficiency of the pulsating flow compared to those of steady flow was 7.0% and 3.0% lower at a turbine speed of 60,000 rpm and 100,000 rpm, respectively. The pulsating flow deteriorated the turbine efficiency, but the effects of pulsating flow decreased with increasing turbine speed.

A study on Protection Coordination Method for Electric Vehicle Charging Facility based on the Wireless Power Transmission (무선전력전송 전기충전설비용 전원공급장치의 최적운용방안에 관한 연구)

  • Ryu, Kyung-Sang;Kim, Byungki;Kim, Dae-Jin;Jang, Moon-Seok;Rho, Daeseok;Ko, Hee-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.42-51
    • /
    • 2017
  • This paper deals with the power supply facility providing wireless power transmission for a type of electric vehicles called the on-line electric vehicle(OLEV) and proposes optimal protection coordination methods which analyze the faultsin the 60Hz and 20kHz bands using PSCAD/EMTDC, which is the typical commercial software for the distribution system. The simulation results show that the proposed methods can reduce the fault current by introducing an NGR (Neutral Ground Resistor) in the 60Hz band and prevent the malfunctioning of the protection device by installing a CT in the neutral wire in the 20kHz band when a ground fault occurs.

Changes in Heating Profiles of Apple Juice by Ohmic Heating (통전가열(Ohmic Heating) 처리조건에 따른 사과주스의 가열속도 변화)

  • Kim, Kyung-Tack;Choi, Hee-Don;Kim, Sung-Soo;Hong, Hee-Do
    • Applied Biological Chemistry
    • /
    • v.41 no.6
    • /
    • pp.431-436
    • /
    • 1998
  • The optimum ohmic heating condition of apple juice was investigated with model solution. The temperature rise of model solution was found to be $7.8,\;21.0,\;47.4^{\circ}C/min$ when the distances between electrodes were 29, 22, and 17mm, respectively. The heating rate increased proportionally with the numbers of electrode pairs, 1 to 3 and highly dependent on applied voltage. The heating rate was not affected by the frequencies ranged from 60 Hz to 60 KHz and the wave form of applied alternating electric current. The apple juices prepared by ohmic heating sterilization revealed similar physicochemical properties to that by commercial sterilization.

  • PDF

A Study on the Comparison of the Vibration Data in Cast Resin Transformer According to the Load Type (부하 형태에 따른 몰드변압기에서의 진동데이터 비교에 관한 연구)

  • Shong, Kil-Mok;Choi, Myung-Il;Kim, Young-Seog;Bang, Sun-Bae;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.4
    • /
    • pp.75-81
    • /
    • 2012
  • In this study, vibration characteristics in according to the load type of cast resin transformer using vibration measurement device were compared. Measurement conditions are the same installation and operation of the three-phase cast resin transformer. If the load increases in transformer using the rotating machinery, the frequency is growing. In the transformer using the lighting and heating loads, it's detected the 55 [${\mu}m/s$] in or outside and 120 [${\mu}m/s$] or more at 60[Hz], the 30 [${\mu}m/s$] in or outside at 120[Hz], and the 70 [${\mu}m/s$] in or outside at 420[Hz]. When increases the loads, it's appeared the 60 [${\mu}m/s$] or less at 450[Hz] or more in rotating machinery, but the velocity of lighting and lighting loads are appeared from 5[${\mu}m/s$] to 115[${\mu}m/s$] inside the 420[Hz] in the same load condition of 20[%]. Through this study, it's verified that there are differences the internal vibration in according to the type of load in cast resin transformer.

A Study on the Calculation of Reference Impedances in Domestic Low-Voltage Power System (저압설비 플리커 특성평가를 위한 국내 저압계통 기준 임피던스 산정 연구)

  • Kang, Moon-Ho;Song, Yang-Hoe;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1651-1655
    • /
    • 2011
  • The reference impedances which is about 95% supply impedance value of residential consumers' supply impedances was published by IEC in 1980. The reference impedances are the standard values for use in determining the voltage disturbance characteristics of electrical equipment like the flicker. In IEC 60725, the reference impedances for premises having service current capacities less than 100A per phase and for service current capacities more than 100A per phase are recommended. And these reference impedances are targeted for the countries using 50Hz power frequency. Because of the frequency difference, the reactance values of the reference impedances will be increased in 60Hz power system like Korea, And also the reference impedances are different significantly each other according to declared voltage variation, power consumption and service wire length etc. Therefore It is needed to calculate the reference impedances suitable for domestic low-voltage power system. In this paper, the reference impedances for service current capacities less than 100A in 220/380V, 60Hz single-phase two wire and three-phase four wire low-voltage system are calculated, And the equations for service current capacities more than 100A to calculate the modulus value of maximum supply impedances are suggested base on IEC 60725 and the reference impedances for those are calculated on service current of 100A per phase.

Blue Electroluminescent Properties of ZnS:Cu and Dependence of Dye Addition (ZnS:Cu의 청색 전계 발광 특성과 안료 혼합 의존성)

  • Lee, Jong-Chan;Park, Dae-Hui
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.1
    • /
    • pp.1-4
    • /
    • 2002
  • To obtain the blue emission of powder electroluminescent device, the emission properties of ZnS:Cu were estimated by the variation of applied frequency and the addition of dye to ZnS:Cu phosphor. The variation of applied frequency was from 400 to 4kHz and the addition ratio of dye was from 0 to 5 weight percent respectively. The increment of applied frequency made that emission peaks were shifted from 500.5nm and 460nm at 400Hz to 490nm and 450nm at 4kHz. CIE coordinate system was shifted from x=0.1647, y=0.3711 at 400Hz to x=0.1543, y=0.1856 at 4kHz. On the basis of applied voltage 100V, 400Hz, the increment of addition ratio of dye also made that emission peak was shifted from 505nm(0wt%) to 490nm(5wt%) and the CIE coordinate system was shifted from x=0.1647, y=0.3711(0wt%) to x=0.1334, y=0.2363 (5wt%). The brightness was increased from 60 cd/$m^2$(400Hz) to 174 cd/$m^2$(4kHz) with increment of frequency. When the addition ratio of dye was above 1wt%, the brightness was decreased below 42% of initial brightness and changed from 60 cd/$m^2$(0wt%) to 20.84 cd/$m^2$(5wt%).

Frequency Dependence of Impedance of the Grounding Grid (접지그리드의 접지임피던스의 주파수 의존성)

  • 이복희;이동문;엄주홍;김교운
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.22-28
    • /
    • 2003
  • This paper describes the frequency dependence of the grounding impedance. In order to propose the evaluation method of the transient response of powered grounding systems, the grounding impedances were measured with varying the frequency of incoming currents by way of the variable frequency inverter and band pass filter. The magnitude and phase of the grounding impedance were analyzed in the frequency range of 20 [Hz]∼2.1[kHz]. The grounding impedance were increased with increasing the frequency of the test current. The grounding impedance at the frequency of 2[kHz] in the actual 22.9[kV] substation grounding system was approximately 3 times as large as the 60[Hz] grounding impedance. It was found that the frequency dependence of the grounding impedance is mainly subject to the inductive reactance of the grounding conductors. As a result, it is critical to determine the shape and size of grounding grid reducing the resultant inductance in grounding systems for lightning surge protection.

A study on calibration for commercial split beam echosounder using the bottom backscattering strength from a fishing vessel near the South Shetland Islands, Antarctica (남극 남쉐틀랜드 군도 주변 해저면 음향신호를 이용한 상업용 어군탐지기 보정 연구)

  • CHOI, Seok-Gwan;LEE, Hyungbeen;LEE, Kyounghoon;LEE, Jaebong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.4
    • /
    • pp.318-324
    • /
    • 2016
  • Commercial split beam echosounder (ES70) installed on a krill fishing vessel was calibrated in order to utilize it in estimating biomass of Antarctic krill (Euphausia superba). The method of calibration was to analyze the difference between the bottom backscattering strength of the commercial split beam echosounder (i.e. ES70) and the scientific echosounder (i.e. EK60) at one of transects near South Shetland Islands designated by CCAMLR. 38 kHz and 120 kHz were used for the calibration, and krill swarm signal levels obtained from multi frequencies, was examined to verify the calibration result. The analysis result indicated possibility of calibration by bottom backscattering strength, since the proportion of krill swarm signals within 2 dB < $S_{V\;120\;kHz-38\;kHz}$ < 12 dB (i.e. a common $S_{V\;120\;kHz-38\;kHz}$ range of 38 kHz and 120 kHz to be an indicator of Antarctic krill) over the total acoustic signals were 26.95% and 92.04%, respectively before and after the calibration.