• Title/Summary/Keyword: 60Hz

Search Result 1,303, Processing Time 0.027 seconds

Power Line Noise Reductions in ABR by Properly Chosen Iteration Numbers (ABR에서 반복회수 설정에 의한 전력선 잡음의 제거)

  • 안주현;김수찬;남기창;심윤주;김희남;송철규;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.241-247
    • /
    • 2001
  • ABR(auditory brainstem response) is one of the audiometry which measures objective hearing threshold level by acquiring electric evoked potentials emanated from auditory nerve system responding to an auditory stimulation. However, the obtained potentials which are largely interfered by power line noise, have extremely low SNR, thus ensemble average algorithm is generally used. The purpose of this study was to investigate the effect of iteration number in ensemble average on the reduction of the power line noise. The power line noise was modeled to be a 60 Hz sinusoidal signal and the energy of the modeled signal was calculated when it was averaged. It was verified by simulation that the energy had the periodic zero points for each stimulation rate, and 60 Hz signal induced by the power line was applied to the developed ABR system to confirm that the period of zero energy point was the same with that of the simulation. By the properly selected iteration number, power line noise could be reduced and more reliable ABR could be acquired.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

A study on the adjusting output energy of the CO2 laser controlled directly in AC power line (상용전원을 제어하는 CO2레이저의 출력 조절에 관한 연구)

  • Jeong, Jong-Jin;Lee, Im-Geun;Choi, Jin-Young;Park, Sung-Jin;Song, Gun-Ju;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2138-2139
    • /
    • 2005
  • We demonstrate a simple CO2 laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from 45 to 135. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of 90.

  • PDF

A Design Of Cross-Shpaed CMOS Hall Plate And Offset, 1/f Noise Cancelation Technique Based Hall Sensor Signal Process System (십자형 CMOS 홀 플레이트 및 오프셋, 1/f 잡음 제거 기술 기반 자기센서 신호처리시스템 설계)

  • Hur, Yong-Ki;Jung, Won-Jae;Lee, Ji-Hun;Nam, Kyu-Hyun;Yoo, Dong-Gyun;Yoon, Sang-Gu;Min, Chang-Gi;Park, Jun-Seok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.152-159
    • /
    • 2016
  • This paper describes an offset and 1/f noise cancellation technique based hall sensor signal processor. The hall sensor outputs a hall voltage from the input magnetic field, which direction is orthogonal to hall plate. The two major elements to complete the hall sensor operation are: the one is a hall sensor to generate hall voltage from input magentic field, and the other one is a hall signal process system to cancel the offset and 1/f noise of hall signal. The proposed hall sensor splits the hall signal and unwanted signals(i.e. offset and 1/f noise) using a spinning current biasing technique and chopper stabilizer. The hall signal converted to 100 kHz and unwanted signals stay around DC frequency pass through chopper stabilizer. The unwanted signals are bloked by highpass filter which, 60 kHz cut off freqyency. Therefore only pure hall signal is enter the ADC(analog to dogital converter) for digitalize. The hall signal and unwanted signal at the output of an amplifer and highpass filter, which increase the power level of hall signal and cancel the unwanted signals are -53.9 dBm @ 100 kHz and -101.3 dBm @ 10 kHz. The ADC output of hall sensor signal process system has -5.0 dBm hall signal at 100 kHz frequency and -55.0 dBm unwanted signals at 10 kHz frequency.

Transient Grounding Impedance Characteristic Analysis of a Copper Rod-type Grounding Electrode Used for Electric Distribution Systems Using MATLAB Program (MATLAB 프로그램을 이용한 배전계통에 사용되는 동봉 접지전극의 과도 접지임피던스 특성 분석)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Lee, Kyu-Jin;Shim, Keun-Bo;Choi, Jong-Kee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.40-46
    • /
    • 2009
  • Although a ground resistance is a good index of grounding performance for grounding electrodes, it does not reflect the grounding performance during transient state. A copper rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the grounding impedance of copper rods has been measured in frequency raging from 60[Hz] up to 100[kHz] and an equivalent model of the grounding impedance is identified from the measured values. The grounding impedance under study when a typical lightning surge is injected into the grounding system was simulated numerically and graphically through the use of the MATLAB software program.

Ground Impedance Characteristics Analysis of a Copper Rod-type Grounding Electrode used for Electric Distribution Systems (배전계통에 사용되는 동봉 접지전극의 접지 임피던스 특성 분석)

  • Kim, Kyung-Chul;Lee, Joo-Hong;Jin, Seong-Eun;Oh, Jung-Suk;Park, Sang-Young;Choi, Jong-Ki;Kim, You-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.46-51
    • /
    • 2005
  • Grounding insures a reference potential point for electric devices and also provides a low resistance path for fault currents in the earth. The ground impedance as a function of frequency is necessary for determining its performance since fault currents could contain a wide range of frequencies. A cower rod electrode is the most commonly used grounding electrode in electric distribution systems. In this paper, the ground impedance of cower rods has been measured in frequency ranging from 60[Hz] up to 100[kHz] and an equivalent circuit model, transfer function model of the ground impedance are identified from the measured values.

A Study Iron Losses On the Cable Racks adjacent to Under Ground Power Cable (지중전력 케이블에 근접한 지지물의 철손에 관한 연구)

  • 전승구;김기흥
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.3
    • /
    • pp.71-77
    • /
    • 1996
  • This paper is described on the eddy current for a peripheral magnetic objects of under ground power cable. The materials of cable rack is used FRP and SUS in the place of iron. Each specimen were measureed for eddy current loss and Hysteresis loss by Epstein's method. The results is compared each other. Hysteresis loss is inversely proportional to $\textrm{f}^{0.6}$ of frequence as supply voltage is constant. Also, iron loss is increased to 0.86 times for varinace of frequency from 60[Hz] to 50[Hz] as a maxium flux density is constant. In the case of Fe, Hysteresis loss is above 70[% ] of total iron loss. In the other hand, SUS is decreased to go[%] of Fe. by the simulation results using Loss Program Package. The iron loss of materials SUS, FRP is near zeor by Epstein's method.

  • PDF

Hearing Ability of Conger eel Conger myriaster caught in the Coast of jeju Island (제주 연안에서 어획된 붕장어의 청각 능력)

  • Ahn, Jang-Young;Park, Yong-Seok;Choi, Chan-Moon;Kim, Seok-Jong;Lee, Chang-Heon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.479-486
    • /
    • 2012
  • In order to obtain the fundamental data about the behavior of conger by underwater audible sound, this experiment was carried out to investigate the hearing ability of Conger eel Conger myriaster which was in the coast of Jeju Island by heartbeat conditioning method using pure tones coupled with a delayed electric shock. The audible range of conger eel extended from 50Hz to 300Hz with a peak sensitivity at 80Hz including less sensitivity over 200Hz. The mean auditory thresholds of conger eel at the frequencies of 50Hz, 80Hz, 100Hz, 200Hz and 300Hz were 105dB, 92dB, 96dB, 128dB and 140dB, respectively. The positive response of conger eel was not evident after the sound projection of over 200Hz. At the results, the sensitive frequency range of conger eel is narrow in spite of swim bladder. Auditory masking was determined for Conger eel by using masking stimuli with the spectrum level range of about 60~70dB (0dB re $1{\mu}Pa/\sqrt{Hz}$). According to white noise level, the auditory thresholds increased as compared with thresholds in a quiet background noise including critical ratio at 68dB of white noise from minimum 26dB to maximum 30dB at test frequencies of 80Hz and 100Hz. The noise spectrum level at the start of masking was distributed at the range of about 68dB within 80~100Hz.

Comparative Study on the Acoustic Characteristics of the Korean Vowel /a/ before and after LMS (후두미세수술 전후 /아/의 음향적 특성 비교)

  • Hwang, Yeon-Sin;Seong, Cheol-Jae
    • MALSORI
    • /
    • no.67
    • /
    • pp.33-60
    • /
    • 2008
  • The aim of this study is to show the differences in acoustic parameters between a pathological voice /a/ caused by vocal polyp and a normal voice /a/ produced after LMS (Laryngeal Microscopic Surgery). It was expected that voices of two kinds could be analyzed effectively in terms of HNR in specific frequency bands than in all frequency bands. For this study, 10 patients' voice were recorded before and after LMS and then were manipulated in terms of four acoustic parameter. It was found out that (a) frequency bands of 500Hz in the range of 1,000Hz to 4,000Hz were very useful to obtain HNR values; (b) frequency bands in the range of 1,248Hz to 5,500Hz on a log scale were very useful to obtain HNR values; (c) F0 dropped after LMS but not significantly; (d) the bandwidth of the second formant (B2) decreased significantly after LMS, while that of the first formant (B1) decreased after LMS but not significantly.

  • PDF

120Hz Ripple component minimization method of LED Drive Power Supply (LED 조명용 전원장치의 120Hz 리플성분 저감 기법)

  • Park, H.Y.;Jung, J.H.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.87-88
    • /
    • 2014
  • 조명용 LED의 보급확산에 따라 LED 구동용 전원장치에 대한 수요가 급증하고 있는데, 심각한 문제 중의 하나는 전원장치의 수명이 LED 수명에 비해 매우 짧다는 것이다. 이 문제를 해결하기 위해 전원장치에 포함되어 있는 전해커패시터를 없애야 한다. 또 다른 문제는 전원장치의 60Hz의 교류전원을 정류하여 회로를 구성해야 하는 특성상 120Hz 리플성분 때문에 플리커가 발생할 수 있다. 따라서 본 연구에서는 전해커패시터를 없앤 조명용 LED 전원장치를 제안하고 120Hz 리플성분에 의한 플리커를 최소화하기 위한 방안도 제시하고자 한다.

  • PDF