• Title/Summary/Keyword: 60 MeV

Search Result 210, Processing Time 0.031 seconds

Quantitative Analysis about Phenolic Compounds of Dendranthema Species in Korean Native Plants (국내 자생 구절초속 중 페놀화합물 함량분석)

  • Kim, Kyeong Mi;Lee, Seon Yu;Jo, Ara;Kang, Byoung Man;Ham, Seongho;Cho, Junghee;Lee, Gukyeo
    • Korean Journal of Pharmacognosy
    • /
    • v.48 no.1
    • /
    • pp.70-76
    • /
    • 2017
  • Dendranthema spp are distributed in various regions in Korea. This report is the quantitative results of phenolic compounds on the 5 resources collected from all over the country. It was known that it has phenolic compounds, as an anticoagulant activities and immunoadjuvant activity of contribute to the cardiovascular effects. This was used for quantitative analysis of chlorogenic acid(CA), 3,5-Dicaffeoylquinic acid(3,5-DCA), 4,5-Dicaffeoylquinic acid(4,5-DCA) and linarin, with UPLC-PDA and LC-IT-TOF-MS. Extraction efficiency of compounds was compared by using ultrasonic extraction and reflux extraction with different extraction conditions (methods and time). In 50% MeOH extracs (30 mins) of Dendranthema zawadskii (Herb.) Tzvelev (SDZ), Dendranthema zawadskii var. yezoense (Maek.) Y.M.Lee & H.J.Choi (NDZ), Dendranthema zawadskii (Herb.) Tzvelev var. teuisectum (Kitag.) J. H. Pak (GDZ), Dendranthema careanum (H. $L{\acute{e}}v$. & Vaniot) Vorosch. (HDC) and Dendranthema zawadskii var. tenuisectum Kitag (PDZ), chlorogenic acid contents were 1.14‰, 6.95‰, 7.27‰, 1.47‰ and 2.64‰, 3,5-dicaffeoylquinic acid contents were 3.30‰, 5.60‰, 10.81‰, 2.67‰ and 1.50‰, 4,5-dicaffeoylquinic acid contents were 0.74‰, 1.93‰, 3.36‰, 0.61‰ and 0.43‰ and linarin contents were 3.90‰, 10.15‰, 0.15‰, 0.73‰ and 0.21‰, respectively.

Plasma Phosphoproteome and Differential Plasma Phosphoproteins with Opisthorchis Viverrini-Related Cholangiocarcinoma

  • Kotawong, Kanawut;Thitapakorn, Veerachai;Roytrakul, Sittiruk;Phaonakrop, Narumon;Viyanant, Vithoon;Na-Bangchang, Kesara
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1011-1018
    • /
    • 2015
  • This study was conducted to investigate the plasma phosphoproteome and differential plasma phosphoproteins in cases of of Opisthorchis viverrini (OV)-related cholangiocarcinoma (CCA). Plasma phosphoproteomes from CCA patients (10) and non-CCA subjects (5 each for healthy subjects and OV infection) were investigated using gel-based and solution-based LC-MS/MS. Phosphoproteins in plasma samples were enriched and analyzed by LC-MS/MS. STRAP, PANTHER, iPath, and MeV programs were applied for the identification of their functions, signaling and metabolic pathways; and for the discrimination of potential biomarkers in CCA patients and non-CCA subjects, respectively. A total of 90 and 60 plasma phosphoproteins were identified by gel-based and solution-based LC-MS/MS, respectively. Most of the phosphoproteins were cytosol proteins which play roles in several cellular processes, signaling pathways, and metabolic pathways (STRAP, PANTHER, and iPath analysis). The absence of serine/arginine repetitive matrix protein 3 (A6NNA2), tubulin tyrosine ligase-like family, member 6, and biorientation of chromosomes in cell division protein 1-like (Q8NFC6) in plasma phosphoprotein were identified as potential biomarkers for the differentiation of healthy subjects from patients with CCA and OV infection. To differentiate CCA from OV infection, the absence of both serine/threonine-protein phosphatase 2A 56 kDa regulatory subunit beta isoform and coiled-coil domain-containing protein 126 precursor (Q96EE4) were then applied. A combination of 5 phosphoproteins may new alternative choices for CCA diagnosis.

Nutrient Intake and Utilization by Range Managed Sheep in Critical Physiological Stages Maintained on Grazing with Concentrate Supplementation in a Hot Semi-Arid Environment

  • Karim, S.A.;Santra, A.;Sharma, V.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.9
    • /
    • pp.1228-1234
    • /
    • 2000
  • The reported study was conducted on range managed Malpura ewes that were non-breeding empty, were at an advanced stage of pregnancy, and were in early lactation, under a protocol of free grazing with concentrate supplementation at 1.00, 1.25 and 1.50% of their body weight to assess their plane of nutrition and nutrient intake. The biomass yield of pasture plots was 1689, 1820 and 2912 kg/ha in pregnancy, lactation and empty phases, respectively. In addition to natural shrubs and forbs, Cenchrus ciliaris (36.4%) and dead litter (31.6%) were the major component of pasture vegetation during pregnancy. The dead litter disappeared during the lactation and empty phase with a concomitant increase in distribution of Cenchrus ciliaris to 73.0 and 87.2% respectively. The daily dry matter consumption from supplemental concentrate and free grazing was 70.1, 57.3 and 63.5 g/kg $W^{0.75}/d$ with concentrate to roughage ratio of 40:60, 47:53 and 33:67 in pregnancy, lactation and empty phases respectively. Digestibility of DM and OM were similar in the three phases while CP digestibility was higher (p<0.0l) during lactation than other two phases. Digestibility of NDF, ADF and cellulose were higher (p<0.0l) in empty than pregnancy and lactation, while hemicellulose digestibility was similar in lactation and empty and lower in pregnancy phase. The ewes in ~hases of pregnancy, lactation and empty consumed 7.1, 7.7 and 6.1 g DCP and 197.2, 214.6 and 232.5 kcal DE/kg $W^{0.75}/d$ respectively. It is concluded that ewes maintained on semi-arid Cenchrus dominated pasture with concentrate supplementation during pregnancy, lactation and empty phases consumed 45.2, 45.1 and 35.2 g DCP/Mcal ME respectively.

Application of electron beam irradiation for studying the degradation of dye sensitized solar cells (전자선 조사를 통한 염료감응형 태양전지의 분해 연구)

  • Akhtar, M.Shaheer;Lee, Hyun-Cheol;Min, Chun-Ji;Khan, M.A.;Kim, Ki-Ju;Yang, O-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.179-182
    • /
    • 2006
  • The effect of electron beam irradiation on dye sensitized solar cell (DSSC) has been studied to examine degradation of DSSC. The high-energy electron beam irradiation affects on the materials and performance of dye sensitized solar cells. We have checked the effects of electron beam irradiation of $TiO_2$ substrate with and without dye adsorption on the photovoltaic performances of resulting DSSCS and also studied the structural and electrical properties of polymers after irradiation. All solar cells materials were irradiated by electron beams with an energy source of 2MeV at different dose rates of 60 kGy, 120 kGy 240 kGy and 900 kGy and then their photoelectrical parameters were measured at 1 sun $(100 mW/cm^2)$. It was shown that the efficiency of DSSC was decreased as increasing the dose of e-beam irradiation due to lowering in $TiO_2$ crystallinity, decomposition of dye and oxidation of FTO glasses. On the other hand, the performance of solid-state DSSC with polyethylene oxide based electrolyte was improved after irradiation of e-beam due to enhancement of its conductivity and breakage of crosslinking.

  • PDF

Feasibility Study of Gamma Ray Transmission Technique in Distillation Column Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 감마선 투과계측 증류탑 진단기술의 타당성 연구)

  • Moon, Jinho;Kim, Jongbum;Park, Jang Guen;Jung, Sung-Hee
    • Journal of Radiation Industry
    • /
    • v.7 no.2_3
    • /
    • pp.115-119
    • /
    • 2013
  • The density profile measurement technology by gamma transmission has been widely used to diagnose processes in the field of refinery and petrochemical industry. This technology can reveal a clue and position of abnormal phenomenon of industrial processes during their operation. In this paper, the feasibility of the gamma transmission technology for detecting changes in the amount of fluid in a distillation column was evaluated by using Monte Carlo simulations. The simulations assumed that $^{60}Co$ (1.17, 1.33 MeV) sources and NaI (Tl) detectors (${\Phi}5{\times}5cm$) are located in opposite sides of a column and it concurrently moves in vertical direction. To determine the dependency of a spatial resolution on aperture size of a collimator, the simulation model for a tray in a column were simulated with the aperture sizes of 1 and 2 cm. The thickness of the high density area including a tray and fluid was 7.6 cm in the simulation. The spatial resolution of the tray was 8.2 and 8.5 cm, respectively. As a result, it was revealed that the conventional density profile measurement technique is not able to show the deviation of liquid level on a tray in a column.

Comparative analysis of TiO2, Fe2O3, CaO and CuO in borate based glasses for gamma ray shielding

  • Heba Jamal Alasali;U. Rilwan;K.A. Mahmoud;Taha A. Hanafy;M.I. Sayyed
    • Nuclear Engineering and Technology
    • /
    • v.56 no.10
    • /
    • pp.4050-4055
    • /
    • 2024
  • This research intends to utilize melt-quenching technique in order to examine the radiation shielding capability of 10 % Mo, 10 % Na2O, 20 % PbO, and 60 % B2O3 glass system, with varying CaO, TiO2, CuO, Fe2O3 or Mo. XCOM and MCNP simulations were utilized to analyze the radiation shielding properties of the fabricated glasses. The results revealed CuO having the superior MAC of 49.91 cm2/g, then Fe2O3 with 49.24 cm2/g, followed by CaO with 49.10 cm2/g, and TiO2 with 48.49 cm2/g as the least. CuO and Fe2O3 were confirmed to have least HVL compared to CaO and TiO2. The value of the lead equivalent thickness showed fluctuation against the gamma energy, where it raisess within the photoelectric region and falls after the photoelectric region. The data reveal that, the lead equivalent thickness at 0.1 MeV were 7.88 cm, 7.86 cm, 7.81 cm and 7.80 cm for TiO2, Fe2O3, CaO, and CuO in the same order, respectively. The transmission factor (TF) raises as the gamma energy raises, having TiO2 as the highest with 76.068 %, while the radiation protection efficiency dropped as the energy raises.

Mouse model system based on apoptosis induction to crypt cells after exposure to ionizing radiation (방사선에 전신 조사된 마우스 음와 세포의 아포토시스 유도를 이용한 생물학적 선량 측정 모델 개발 연구)

  • Kim, Tae-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.4
    • /
    • pp.571-578
    • /
    • 2001
  • To evaluate if the apoptotic fragment assay could be used to estimate the dose prediction after radiation exposure, we examined apoptotic mouse crypt cells per 1,000 cells after whole body $^{60}Co$ $\gamma$-rays and 50MeV ($p{\rightarrow}Be^+$) cyclotron fast neutron irradiation in the range of 0.25 to 1 Gy, respectively. The incidence of apoptotic cell death rose steeply at very low doses up to 1 Gy, and radiation at all doses tigger rapid changes in crypt cells in stem cell region. These data suggest that apoptosis may play an important role in homeostasis of damaged radiosensitive target organ by removing damaged cells. The curve of dose-effect relationship for the data of apoptotic fragments was obtained by the linear-quadratic model $y=0.18+(9.728{\pm}0.887)D+(-4.727{\pm}1.033)D^2$ ($r^2=0.984$) after $\gamma$-rays irradiation, while $y=0.18+(5.125{\pm}0.601)D+(-2.652{\pm}0.7000)D^2$ ($r^2=0.970$) after neutrons in mice. The dose-response curves were linear-quadratic, and a significant dose-response relationship was found between the frequency of apoptotic cell and dose. These data show a trend towards increase of the numbers of apoptotic crypt cells with increasing dose. Both the time course and the radiation dose-response curve for high and low linear energy transfer (LET) radiation modalities were similar. The relative biological effectiveness (RBE) value for crypt cells was 2.072. In addition, there were significant peaks on apoptosis induction at 4 and 6h after irradiation, and the morpholoigcal findings of the irradiated groups were typical apoptotic fragments in crypt cells that were hardly observed in the control group. Thus, apoptosis in crypt cells could be a useful in vivo model for studying radio-protective drug sensitivity or screening test, microdosimetric indicator and radiation-induced target organ injury. Since the apoptotic fragment assay is simple, rapid and reproducible in the range of 0.25 to 1 Gy, it will also be a good tool for evaluating the dose response of radiation-induced organ damage in vivo and provide a potentially valuable biodosimetry for the early dose prediction after accidental exposure.

  • PDF

Radiation Dose during Transmission Measurement in Whole Body PET/CT Scan (전신 PET/CT 영상 획득 시 투과 스캔에서의 방사선 선량)

  • Son Hye-Kyung;Lee Sang-Hoon;Nam So-Ra;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • The purpose of this study was to evaluate the radiation doses during CT transmission scan by changing tube voltage and tube current, and to estimate the radiation dose during our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan. Radiation doses were evaluated for Philips GEMINI 16 slices PET/CT system. Radiation dose was measured with standard CTDI head and body phantoms in a variety of CT tube voltage and tube current. A pencil ionization chamber with an active length of 100 mm and electrometer were used for radiation dose measurement. The measurement is carried out at the free-in-air, at the center, and at the periphery. The averaged absorbed dose was calculated by the weighted CTDI ($CTDI_w=1/3CTDI_{100,c}+2/3CTDI_{100,p}$) and then equivalent dose were calculated with $CTDI_w$. Specific organ dose was measured with our clinical whole body $^{137}Cs$ transmission scan and high quality CT scan using Alderson phantom and TLDs. The TLDs used for measurements were selected for an accuracy of ${\pm}5%$ and calibrated in 10 MeV X-ray radiation field. The organ or tissue was selected by the recommendations of ICRP 60. The radiation dose during CT scan is affected by the tube voltage and the tube current. The effective dose for $^{137}Cs$ transmission scan and high qualify CT scan are 0.14 mSv and 29.49 mSv, respectively. Radiation dose during transmission scan in the PET/CT system can measure using CTDI phantom with ionization chamber and anthropomorphic phantom with TLDs. further study need to be peformed to find optimal PET/CT acquisition protocols for reducing the patient exposure with same image qualify.

  • PDF

Artificial Control of ZnO Nanorods via Manipulation of ZnO Nanoparticle Seeds (산화아연 나노핵의 조작을 통한 산화아연 나노로드의 제어)

  • Shin, Kyung-Sik;Lee, Sam-Dong;Kim, Sang-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.399-399
    • /
    • 2008
  • Synthesis and characterization of ZnO structure such as nanowires, nanorods, nanotube, nanowall, etc. have been studied to multifunctional application such as optical, nanoscale electronic and chemical devices because it has a room-temperature wide band gap of 3.37eV, large exiton binding energy(60meV) and various properties. Various synthesis methods including chemical vapor deposition (CVD), physical vapor deposition, electrochemical deposition, micro-emulsion, and hydrothermal approach have been reported to fabricate various kinds of ZnO nanostructures. But some of these synthesis methods are expensive and difficult of mass production. Wet chemical method has several advantage such as simple process, mass production, low temperature process, and low cost. In the present work, ZnO nanorods are deposited on ITO/glass substrate by simple wet chemical method. The process is perfomed by two steps. One-step is deposition of ZnO seeds and two-step is growth of ZnO nanorods on substrates. In order to form ZnO seeds on substrates, mixture solution of Zn acetate and Methanol was prepared.(one-step) Seed layers were deposited for control of morpholgy of ZnO seed layers by spin coating process because ZnO seeds is deposited uniformly by centrifugal force of spin coating. The seed-deposited samples were pre-annealed for 30min at $180^{\circ}C$ to enhance adhesion and crystallinnity of ZnO seed layer on substrate. Vertically well-aligned ZnO nanorods were grown by the "dipping-and-holding" process of the substrates into the mixture solution consisting of the mixture solution of DI water, Zinc nitrate and hexamethylenetetramine for 4 hours at $90^{\circ}C$.(two-step) It was found that density and morphology of ZnO nanorods were controlled by manipulation of ZnO seeds through rpm of spin coating. The morphology, crystallinity, optical properties of the grown ZnO nanostructures were carried out by field-emission scanning electron microscopy, high-resolution electron microscopy, photoluminescence, respectively. We are convinced that this method is complementing problems of main techniques of existing reports.

  • PDF

Temperature dependency of the ZnO nanostructures grown by metalorganic chemical vapor deposition (MOCVD법으로 성장한 ZnO 나노구조의 온도 의존성)

  • Choi, Mi-Kyung;Kim, Dong-Chan;Kong, Bo-Hyun;Kim, Young-Yi;Ahn, Chel-Hyun;Han, Won-Suk;Mohanta, Sanjay Kumar;Cho, Hyung-Koun;Lee, Ju-Young;Lee, Jong-Hoon;Kim, Hong-Seung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.20-20
    • /
    • 2008
  • 최근 LEDs가 동일 효율의 전구에 비해 에너지 절감 효과 크며 신뢰성이 뛰어나다기 때문에 기존 광원을 빠르게 대체해 나가고 있다. 특히 자외선 파장을 가지는 LEDs는 발열이 낮아 냉각장치가 필요 없으며, 수명이 길어 기존 UV lamp에 비해 많은 장점을 가지고 있기 때문에 많은 관심을 밭고 있다. 그럼에도 불구하고 자외선 LEDs는 제조 단가가 높고 power가 낮아 소요량이 많은 등 아직 해결해야 할 부분이 많기 때문에 이를 해결하기 위해 여러가지 재료와 다양한 구조가 고려되고 있다. 그 중 ZnO는 II-VI족 화합물 반도체로써 UV영역의 넓은 밴드갭(3.37eV)을 가지는 투명한 재료이다. 특히 ZnO는 60meV의 큰 엑시톤 결합에너지를 가지며, 가시광 영역에서 높은 투과율을 가지고, 상온에서 물리적, 화학적으로 안정하기 때문에 UV sensor, UV laser, UV converter, UV LEDs 등 광소자 분야에서 연구가 활발히 진행되고 있다. ZnO가 광소자의 발광재료로써 높은 효율을 얻기 위해서는 결정성을 높여 내부 결함을 감소시키며, 발광 면적을 높일 수 있는 구조가 요구된다. 특히 MOCVD 법으로 성장한 나노막대는 에피성장되어 높은 결정성을 기대할 수 있으며, 성장 조건을 조절함으로써 나노막대의 aspect ratio와 밀도 제어할 수 있기 때문에 표면적을 효과적으로 넓혀 높은 발광효율을 얻을 수 있다. 본 실험에서는 MOCVD 법으로 실리콘과 사파이어 기판 위에 다양한 성장 온도를 가진 나노구조를 성장 시키고 온도에 따른 형상 변화와 특성을 평가하였다. ZnO 의 성장온도가 약 $360^{\circ}C$ 일 때, 밀도가 조밀하고 기판에 수직 배열한 균일한 나노막대가 성장되었으며 우수한 결정성, 광학적 특성이 나타남을 SEM, TEM, PL, XRD를 사용하여 확인하였다.

  • PDF