• 제목/요약/키워드: 60 Hz

검색결과 1,303건 처리시간 0.027초

CCM용융에 대한 유리용융 조건 연구 (The Study on the Power Consumption for Glass Melting by Cold Crucible Melter)

  • 진현주;이규호;장영재;배소영;김태호;정영준;김영석;이강택;류봉기
    • 대한금속재료학회지
    • /
    • 제46권2호
    • /
    • pp.65-68
    • /
    • 2008
  • Generally CCM (cold crucible melting) is not suitable for melting glass. However, in this study we described the quantitative relationship between the basic property of glass and power balance, the power absorption in the melt, the losses in the coil and the cold crucible, for melting glass in CCM. The dependence of power balance on the applied frequency and the electric conductivity has been found. Above 300 kHz, the glass (B) contained alkali ion which has the low resistance $3.0{\Omega}{\cdot}cm$ at $900^{\circ}C$ and $1.36{\Omega}{\cdot}cm$ at $1,100^{\circ}C$ was melted easily and 60% of the overall power was absorbed in the melt and 30% and 10% of the overall power was lost in the cold crucible and coil respectively. Under the same condition, the glass (A) contained non-alkali ion was not melted easily and 50% of the overall power was absorbed in the melt and 40% and 10% of the overall power was lost in the cold crucible and coil respectively. In conclusion, the small absorbed power of the overall power in melt prevented a successful melting as for glass A, and the successful melting depends on the relative size of the absorbed power in melt irrespective of the melting volume. Hence, as typical for direct induction heating method(CCM), the successful melting strongly depended on the chosen working frequency based on electric conductivity of glass, power balance and the control of the critical power which was absorbed in melt.

한국우주전파관측망(KVN)의 영상모의실험 (IMAGING SIMULATIONS FOR THE KOREAN VLBI NETWORK(KVN))

  • 정태현;이명현;노덕규;김현구;손봉원
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권1호
    • /
    • pp.1-12
    • /
    • 2005
  • 한국우주전파관측망(Korean VLBI Network: KVN)은 우리나라 최초의 초장기선 전파간섭계로 새로운 천문우주 연구 분야 및 측지, 지구물리 등의 연구를 위하여 3기의 21m 최첨단 밀리미터파 전파 안테나를 이용하여 우주를 바라보는 새로운 영역을 개척할 예정이다. 전파간섭계의 성능은 안테나 배열 및 관측 대상 천체의 적위, 그리고 천체와 크기 및 형태에 따른 의존성이 매우 크다. 본 연구는 현재 설정되어있는 KVN관측소 및 시스템 자료를 근거로 단일 점광원, 다중 점광원, 원형광원 2개, Cygnus A의 5개 모델 영상에 대하여 가상관측을 수행하였다. 적위에 따른 KVN의 UV 궤적 분포로부터 가장 이상적이라고 여겨지는 적위 60도인 천체에 대하여 22GHz의 관측 파장으로 12시간 동안 가상관측을 수행하여 얻어진 UV데이터를 가지고 간섭계 표준 영상처리를 하였다. 그 결과 22GHz에서 예상되는 KVN의 빔 크기에 의해 분해가 되지 않는 모델들의 RMS 대비 최대밝기 강도(Jy/Beam)가 대략 점광원의 징우 l0000:1, 지름 6mas(milli arcsecond) 원형 광원의 경우 5000:1 정도로 매우 높은 반면, 빔 크기보다 큰 모델에서는 115:1 및 34:1정도로 현저하게 감소하였으며 영상의 복원 정도도 이와 같은 결과를 보였다. 이것은 KVN이 상대적으로 적은 기선의 개수로 인하여 UV평면을 충분히 채우지 못하며, 동시에 짧은 기선이 부족하여 넓은 분포를 가지는 천체들에 대한 영상화능력이 떨어지기 때문이다. 그러나 각 모델과 CLEAN 영상과의 픽셀 좌표비교에서는 12mas 원형광원을 제외하고는 정확하게 일치함을 보였다. 그러므로 KVN의 주요한 관측 대상은 콤팩트한 천체들이 적당할 것이며, 이러한 천체들에 대하여 KVN은 위치측정에 우수한 성능을 보였다.

도시하수슬러지의 전처리에 따른 혐기성 소화공정의 생분해율 향상에 관한 연구 (The study on increasing of biodegradability by pre-treatment of municipal wasted sludge in anaerobic digestion process)

  • 강창민
    • 유기물자원화
    • /
    • 제10권1호
    • /
    • pp.87-95
    • /
    • 2002
  • 슬러지의 용해율 증가 및 생분해율 향상을 위해 전처리 방법별 처리조건 및 회분, 연속실험을 실시하였다. 용해효과실험에서 SCOD 기준 용해율 효과는 온도무고정 초음파처리(35분)가 가장 높고, 다음으로 알칼리처리(pH13), 열처리($200^{\circ}C$, 30min), 온도고정 초음파처리(60분)순서였다. 초기 회분실험에서 적정 혼합비율은 가스생성량을 기준하여 종오니 : 기질비가 4 : 6일 때(유기물 부하량$3.48kg/m^3{\cdot}day$) 가장 효과적이었다. 회분실험에서 가스발생량은 열처리($200^{\circ}C$, 30min)가 가장 높고, 다음으로 초음파처리(온도 무조정), 알칼리처리(pH9), 초음파처리(온도조정)순서였다. 연속실험은 회분실험에서 가장 효과적인 열처리($200^{\circ}C$, 30min) 시료를 이용하였다. pH는 열처리 (pH 7.2~7.3)가 무처리 (pH 6.9~7.0)시료에 비해 다소 높은 값을 나타내었다. HRT가 길수록 유출수의 pH가 상승하는 경향을 나타내고 있고, 이는 유기물부하의 감소에 따른 생성유기산의 농도저하와 유기산의 가스로의 전환에 의해 생성된 $N_2$가스의 완충작용에 기인한다고 생각된다. 반응조내의 SCOD 농도는 전처리 시료가 무처리에 비해 약 2.5배 높고, 또 HRT는 짧을수록 높았다. 용해성 단백질 및 탄수화물 농도도 전처리 시료가 무처리 시료에 비해 각각 2배 및 3.3배 높았다. 가스 생성량은 열처리시료가 무처리 시료에 비해 약 2배 높아, 열처리가 소화효율 향상에 효과적임을 알 수 있었다. 가스 생성량은 HRT 7day일 때 가장 유리했다. 그러나 HRT 2.5day 일 때 가스 생성량은 무처리 시료에 비해서도 낮은 값을 나타내어 혐기성 세균이 고농도로 축적된 유기산의 저해를 받았기 때문이라고 생각된다.

  • PDF

추출 공정별 매자나무 추출물의 항암활성 비교 (Comparison of Anticancer Activities of Berberis koreana Extracts Obtained by Different Extraction Processes)

  • 하지혜;권민철;서용창;최운용;정을권;정애란;김진철;안주희;이현용
    • 한국식품과학회지
    • /
    • 제42권2호
    • /
    • pp.233-239
    • /
    • 2010
  • 본 연구에서는 초고압 및 초음파 공정을 병행하여 실시하는 추출공정을 이용하여 매자나무 수피의 면역활성 및 Sarcoma-180에 의해 유발되는 복수암 및 고형암에 대한 항암활성 증진 효과를 평가하였다. 상기 추출 공정을 통해 매자나무 추출물의 수율이 일반 열수 추출에 비해 1.7배 증가하였으며, 정상세포에 대한 생존율을 80%이상 유지하는 것으로 나타나 독성 저감 효과도 갖는 것으로 확인되었다. 특히, 매자나무의 초고압, 초음파 병행 추출물이 소화기계 암세포주인 AGS와 Caco-2에 대해서 약 70%의 암세포 생육 저해활성을 나타내며, 최고 4 이상의 selectivity를 나타내며 선택적인 암세포 사멸 효과를 나타내었다. 기존의 연구에서 항암성 면역증강제로 사용되고 있는 버섯의 단백 다당체와 관련하여 영지버섯이 효과적인 항암 활성을 나타내며, 특히 위암 세포인 AGS에 대해 50 mg/mL의 고농도의 영지버섯 추출물이 76% 이상의 암세포 생육저해 활성을 나타내었다(24). 이러한 연구 결과와 비교할 때 본 연구의 매자나무 추출물이 갖는 소화기계 암세포 생육저해 활성은 매우 높다고 할 수 있다. 또한 항암성 면역 활성 측정 결과 초고압, 초음파 병행 추출물이 일반 열수 추출 공정이나 초음파, 초고압 단독 추출 공정을 통한 추출물에 비해 nitric oxide 및 IgG의 생성을 증가시키는 것을 확인할 수 있었다. 초고압 및 초음파 추출 공정이 약용작물의 활성성분 용출에 기여하며, 특히 저온 초고압 추출 공정이 매자나무의 주요 활성성분인 berberine의 용출을 증가시킨다는 연구 결과(25,26)에 미루어 볼 때 초고압, 초음파 병행 추출 공정이 매자나무 활성 성분 용출에 효과적인 영향을 미치는 것으로 사료된다. In vivo 실험을 통한 추출 공정별 매자나무 추출물의 항암 활성 평가를 통해서 상기 공정을 통한 매자나무 추출물이 40% 이상의 복수암 유발 마우스의 수명율 연장과 약 75%의 고형암 억제 활성을 나타내며 효과적인 항암활성을 확인할 수 있어, 향후 항암성 면역증강제 및 기능성 항암제로서의 기능성 소재화로서의 활용성이 매우 높을 것으로 사료된다.

결장뉴 전기활동도에 대한 Ouabain과 Vanadate의 작용 (Effects of Ouabain and Vanadate on the Spontaneous Contractions and Electrical Activity in Guinea-pig Taenia Coli)

  • 박종규;김기환;서인석
    • The Korean Journal of Physiology
    • /
    • 제22권2호
    • /
    • pp.189-206
    • /
    • 1988
  • The effects of ouabain on the contractile and electrical activities were investigated in the isolated preparations of guinea-pig taenia coli, and compared with those of vanadate. Spontaneous contractions were recorded with force transducer, and electrical activites were measured by use of suction electrode, or single sucrose-gap technique. The contractions were induced by the electrical stimulation for 5 seconds every 1 minute with alternating current (60 Hz, 3.0 V/cm) through the platinum electrodes located in parallel with the long axis of the preparation. All experiments were performed in tris-buffered Tyrode solution which was aerated with $100%{\;}O_2$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) Responses of spontaneous contractions to ouabain were concentration-dependent; $10^{-7}M$ ouabain caused a rise of basal tone. Above the concentration of $10^{-6}M$ ouabain, an initial increase followed by a decrease in tension was observed. 2) A continuous spike discharge was induced by the administration of $10^{-7}M$ ouabain. Above $10^{-6}M$ ouabain, a transient initial increase followed by a decrease in spike frequency and amplitude was produced, and finally membrane potential was sustained at a certain level without a spike discharge. 3) The characteristic response to $10^{-7}M$ ouabain was not blocked by the pretreatment with $10^{-7}M$ atropine. 4) The electrically induced contractions were completely suppressed at the concentration of $2{\times}10^{-7}M$ ouabain. These contractions were blocked more rapidly in paralled with the increase in ouabain concentration. 5) Effects of vanadate on the spontaneous activities were quite different from those of ouabain; $10^{-6}M$ vanadate increased the amplitude of contractions and $10^{-5}M$ vanadate increased slightly both amplitude and frequency of spontaneous contractions. $10^{-4}M$ vanadate showed irregular phasic contractions superimposed on the increased basal tone. 6) $10^{-5}M$ vanadate depolarized the membrane potential and shortened the interval between the bursts of spike discharge, whereas $10^{-4}M$ vanadate induced continuous spike discharge with membrane depolarization. 7) Vanadate caused a characteristic inhibitory response to the contractions induced by electrical stimulation; An initial rapid inhibition of tension development and then gradual recovery to a certain level. From the above results, the following conclusions could be made: 1) The rise of basal tone at $10^{-7}M$ ouabain is due to continuous spike discharge without a silent period. The continuous spike discharge is likely to be associated with a slight membrane depolarization caused by the blockage of Na pump. 2) The biphasic response induced by above $10^{-6}M$ ouabain seems to occur by the different mechanisms. The initial increase in tension is associated with depolarization along with an increase in spike frquency, whereas the subsequent relaxation occurs through a non-electrical mechanism. 3) The characteristic response to $10^{-7}M$ ouabain is resulted not from the action on intrinsic nerve terminal, but from its direct action on the membrane of smooth muscle cells. 4) The phasic contractions superimposed on the increased basal tone at the concentration of $10^{-4}M$ vanadate is resulted from the continuous spike discharge with membrane depolarization, of which mechanism remains unknown. 5) The inhibitory action of ouabain on the electrically induced contractions suggests that the increasein intracellular Na in some way inhibits the electrically induced $Ca^{2+}$ influx. The mechanism of vanadate action on the induced contractions remains unknown.

  • PDF

국내 전철 및 가전제품을 대상으로 한 전자장 수준 실태조사 (A survey on the EMF Levels of Study and Electric Appliances in Korea)

  • 장성기;조용성;이석조;유승화;정경미;임준호
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.71-81
    • /
    • 2005
  • The purposes of this study was to collect, analyze, and describe the MF exposure levels from subways in Korea and to measure and evaluate the MF levels generated from electric appliances used at general homes. The target subway lines were Seoul Metropolitan Line 1 to Line 8, Bundang Line, Incheon Line, Daegu Line, Gwangju Line, and Busan Line 1 and Line 2. We measured at each station in those subway lines and, all the train types (pantograph-equipped, motor-equipped, and common), and platform types(facing and isolating) were investigated by the distance(80, 200, 400 cm) from the train on 19 targeted subway lines using 3 magnetic field measuring devices (EMDEXII, Enertech Co.) during the survey from January till October, 2004. On the other hand, the levels of the 60Hz magnetic fields generated from 14 items of home electric appliances such as electric blankets, hair dryers, electric razors, etc. were measured at 10 general homes using 5 EMDEXII meters with a sampling interval of 1.5 second by the distance(surface, 30, 50, 100, 300cm ) from the target electric appliances. The survey results in the whole subway lines examined in this study were as follows; Seoul Metropolitan Line 4 using AC(alternating current) power source showed the highest mean value of $2.85{\mu}T$, followed by Seoul Metropolitan Line 1 running between Seoul and Incheon using AC($2.78{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Uijongbu using AC($2.73{\mu}T$), Bundang Line using AC($1.79{\mu}T$), Seoul Metropolitan Line 1 connected from Yongsan using AC($1.67{\mu}T$), Seoul Metropolitan Line 1 between Seoul and Suwon using AC($0.79{\mu}T$), and so on. In general, the intensity of the magnetic field in the subway systems in Korea was significantly higher when using AC($2.14{\pm}0.91{\mu}T$) than when using DC($0.29{\pm}0.44{\mu}T$) power source. Among the home electric appliances examined, microwave ovens showed the highest mean value of $7.69{\mu}T$, followed by hair dryers($6.47{\mu}T$), vacuum cleaners($5.27{\mu}T$), televisions ($2.26{\mu}T$), electric blankets($1.38{\mu}T$), personal computers ($0.81{\mu}T$), and so on. Two items of electric appliances showed the excess value of $0.2{\mu}T$ at the distance of 30cm in the MF exposure level; electric razors $1.58{\pm}2.13{\mu}T$ and vacuum cleaners $0.48{\pm}0.44{\mu}T$. As a whole, this study showed a tendency that the shift of the MF levels according to the increase of distance from the electric appliances was lower than those of the results surveyed in UK and USA. As a result, this study is expected to suggest meaningful data for the future study in exposure assessment of magnetic fields and for the establishment of guidelines for subways and electric appliances in Korea. More detailed and large scaled exposure assessment studies should be performed continuously to get the various and useful information on health risk assessment of MFs in Korea.

플라즈마 전해 산화법에 의해 용융알루미늄도금 강판 상 형성한 산화층과 그 성장 과정 (Oxide Films Formed on Hot-Dip Aluminized Steel by Plasma Electrolytic Oxidation and Their Films Growth Stages)

  • 최인혜;김창민;박준무;박재혁;황성화;이명훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.165-165
    • /
    • 2017
  • 지난 수 십 년 동안, 전 세계적으로 자원의 소비가 급격히 증가하게 되면서 최근 자원 고갈은 물론 환경오염이 커다란 이슈로 문제가 되고 있다. 이에 따라 재료 관련 분야에 있어서는 보다 효율적이고 친환경적인 방법으로 자원을 활용해야 된다는 필요성이 대두되었고 이와 같은 관점에서 목적하는 성분이 우수하고 환경 친화적인 표면처리 재료 개발연구가 활발하게 진행되고 있는 실정이다. 그 중 플라즈마 전해 산화(Plasma Electrolytic Oxidation, PEO)는 알루미늄, 마그네슘 등의 경금속의 경도를 향상시키고 높은 내마모성, 내식성을 갖게 하는 표면처리로써 그 관심이 증가하고 있다. 이 플라즈마 전해 산화는 일반적으로 공정비용 대비 효과적이고 환경 친화적이며 코팅 성능 면에서 우수하다고 알려져 있다. 이러한 고유한 특성으로 인해 플라즈마 전해 산화 코팅은 최근 몇 년 동안 기계, 자동차, 우주항공, 의학 및 전기 산업 등의 분야에서 그 적용이 점차 증가하고 있는 상황이다. 한편, 플라즈마 전해 산화 코팅을 하는 모재들의 경우 부동태 산화피막을 용이하게 형성할 수 있는 특성의 모재에 한정되고 있어서 그 응용확대에 한계가 있는 것이 사실이다. 따라서 본 연구에서는 플라즈마 전해 산화법을 사용하여 용융알루미늄도금 강판 상에 산화피막 형성을 시도하였다. 전원공급 장치의 양극은 전해질 속에 잠겨있는 작동전극에 연결하고 음극은 대전극 역할을 하는 스테인레스강 전해질 용기에 연결되었다. 전해질은 Sodium Aluminate 및 기타 첨가제를 함유한 것을 사용하였고 온도는 열교환기를 사용하여 $30^{\circ}C$ 이하로 유지되었다. 또한 여기서 전류밀도는 $5{\sim}10A/dm^2$, 실험 주파수는 700Hz, Duty cycle은 30 및 90%의 각 조건에서 공정처리 시간을 각각 30분 및 60분 동안 진행하였다. 이와 같은 조건에서 형성한 막들에 대해서는 주사형전자현미경(SEM)을 이용하여 코팅 막의 표면 및 단면의 모폴로지를 관찰하였음은 물론 EDS 및 XRD 측정을 통하여 원소조성분포 및 결정구조를 각각 분석하였다. 또한 이 코팅 막들에 대한 내식성은 5% 염수분무 환경 중 노출시험(Salt spray test), 3% NaCl 용액에서의 침지 시험 및 전기화학적 동전위 양극분극(Potentiodynamic Polarization) 시험을 진행하여 평가하였다. 이상의 실험결과에 의하면, 제작조건별 플라즈마 전해 산화 코팅 막의 모폴로지 및 결정구조가 상이하게 나타나는 것을 알 수 있었다. 코팅 막의 모폴로지 관찰 결과, 공정 시간에 비례하여 표면에 존재하는 원형 기공의 수는 감소하였으나 그 크기가 커지고 크레이터의 직경 또한 커진 것이 확인되었다. 이 기공은 마이크로 방전에 의해 형성된다고 알려져 있는데 공정 시간이 증가함에 따라 코팅 두께가 점차 증가하여 마이크로 방전의 빈도수가 줄어들고 그 강도는 증가하게 되어 기공 크기가 증가한 것으로 사료된다. 또한 공정시간이 긴 시편에서 표면에 크랙이 다수 존재하는 것으로 확인되었다. 이것은 방전에 의해 고온이 된 소재가 차가운 전해질과 만나게 되어 생긴 큰 온도구배로 인해 강한 열응력이 발생하여 균열을 초래한 것으로 보인다. 조성원소 분석 결과 원형 기공 주변의 크레이터 영역에는 알루미늄이 풍부하였으며 그 주변에 결절상을 갖는 구조에서는 전해질 성분의 원소가 포함되어 있는 것이 확인되었다. 이러한 코팅 막의 표면 특성은 내식성에 영향을 주게 된 원인으로 사료된다. 동전위 분극측정 결과에 의하면 플라즈마 전해 산화 공정 시간이 길어질수록 부식전류밀도가 증가하였다. 이것은 공정시간이 길어짐에 따라 강한 방전이 발생하여 기공의 크기가 증가하고 크랙이 발생하게 되면서 내식성이 저하된 것으로 판단된다. 종합적으로 재료특성 분석 및 내식성 평가를 분석한 결과, 플라즈마 전해 산화의 공정 시간이 너무 길게 되면 오히려 내식성은 저하되는 것이 확인되었다. 이상의 연구를 통하여 고내식 특성을 갖는 플라즈마 전해 산화 막의 유효성을 확인하였으며 용융알루미늄강판 상에 실시한 플라즈마 전해 산화 처리에 대한 기초적인 응용 지침을 제시할 수 있을 것으로 사료된다.

  • PDF

평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험- (A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

자기장 저속 냉동보관법을 이용한 쥐 치아 치주인대세포의 활성도 검사 (EVALUATION OF THE VIABILITY OF PERIODONTAL LIGAMENT CELL IN RAT TEETH USING SLOW CRYOPRESERVATION METHOD WITH MAGNETIC FIELD)

  • 안현정;김의성;김진;김덕원;김기열;이찬영;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제33권4호
    • /
    • pp.332-340
    • /
    • 2008
  • 본 연구의 목적은 흰쥐 상악 대구치를 발거하여 자기장 저속 냉동보관법을 이용하여 냉동 시 치주인대세포의 환성도 및 세포 사멸도를 MTT 검색법과 TUNEL 검사를 이용하여 측정하고자 하였다. 4주령의 암컷 Sprague-Dawley계 흰쥐의 상악 좌우 제1,2대 구치를 발거하여 각 군 당 12개의 쥐 치아를 MTT검색에 이용하였고 6개의 치아를 TUNEL 검사에 이용하였다. 실험군은 5개군으로 대조군은 즉시 발치군이며 4$^{\circ}C$ 냉장고에서 1주일간 보관한 냉장군, 발치 후 동해방지제 처리과정을 거쳐 -196$^{\circ}C$의 액화질소에 넣어 급속 냉동한 액화질소군, 217 mA, 60 Hz, 1 G의 자기장을 이용하여 -0.3$^{\circ}C$/min 의 속도로 -20$^{\circ}C$까지 냉동 후 -196$^{\circ}C$로 급속 냉동한 자기장군, -0.3$^{\circ}C$/min의 속도로 -20$^{\circ}C$까지 냉동 후 -196$^{\circ}C$에 급속 냉동한 저속 냉동군으로 나누었다. 보존액은 F medium을 사용했으며 동해방지제로 10% dimethyl sulfoxide (DMSO)를 사용하였다. 치근면을 단위면적으로 표준화하기 위해 MTT 측정값을 Eosin 염색 후 530 nm에서 측정 한 흡광도 값으로 나누었다. TUNEL 검사 시 각 조직슬라이드에서 400배 크기의 현미경 시야에서 임의로 세 부분을 지정하여 정상 세포수와 양성 세포수를 세어 그 비율을 계산하여 각 실험군 당 평균치를 구하였다. 통계 분석을 위해 one way ANOVA를 시행하였으며 사후검정으로 Scheffe와 Tukey HSD방법을 썼으며 결과는 다음과 같다. MTT검색에 의한 흡광도를 Eosin염색 후 측정한 흡광도로 나눈 값에서는 자기장군은 즉시 발치군보다 낮은 세포활성을 보였고 (p < 0.05) 액화질소군, 저속 냉동군과는 통계적으로 유의성 있는 차이를 보이지 않았다. 그러나 자기장군은 액화질소군, 저속 냉동군과 함께 냉장군보다는 높은 세포 활성도를 보였다 (p < 0.05) TUNEL 검사 결과도 자기장군은 즉시 발치군보다 치주인대의 세포사멸도가 높았으나 (p < 0.05) 저속 냉동군과 액화 질소군과는 통계적으로 유의한 차이를 보이지 않았다. 자기장군은 냉장군보다 세포사멸도가 낮았으며 냉장군은 모든 군 중에서 세포 사멸도가 가장 높았다 (p < 0.05).

식품분말 진동선별기 개선을 위한 구조물 효율 분석 (Efficiency Analysis of Spiral Structured Twist Screen)

  • 박인순;나은수;장동순;백영수
    • 산업식품공학
    • /
    • 제14권2호
    • /
    • pp.85-91
    • /
    • 2010
  • 식품 산업 가공 공정에 다양하게 적용되는 진동 선별기(twist screen)의 구조를 변경하고 그 효율을 분석하기 위하여 위와 같은 실험을 실시하였다. 시료 공급 시 스크린 외곽의 프레임을 따라 선별되지 못하고 빠지는 입자를 방지하기 위하여 스크린 프레임에 dam을 설치하였으며, 스크린 중앙에서 공급되는 시료가 진동에 의하여 중앙에서 외곽으로 빠르게 이동하며 입자층을 이루어 선별 효율이 저하되는 것을 방지하기 위하여 스크린에 나선형 구조물을 설치하였다. 진동 선별기는 직경 1,200 mm와 직경 1,500 mm를 사용하였으며 스크린은 mesh 24이고 선경 0.12 mm인 표준망을 적용하였고 진동 모터는 60 Hz로 운전하였으며 자기진동 이송기는 주파수 게이지 8과 10으로 각각 실험한 결과 다음과 같은 결론을 도출하였다. 진동 선별기 직경 1,200 mm인 경우 일반형은 처리 용량 24 kg/hr, 처리 분율은 4.72%이었고 스크린 프레임에 dam을 설치하고 스크린에 나선형 구조물을 설치한 경우에는 처리 용량이 22.8 kg/hr, 처리 분율 8.05%이었다. 구조물의 설치로 처리 용량은 다소 감소하였으나 처리 분율은 1.7배 증가하여 선별 효율이 상당히 높아졌다는 것을 알 수 있었다. 진동 선별기 직경 1,500 mm의 경우 일반형의 처리 용량은 43.32 kg/hr으로 직경 1,200 mm인 경우와 비교하여 처리용량은 1.8배 증가하였으나 처리 분율은 2.37%로 처리용량에 비하여 낮게 나타났다. 처리 1의 입도를 분석한 결과 스크린에 의하여 선별될 세립의 입자가 비선별 처리물에서 발견되고 있다. 스크린의 직경이 넓어져서 처리 용량이 증가하였으나 공급 속도를 높여 공급량이 많아지므로 입자들의 망 접촉 시간이 감소하고 입자의 층 현상이 심화되어 처리 효율이 감소하고 세립의 입자 선별이 완벽하게 이루어지지 않았다는 것을 알 수 있었다. 선별기 직경 1,500 mm에 screen frame dam을 설치한 경우 처리 용량 43.14 kg/hr로 일반형과 비슷하며 처리 분율은 3.25%로 매우 증가되었다. 입자들의 층현상이 심화된 ${\emptyset}$1500에서 스크린의 프레임에 dam을 설치함으로써 스크린 프레임으로 빠져나가 망에 체류 시간이 단축되는 것이 방지되며 프레임을 따라 입자층이 형성되어 스크린과 접촉이 불가능하였던 입자들이 dam에 의하여 스크린 안쪽에서 이동되므로 거의 동일한 처리 용량에서도 처리 효율 증가가 뚜렷하게 구분되었다고 할 수 있다. Screen frame dam과 나선형 구조물을 모두 설치한 경우 처리 용량은 39.04 kg/hr로 다소 감소되었으나 처리 분율은 6.77%로 직경 1,500 mm의 진동 스크린에서 일반형 구조시 보다 3배, frame dam만 설치된 경우보다 2배의 증가를 보였다. 비선별 처리물인 처리 1의 시료를 입도분석한 결과 선별 처리되지 못한 세립의 입자를 전혀 발견할 수 없었다. 이와 같은 결과는 frame dam을 설치하여도 입자들이 빠르게 휩쓸려 스크린의 외곽으로 이동하여 망과 접촉 시간이 단축되며 층을 이루어 입자간의 간섭에 의해 선별 효과가 감소되는 것을 나선형 구조물에 의하여 방지함으로써 체류시간을 증가시키고 입자층을 분산시켜 선별 효율을 증가시킬 수 있었다. 나선형 구조물 설치시 처리 용량은 다소 감소되는 경향을 보이나 처리 분율이 3배까지 차이를 나타나며 이는 공급 속도가 빠를수록 처리 용량이 많을수록 영향이 크다는 것을 알 수 있었다.