• 제목/요약/키워드: 6 pulse

검색결과 2,146건 처리시간 0.028초

맥진기를 이용한 새로운 부침맥 판단 방법 (New Algorithm of Determining the Floating and Sinking Pulse with a Pulse Diagnosis Instrument)

  • 김성훈;김재욱;이유정;김근호;김종열
    • 동의생리병리학회지
    • /
    • 제23권6호
    • /
    • pp.1221-1225
    • /
    • 2009
  • The pulse diagnosis is an important and universally used method in Oriental Medicine. Since the traditional method of palpating the pulse relies on the subjective sense in the fingers of an Oriental Medical Doctor(OMD), there has been continued need for more objective method for pulse diagnosis. Recently, various pulse analyzers have been developed to meet such objective palpation and interpretation. However, most of these attempts were not successful to replace OMD's own palpation by fingers. To improve the performance of the pulse analyzers, one should develop machine-appropriate interpretations for the pulse images in the literature, in addition to the improvement in the repeatability and reproducibility. One of such widely-used pulse images to be interpreted is the floating and sinking pulse. The floating and sinking pulses are the two representative pulse images informing us how strong pressure one should apply to obtain the maximal pulse strength. A previous study suggested a convenient and unified measure for the floating and sinking pulses by defining the coefficient of the floating-sinking pulse(CFS). We found the original definition of the CFS could be erroneous under some situations. To improve the performance, we introduce new CFS algorithm for determining the floating and sinking pulse with a pulse analyzers(3-D MAC). To test the performance of the newly suggested algorithm, we conducted a clinical study comparing the agreement ratio with the floating and sinking pulse diagnosis by the OMDs. We found that, among the subjects who are diagnosed with having either the floating pulse or sinking pulse, the new CFS algorithm showed 55.3% diagnosis rate and 73.0% concordance rate, which are about 3% and 6% improvement in the diagnosis rate and agreement rate, respectively, compared to the original CFS algorithm.

초고속 Marx Generator의 N2, SF6, N2-SF6 혼합가스에 따른 출력 특성 연구 (Ultra fast Marx Generator of N2, SF6, N2-SF6 Mixture Gas based on Research Output Characteristics)

  • 두진석;한승문;허창수;최진수
    • 전기학회논문지
    • /
    • 제59권10호
    • /
    • pp.1850-1855
    • /
    • 2010
  • The application field of the pulse power is very wide. Recently, Pulse power technologies take a large place in several applications. Then, many civil and military applications proceed. Marx generator is widely used in high voltage applications. Marx generator is widely used in high voltage applications, such as eletromagnetic wave and power lasers. This paper, we described about the high voltage pulse generator. A compact size high voltage pulse generator with nanosecnd rise time has been fabricated and investigated experimentally. The marx generator has 2 stages. Each stage was constructed one charging capacitor, two electrodes and one charging resistor. A inductance structure is used in order to improve the switching performances fo the whole generator. The experiments of rise time in pure gas and mixtures of gases were described. We tested the Marx generator at different insulation gas. the results show that the dielectric strength of the $N_2-SF_6$ mixture was significantly increased compared with pure nitrogen gas. The experimental results show that the rise time characteristics of the Marx generator can be controlled through varying insulation gas.

펄스 반복률에 의한 반도체 소자의 오동작 모드와 고장률에 관한 연구 (A Study on Malfunction Mode and Failure Rate Properties of Semiconductor by Impact of Pulse Repetition Rate)

  • 박기훈;방정주;김륙완;허창수
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.360-364
    • /
    • 2015
  • Electronic systems based on solid state devices have changed to be more complicated and miniaturized as the electronic systems developed. If the electronic systems are exposed to HPEM (high power electromagnetics), the systems will be destroyed by the coupling effects of electromagnetic waves. Because the HPEM has fast rise time and high voltage of the pulse, the semiconductors are vulnerable to external stress factor such as the coupled electromagnetic pulse. Therefore, we will discuss about malfunction behavior and DFR (destruction failure rate) of the semiconductor caused by amplitude and repetition rate of the pulse. For this experiment, the pulses were injected into the pins of general purpose IC due to the fact that pulse injection test enables the phenomenon after the HPEM is coupled to power cables. These pulses were produced by pulse generator and their characteristics are 2.1 [ns] of pulse width, 1.1 [ns] of pulse rise time and 30, 60, 120 [Hz] of pulse repetition rate. The injected pulses have changed frequency, period and duty ratio of output generated by Timer IC. Also, as the pulse repetition rate increases the breakdown threshold point of the timer IC was reduced.

맥상용어목록을 이용한 맥상표현 자동추출방법 연구 -『의종손익』을 중심으로- (A Research on Automatic Data Extract Method of Pulse Descriptions Using the List of Pulse Terminology - Based on 『Euijongsonik』 -)

  • 금유정;이병욱;엄동명;송지청
    • 대한한의학원전학회지
    • /
    • 제33권4호
    • /
    • pp.21-32
    • /
    • 2020
  • Objectives : Pulse descriptions in Korean Medical texts are comprised of combinations of pulse terminology, where various combinations of pulse terminology are used to describe disease symptoms. For Korean Medical doctors and professionals, however, it is impossible to identify the entirety of pulse description combinations, and their understanding is mostly limited to those learned from classical texts studied individually. Methods :This research was carried out by using Access of Microsoft Office 365 in Windows 10 of Microsoft. Pulse descriptions were extracted from the text, 『Euijongsonik』. In the final stages, the automatically extracted list of pulse descriptions was refined through [excluded terminology of pulse description]. Results : The PC environment of this research was Intel Core i7-1065G7 CPU 1.30GHz, with 8GB of RAM and a Windows 10 64bit operation system. Out of 6,115 verses 6,497 descriptions were primarily extracted, and after a refinement process, the final list contained 5,507 pulse descriptions. Conclusions : Based on the assumption that classical texts are available in data form to be processed by programs, current research methodology demonstrated that it was more efficient in regards to time and man power to create a pulse description database compared to when the researcher manually created one.

병인변증과 요골동맥 맥상파의 특성 파악을 위한 탐색적 관찰 연구 : 임상시험 프로토콜 개발 (Development of Clinical Protocol on the Correlation Between Disease Cause Pattern Identification and Pulse Wave Variables)

  • 김지혜;유하나;구본초;김현호;김종열;전영주
    • 동의생리병리학회지
    • /
    • 제28권6호
    • /
    • pp.662-667
    • /
    • 2014
  • The purpose of this clinical study is to develop structured clinical trial protocol and guideline for improvement of safety, useful and effective of pulse diagnosis devices. As a first step, papers on pulse diagnosis and pulse diagnosis devices from 2001 and 2013 were systematically reviewed. In the next step, we have collected the opinions from the specialists, companies, and statistician in pulse diagnosis to evaluate the current condition, the state and problem of domestic clinical trial cases of pulse diagnosis device. And we have to created protocol and case report form (CRF) in regards to site condition and characteristics of pulse diagnosis devices, and showed the guideline of eligibility criteria, operation process, investigation items, evaluation items and so on. This clinical protocol will become a basic information for a researcher in designing or performing a clinical study of pulse diagnosis devices, and be used as a useful material during acquisition of good clinical data. Furthermore, we hope to enhance the invigoration of pulse diagnosis clinical trials and the performance improvement of pulse diagnosis devices.

맥진기 결과에 대한 판독자간의 판독 일치율 비교 연구 (Comparative Studies on the Concordance Rate of Pulse Condition Interpretation between Interpreters and Pulse Analyser)

  • 강세영;장인수;김락형
    • Korean Journal of Acupuncture
    • /
    • 제28권4호
    • /
    • pp.91-99
    • /
    • 2011
  • Objectives : The purpose of our investigation is to determine degrees of concordance rate among interpreters. Furthermore, we have examined how much concordance rate to come out when beginners have been compared with the pulse analyzer. Methods : Thirty-nine volunteers were enrolled for this study. These subjects took a 5-minute rest in a sitting position as instructed by the protocol. As they were not allowed to move or speak, radial artery pulse conditions were measured on the lower arm of each subject by means of the pulse analyzer under investigation. Two Korean medical doctors, who did not know the status of default pulse conditions, were also instructed to intuitively choose the most corresponding one in comparison with 13 default pulse conditions. Subsequently, we investigated results between interpreters as well as results between interpreter and pulse analyzer. Results : The total concordance rate, with similar concordance rates being included, between interpreters, between interpreter A and pulse analyzer, and between interpreter B and pulse analyzer was 56.4%, 79.5%, and 71.8% respectively. In faint fine weak pulse(微細弱脈) case, interpreter A and B selected 6 and 7 cases respectively, matched the concordance rate 5, and corresponded separately with the pulse analyzer interpreting 8 cases. Conclusions : In case of skipping pulse 2(促2脈), short pulse(短脈), faint fine weak pulse(微細弱脈), the concordance between interpreters also matches with results drawn from the pulse analyzer. The concordance rate goes higher in proportion with such smaller pulse conditions as faint fine weak pulse(微細弱脈) and short pulse(短脈).

Multiple consecutive-biphasic pulse stimulation improves spatially localized firing of retinal ganglion cells in the degenerate retina

  • Jungryul Ahn;Yongseok Yoo;Yong Sook Goo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제27권6호
    • /
    • pp.541-553
    • /
    • 2023
  • Retinal prostheses have shown some clinical success in restoring vision in patients with retinitis pigmentosa. However, the post-implantation visual acuity does not exceed that of legal blindness. The reason for the poor visual acuity might be that (1) degenerate retinal ganglion cells (RGCs) are less responsive to electrical stimulation than normal RGCs, and (2) electrically-evoked RGC spikes show a more widespread not focal response. The single-biphasic pulse electrical stimulation, commonly used in artificial vision, has limitations in addressing these issues. In this study, we propose the benefit of multiple consecutive-biphasic pulse stimulation. We used C57BL/6J mice and C3H/HeJ (rd1) mice for the normal retina and retinal degeneration model. An 8 × 8 multi-electrode array was used to record electrically-evoked RGC spikes. We compared RGC responses when increasing the amplitude of a single biphasic pulse versus increasing the number of consecutive biphasic pulses at the same stimulus charge. Increasing the amplitude of a single biphasic pulse induced more RGC spike firing while the spatial resolution of RGC populations decreased. For multiple consecutive-biphasic pulse stimulation, RGC firing increased as the number of pulses increased, and the spatial resolution of RGC populations was well preserved even up to 5 pulses. Multiple consecutive-biphasic pulse stimulation using two or three pulses in degenerate retinas induced as much RGC spike firing as in normal retinas. These findings suggest that the newly proposed multiple consecutive-biphasic pulse stimulation can improve the visual acuity in prosthesis-implanted patients.

고차 조화 모드록킹된 반도체-광섬유 레이저 구성과 출력 광펄스의 압축 (Harmonically mode-locked semiconductor-fiber ring laser and the output pulse compression)

  • 김동환
    • 한국광학회지
    • /
    • 제10권1호
    • /
    • pp.58-63
    • /
    • 1999
  • 광반도체 증폭기를 이용하여 $1.5\mu\textrm{m}$파장 영역에서 발전하는 조화 모드 록킹된 10GHz 고리형 반도체-광섬유 레이저를 구현하였다. 레이저 펄스폭은 13~18ps이고, 파장 선폭은 0.4~0.6nm이며, 양으로 주파수 처핑되었다. 2km 길이의 표준단일 모드 광섬우를 이용하여 4dBm의 평균 출력을 갖는 레이저 펄스를 광섬유의 군분산 보상에 의해 펄스폭을 최대 6.8ps까지 압축시켰다.

  • PDF

6펄스 콘버어터로 제어되는 초전도 에너지 저장장치에 의한 전력계통 안정화

  • 차귀수;한송엽;원종수
    • 대한전기학회논문지
    • /
    • 제35권8호
    • /
    • pp.353-362
    • /
    • 1986
  • This paper shows that 6 pulse converter instead of 12 pulse converter can be used for the control of Superconducting Magnet Energy Storage(SMES) to improve the stability and to suppress the voltage fluctuation of power system. In order to prevent the commutation failure, when 6 pulse converter used for simultaneous control of real power and reactive power is asymmetrically controlled, stable control region has been presented by analyzing the commutation phenomena at critical points which distinguish the stable control region from the unstrol control region. Harmonic components of line current and output voltage have been calculated. Finally, computer simulation of power system stabilization has been presented to show the effectiveness of the proposed method. According to the computation results, SMES controlled by the 6 pulse converter is an effective measure in reducing the oscillation and the transient instability of the power system.

  • PDF

Reduced Rating T-Connected Autotransformer Based Thirty-Pulse AC-DC Converter for Vector Controlled Induction Motor Drives

  • Singh Bhim;Bhuvaneswari G.;Garg Vipin
    • Journal of Power Electronics
    • /
    • 제6권3호
    • /
    • pp.214-225
    • /
    • 2006
  • The design and performance analysis of a reduced rating autotransformer based thirty-pulse AC-DC converter is carried out for feeding a vector controlled induction motor drive (VCIMD). The configuration of the proposed autotransformer consists of only two single phase transformers, with their windings connected in a T-shape, resulting in simplicity in design, manufacturing and in a reduction in magnetics rating. The design procedure of the autotransformer along with the newly designed interphase transformer is presented. The proposed configuration has flexibility in varying the transformer output voltage ratios as required. The design of the autotransformer can be modified for retrofit applications, where presently a 6-pulse diode bridge rectifier is used. The proposed thirty-pulse AC-DC converter is capable of suppressing less than $29^{th}$ harmonics in the supply current. The power factor is also improved to near unity in the wide operating range of the drive. A comparison of different power quality indices at AC mains and DC bus is demonstrated in a conventional 6-pulse AC-DC converter and the proposed AC-DC converter feeding a VCIMD. A laboratory prototype of the proposed autotransformer based 30-pulse AC-DC converter was developed with test results validating the proposed design and system.