• Title/Summary/Keyword: 6 pulse

Search Result 2,155, Processing Time 0.031 seconds

Production of Pyruvate Dehydrogenase Complex-E2 Specific Human Monoclonal Antibody in Fed-batch Culture Systems with High Cell Density Recombinant Escherichia coli (고농도 재조합 대장균의 Fed-batch 배양 시스템을 이용한 Pyruvate Dehydrogenase Complex-E2 특이성 인간 모노클론 항체의 생산)

  • 이미숙;전주미;차상훈;정연호
    • KSBB Journal
    • /
    • v.15 no.5
    • /
    • pp.489-496
    • /
    • 2000
  • Several culture systems including batch, two-stage CSTR, semi-fed batch, and two-stage cyclic fed-batch were investigated for the efficient production of the Fab fraction of PDC-E2 specific human monoclonal antibody using high cell density recombinant E. coli. A two-phase batch system and a two-stage continuous system were examined to overcome plasmid instability problems, by separating the growth and the production stages. The cell density and productivity of the two-stage continuous culture was better than that of the two-phase batch fermentation. In the two-stage continuous culture system with DO-stat, the cell growth and the productivity were superior to those of the system without the DO control. Also, almost total plasmid stability was maintained in the two-stage continuous culture system. Modified M9 medium was selected as an optimum feeding medium for the fed-batch process, and the optimum C/N ratio determined to be 2:3. The optimum feeding rate was $0.6g/\ell/hr$ for a constant feeding strategy in semi-fed batch system. When the feeding medium was fed by pulsing, it was observed that more frequent pulsing resulted in improved cell growth. The linear feeding method was the most efficient of the various feeding methods tested. Finally, high cell density culture using a two-stage cyclic fed batch system with pH-stat was tried because the linear feeding method showed limitations in terms of obtaining high cell densities, and a cell density of $54 g/\ell$ was achieved. It was concluded that the two-stage cyclic fed batch system was the most efficient system for high cell density culture of the systems tested. However, productivity improvements were lower than expected due to the extremely high accumulations of acetate, although the low levels of residual glucose were maintained.

  • PDF

Ultasonic Reflection Characteristics of the Underwater Corner Reflector (수중코오너리프렉터의 초음파반사특성에 관한 연구)

  • Lee, Dae-Jae;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.1
    • /
    • pp.25-32
    • /
    • 1983
  • The corner reflector is used to increase the echoing area of radar targets in the air, and it can also be applied to increase the echoing area of the sonar targets under water. As the basic research for this application, the authors investigated the ultrasonic reflection characteristics under water for the corner reflector which was made of aluminum plate. The experiments were made by pulse measuring method with the magnetostrictive ferrite transducers of 28, 50 and 75KHz in the experimental water tank. The results obtained are as follows; 1. The target strength of corner reflectors were increased in proportion to the diameter and were greater at higher frequency of 75KHz than at lower frequency of 28KHz. 2. In the case of 5 corner reflectors of 150mm in diameter which have corner angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$the measured values of the maximum target strength at 75KHz were-25.0 dB, -17.2dB, -15.1dB, -13.4dB and 11.0dB, and then the number of main lobes showing the maximum target strength in the backscattering patterns were 24, 12, 8, 6 and 4, respectively. 3. When 7 corner reflector of 80mm in diameter and 90$^{\circ}$ in the corner angle was located on the minor axis of the horizontal section with directional angles of 0$^{\circ}$, 2.5$^{\circ}$, 5.0$^{\circ}$, 7.5$^{\circ}$, 10$^{\circ}$ and 12.5$^{\circ}$ against the sound beam axis, the measured values of the target strength on each position at 75KHz were -21.2dB, -21.9dB, -26.0dB, -30.5dB and -36.8dB, respectively.

  • PDF

Development of 3D Viewer for Tree Cavity using Pulse Ultrasound (펄스 초음파를 이용한 수목 공동부 3D 구현 프로그램 제작)

  • Son, Jungmin;Kang, Sunghoon;Moon, Jongwook;Yoon, Seokkyu;Park, Jikoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.265-271
    • /
    • 2021
  • The pattern of the tree's internal swelling depends on many causes. Since it is difficult to detect these various causes of swelling with a general method, if the state of swelling for a long time cannot be confirmed, serious damage to the trees may occur due to enlargement of the swelling area. In the method of acquiring a tree tomography image, an impulse passing through the tree is generated by tapping the sensor with a rubber mallet, and the moving speed is recorded. In this paper, to measure cracks, cavities, and swelling due to physical damage, we developed a 3D viewer that can know the internal state of a tree using a tree cross-section image acquired from Arbotom to determine the degree of swelling inside the tree. Based on this, we tried to present data that can be referred to when surgical operation of trees is required. In order to acquire a tomographic image of a tree, 6 sensors were attached to the three Yangpala and Maple trees, and a 1 m-long tree was measured using the Arbotom program, and a 3D image was implemented through the 3D Viewer created using MATLAB. In addition to simply acquiring images, the cross-sectional length and volume of the tree were measured. In the actually produced 3D Viewer, the length of the part where the swelling of the maple tree occurred was 33.12 cm, and the swelling of the yangpala tree was measured as 21.41 cm. The volume of the maple tree was measured to be 78.832 ㎤. As a result of comparing the cross-sectional image of the Arbotom and the 3D image, the same result as the real aspect of the tree was obtained, so it can be judged that the reliability of the manufactured software is also secured, and data to be applied to the surgical tree operation through the created Viewer is provided. It is believed that the damage will be minimized.

Administration of Yijung-tang, Pyeongwi-san, and Shihosogan-tang for Standardization of Korean Medicine Pattern Identification for Functional Dyspepsia: A Study Protocol of a Randomized, Assessor-blind, 3-Arm, Parallel, Open-label, Multicenter Clinical Trial (기능성 소화불량 한의 변증 표준화를 위한 이중탕, 평위산 및 시호소간탕 투여 : 무작위 배정, 평가자 눈가림, 3군 비교, 평행 설계, 공개, 다기관 임상시험 프로토콜)

  • Boram Lee;Min-Jin Cho;Young-Eun Choi;Ojin Kwon;Mi Young Lim;Seok-Jae Ko;So-yeon Kim;Yongjoo Kim;Donghyun Nam;Dong-Jun Choi;Jun-Hwan Lee;Jae-Woo Park;Hojun Kim
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.6
    • /
    • pp.1105-1121
    • /
    • 2022
  • Objectives: The purpose of this study is to explore the effectiveness and safety of frequently used clinical herbal medicines (Yijung-tang [Lizhong-tang, LJT], Pyeongwi-san [Pingwei-san, PWS], and Shihosogan-tang [Chaihu Shugan-tang, SST]) in patients with functional dyspepsia (FD) when administered according to herbal medicine and Korean medicine pattern identification. The results of this study will be used to standardize the diagnostic instrument used in Korean medicine and to investigate biomarkers of Korean medicine pattern identification. Methods: This study will be a randomized, assessor-blind, 3-arm, parallel, open-label, multi-center clinical trial. A total of 300 FD participants will be recruited from 3 Korean medical hospitals and assigned to the LJT (n=100), PWS (n=100), and SST (n=100) groups according to FD pattern identification. The patients will take the medication for 8 weeks, 3 times a day, before or between meals. The primary outcome will be total dyspepsia symptom (TDS) and the secondary outcomes will be adequate relief (AR) for dyspepsia, overall treatment effect (OTE), visual analogue scale (VAS), functional dyspepsia-related quality of life (FD-QoL), gastrointestinal symptom score (GIS), and pattern identification questionnaires. For the exploratory outcomes, we will analyze blood and fecal metabolome profiles, microbiota from fecal and saliva samples, single nucleotide polymorphism (SNP), and results of Korean medicine diagnosis device measurements (heart rate variability, and tongue, pulse, and abdominal diagnosis). Conclusions: The results of this study will prove objectivity for Korean medicine pattern identifications, and the effectiveness and safety of herbal medicines for the population with FD.

Analysis of Childhood Rapidly Progressive Glomerulonephritis (소아 급속 진행성 사구체신염의 임상적 고찰)

  • Uhm Ji Hyun;Kim Mi Jin;Lee Young-Mock;Kim Ji Hong;Lee Jae Seung;Kim Pyung-Kil;Hong Soon Won;Jeung Hyeun Joo
    • Childhood Kidney Diseases
    • /
    • v.5 no.2
    • /
    • pp.78-86
    • /
    • 2001
  • Purpose: Rapidly progressive glomerulonephritis (RPGN) is characterized by the rapid increase in serum creatitnin and crescents formation involving more than $50\%$ of glomeruli. 10 patients who had been treated for RPGN were studied retrospectively for thier underlying diseases and clinical features Method: Cilinical review was performed on 10 children who were diagnosed with RPGN by clinical features and renal biopsy and followed up at department of pediatrics during tile last 10 years, from May 1990 to May 2000. Result: There were 6 males and 4 females between the ages of 2.1 and 14.3 years (mean $10.9{\pm}3.8$). 3 had Henoch-$Sch{\ddot{o}}nlein$ purpura nephritis; 2, idiopathic rapidly progressive glomerulonephritis; 2, lupus nephritis; 1, hemolytic uremic syndrome; 1, membranous glomerulonephritis and 1, microscopic polyangiitis. The most common chief complaints were gross hematuria and oliguria. Initial clinical features included proteinuria, edema, hypertension, nausea and arthralgia. Mean serum BUN was $74.2{\pm}39.1\;mg/dL$ mean serum creatinin, $3.2{\pm}1.8\;mg/dL$ and mean creatinin clearance, $26.5{\pm}13.2\;mL/min/1.73m^2$. Antineutrophil cytoplasmic antibody was positive only in microscopic polyangiitis. ANA and Anti-DNA antibody were positive in two lupus nephritis patients. Serum complements were decreased in 4 patients. All patients except Hemolytic uremic syndrome received steroid pulse therapy and immunosupressive agents. 3 patients were performed acute peritoneal dialysis and 2 patients were given plasmapheresis. At the last follow up, 1 patient was dead, 4 patients had elevated serum creatinin, 2 of these 4 patients were on chronic ambulatory peritoneal dialysis and 6 patients had normal renal function. Conclusion: Rapidly progressive glomerulonephritis is a medical emergency that requires very rapid diagnosis, classification, and therapy. Appropriate therapy selected on the basis of underlying disease mechanism can substantially improve renal survival. (J. Korean Soc Pediatr Nephrol 2001 ; 5 : 78-86)

  • PDF

The Comparative Study of on Pump CABG during Pulsatile $(T-PLS^{TM})$ and Nonpulsatile $(Bio-pump^{TM})$ Perfusion (관상동맥우회술 시 사용된 박동성펌프$(T-PLS^{TM})$와 비박동성펌프$(Bio-pump^{TM})$의 비교연구)

  • Park Young-Woo;Her Keun;Lim Jae-Ung;Shin Hwa-Kyun;Won Yong-Soon
    • Journal of Chest Surgery
    • /
    • v.39 no.5 s.262
    • /
    • pp.354-358
    • /
    • 2006
  • Background: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of $T-PLS^{TM}$ through the comparison of clinical effects of $T-PLS^{TM}$ (pulsatile pump) and $Bio-pump^{TM}$ (non-pulsatile pump) used for coronary bypass surgery. Material and Method: The comparison was made on 40 patients who had coronary bypass using $T-PLS^{TM}\;and\;Bio-pump^{TM}$ (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. Result: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with $T-PLS^{TM}\;(46{\pm}15\;mmHg\;in\;T-PLS^{TM}\;vs\;35{\pm}13\;mmHg\;in\;Bio-pump^{TM},\;p<0.05)$. The $T-PLS^{TM}$-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant $(9.7{\pm}3.9\;cc/min\;in\;T-PLS^{TM}\;vs\;8.9{\pm}3.6\;cc/min\;in\;Bio-pump^{TM},\;p=0.20)$. There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with $T-PLS^{TM}\;(24.5{\pm}21.7\;mg/dL\;in\;T-PLS^{TM}\;versus\;46.8{\pm}23.0mg/dL\;in\;Bio-pump^{TM},\;p<0.05)$. There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with $T-PLS^{TM}$, but the death rate was not statistically significant. Conclusion: Coronary bypass was operated with $T-PLS^{TM}$ (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which $Bio-pump^{TM}$ was used. In addition, $T-PLS^{TM}$ used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of $T-PLS^{TM}$.

The Respiratory and Hemodynamic Effects of Prone Position According to the Level of PEEP in a Dog Acute Lung Injury Model (잡종견 급성폐손상 모델에서 Prone position 시행시 PEEP 수준에 따른 호흡 및 혈류역학적 효과)

  • Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.1
    • /
    • pp.140-152
    • /
    • 1998
  • Background: Prone position improves oxygenation in patients with ARDS probably by reducing shunt Reduction of shunt in prone position is thought to be effected by lowering of the critical opening pressure (COP) of the dorsal lung because the pleural pressure becomes less positive in prone position compared to supine position. It can then be assumed that prone position would bring about greater improvement in oxygenation when PEEP applied in supine position is just beneath COP than when PEEP is above COP. Hemodynamically, prone position is expected to attenuate the lifting of cardiac fossa induced by PEEP. Based on these backgrounds, we investigated whether the effect of prone position on oxygenation differs in magnitude according to the level of PEEP applied in supine position, and whether impaired cardiac output in supine position by PEEP can be restored in prone position. Methods: In seven mongrel dogs, $PaO_2/F_1O_2$(P/F) was measured in supine position and at prone position 30 min. Cardiac output (CO), stroke volume (SV), pulse rate (PR), and pulmonary artery occlusion pressure (PAOP) were measured in supine position, at prone position 5 min, and at prone position 30 min. After ARDS was established with warmed saline lavage(P/F ratio $134{\pm}72$ mm Hg), inflection point was measured by constant flow method($6.6{\pm}1.4cm$ $H_2O$), and the above variables were measured in supine and prone positions under the application of Low PEEP($5.0{\pm}1.2cm$ $H_2O$), and Optimal PEEP($9.0{\pm}1.2cm$ $H_2O$)(2 cm $H_2O$ below and above the inflection point, respectively) consecutively. Results : P/F ratio in supine position was $195{\pm}112$ mm Hg at Low PEEP and $466{\pm}63$ mm Hg at Optimal PEEP(p=0.003). Net increase of P/F ratio at prone position 30 min, however, was far greater at Low PEEP($205{\pm}90$ mm Hg) than at Optimal PEEP($33{\pm}33$ mm Hg)(p=0.009). Compared to CO in supine position at Optimal PEEP($2.4{\pm}0.5$ L/min), CO in prone improved to $3.4{\pm}0.6$ L/min at prone position 5 min (p=0.0180) and $3.6{\pm}0.7$ L/min at prone position 30 min (p=0.0180). Improvement in CO was attributable to the increase in SV: $14{\pm}2$ ml in supine position, $20{\pm}2$ ml at prone position 5 min (p=0.0180), and $21{\pm}2$ ml at prone position 30 min (p=0.0180), but not to change in PR or PAOP. When the dogs were turned to supine position again, MAP ($92{\pm}23$ mm Hg, p=0.009), CO ($2.4{\pm}0.5$ L/min, p=0.0277) and SV ($14{\pm}1$ ml, p=0.0277) were all decreased compared to prone position 30 min. Conclusion: Prone position in a dog with saline-lavaged acute lung injury appeared to augment the effect of relatively low PEEP on oxygenation, and also attenuate the adverse hemodynamic effect of relatively high PEEP. These findings suggest that a PEEP lower than Optimal PEEP can be adopted in prone position to achieve the goal of alveolar recruitment in ARDS avoiding the hemodynamic complications of a higher PEEP at the same time.

  • PDF

Effect of Academic Examination Stress on Taste Perception and Nutrient Intake in University Students (대학생의 시험 스트레스가 미각과 영양소 섭취에 미치는 영향)

  • 전예숙;최미경
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.349-355
    • /
    • 2004
  • The purpose of this study was to estimate effect of academic examination stress on taste perception and nutrient intakes in university students. Physical status, blood pressure, stress score using stress test of 2 types, recognition threshold and preference for taste, nutrient intakes using diet record method were measured before and after examination in 20 subjects. Mean age, height, weight, and BMI of the subjects were 23.39$\pm$1.20 years, 164.56$\pm$7.99 cm, 60.66$\pm$13.23 kg, 22.28$\pm$4.56 kg/$m^2$, respectively. Stress scores before examination of the subjects were significantly higher than those after examination. There were no significant differences in blood pressure, pulse rate, recognition threshold and just right concentration for sweetness and saltness, and food and nutrient intakes between pre- and post-examination. There were significantly positive correlation between stress score and diastolic blood pressure. And threshold concentration for saltness was positively correlated with threshold concentration for sweetness and animal protein intake. These results show no effect of examination stress on taste perception and nutrient intakes in university students. This may be due to low level of stress. Therefore, it is needed to study about effect of more higher level of stress on taste perception and nutrient intakes.

A Study on Usefulness of Specific Agents with Liver Disease at MRI Imaging: Comparison with Ferucarbotran and Gd-EOB-DTPA Contrast Agents (간 병변 특이성 조영제 자기공명영상에 대한 연구: Ferucarbotran과 Gd-EOB-DTPA 조영제의 비교)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Choi, Yong-Seok
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.235-243
    • /
    • 2009
  • The purpose of this experiment is to know the relation of the detection and characterization of liver's diseases as comparison of finding at MR imaging using a Ferucarbotran (SPIO) and Gd-EOB-DTPA (Primovist) agents in diffuse liver disease. A total of 50 patients (25 men and 25 women, mean age: 50 years) with liver diseases were investigated at 3.0T machine (GE, General Electric Medical System, Excite HD) "with 8 Ch body coil for comparison of diseases and contrast's uptake relation, which used the LAVA, MGRE." All images were performed on the same location with before and after Ferucarbotran and Gd-EOB-DTPA administrations (p<0.05). Contrast to noise ratio of Ferucarbotran and Gd-EOB-DTPA in the HCC were $3.08{\pm}0.12$ and $7.00{\pm}0.27$ with MGRE and LAVA pulse sequence, $3.62{\pm}0.13$ and $2.60{\pm}0.23$ in the hyper-plastic nodule, $1.70{\pm}0.09$ and $2.60{\pm}0.23$ in the meta, $2.12{\pm}0.28$ and $5.86{\pm}0.28$ in the FNH, $4.45{\pm}0.28$ and $1.73{\pm}0.02$ in the abscess and ANOVA test was used to evaluate the diagnostic performance of each disease (p<0.05). In conclusions, two techniques were well demonstrated with the relation of the detection and characterization of liver's diseases.

  • PDF

Brown Color Characteristics and Antioxidizing Activity of Doenjang Extracts (된장의 지용성ㆍ수용성추출물에 대한 갈색 특성 및 항산화 효과)

  • 김현정;손경희;채선희;곽동경;임성경
    • Korean journal of food and cookery science
    • /
    • v.18 no.6
    • /
    • pp.644-654
    • /
    • 2002
  • Brown color characteristics and antioxidizing activities were investigated for Doenjang under different processing conditions. Doenjang A was prepared directly from Meju and saline solution whereas Doenjang B was Prepared after separating soy sauce by soaking for 45 days. Both Doenjangs were aged for up to 180 days. Antioxidizing activity was studied in relation to the brown color characteristics using fat-soluble extract and water-soluble extract of Doenjang. The intensity of brown color was higher in the water-soluble Doenjang extract than the fat-soluble Doenjang extract. In the UV-VIS scanning spectra, water-soluble Doenjang extracts showed significant changes as the aging proceeded, but fat-soluble Doenjang extract did not. Antioxidizing activity of fat-soluble Doenjang extract increased as the aging period extended; however, no significant difference was detected in the water-soluble extract. Overall, Doenjang A showed higher contents of amino acids, reducing sugar, brown color, and antioxidizing activity, and the antioxidizing ability was higher in water-soluble Doenjang extract rather than in the fat-soluble Doenjang extract.