• 제목/요약/키워드: 6 pulse

검색결과 2,150건 처리시간 0.028초

Pulse UV 장치를 이용한 원유비축시설 발생폐수의 난분해성 유기오염물질 제거 (Removal of Non-biodegradable Organic Contaminants in Wastewater from crude oil reserve base Using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.861-867
    • /
    • 2011
  • Wastewater from crude oil reserve base usually contains large amount of non-biodegradable contaminants. The conventional wastewater treatment progress can hardly meet the regulation of wastewater effluent quality. This study investigated the removal of non-biodegradable organic contaminants in wastewater from crude oil reserve base using a pulse UV treatment. The modified process incorporating pulse UV process was set up to treat the wastewater from crude oil reserve base. The treatment process is composed with coagulation and flocculation, micro-bubble flotation, sand filter, pulse UV system, and GAC filter. The results show CODMn was effectively removed by the process with pulse UV system and it can meet the wastewater effluent regulation. The single effect of pulse UV process in CODMn removal was not significant(9~15% based on sand filtered effluent), however with the subsequent activated carbon filter the removal ratio CODMn was increased up to 28% compared to the process without pulse UV syetem.

표시기간 중첩 프라이밍 구동기술에 의한 플라즈마 디스플레이 패널의 고속구동특성 (High-Speed Characteristics of Plasma Display Panel using Priming Overlapping with Display Drive Method)

  • 염정덕
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.2004-2009
    • /
    • 2007
  • A new high-speed drive method for the plasma display panel is proposed. In this method, the address period is inserted for the rest period of the sustain pulses and the priming pulse is applied on the entire panel at the same time overlapping with the sustain period. The ramp shaped priming pulse can be made with a simple drive circuit in this technology and the stable sustain discharge can be induced even by a narrow scan pulse in help of the space charge generated from the address discharge. From the experiments, it is ascertained that the priming pulse hardly influences the sustain discharge. Moreover, the voltage margin of the sustain discharge is almost constant though that of the address discharge broadens with narrowing the scan pulse width. And, if the time interval between the scan pulse and the sustain pulse is within $6{\mu}s$, the voltage margin of the address and the sustain discharges are unaffected though the applied position of the scan pulse is changed. High-speed driving with the address pulse of $0.7{\mu}s$ width was achieved and the address voltage margin of 20V and the sustain voltage margin of 10V were obtained.

ECG 파형과 홀소자 맥진파형으로 동시 측정한 맥파전달속도 특성 연구 (Characteristics of Pulse Wave Velocity by the Simultaneously Measured ECG Waveform and Hall Device Radial Artery Waveform)

  • 유재영;최슬기;김담비;이상석
    • 한국자기학회지
    • /
    • 제22권4호
    • /
    • pp.136-141
    • /
    • 2012
  • 본 연구에서는 집게형 맥진기와 심전도계를 이용하여 전기적인 심전도 파형과 요골동맥파형을 동시 측정하여 얻은 맥파전달속도를 분석하였다. 두 신호의 동시 측정에 의한 맥파전달속도는 평균 6 m/s의 값을 보여 주었으며, ECG 파형과 홀소자 맥진파형으로 동시 측정한 방법은 기존 방법들 보다 정확하게 맥파전달속도를 측정할 수 있는 새로운 방법임을 입증하였다. 따라서 이결과는 한방의료기기인 맥진기에서 측정된 데이터를 임상적으로 활용할 수 있음을 보인다.

이광자 형광법과 비공선 일종 이차고조파법에 의한 피코초 레이저 펄스폭과 펄스형 측정 (Measurement of picosecond laser pulsewidth and pulseshape by two-photon fluorescence and noncolloinear type I second harmonic generation method)

  • 한기호;박종락;이재용;김현수;엄기영;변재오;공흥진
    • 한국광학회지
    • /
    • 제7권3호
    • /
    • pp.251-259
    • /
    • 1996
  • 주 공진기 Nd:YLF 레이저에서 Q-switching and mode-locking(QSML)된 펄스열로부터 단일 펄스를 선택한 후 4중경로 Nd:glass 레이저 증폭기를 통과시켜 얻은 증폭된 빔의 펄스폭을 이광자 형광법으로 측정하였고 비공선 일종 이차고조파법을 이용하여 CW mode-locked 펄스열의 자기상관을 구해 펄스폭과 함께 펄스형을 결정하였다. 측정된 TPF 자기상관 패턴은 QSML 펄스열에서 단일 펄스를 선택하는 위치에 따라 다른 양상을 보였다. 즉, 펄스열 전반부에서 선택된 펄스의 자기상관은 곡선이 부드러운 펄스형을 보이는 반면, 펄스열 후반부일 때는 예리한 spike와 중앙의 substructure를 나타냈다. TPF법에 의한 증폭된 빔의 자기상관으로부터 펄스폭은 44.4ps, 대비비는 2.86로 측정되었으며 이 대비비로부터 펄스와 배경을 합한 전체 에너지에 대한 펄스의 에너지비 E$_{p}$/E$_{total}$ =0.62를 구할 수 있었고 또한 mode-locking만 된 펄스를 사용한 SHG 자기상관 실험에서는 펄스폭이 46.6ps로 측정되었다. 한편, 측정된 SHG 자기상관 신호를 여러 펄스형으로 fitting한 결과 펄스형이 sech$^{2}$형에 가까움을 확인할 수 있었다. 이 펄스형을 이용한 시뮬레이션을 통해 4중경로 증폭기를 통과한 펄스의 펄스폭 감소 효과를 확인하였다.다.

  • PDF

『상한론(傷寒論)·평맥법(平脈法)』에 관한 연구(1) (The study on ShanghanLun PingMaiFa (1))

  • 최진영;박광천;정한솔;하기태;신상우
    • 한국의사학회지
    • /
    • 제25권2호
    • /
    • pp.63-96
    • /
    • 2012
  • The PingMaiFa chapter, which is the second chapter of SongBon ShangHanLun, is the scholarly description(專論) of the pulse and pathological mechanism but has not been studied and published yet. This study is about article 1-13 which is the first part of The PingMaiFa chapter. We compared the original texts within the editions, comparing and analyzing the annotations of successive dynastic medical group. The articles of The SongBon ShangHanLun PingMaiFa chapter 1-13 is consisted as is shown: article 1 states about the general features of normal pulse (平脈) and its physiological mechanism and the morbid pulses (病脈) caused by wind, cold, retained fluid, pain and heat vexation, article 1,10 state about the normal pulses of Five viscera (lung, heart, spleen, liver and kidney) and their manipulations in pulse taking, article 2 states about the differentiations of deficiency and excess syndrome according to pulse conditions, article 3, 4 state about the estimation of good prognoses and a factitious disorder by the combination of pulses and symptoms, article 6 states about Latent qi (伏氣) and its diagnostic features, article 5 states about inspection and listening examination as co-diagnostic methods of the pulse diagnosis, article 7, 8, 9 state that the emotions, such as fear and shame, and the dietary are important factors to consider for making diagnosis, article 11 states about the overwhelming pulse (相乘脈) which indicates the abnormal correlations between five phases and appears in four patterns as the dissolute(縱), the unrighteous(橫), the unfavorable(逆) and the favorable(順), article 12 states about 6 harmful pulses(殘賊脈), which are string-like pulse(弦脈), tight pulse(緊脈), floating pulse(浮脈), slippery pulse(滑脈), sunken pulse(沈脈), rough pulse(澁脈), article 13 states about "JaeGoe"(災怪) which is an unexpected response after treatment and it comes because of the formulas that had before. Throughout all these articles, The PingMaiFa chapter not only offers great value for Pulse-taking diagnosis, but also leads to a better understanding of clinical applications.

중풍환자의 변증에 따른 맥상의 분포 (Study on the Pulse Diagnosis for Pattern Identifications in Stroke Patients)

  • 이정섭;강병갑;고미미;김보영;김정철;이인;김윤식;조기호;최선미;방옥선
    • 동의생리병리학회지
    • /
    • 제22권6호
    • /
    • pp.1378-1382
    • /
    • 2008
  • This study is aim to evaluate pulse diagnosis as indicators for classification of the pattern identifications in stroke patients. To get the clinical information, we recruited the onset 1 month stroke patients through the multicenter network which consists of 13 oriental hospitals. The clinical informations about three pairs of pulse wave form and levels of their significancy based on the case report form (CRF) were collected and their distribution in each pattern identification were analyzed. The results are as follows Fire-Heat group shows high portions of floating pulse, rapid pulse and solid pulse. Qi Defficiency group has a greater portion of deep pulse, slow pulse, deficient pulse. The well-defined character of Phlegm-Retained Fluid, Yin Defficiency, Static Blood groups cannot be explained by pulse wave form. These results show a rough relationship between the pulse diagnosis and pattern identifications of stroke therefore, further studies are required to determine the pulse diagnosis as significant indicators of stroke pattern identification.

SMPS 방식의 고반복 펄스형 $CO_2$ 레이저의 전원장치 개발 (The development of power supply of High-Repetition Pulsed $CO_2$ Laser using SMPS)

  • 이동훈;정현주;김도완;김희제
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 제11회 정기총회 및 00년 동계학술발표회 논문집
    • /
    • pp.316-317
    • /
    • 2000
  • 펄스형 $CO_2$레이저는 적외선 영역인 10.6 $mu extrm{m}$ 파장의 매우 안정된 고출력 펄스를 방출시킬 수 있으므로 산업용, 군사용, 의료용, 각종 물리.화학의 기초 연구용 등의 광범위한 응용 분야에서 각광을 받고 있다. 특히 금속의 정밀절단, 심용접에서는 수 십 Hz로부터 수 kHz의 펄스 출력이 필요하다. 펄스방식은 Normal Pulse와 Super Pulse로 크게 나눌 수 있다. Normal Pulse의 경우에는 Pulse의 파고치가 연속파의 파고치와 동일하기 때문에 펄스시의 평균 출력은 연속파의 경우보다 낮다. Super Pulse의 경우에는 Pulse 파고치를 연속파의 파고치보다 훨씬 높게 할 수 있으므로 평균 출력은 낮지만 첨두 출력이 높아서 유리 등 세라믹 재료의 가공에 널리 사용된다$^{(1)}$ (중략)

  • PDF

전극의 재료와 크기가 방전가공량에 미치는 영향 (Influence on Metal Removal Rate by Material and Size Difference of the Electrode)

  • 김희중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.809-815
    • /
    • 1998
  • This study has been performed to investigate MRR(metal removal rate) surface roughness with various pulse-on duration using the copper and graphite electrode according to the electrode size on the heat treated STD 11 which is extensively used for metallic molding steel in the EDM. The results obtained are as follow ;a)MRR increases a lot when pulse-on duration is 100 $\mu{s}$ or less but MRR has little difference with pulse-on duration of 100 $\mu{s}$ or more b) According to the increase of Pulse-on duration the large the electrode size the more MRR c) Safe discharge is needed to make maximum of MRR and the metallic organization must be complicated for discharge induction. d) Actual machining time is longer than theoretical machining time at the short pulse-on duration because of skin effect of current. e) Graphite electrode needs the larger electric discharge energy than copper electrode to remove remained chips completely.

  • PDF

마이크로스트립 선로상 가우시안 펄스신호의 전파특성 해석 및 측정 (Propagation characteristic analysis and measurement of gaussian pulse signals on the microstrip line)

  • 이승엽;신호섭;김남;권원현
    • 한국통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.1425-1432
    • /
    • 1998
  • The propagation properties of Gaussian pulse signals on the microstrip line are investigated by the Kirschning & Jansen's approximated equation to meet the frequency range of a pulse, accuracy, and geometrical requiremtns of the microstrip line. The dispersion of pulse signals is analyzed regarding to the relative permittivity .epsilon.$_{r}$, substrate height h and strip width w of the microstrip line. To verify theoretical results, several samples of 50.OMEGA. microstrip lines are fabricated. And the characteristics of pulse propagation along these lines are simple measured using VNA(Vector Network Analyzer) with time-domain analysis function. A fairly good agreement has been found between the measured pulse waveforms and computer simulations.

  • PDF

The effect of Er:YAG laser irradiation on the surface microstructure and roughness of hydroxyapatite-coated implant

  • Kim, Seong-Won;Kwon, Young-Hyuk;Chung, Jong-Hyuk;Shin, Seung-Il;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • 제40권6호
    • /
    • pp.276-282
    • /
    • 2010
  • Purpose: The present study was performed to evaluate the effect of erbium:yttrium-aluminium-garnet (Er:YAG) laser irradiation on the change of hydroxyapatite (HA)-coated implant surface microstructure according to the laser energy and the application time. Methods: The implant surface was irradiated by Er:YAG laser under combination condition using the laser energy of 100 mJ/pulse, 140 mJ/pulse and 180 mJ/pulse and application time of 1 minute, 1.5 minutes and 2 minutes. The specimens were examined by surface roughness evaluation and scanning electron microscopic observation. Results: In scanning electron microscope, HA-coated implant surface was not altered by Er:YAG laser irradiation under experimental condition on 100 mJ/pulse, 1 minute. Local areas with surface melting and cracks were founded on 100 mJ/pulse, 1.5 minutes and 2 minutes. One hundred forty mJ/pulse and 180 mJ/pulse group had surface melting and peeling area of HA particles, which condition was more severe depending on the increase of application time. Under all experimental condition, the difference of surface roughness value on implant surface was not statistically significant. Conclusions: Er:YAG laser on HA-coated implant surface is recommended to be irradiated below 100 mJ/pulse, 1 minute for detoxification of implant surface without surface alteration.