• 제목/요약/키워드: 6 MV

검색결과 874건 처리시간 0.035초

절제 불가능 직장암에서 방사선 치료의 역할 (The Role of Radiation Therapy in the Unresectable Rectal Cancers)

  • 김우철;성진실;김귀언
    • Radiation Oncology Journal
    • /
    • 제13권2호
    • /
    • pp.173-180
    • /
    • 1995
  • Purpose: Unresectable rectal cancer has a grave prognosis. regardless of the therapy used and median survival is less than 1 rear. Also, it is reported by many authors that $50-80\%$ of unresectable lesions were rendered resectable by radiation therapy and the median survival time for the completely resected patients were better than that of the unresected patients. So we analyzed retrospectively our data for the better treatment outcome in these patients. Materials and MEthods:From 1980 to 1992, 45 patients with initially unresectable tumors in the rectum were treated with radiation therapy with/without surgery in Department of Radiation Oncology, Yonsei Cancer Center 10 MV radiation and multiple field technique (box or AP/PA) were used. The total dose was 28-70 Gy and median dose was 48 Gy. We evaluated the lesion status at 45-50 Gy for operability. If the lesions appeared to be resectable, the Patients were operated on 4-6 weeks after radiation therapy. But if the lesions were still fixed, the radiation dose was increased to 60-65 Gy. Results: For all patients, the 2-year actuarial survival was $13.3\%$ and median survival was 9.5 months. Of 6 patients who had received less than 45 Gy, only $17\%$ of patients responded, but in the patients who had received more than 45 Gy, $60\%$ of response rate was achieved Six of the 24 patients$(25\%)$ underwent surgical resections following RT. For patients undergoing curative resection. the two-rear survival was $50\%,$ but that of the patients without resection was $9.5\%$ (p<0.01). Survival of patients with complete response following RT was $50\%$ at 2 years. Survival of patients with partial response, stable disease and progressive disease after RT was $13.4\%,\;15.4\%,\;0\%$ respectively (P<0.05). Conclision: Our data suffests that the efforts which can increase the response rate and aggressive surgical approach are needed to achieve the better local control and survival in unresectable rectal cancers.

  • PDF

Comparison of Dosimetrical and Radiobiological Parameters on Three VMAT Techniques for Left-Sided Breast Cancer

  • Kang, Seong-Hee;Chung, Jin-Beom;Kim, Kyung-Hyeon;Kang, Sang-Won;Eom, Keun-Yong;Song, Changhoon;Kim, In-Ah;Kim, Jae-Sung
    • 한국의학물리학회지:의학물리
    • /
    • 제30권1호
    • /
    • pp.7-13
    • /
    • 2019
  • Purpose: To compare the dosimetrical and radiobiological parameters among various volumetric modulated arc therapy (VMAT) techniques using restricted and continuous arc beams for left-sided breast cancer. Materials and Methods: Ten patients with left-sided breast cancer without regional nodes were retrospectively selected and prescribed the dose of 42.6 Gy in 16 fractions on the planning target volume (PTV). For each patient, three plans were generated using the $Eclipse^{TM}$ system (Varian Medical System, Palo Alto, CA) with one partial arc 1pVMAT, two partial arcs 2pVMAT, and two tangential arcs 2tVMAT. All plans were calculated through anisotropic analytic algorithm and photon optimizer with 6 MV photon beam of $VitalBEAM^{TM}$. The same dose objectives for each plan were used to achieve a fair comparison during optimization. Results: For PTV, dosimetrical parameters such as Homogeneity index, conformity index, and conformal number were superior in 2pVMAT than those in both techniques. $V_{95%}$, which indicates PTV coverage, was 91.86%, 96.60%, and 96.65% for 1pVMAT, 2pVMAT, and 2tVMAT, respectively. In most organs at risk (OARs), 2pVMAT significantly reduced the delivered doses compared with the other techniques, excluding the doses to contralateral lung. For the analysis of radiobiological parameters, a significant difference in normal tissue complication probability was observed in ipsilateral lung while no difference was observed in the other OARs. Conclusions: Our study showed that 2pVMAT had better plan quality and normal tissue sparing than 1pVMAT and 2tVMAT but not for all parameters. Therefore, 2pVMAT could be considered the priority choice for the treatment planning for left breast cancer.

해수 2단 공급에 따른 해수식 기화기(ORV)의 LNG 기화 특성 연구 (Study on the LNG Vaporization Characteristics of Open Rack Vaporizer(ORV) with Two-way Seawater Supplying System)

  • 김남국;윤상국
    • 한국가스학회지
    • /
    • 제23권1호
    • /
    • pp.41-46
    • /
    • 2019
  • LNG는 주된 기화기인 해수를 이용하는 해수식 기화기를 이용하여 가스 상태로 소비자에 공급되고 있다. 그러나 겨울철 해수 온도가 $5^{\circ}C$이하로 저하되면 수중 연소식 기화기를 사용하게 되며 이 때 막대한 LNG 기화 소요 비용이 발생하게 된다. 이를 절감하기 위하여 현재의 해수식 기화기의 1단 해수공급을 2단으로 공급하는 공정을 고안하여 그 효과를 분석하였다. 해석 결과, 6m 전열관의 외부에 해수를 2단으로 3m씩 가열할 때 온도가 $1.8^{\circ}C$가 저하되어 해수 온도 $2.5^{\circ}C$까지도 LNG의 기화온도를 $0^{\circ}C$이상으로 배출할 수 있는 것으로 해석되었다. 인천 생산기지에 이 공정이 적용된다면 연간 동계 운전비용 절감량은 LNG 11,770 Ton, 절감액은 117.6억 원으로 분석되었다. LNG를 전량 수입하는 국내 여건에서는 해수 2단 공급 공정을 적용한다면 막대한 에너지와 비용을 절감할 수 있는 매우 효과적인 공정이 될 수 있음을 알 수 있다.

X선에 노출된 보리의 생장과 엽록소 측정 (Measurement of Growth and Chlorophyl in Barley Exposed by X-ray)

  • 이원정;이모권;이중록;김하늘;유세종;이배원;정순철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.253-260
    • /
    • 2021
  • The purpose of this study is to measure of growth and chlorophyl in barley exposed by X-ray. Barley seed was soaked 24h duration in water, then was classified into two group; pre-seed germination group (Pre-G) or post-seed germination group (Post-G). Also, divided as control subgroup and experimental subgroup(10Gy, 20Gy, 30Gy) in each group. Experimental subgroups were exposed by X-ray using linear accelerator (Clinac IS, VERIAN, USA). Expose condition was 6 MV X-ray, SSD 100 cm, 18×10 cm, 600 MU/min. Length was measured every day for 10 days and 10th day for weight. Chlorophyl was analyzed using spectrophotometer(uv-1800, shimadzu, japan) in l0th day. Data analysis was performed using SPSS ver 22.0(Chicago, IL, USA), ANOVA test (Dunnett_T3) between control subgroup and experimental subgroup in group and Independent T-test between Pre-G and Post-G in subgroup. In Pre-G, length of barley was significantly difference between control and 30Gy in 4th day (4.3 vs. 1.5, p= 0.011). Length of 30Gy was statistical difference with control(10th day; 14.4 vs. 6.3, p < 0.01), and was not in 10Gy or 20Gy in all day. In experimental subgroup, length was shorter as increasing radiation dose. In Post-G, length of barley was not difference statistically between control and experimental subgroup in first day, but more difference between two subgroup with increasing duration after exposing. Length of experimental subgroup was shorter significantly compared with control in 10th day, and no significant difference between experimental subgroup. Density of chlorophyl was increasing with increasing radiation dose in Pre-G and Post-G. Chlorophyl density of control was lower than 30Gy; 0.26ppm in Pre-G, 0.29ppm in Post-G). Growth and chlorophyl of barley was effected by X-ray. It is expected to be used as basic data for future radiobiological research.

Monte Carlo Algorithm-Based Dosimetric Comparison between Commissioning Beam Data across Two Elekta Linear Accelerators with AgilityTM MLC System

  • Geum Bong Yu;Chang Heon Choi;Jung-in Kim;Jin Dong Cho;Euntaek Yoon;Hyung Jin Choun;Jihye Choi;Soyeon Kim;Yongsik Kim;Do Hoon Oh;Hwajung Lee;Lee Yoo;Minsoo Chun
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.150-157
    • /
    • 2022
  • Purpose: Elekta synergy® was commissioned in the Seoul National University Veterinary Medical Teaching Hospital. Recently, Chung-Ang University Gwang Myeong Hospital commissioned Elekta Versa HDTM. The beam characteristics of both machines are similar because of the same AgilityTM MLC Model. We compared measured beam data calculated using the Elekta treatment planning system, Monaco®, for each institute. Methods: Beam of the commissioning Elekta linear accelerator were measured in two independent institutes. After installing the beam model based on the measured beam data into the Monaco®, Monte Carlo (MC) simulation data were generated, mimicking the beam data in a virtual water phantom. Measured beam data were compared with the calculated data, and their similarity was quantitatively evaluated by the gamma analysis. Results: We compared the percent depth dose (PDD) and off-axis profiles of 6 MV photon and 6 MeV electron beams with MC calculation. With a 3%/3 mm gamma criterion, the photon PDD and profiles showed 100% gamma passing rates except for one inplane profile at 10 cm depth from VMTH. Gamma analysis of the measured photon beam off-axis profiles between the two institutes showed 100% agreement. The electron beams also indicated 100% agreement in PDD distributions. However, the gamma passing rates of the off-axis profiles were 91%-100% with a 3%/3 mm gamma criterion. Conclusions: The beam and their comparison with MC calculation for each institute showed good performance. Although the measuring tools were orthogonal, no significant difference was found.

Feasibility of a Linear Diode Array Detector for Commissioning of a Radiotherapy Planning System

  • Seung Mo Hong;Uiseob Lee;Sung-woo Kim;Youngmoon Goh;Min-Jae Park;Chiyoung Jeong;Jungwon Kwak;Byungchul Cho
    • 한국의학물리학회지:의학물리
    • /
    • 제34권1호
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: Although ionization chambers are widely used to measure beam commissioning data, point-by-point measurements of all the profiles with various field size and depths are time-consuming tasks. As an alternative, we investigated the feasibility of a linear diode array for commissioning a treatment planning system. Methods: The beam data of a Varian TrueBeam® radiotherapy system at 6 and 10 MV with/without a flattening filter were measured for commissioning of an Eclipse Analytical Anisotropic Algorithm (AAA) ver.15.6. All of the necessary beam data were measured using an IBA CC13 ionization chamber and validated against Varian "Golden Beam" data. After validation, the measured CC13 profiles were used for commissioning the Eclipse AAA (AAACC13). In addition, an IBA LDA-99SC linear diode array detector was used to measure all of the beam profiles and for commissioning a separate model (AAALDA99). Finally, the AAACC13 and AAALDA99 dose calculations for each of the 10 clinical plans were compared. Results: The agreement of the CC13 profiles with the Varian Golden Beam data was confirmed within 1% except in the penumbral region, where ≤2% of a discrepancy related to machine-specific jaw calibration was observed. Since the volume was larger for the CC13 chamber than for the LDA-99SC chamber, the penumbra widths were larger in the CC13 profiles, resulting in ≤5% differences. However, after beam modeling, the penumbral widths agreed within 0.1 mm. Finally the AAALDA99 and AAACC13 dose distributions agreed within 1% for all voxels inside the body for the 10 clinical plans. Conclusions: In conclusion, the LDA-99SC diode array detector was found to be accurate and efficient for measuring photon beam profiles to commission treatment planning systems.

K562 세포주에서 Genistein에 의해 억제되는 Radiation-induced Apoptosis의 조절 유전자 (Smad6 Gene and Suppression of Radiation-Induced Apoptosis by Genistein in K562 Cells)

  • 정수진;진영희;유여진;도창호;정민호;허기영;배혜란;양광모;문창우;오신근;허원주;이형식
    • Radiation Oncology Journal
    • /
    • 제19권3호
    • /
    • pp.245-251
    • /
    • 2001
  • 목적 : K562 세포를 대상으로 PTK inhibitor (herbimycinA와 genistein)에 의한 방사선 유도 apoptosis의 변화에 따른 관련 유전자를 탐색하고자 하였다. 대상 및 방법 : K562 세포는 $2\times10^5\;cells/mL$의 비율로 준비하여 대수증식기로 성장한 세포를 각각의 실험조건에 따라 처리하여 사용하였다. 방사선 조사는 6-MV X-Ray 10 Gy (Clinac 1800C, Varian, USA)를 $200\~300\;cGy/min$의 선량율로 상온에서 일정하게 조사하였다. Herbimycin A (HMA, Calbiochem, UK)와 genistein (Calbiochem, UK)은 dimethylsulfoxide (DMSO, Sigma, UK)에 녹여서 각각 1 mM과 10 mM의 농축용액으로 조제한 각각 250 nM과 $25\;{\mu}M$의 최종농도로 처리하였다. 내성 변화의 조절에 관여하는 유전자를 찾고자 PCR-select cDNA subtractive hybridization을 실시하여 128개의 차별 발현되는 clones을 재선별하였다. DNA sequencing을 통하여 염기서열을 분석하였으며, GenBank database를 이용하여 이미 밝혀진 유전자들과의 상동성을 비교하였다. 상동성을 갖는 clone을 확인하여 이를 probe로 사용하여 방사선 단독조사한 실험군과 방사선과 HMA 또는 genistein을 동시 처리한 실험군들간의 mRNA 발현의 차이를 Northern hybridization을 통하여 확인하였다. 결과 : homo sapiens Smad6 유전자와 $95\%$의 상동성을 갖는 clone을 확인하였다. 이를 probe로 사용하여 방사선 단독 조사한 실험군과 방사선과 HMA 또는 genistein을 동시 처리한 실험군들간의 mRNA 발현의 차이를 비교 분석한 결과, 방사선과 genistein을 동시 처리한 실험군의 mRNA 발현이 방사선 단독 조사한 실험군과 방사선과 HMA를 처리한 실험군들에 비하여 현저히 높았다. 결론 : Smad6와 방사선에 의해 유도되는 apoptosis의 억제에 관한 연관성을 보고한 문헌은 없으나, Smad6가 일부세포에서 apoptosis를 억제한다는 보고들과, 본 연구에서 관찰한 genistein에 의한 방사선에 의해 유도되는 apoptosis의 억제에서 그 발현이 두드러지게 증가한 점 등을 미루어 보아 방사선에 의하여 유도된 apoptosis의 억제 및 방사선 내성의 조절에도 관여할 것으로 생각된다.

  • PDF

하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화 (Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method)

  • 박석원;안용찬;허승재;전호경;강원기;김대용;임도훈;노영주;이정은
    • Radiation Oncology Journal
    • /
    • 제18권3호
    • /
    • pp.194-199
    • /
    • 2000
  • 목적 :직장암의 림프액 배액의 주된 경로는 종양의 위치가 항문환에 근접한 경우를 제외하고는 근위부플 향하므로 수술 후 방사선치료의 조사영역을 결정함에 있어서 전통적인 방법에 따를 경우 하부 골반강과 회음부에 불필요한 방사선조사를 하게될 수 있다. 본 연구는 하전방 절제술을 시행받은 직장암 환자에서 방사선치료 조사영역의 하연을 전통적인 방법에 의하지 않고 수술 문합부로부터 2 cm 내지 3 cm 하방으로 환자 개별적으로 결정하는 경우에 있어서 치료 실패의 양상이 어떠한 영향을 받는가를 알아보기 위하여 수행하였다. 대상 및 방법 : 1994년 9월부터 1998년 5월까지 성균관의대 삼성서울병원에서 근치적 하전방 절제술과 수술 후 방사선치료를 시행한 Modified Astler-Coiler (MAC) 병기 B2에서 C3까지인 88명의 직장암 환자를 대상으로 하였다. 남녀 환자 수는 각각 설명씩이었으며 연령의 중앙값은 57세(32-81세)였다. 2명의 환자를 제외한 모든 환자에서 저용량의 5-fluorouracil을 포함한 항암 화학요법을 병용하였으며, 수술 후 방사선치료는 6, 10, 15 MV X-ray를 이용하여 후전-좌우 대향의 3문 조사법으로 전골반부에 45 Gy와 종양 병소부위에 6 Gy를 5.5주간 걸쳐서 조사하였다. 연구 기간 초기의 16명의 환자에서는 전통적인 방사선조사영역 결정법을 적용하여 폐색공 하단, 또는 수술 문합부의 2 cm 내지 3 cm 하방 중에서 보다 낮은 쪽을 방사선조사영역의 하연으로 정하였으며, 나머지 72명의 환자에서는 수술 문합부에서 2 cm 내지 3 cm 하방에서 조사영역 하연을 개별적으로 결정하였는데 이와 같은 개별화된 방사선 치료 조사영역의 결정으로 55명(76$\%$)의 환자에서 방사선치료 조사영역 부피를 감소시킬 수 있었다. 이 두 군에 대해 생존율, 국소 종양 억제율, 무병생존율을 조사하여 비교하였고 예후 인자의 유의성을 조사하였다. 결과 : 추적 관찰 기간은 7개월부터 58개월이었으며, 중앙 추적기간은 27개월이었다. MAC 병기로 구분 시 B2가 32명(36$\%$), B3가 2명($2\%$), Cl이 2명($2\%$), C2가 50명($57\%$), C3가 2명($2\%$) 이었다. 전체 환자의 2년과 4년 생존율은 각각 $94\%$$68\%$였으며, 2년과 4년 무병 생존율은 각각 $86\%$$58\%$였다. 첫 치료 실패로서 국소 재발이 4명, 원격전이가 14명, 그리고 국소 재발과 원격전이가 동시에 있는 경우가 1명이었다. 방사선치료 조사영역의 하연 결정을 전통적인 방법을 적용한 군과 수술 문합부의 위치에 따라서 환자 개별적으로 결정한 군을 비교하여 볼 때 국소 종양 억제율과 무병 생존율은 각각 유의한 통계적인 차이를 보이지 않았다(p=42, p=68). 종양 색전자의 존재는 생존율, 국소 종양 억제율, 무병 생존율에 각각 영향을 미치는 유의한 위험인자로 관찰되었다. 결론 : 하전방 절제술을 시행받은 직장암 환자들의 수술 후 방사선치료 조사영역의 하연을 결정함에 있어서 각환자들의 병소 위치에 따라 개별적으로 결정하는 방법은 전통적인 하연 결정방법에 비하여 국소 종양 억제율과 무병생존율에 있어서 동등한 결과를 얻을 수 있었으며, 방사선치료 조사영역의 부피를 줄여 줌으로써 불필요한 방사선치료 부작용과 후유증의 감소를 얻을 수 있을 것으로 판단된다.

  • PDF

침윤성 유방암에서 유방보존수술 후 방사선치료 및 항암화학 병용치료의 성적 및 위험인자 분석 (Radiation Therapy and Chemotherapy after Breast Conserving Surgery for Invasive Breast Cancer: An Intermediate Result)

  • 이석호;최진호;이영돈;박흥규;김현영;박세훈;이규찬
    • Radiation Oncology Journal
    • /
    • 제25권1호
    • /
    • pp.16-25
    • /
    • 2007
  • 목 적: 조기병기 유방암에서 유방보존수술 후 방사선치료 및 항암화학 병용요법이 보편화되면서 표준적치료로 인정되고 있다. 유방보존치료를 받은 환자들을 대상으로 수년 이내의 재발양상, 생존율 및 그에 관련되는 위험인자를 알아보기 위하여 본 연구를 시행하였다. 대상 및 방법: 1999년 1월부터 2003년 12월까지 관내상피암을 제외한 침윤성 유방암으로 유방보존수술 후 방사선 치료를 시행 받은 129명의 환자를 대상으로 후향적 분석을 시행하였다. 전체 환자의 중앙연령은 45세($27{\sim}76$세)이었고, 연령대로는 40대가 62명(48.1%)으로 가장 많았다. TNM 병기는 I기 65명(50.4%), IIa기 41명(31.7%), IIb기 13명(10.1%), IIIa기 9명(7.0%), IIIc기 1명(0.7%)이었다. 액와림프절 전이가 있었던 환자는 32명(24.8%)이었다. 수술은 사분원절제술이 115명(89.1%), 종괴절제술이 14명(10.9%)에서 시행되었다. 액와림프절곽청술은 120명(93%)에서 시행되었다. 방사선치료는 동측 전체 유방에 6 MV X-선으로 50.4 Gy를 28회에 걸쳐 시행하고, 원발병소에 $9{\sim}16\;Gy$를 추가하였다. 쇄골상 림프절 방사선치료를 받은 환자는 30명(23.3 %)이었다. 항암화학요법은 대부분 CMF요법으로 $4{\sim}6$회가 시행되었다. 전체환자의 중앙 추적관찰기간은 50개월($17{\sim}93$개월)이었다. 결 과: 5년 생존율은 96.9%, 5년 무병 생존율은 93.7%이었다. 병기별 5년 생존율은 I기 97.1%, IIa기 100%, IIb기 84.6%, III기 100%이었고, 5년 무병생존율은 I기 96.8%, IIa기 92.7%, IIb기 76.9%, III기 100%이었다. 유방내 국소재발은 2명(1.6%)에서 발생하였고, 동측 쇄골상 림프절 재발이 1명(0.8%), 원격전이는 5명(3.9%)에서 발생하였다. 국소재발의 평균 기간은 32.5개월이었다. 원격전이는 평균 21개월에 발생하였고, 골전이 3명, 간전이 1명, 전신전이 1명이었다. 이 중 2명이 각각 17개월, 25개월에 사망하였다. 예후인자 분석에서 병기만이 단변량 분석에서 유의하였다. 본 연구에는 III기 환자가 10명 포함되었는데, 원발병소의 크기는 모두 3 cm 이하였으며, 액와림프절 전이가 4개 이상인 경우였다. 이들은 모두 액와부 및 쇄골상부 방사선치료를 받았으며, 추적기간 동안 국소재발이나 원격전이 소견은 발견되지 않았다. 부작용으로는 10명(7.8%)에서 무증상방사선폐렴이 있었으며 증상을 동반한 방사선 폐렴이 1명(0.8%) 그리고 상지부종이 10명(7.8%)에서 있었다. 결 론: 추적기간이 짧았지만 조기 병기 침윤성 유방암에서 유방보존수술 후 방사선치료 및 항암화학요법을 시행하여 높은 국소 제어율과 생존율을 얻었으며, 향후 장기적인 추적관찰이 필요할 것으로 사료된다. 유방내 국소 재발은 수년 내에는 적었으며, 원격전이는 상대적으로 일찍 발생함을 알 수 있었다. 또한, 원발병소의 크기가 3 cm 이하로 작고, 액와림프절 전이가 4개 이상인 환자를 대상으로 유방보존치료 적용가능 여부에 대한 장기적 추적관찰 및 추가적 분석이 필요할 것으로 사료된다.

진행된 후두암 환자에서 후두전절제술에 의한 척수선량 변화 (Influence of Total Laryngectomy on Spinal Cord Dose in Advanced Laryngeal Cancers)

  • 김재철;김성환;박인규
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.167-173
    • /
    • 1996
  • 목적 ; 진행된 후두암 환자에서 후두전절제술 후 경부에 대해 방사선치료를 할 때 기관루 부위의 선량분포 양상 및 기관루에 의한 척수선량의 변화를 알아보고자 하였다. 방법 : 환자의 전산화 단층촬영상을 기준으로 하여 기관루가 있는 팬톰과 기관루가 없는 팬톰을 각각 제작하고 열형광선량계 및 필름선량계를 이용하여 기관루가 있는 팬톰에서의 척수선량과 기관루가 없는 팬톰에서의 척수선량을 측정 비교하였다. 후두전절제술을 시행한 진행된 후두암 환자 12예를 대상으로 수술 전과 수술 후에 각각 전산화 치료계획을 실시하여 척수선량을 비교하였다. 또한 팬톰에 대해서 필름선량계를 이용하여 기관루 부위의 선량분포양상을 폭정하였다. 결과 : 6MV X-선, $10\times20cm$의 조사야로 조사한 팬톰에서 열형광선량계를 사용하여 측정한 평균 척수선량은 직경 1.2cm, 깊이 3cm의 기관루가 있는 경우 $86.4\%$, 기관루가 없는 경우 $80.1\%$로 그 차이는 $6.3\%$였다. 팬톰에서 필름선량계로 측정한 평균 척수선량은 기관루가 있는 경우 $84.7\%$, 기관루가 없는 경우 $79.0\%$로 그 차이는 $5.7\%$였다. 팬톰에서 전산화치료계획으로 계산한 척수선량은 기관루가 있는 경우 $84.0\%$, 기관루가 없는 경우 $78.0\%$로 그 차이는 $6.0\%$였다. 환자에서 계산한 척수선량은 기관루가 있는 경우 $83.1\%$, 기관루가 엾는 경우 $76.9\%$로 그 차이는 $6.2\%$였다. 필름선량계로 측정한 기관루 측벽과 후벽의 선량은 낮은 양상을 보였다 (최대선량 깊이 = 12 mm). 결론 : 팬톰 및 환자에서의 기관루가 척수선량에 미치는 영향은 기관루의 크기나 형태에 따라 $6\%$ 내외의 선량 증가였고, 기관루 측벽 및 후벽의 선량은 낮은 양상을 보였다. 따라서 후두전절제술 후 하경부에 대해 방사선치료를 시행할 경우 부작용 방지를 위해 산란괴를 사용하여 척수 선량을 보정해 주고 기관루의 선량 증가를 위해 근접치료에 의한 추가조사 등의 적절한 조치가 필요할 것으로 생각된다.

  • PDF