• 제목/요약/키워드: 5S Method

검색결과 18,162건 처리시간 0.042초

비교 실험을 통한 PM-2.5 질량농도의 측정오차 분석 (Analysis of Measurement Error for PM-2.5 Mass Concentration by Inter-Comparison Study)

  • 정창훈;박진희;황승만
    • 환경영향평가
    • /
    • 제19권4호
    • /
    • pp.431-441
    • /
    • 2010
  • In this study, inter-comparison for PM-2.5 was undertaken. The PM-2.5 mass concentrations using the gravimetric and beta-attenuation methods were compared during the winter in 2007. Two different types of conventional filter-based measurements (Cyclone type and Impactor type) were also collocated and the measurement data was compared with each other. As a result, continuous PM-2.5 data using beta attenuation method show a comparable mass concentration with gravimetric measurement when the inlet of beta-gauge sampler is heated. The results also showed that the cyclone type shows a little high PM-2.5 concentration than Impactor type. In all the sampling cases, the correlations between measurement methods are high. Subsequently, this study suggests that highly correlated relationship between PM-2.5 measurement instruments can be obtained through the inter-comparison results based on filterb-ased gravimetric method and more intensive measurement and theoretical studies are needed in order to clarify the measurement errors for different sampler types.

Equivalent stiffness method for nonlinear analysis of stay cables

  • Xia, G.Y.;Cai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제39권5호
    • /
    • pp.661-667
    • /
    • 2011
  • In the famous equivalent elasticity modulus method proposed by Ernst for the geometrical nonlinear analysis of stay cables, the cable shape was assumed as a parabolic curve, and only a part of the gravity load normal to the chord was taken into account with the other part of gravity load parallel to the chord being ignored. Using the actual catenary curve and considering the entire gravity load of stay cables, the present study has derived the equivalent stiffness method to analyze the sag effect of stay cables in cable-stayed bridges. The derived equivalent stiffness can be degenerated into Ernst's equivalent elasticity modulus method with some approximations. Therefore, the Ernst's method is a special and approximate formulation of the present method. The derived equivalent stiffness provides a theoretical explanation for the famous Ernst's formula.

Nonlocal buckling characteristics of heterogeneous plates subjected to various loadings

  • Ebrahimi, Farzad;Babaei, Ramin;Shaghaghi, Gholam Reza
    • Advances in aircraft and spacecraft science
    • /
    • 제5권5호
    • /
    • pp.515-531
    • /
    • 2018
  • In this manuscript, buckling response of the functionally graded material (FGM) nanoplate is investigated. Two opposite edges of nanoplate is under linear and nonlinear varying normal stresses. The small-scale effect is considered by Eringen's nonlocal theory. Governing equation are derived by nonlocal theory and Hamilton's principle. Navier's method is used to solve governing equation in simply boundary conditions. The obtained results exactly match the available results in the literature. The results of this research show the important role of nonlocal effect in buckling and stability behavior of nanoplates. In order to study the FG-index effect and different loading condition effects on buckling of rectangular nanoplate, Navier's method is applied and results are presented in various figures and tables.

HMX와 RDX의 열적 특성에 미치는 입자 크기의 영향 (Effect of Particle Size on Thermal Property of RDX and HMX)

  • 김승희
    • 공업화학
    • /
    • 제23권3호
    • /
    • pp.352-357
    • /
    • 2012
  • 1,3,5-trinitro-1,3,5-triazacylohexane (RDX)와 octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX)의 입자크기에 대한 열적 특성을 알아보기 위해서 DSC (Differential Scanning Calorimetry)와 TGA (Thermo-Gravimetric Analysis)를 사용하였다. 활성화 에너지와 빈도인자는 Kissinger 방법과 Vyazovkin 방법으로 계산하였다. DSC를 이용할 경우 RDX의 경우에는 고에너지 분자화약의 높은 분해열에 의하여 입자크기에 따른 활성화에너지의 경향성이 없었으나, TGA를 이용할 경우 입자크기가 클수록 활성화에너지가 커짐을 알 수 있었다. 그러나 HMX의 경우에는 DSC와 TGA의 방법 모두 입자 크기에 따라 활성화 에너지가 커지는 경향성을 보였다. 또한, Vyazovkin 방법을 이용하여 RDX와 HMX의 분해정도에 따른 활성화 에너지의 변화로 분해반응의 메커니즘을 이해할 수 있었다.

High Accuracy Classification Methods for Multi-Temporal Images

  • Hong, Sun Pyo;Jeon, Dong Keun
    • The Journal of the Acoustical Society of Korea
    • /
    • 제16권1E호
    • /
    • pp.3-8
    • /
    • 1997
  • Three new classification methods for multi temporal images are proposed. They are named as a likelihood addition method, a likelihood majority method and a Dempster-Shafer's rule method. Basic strategies using these methods are to calculate likelihoods for each temporal data and to combine obtained likelihoods for final classification. These three methods use different combining algorithms. From classification experiments, following results were obtained. The method based on Dempster-Shafer's rule of combination showed about 12% improvement of classification accuracies compared to a conventional method. This method needed about 16% more processing times than that of a conventional method. The other two proposed method showed 1% to 5% increase of classification accuracies. However processing times of these two proposed method showed 1% to 5% increase of classification accuracies. However processing times of these two methods are almost the same with that of a conventional method. Among the newly proposed three methods, the Dempster-Shafer's rule method showed the highest classification accuracies with more processing time than those of other methods.

  • PDF

Colombini 방법에 의한 요추부 추간판 크기 추정에 관한 연구 (A Study of Estimation of Lumbar Intervertebral Disc Size by Colombini's Method)

  • 김종순
    • The Journal of Korean Physical Therapy
    • /
    • 제19권1호
    • /
    • pp.23-31
    • /
    • 2007
  • Purpose: As a preliminary study, the purpose of this study was to examine the indirect estimation of the lumbar intervertebral disc size by two anthropometric methods, in order to compare these indirect methods with the direct analysis by radiological imaging. Methods: The wrist, elbow, knee, and ankle joint (both right and left) diameters were measured in 52 volunteers, and then intervertebral disc size was calculated using two anthropometric methods (Colombini and modified Colombini). The data were analysed with independent t-test to assess clinical usefulness. Results: When using right and left joint diameter, there was no significant difference in the estimation value of the L4-5 and L5-S1 intervetebral disc sizes. However, the study has shown that male subjects have significantly larger L4-5 and L5-S1 intervertebral disc sizes, compared with those of female subjects. In addition, disc sizes calculated by Colombini's formula were significantly larger than modified Colombini's formula. Conclusion: The indirect estimation of the intervertebral disc size by anthropometric method can be considered as a clinically useful method. However, further study should be conducted to compare anthropometric values with other radiological imaging.

  • PDF

한국재래닭 (오계) 원시생식세포의 완만동결과 급속동결의 비교 (Comparison of Vitrification and Slow Freezing for the Cryopreservation of Chicken Primordial Germ Cell (Ogye))

  • 김성우;고응규;변미정;도윤정;한재용;김동훈;성환후;김현
    • Journal of Animal Science and Technology
    • /
    • 제55권5호
    • /
    • pp.417-425
    • /
    • 2013
  • 동결 닭 PGCs의 생식계열 키메라를 이용한 생체에의 복원을 실용화 하기 위해서는, 닭 PGCs의 동결보존기술의 향상에 의해 동결 및 융해 후의 많은 생존세포를 확보 하는 것과, 생식계열 키메라의 제작효율을 높이는 것이 반드시 필요하다. 닭 PGCs는 배양 5.5일령의 닭 원시생식선으로부터 채취하고, ACS 방법에 의해서 순수 닭 PGCs를 분리했다. 닭 PGCs의 동결보존실험결과 다음의 4종류의 동결방법을 각각 비교 검토했다. 1. 플라스틱 스트로에 의한 완만동결법 (SF), 동결보호물질은 2M 에틸렌 글리콜 (EG), 2. 스트로에 의한 급속동결법 (RF), 8M EG + 7% PVP, 3. 동결용 Cryotube에 의한 SF, 2M EG, 4. 튜브에 의한 SF, 10% DMSO. 동결 및 융해 후의 PGCs의 생존율은 각각 76.4%, 70.6%, 80.5%, 78.1%로 관찰되었다.

유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가 (Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography)

  • 정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

Frontal Analysis와 Pulse Input Method를 이용한 Loxoprofen의 등온흡착식 결정 (Determination of Loxoprofen Adsorption Isotherms by Frontal Analysis and Pulse Input Method)

  • 이은;박준섭;김인호
    • KSBB Journal
    • /
    • 제21권5호
    • /
    • pp.371-375
    • /
    • 2006
  • 본 실험의 목적은 frontal analysis(FA)와 pluse input method(PIM) 방법으로 흡착분리공정에 있어서 중요한 전 단계의 하나인 등온흡착식을 결정하는데 있다. FA를 수행하기에 앞서 대상물질이었던 loxoprofen의 용해도를 측정하여 hexane/ethanol=95/5일 때 시료의 농도를 $0.2{\sim}3mg/ml$로 결정하고, pH조정을 위한 acetic acid는 0.5%로 결정하였다. 이동상의 주성분인 hexane의 조성이 증가함에 따라 용해도는 감소하였지만 분리도는 증가하는 경향을 확인하였다. 이런 용해도와 분리도 사이의 trade-off 또한 흡착분리과정에서의 조작변수가 될 수 있음을 의미한다. FA로 구한 이성분계 등온흡착식은 $$C_{S,re}=\frac{5.282C_{M,re}}{1+0.1412C_{M,re}+0.2139C_{M,ex}}$$, $$C_{S,ex}=\frac{6.413C_{M,ex}}{1+0.2139C_{M,ex}+0.1412C_{M,re}}$$로 결정하였고, PIM으로 구한 이성분계 등온흡착식은 $$C_{S,re}=\frac{5.245C_{M,re}}{1+0.1667C_{M,re}+0.2054C_{M,ex}}$$, $$C_{S,ex}=\frac{6.061C_{M,ex}}{1+0.2054C_{M,ex}+0.1667C_{M,re}}$$로 결정 하였다.

청·장년층의 조절력에 관한 고찰 (A Study for Young and Middle Age People of Accommodation)

  • 김정희
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.129-136
    • /
    • 1998
  • 19세에서 40세까지의 청 장년층 242안(121명)을 대상으로 Spherical Add 법과 Cross cylinder lens법을 이용하여 조절력 검사를 실시하여 다음과 같은 결과를 얻었다. Spherical Add법을 사용하여 조절력을 측정한 결과 20대의 조절력의 범위는 9~13Diopter로 나타났고, 30대의 조절력의 범위는 6~8.5Diopter로 나타났다. 20대는 왕성한 조절력을 지니고 있음을 알 수 있었고, 30대 이상은 조절력이 25세 이전과 비교해서 감소함을 알 수 있었다. Cross cylinder lens법을 이용하여 조절력을 측정한 결과 20대의 평균조절력의 범위는 6.13~10.13Diopter, 30대의 평균조력의 범위는 5.75~8.75Diopter, 40대의 평균조절력의 범위는 4.38~7.25Diopter로 나타난다. 즉 조절력은 나이가 많아짐에 따라 감소함을 알 수 있었고 남녀 모두 cross cylinder lens의 붉은점을 수평방향으로 위치시킬 때의 조절력이 cross cylinder lens의 붉은점을 수직방향으로 위치시킬 때의 조절력보다 큰 것으로 나타났다. Spherical Add법과 Cross cylinder lens 법에 의해 측정한 조절력의 분포를 살펴보면 대부분 S.A 법을 이용하여 측정한 조절력이 Cr.c 법을 이용하여 측정한 조절력보다 큰 것으로 나타났다.

  • PDF