• Title/Summary/Keyword: 5S Method

Search Result 18,277, Processing Time 0.057 seconds

Performance Comparison Between the Envelope Peak Detection Method and the HMM Based Method for Heart Sound Segmentation

  • Jang, Hyun-Baek;Chung, Young-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2E
    • /
    • pp.72-78
    • /
    • 2009
  • Heart sound segmentation into its components, S1, systole, S2 and diastole is the first step of analysis and the most important part in the automatic diagnosis of heart sounds. Conventionally, the Shannon energy envelope peak detection method has been popularly used due to its superior performance in locating S1 and S2. Recently, the HMM has been shown to be quite suitable in modeling the heart sound signal and its use in segmenting the heart sound signal has been suggested with some success. In this paper, we compared the two methods for heart sound segmentation using a common database. Experimental tests carried out on the 4 different types of heart sound signals showed that the segmentation accuracy relative to the manual segmentation was 97.4% in the HMM based method which was larger than 91.5% in the peak detection method.

On the parallel merging algorithm (Heap 병합 병렬 알고리즘)

  • 민용식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.5-13
    • /
    • 1993
  • The purpose of this paper is to suggest and analyze the parallel algorithm for merging two heaps, on SIMD-SM-R parallel computer. In order to create the parallel algorithm for merging two heaps, we have classified two subproblems. For the first method, to select node p as a LEVEL-FIND function, Wyllie(19) suggests the method with time complexity O(log n) while this thesis has O(log(n/k)). For the second method, to merge two subheap, our algorithm has O(log(n/k)*log(n)) using max(2**(i-1), 「(m+1)/4」)'s processors while Dekel and Sahni(4)'s method and Hong's method(18) have O(log m). Also our parallel algorithm's EPU is close to 1 and so has an optimal speed-up ratio.

  • PDF

Elastic Stiffness Analysis of Leaf Type Holddown Spring Assemblies (판형홀드다운 스프링 집합체의 탄성 강성도 해석)

  • Lim, Hyun-Tae;Kim, Jae-Won;Song, Kee-Nam
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.760-766
    • /
    • 1995
  • A general method is proposed for elastic stiffness analysis of the leaf type holddown springs using only the geometric data and Young's modulus of the springs. In this method, an engineering beam theory and Castigliano's theory are applied to elastic stiff analysis of the leaf type holddown springs. To show reliability and effectiveness of this method, the elastic stiffness from the proposed method is compared with test result and from the comparison, the unposed method has been proven to be effective for estimating the elastic stiffness of the leaf springs.

  • PDF

EVALUATION OF TECHNIQUES FOR ESTIMATING MILK PRODUCTION BY SOWS 1. DEUTERIUM OXIDE DILUTION METHOD FOR ESTIMATING MILK INTAKE BY PIGLETS

  • Prawirodigdo, S.;King, R.H.;Dunkin, A.C.;Dove, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.2
    • /
    • pp.135-141
    • /
    • 1990
  • Two experiments were conducted to determine the validity of the deuterium oxide ($D_2O$) dilution method to estimate milk intake by pigs. A total of 39 piglets weaned from their dams 24 - 36 hours after birth and trained to drink from artificial nipples, were used for two experiments. Estimates of milk replacer consumption of individual piglets over 1, 3, 5 and 7 days were made by the $D_2O$ dilution method and by dissappearance. Milk intakes estimated by this $D_2O$ dilution method were significantly correlated ($R^2$ = 0.98-0.99) with milk intake measured by disappearance. The average difference between estimates by disappearance and estimates by the $D_2O$ dilution method were -1%, +0.5%, +0.5% and -2.1% for measurement period of 1, 3, 5 and 7 days respectively.

The Solar Atmospheric Transmittance Data for Peak Cooling Load Calculation using ETD Method (실효온도차법에 의한 최대열부하계산용 일사 대기투과율)

  • Kim, D.C.;Seo, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.316-322
    • /
    • 1992
  • A simplified TAC method was developed for the selection of solar atmospheric transmittance data fundamental to the calculation of design solar radiation for the peak cooling load calculation using ETD method. The summer and autumn solar atmospheric transmittance data of the 11 major cities in Korea were obtained. Based on the simplified TAC method, the atmospheric transmittance data were selected by the TAC 2.5% of July instead of the TAC 2.5% of June through September for summer and the TAC 5.0% of October instead of the TAC 2.5% of October and November for autumn. Results show that the atmospheric transmittance data at solar noon were in the range of 0.61-0.66 for summer and 0.78-0.82 for autumn except for Pusan and Incheon.

  • PDF

A Fast Multiplication Method for Elliptic Curves defined on small finite fields (작은 유한체 위에 정의된 타원곡선의 고속연산 방법)

  • 박영호;정수환
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.12 no.5
    • /
    • pp.45-51
    • /
    • 2002
  • As Koblitz curve, the Frobenius endomorphism is know to be useful in efficient implementation of multiplication on non-supersingular elliptic cures defined on small finite fields of characteristic two. In this paper a method using the extended Frobenius endomorphism to speed up scalar multiplication is introduced. It will be shown that the proposed method is more efficient than Muller's block method in [5] because the number of point addition for precomputation is small but on the other hand the expansion length is almost same.

Evaluation of Microwave Dielectric Properties in $(Pb_{0.5}Ca_{0.5})(Fe_{0.5}Ta_{0.5})O_3$ Ceramics by the Dielectric Mixing Rule (유전체 혼합 법칙을 이용한 $(Pb_{0.5}Ca_{0.5})(Fe_{0.5}Ta_{0.5})O_3$세라믹스의 마이크로파 유전특성 평가)

  • 박흥수;윤기현;김응수
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.240-246
    • /
    • 2000
  • The microwave dielectric properties of the complex perovskite (Pb0.5Ca0.5)(Fe0.5Ta0.5)O3 ceramics were investigated with the porosity and the dielectric mixing rule. Assuming that the specimens were mixtures of real dielectrics and pores, with 3-0 connectivity, the ionic polarizabilities modified by Maxwell's equation were more close to the theoretical values rather than those modified by Wiener's equation in porous specimens. The theoretical dielectirc loss were obtained with the infrared reflectivity spectra from 50 to 4000cm-1, which were calculated by Kramers-Kronig analysis and classical osciallator model. The relative tendency of dielectric loss calculated from the theoretical value and Maxwell's equation in the specimens with different porosities was in good agreement with the one by the post resonant method.

  • PDF

A Study on the Comparison of Injection Rate Measurement by the Bosch`s Method and the Zeuch`s Method (Bosch법과 Zeuch법에 의한 분사율 , 측정의 비교연구)

  • Ra, Jin-Hong;Kim, Jun-Hyo;An, Su-Gil
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.65-75
    • /
    • 1990
  • There have been many methods for measuring the injection rate of diesel engines, but the results of them are not always identical and the reason for the discordance is not clear. Besides, a single shot injection equipment has been used for the fuel spray and the combustion research of diesel engines, but the results of experiment using the equipment don't apply to a volleyed shot injection of real engines. This paper investigates the merits and faults of the Bosch's method and the Zeuch's method, at the same, this paper also compares the injection rates of single shot inject rates of single shot injection and a volleyed shot injected by the Bosch's method. the results are summarized as follows: (1) The measurement error of the Bosch's method is about $\pm$1%, therefore, its accuracy is reliable. (2) By the Bosch's method, as the speed and the load of fuel pump increase, the injection rate becomes higher, on the contrary, the injection period(ms) shortens as the speed increases and the load decreases. (3) In this experiment, the injection rate of a single shot injection is lower than that of a volleyed shot injection under the same conditions. (4) The bulk modulus of elasticity using the Zeuch's method increases in proportion to the back pressure. (5) The Zeuch's method is less accurate than the Bosch's method.

  • PDF

Scintillation Characteristics of CsI:X(X=Li+,K+,Rb+ Single Crystals (CsI:X(X=Li+,K+,Rb+단결정의 섬광특성)

  • Gang, Gap-Jung;Doh, Sih-Hong;Lee, Woo-Gyo;Oh, Moon-Young
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • CsI single crystals doped with lithium, potassium or rubidium were grown by using Czochralski method at Ar gas atmosphere. The energy resolutions of CsI(Li:0.2 mole%), CsI(K:0.5 mole%) and CsI(Rb:1.5 mole%) scintillators were 14.5%, 15.9% and 17.0% for $^{137}Cs$(0.662 MeV), respectively. The energy calibration curves of CsI(Li), CsI(K) and CsI(Rb) scintillators were linear for $\gamma$-ray energy. The time resolutions of CsI(Li:0.2 mole%), CsI(K:0.5 mole%) and CsI(Rb:1.5 mole%) scintillators measured by CFT(constant-fraction timing method) were 9.0 ns, 14.7 ns and 9.7 ns, respectively. The fluorescence decay times of CsI(Li:0.2 mole%) scintillator had a fast component and slow one of ${\tau}_1=41.2\;ns$ and ${\tau}_2=483\;ns$, respectively. The fluorescence decay times of CsI(K:0.5 mole%) scintillator were ${\tau}_1=47.2\;ns$ and ${\tau}_2=417\;ns$. And the fluorescence decay times of CsI(Rb:1.5 mole%) scintillator were ${\tau}_1=41.3\;ns$ and ${\tau}_2=553\;ns$. The phosphorescence decay times of CsI(Li:0.2 mole%), CsI(K:0.5 mole%) and CsI(Rb:1.5 mole%) scintillators were 0.51 s, 0.57 s and 0.56 s, respectively.

A Comparison of Multivariate R-Techniques in SAS, SPSS, Minitab and S-plus (SAS, SPSS, MINITAB, 5-PLUS에서 다변량 R-기법의 비교)

  • 최용석;문희정
    • The Korean Journal of Applied Statistics
    • /
    • v.17 no.1
    • /
    • pp.153-164
    • /
    • 2004
  • In this study, we compare multivariate R-techniques in the up-to-date versions of SAS, SPSS, Minitab and S-plus. The direct input method by typing in command is considered for SAS, while the menu-driven method is considered for SPSS, Minitab and S-plus. Comparison was made in terms of input data format, input option, charts and outputs.