• 제목/요약/키워드: 5D CAD

검색결과 277건 처리시간 0.029초

유닛모듈러 기반 도시형 생활주택의 BIM 모델링 프로세스 개발 연구 (The Study on the Developing Process of BIM Modeling for Urban-life-housing Based on Unit Modular)

  • 이창재;임석호
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.77-84
    • /
    • 2012
  • The current architectural design of unit modular has been based on 2D of CAD program, so unit modular character which needs unit information management, as a dried-member system, has no effect on design process. The purpose of this study is We have developed a suitable BIM design process, according to various works of construction, then tried to contribute to supply and activation of the urban-life-housing based on unit modular. The BIM modeling process based on unit modular has been in order of unit combination with preparing manual classification, and, it has been constructed, at construction site, from housing foundation to roof finish by Bottom-up method. At a manufacturing factory, it has been produced in order of 1) grouping materials and parts, 2) fabricating unit boxes, and 3) interference examination of unit boxes, and each order has been classified as housing structure, architecture, plumbing process separately. At a construction site, the fabrication has been done in order of, like as a real housing construction scenario, 1) RC foundation work 2) unit module job-site-fabrication work, 3) roof truss work, 4) plumbing and HVAC work, and 5) housing interior finish work. After modeling process, the interference examination on each work of construction has finally completed modeling. The Unit modular utilizing BIM modeling can make easy housing maintenance through systematic control with preparing manual of unit module information, and securing accurate and speedy construction information. And it will promote design credibility and create maximum effect of unit modular construction method, such as construction period reduction and upgrade of construction quality, etc., through the computer simulation as real as construction environment in cyber space, and with the interfering examination.

Effect of different veneering techniques on the fracture strength of metal and zirconia frameworks

  • Turk, Ayse Gozde;Ulusoy, Mubin;Yuce, Mert;Akin, Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권6호
    • /
    • pp.454-459
    • /
    • 2015
  • PURPOSE. To determine whether the fracture strengths and failure types differed between metal and zirconia frameworks veneered with pressable or layering ceramics. MATERIALS AND METHODS. A phantom molar tooth was prepared and duplicated in 40 cobalt-chromium abutments. Twenty metal (IPS d.SIGN 15, Ivoclar, Vivadent, Schaan, Liechtenstein) and 20 zirconia (IPS e.max ZirCAD, Ivoclar) frameworks were fabricated on the abutments. Each framework group was randomly divided into 2 subgroups according to the veneering material: pressable and layering ceramics (n=10). Forty molar crowns were fabricated, cemented onto the corresponding abutments and then thermocycled ($5-55^{\circ}C$, 10,000 cycles). A load was applied in a universal testing machine until a fracture occurred on the crowns. In addition, failure types were examined using a stereomicroscope. Fracture load data were analyzed using one-way ANOVA and Tukey HSD post-hoc tests at a significance level of 0.05. RESULTS. The highest strength value was seen in metal-pressable (MP) group, whereas zirconia-pressable (ZP) group exhibited the lowest one. Moreover, group MP showed significantly higher fracture loads than group ZP (P=.015) and zirconia-layering (ZL) (P=.038) group. No significant difference in fracture strength was detected between groups MP and ML, and groups ZP and ZL (P>.05). Predominant fracture types were cohesive for metal groups and adhesive for zirconia groups. CONCLUSION. Fracture strength of a restoration with a metal or a zirconia framework was independent of the veneering techniques. However, the pressing technique over metal frameworks resisted significantly higher fracture loads than zirconia frameworks.

척추교정 티타늄 앵커나사 파단 손상원인 분석 (Failure Analysis of Ti alloy Screws in Fixing Fractured Spines)

  • 최병학;김문규;김승언;심윤임;이영진;정효태;최원열
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.983-988
    • /
    • 2011
  • Failure analyses of the screws in spinal fixation devices were carried out. The fractured screws were retrieved from a patient who had spinal surgery in the thoracic vertebrae from number 10 to 15. The failure occurred one month after the removal of the braces. Microstructures and fracture surfaces were examined by optical and scanning electron microscopy. The microstructures of the screws corresponded to annealed Ti-6Al-4V bar. However, in the vicinity of the screw surface, there was an insufficient number of fine precipitates. Fracture surfaces showed typical fatigue failure modes. Regarding the fact that no machining defects were detected, fatigue crack initiation might have been caused by the lack of precipitates near the screw surfaces. Only the fourth of five fixed screws was severely stress-concentrated by the action of the spinal bones, while the stress of the 4th screw was decreased to half of its acceptable level when the screw was supplemented by one more, which might have been fixed in the 6th vertebra under the 5th position by the switching of its position. The stress simulation was conducted by ANSYS with 3D CAD of PRO/E in order to understand the stress concentration behavior and to provide an effective spinal surgery guide.

티롤리안 위어 스크린 경사에 따른 유량계수 추정 (An Estimation of Discharge Coefficients with the Variations of Tyrolean Weir Screen Angle)

  • 유창환;백유현;오윤근;최익배
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.227-227
    • /
    • 2018
  • 티롤리안 위어(Tyrolean Weir)는 유송잡물 및 유사의 영향이 비교적 높은 산악지역에 설치되는 취수구조물로 대부분 저류면적이 제한된 자류식(Run-Off River) 수력발전 및 소규모 농업용수 취수시설에 적합한 구조물이다. 티롤리안 위어는 일반적인 취수시설과 비교하여 구조물의 규모를 최소화할 수 있어 친환경적 취수구조물로 분류할 수 있다. 아직까지 국내에서는 설치사례가 없고 연구성과 또한 부족하여 적용성에 한계가 있는 것이 사실이다. 본 연구에서는 3차원 유동해석 프로그램인 FLOW-3D를 이용하여 티롤리안 위어의 월류흐름특성을 분석하고 스크린 경사와 월류수위 변화에 따른 유량계수를 산정하였다. 티롤리안 위어 스크린경사에 따른 수치모형실험을 위해 3차원 AUTO CAD 프로그램을 이용하여 위어폭 11.0m, 길이 10m 및 수로경사 2:3의 솔리드 모형을 구성하였으며, 티롤리안 위어 스크린 경사를 $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$, $25^{\circ}$, $30^{\circ}$로 변화시키며 월류수심 변화에 따른 수치모형실험을 수행하였다. 금회 수치해석 분석결과 다음과 같은 결론을 얻을 수 있었다. 1) 티롤리안 위어 스크린 경사가 증가할수록 유량계수가 증가하였다. 2) 월류수심 1.4m일때 월류량의 표준편차는 0.767이며 월류수심 4.4m일때 표준편차는 9.580으로 월류수심이 증가할수록 스크린 경사에 따른 표준편차는 증가하는 것으로 확인되었다. 3) 티롤리안 위어 스크린 경사가 클수록 월류수심은 감소하고 접근수로부 유속이 증가하였으며 스크린 경사가 작을수록 월류수심은 증가하고 유속이 감소하는 경향을 확인하였다. 4) 티롤리안 위어 스크린 경사가 작고 월류수심이 클수록 광정위어와 유사한 흐름특성을 보였다.

  • PDF

Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study

  • Dina Mohamed Ahmed Elawady;Wafaa Ibrahim Ibrahim;Radwa Gamal Ghanem;Reham Bassuni Osman
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권4호
    • /
    • pp.201-211
    • /
    • 2024
  • PURPOSE. The aim of this prospective clinical study was to compare the influence of palatal vault forms on accuracy and speed of intraoral (IO) scans in completely edentulous cases. MATERIALS AND METHODS. Based on the palatal vault form, participants were divided into three equal groups (n = 10 each); Class I: moderate; Class II: deep; Class III: flat palatal vault. A reference model was created for each patient using polyvinylsiloxane impression material. The poured models were digitized using an extraoral scanner. The resultant data were imported as a solid CAD file into 3D analysis software (GOM Inspect 2018; Gom GmbH, Braunschweig, Germany) and aligned using the software's coordinate system to determine its X, Y, and Z axes. Five digital impressions (DIs) of maxilla were captured for each patient using an intraoral scanner (TRIOS; 3Shape A/S, Copenhagen, Denmark) and the resultant Standard Tessellation Language (STL) scan files served as test models. Trueness was evaluated by calculating arithmetic mean deviation (AMD) of the vault area between reference and test files while precision was evaluated by calculating AMD between captured scans to measure repeatability of scan acquisition. The scan time taken for each participant was also recorded. RESULTS. There was no significant difference in trueness and precision among the groups (P = .806 and .950, respectively). Average scan time for Class I and III palatal vaults was 1 min 13 seconds and 1 min 37 seconds, respectively, while class II deep palatal vaults showed the highest scan time of 5 mins. CONCLUSION. Palatal vault form in edentulous cases has an influence on scan time. However, it does not have a substantial impact on the accuracy of the acquired scans.

A STUDY ON THE MARGINAL FIT OF COLLARLESS METAL CERAMIC FIXED PARTIAL DENTURES

  • Yoon Jong-Wook;Yang Jae-Ho;Han Jung-Seok;Lee Jae-Bong
    • 대한치과보철학회지
    • /
    • 제43권6호
    • /
    • pp.707-716
    • /
    • 2005
  • Statement of problem. Collarless metal ceramic fixed partial dentures(FPDs) had an esthetic problem such as opaque reflection in cervical region. To overcome this, modified coping which removed its facial cervical metal could be used. The marginal quality could be worsen according to the amount of its facial metal reduction. Purpose. The purpose of this study was to evaluate marginal fits of collarless metal ceramic FPDs with retainers of modified copings. Material and method. Dentoform maxillary left central incisor and right lateral incisor were prepared for 3-unit collarless metal ceramic FPD and fixed in yellow stone. This model was duplicated to PBT resin dies via CAD/CAM and injection molding. Four different facial margin design groups were investigated. Group A was a coping with a thin facial metal collar, group B was a collarless coping with its facial metal to the shoulder, group C was a collarless coping with its facial metal 1 mm short of the shoulder, and group D was a collarless coping with its facial metal 2 mm short of the shoulder. Seven collarless metal ceramic FPDs per group were fabricated. They were cemented to PBT resin dies with resin cement. After removal of pontics, each retainers were separated and observed under Accura 2000 optical microscope. Then, retainers were embeded in orthodontic resin and cross sectioned faciopalatally. Internal marginal fits of midfacial porcelain margins were observed under FE-SEM. Result and conclusion. Within the limitations of this in vitro study. The following conclusions were drawn. 1. Mean marginal gaps of collarless FPDs were in the $50-60{\mu}m$ range. 2. In midfacial margin, marginal discrepancies were greater in group A than in the experimental groups(p<0.05). 3. In midpalatal margin, marginal gaps were greater in group C and D than in group A and B(p<0.05). 4. Marginal fits of porcelain margins were better than those of metal margins in collarless metal ceramic FPDs. 5. In both teeth, internal marginal gaps of group C and D were greater than those of group A and B(p<0.05).

정확한 기생 성분을 고려한 ITRS roadmap 기반 FinFET 공정 노드별 회로 성능 예측 (Circuit Performance Prediction of Scaled FinFET Following ITRS Roadmap based on Accurate Parasitic Compact Model)

  • 최경근;권기원;김소영
    • 전자공학회논문지
    • /
    • 제52권10호
    • /
    • pp.33-46
    • /
    • 2015
  • 본 논문에서는 ITRS(International Technology Roadmap for Semiconductors)를 따라 스케일 다운된 FinFET 소자의 디지털 및 아날로그 회로의 성능을 예측했다. 회로 성능의 정확한 예측을 위해 기생 커패시턴스와 기생 저항 모델을 개발해 3D Technology CAD 해석 결과와 비교해 오차를 2 % 미만으로 달성했다. 기생 커패시턴스 모델은 conformal mapping 방식을 기반으로 모델링 되었으며, 기생 저항 모델은 BSIM-CMG에 내장된 기생 저항 모델을 핀 확장 영역 구조 변수($L_{ext}$) 변화에 따른 기생 저항 성분 변화를 반영 할 수 있도록 개선했다. 또한, 공정 단위 변화에 대해 소자의 전압전류의 DC 특성을 반영하기 위해 BSIM-CMG 모델의 DC 피팅을 진행하는 알고리즘을 개발했다. BSIM-CMG에 내장된 기생 모델을 본 연구에서 개발한 저항과 커패시턴스 모델로 대체해 압축 모델 내부에 구현하여, SPICE 시뮬레이션을 통해 스케일 다운된 FinFET 소자의 $f_T$, $f_{MAX}$, 그리고 링 오실레이터와 공통 소스 증폭기의 기생 성분으로 인한 특성변화를 분석했다. 정확한 기생 성분 모델을 적용해 5 nm FinFET 소자까지 회로 특성을 정량적으로 제시했다. 공정 단위가 감소함에 따라 소자의 DC 특성이 개선될 뿐만 아니라 기생 성분의 영향이 감소하여, 회로 특성이 향상됨을 예측했다.

재래 된장과 시판 된장의 미생물 오염 및 바이오제닉 아민 함량 분석 (Analysis of Microbiological Contamination and Biogenic Amines Content in Traditional and Commercial Doenjang)

  • 이학태;김종호;이상선
    • 한국식품위생안전성학회지
    • /
    • 제24권1호
    • /
    • pp.102-109
    • /
    • 2009
  • 전통 방법으로 제조한 재래 된장 4종과 개량식 방법으로 제조한 시판 된장 6종을 선정해 바실러스 세레우스균, 황색포도상구균등 미생물 오염도 검사와 바이오제닉 아민류에 대한 모니터링 검사를 실시하였다. 된장 10종 모두에서 대장균과 대장균군은 검출되지 않았으나, 일반세균은 모든 시료에서 검출되었다. 전체적으로 검출된 일반세균은 $6.2{\pm}0.1\;\log\;CFU/g{\sim}7.9{\pm}0.1\;\log\;CFU/g$의 분포를 나타내었다. 시료별로는 가정에서 재래식으로 담근 된장이 $7.8{\pm}0.1\;\log\;CFU/g{\sim}7.9{\pm}0.1\;\log\;CFU/g$의 분포를 보여 $6.2{\pm}0.1\;\log\;CFU/g{\sim}7.4{\pm}0.1\;\log\;CFU/g$의 분포를 보인 시판된장 보다 높은 일반세균수가 검출되었다. 식중독균 검사결과 황색포도상구균과 살모넬라균, 그리고 리스테리아균은 검출되지 않았다. 그러나 바실러스 세레우스균은 $H1{\sim}H4$를 제외한 모든 샘플에서 검출되었으며, $2.3{\pm}0.4 \log\;CFU/g{\sim}2.6{\pm}0.1\;\log\;CFU/g$의 분포를 나타내었고, 각 시료별로 검출된 바실러스 세레우스 균수가 큰 차이를 나타내지는 않았다. 바이오제닉 아민의 분석 결과 재래식 방법으로 제조한 된장인 $L1{\sim}L4$에서 PUT의 함량이 높게 나타났으나 시판된장 $H2{\sim}H5$에 비하면 1/10수준이었다. 시판된장인 $H1{\sim}H6$에서는 PUT, TYR. HIS 의 함량이 높게 나타났다. 대부분의 바이오제닉 아민의 경우 시판 된장이 일반 재래식 된장보다 전반적으로 높은 함량으로 검출되었다.

여러 가지 충돌 상황에 따른 FRP 어선 간의 충돌 해석 (Collision Analysis between FRP Fishing Boats According to Various Configurations)

  • 장인식;김용섭;김일동
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권4호
    • /
    • pp.253-262
    • /
    • 2006
  • 경제규모의 증대와 더불어 해상물동량이 많아지고 운행하는 선박의 숫자가 증가함에 따라 해상에서의 해난 사고가 빈번하게 발생하고 있다. 선박의 충돌 사고에 대한 연구는 주로 충돌 사고의 원인 분석에 중점을 두어 왔으나 보다 정확한 분석을 위해서는 역학적인 해석이 더 첨가되어야 한다. 본 연구는 FRP 재질의 어선간의 여러 충돌 상황에서의 시간에 따른 변형 거동에 대한 것이다. 선체에 대한 3차원 기하학적인 모델링을 수행 한 후, 유한요소 모델을 구성하고 역학적인 해석 기법인 유한 요소법을 이용하여 동적 해석을 수행하였다. 7.93톤급의 소형어선과 39톤급의 대형어선을사용하고 두 가지의 충돌각도($90^{\circ},\;135^{\circ}$)와 세 가지의 충돌속력(5, 10, 15 노트)의 조건을 조합하여 해석을 수행하였으며 각각의 경우에 대하여 응력분포와 변형상태를 살펴보았다. 전체적으로 $90^{\circ}$ 충돌 각도에서 $135^{\circ}$ 경우보다 응력이 컸으며, 두 선박이 모두 운항 중에 발생하는 충돌에서 더 큰 최대 응력이 발생하였다. $90^{\circ}$ 충돌각도의 경우 소형어선 간 충돌이나 소형 어선과 대형 어선간의 충돌에서도 충돌하는 전체의 선수부보다 충돌당하는 선체의 측면 부위에서 큰 응력이 발생하였다. $135^{\circ}$ 충돌각도로 정지된 소형 어선과 대형어선이 충돌하는 경우에는 대형 어선에서 치대 응력이 발생하였다. 150 ms의 해석시간인 경우 $90^{\circ}$ 충돌각도에서는 10knot, 15knot 모두 충돌하는 선체나 층돌 당하는 선체에서 파단이 발생하는 것으로 나타났다. 해석 결과는 추후에 부분 별 강도를 고려한 선체의 설계나 충돌사고재구성을 위한 기초 데이터로 사용될 수 있다.

  • PDF

원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구 (A Study on Construction and Application of Nuclear Grade ESF ACS Simulator)

  • 이숙경;김광신;손순환;송규민;이계우;박정서;홍순준;강선행
    • 방사성폐기물학회지
    • /
    • 제8권4호
    • /
    • pp.319-327
    • /
    • 2010
  • 공학적 안전설비 공기정화계통과 관련된 실험 수행을 위해 원자력등급 ESF 공기정화계통 시뮬레이터를 설계, 제작, 검증하였다. 영광 5,6호기 주제어실 공기정화계통의 공급자 정보, 도면 등을 기준으로 실사를 통해 치수를 확인하여 3D CAD 모델을 작성하였다. 모델과 현장 계통의 실측 유량을 기준으로 CFD 분석을 수행하였다. 공기정화계통으로 유입되는 공기는 $30^{\circ}C$, 유동형태는 균일한 것으로 가정하고, 검사 기록지에 의한 주제어실 ESF 공기정화계통의 유량이 12,986 CFM이고, $610{\times}610mm^2$의 HEPA 필터가 9개 설치되어 있으므로 HEPA 필터 단면를 지나는 유속은 1.83 m/s이다. 주제어실 공기정화계통 모델링시 공기 유동이 흐르지 않는 필터 테두리 지지대를 고려하여 현장과 유사한 유동현상을 모사하였다. 약 8 m/s로 기록된 활성탄 흡착기 하단의 공기유동은 별도의 분석을 통해 7 m/s 이상의 유속이 모사되도록 CFD 분석하였다. 연료건물 비상배기계통 및 비상노심냉각계통 기기실 배기정화계통의 공기정화계통에 대해서도 CFD 분석한 결과, 시뮬레이터의 유속을 조절하면 세가지 ESF 공기정화계통을 모두 모사할 수 있음을 확인하였다. CFD 분석 후 시뮬레이터를 원자력등급으로 제작하였고, 본 실험에 착수하기 전에 공기유동 분포도실험을 통해 시뮬레이터의 신뢰도를 검증하였다. 검증결과 중급 필터를 장착한 상태에서 시뮬레이터의 필터 지지대 부분을 제외한 내부에서 공기유동이 고르게 분포함을 확인하였고, 제작된 시뮬레이터는 Reg. Guide 1.52(Rev.3) 개정 내용 확인을 위한 실험에 사용되었다.