• Title/Summary/Keyword: 5D CAD

Search Result 277, Processing Time 0.03 seconds

The Impression Evaluation according to Coloration of Shirts and Ties (I) - On Tone-on-Tone Coloration of Purple and Green - (셔츠와 타이의 배색방법에 따른 남성복의 인상 평가 (제1보) - 보라, 초록색의 톤 온 톤 배색을 중심으로 -)

  • Lim, Ji-Young;Kang, Kyung-Ja
    • Korean Journal of Human Ecology
    • /
    • v.14 no.5
    • /
    • pp.833-846
    • /
    • 2005
  • The purpose of this study is to find out the various impressions that tone-on-tone coloration of shirts and ties gives. This experiment was based on the $2\times4\times4\times2$ factorial designs; colors (purple and green), shirt tones (vivid, light, dull, and dark), tie tones (vivid, light, dull, and dark) and perceivers' genders (male and female). The materials in the experiment developed for this study were composed of various stimuli and the response scales for each stimulus. The stimuli were 32 upper body photographs, which were color printed by CAD system (4D-box program). We unified those colors of shirts and ties, and then made shirt and tie tone different. 27 bi-polar adjectives, each of which was graded into seven in its degree, were used to evaluate the impression. The subjects of this research were 192 male and 192 female college students in Gyeongnam province including Jinju City. The data was analyzed by using SPSS program. Analyzing methods were one-way ANOVA and LSD test. The items of the adjectives were classified into 5 impression dimensions; potency, activeness, attractiveness, visibility and tenderness. In conclusion the impression through matching shirts and ties could be varied by the colors and the tones of shirts and ties. This study can be used as the basic color data in the males' clothes market which gradually pursuits high-quality, personality, and variety.

  • PDF

Development of Prototyping and Die/Mold Manufacturing Technology using Rapid Prototyping(SLA) (쾌속 3차원 조형법을 이용한 시작기술 및 시작금형)

  • Park, K.;Lee, S.C.;Jung, J.H.;Yang, D.Y.;Yoon, J.R.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.5
    • /
    • pp.1582-1589
    • /
    • 1996
  • Rapid prototyping is a new prototyping technology which produces three dimensional part models directrly from CAD data and has been extensively applied to various manufacturing processes. There are many types of rapid prototyping systems due to their building principles and materials. In this work, Stereolithography Appaaratus(SLA) which is the most widely-used rapid prototyping system is introduced to achieve die/mold technology innovation. For the purpose, the prototyping technology using SLA is developed such that patterns of which shapes are quite complicated are successfully produced with high accuracy. Using these patterns, prototype die/molds are efficientrly manufactured; a turbocharger rotor, a fan and a wheel patterns, prototype die/molds are efficienterly manufactured ; a turbochager rotor, a fan and a wheel pattern are made, and the molds of the investment casting, the injection molding and the die casting are manufactured respectively. The casting products are produced using these molds and it turns out that these methods are quitre effective for manufacturing products of complicated geometry from the viewpoint of efficiency and productivity.

Comparative study in marginal accuracy of several all ceramic crowns (전부도재관의 변연 적합도 비교평가)

  • Kim, Jeong-Mi;Jeoung, Su-Ha
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.87-92
    • /
    • 2008
  • Purpose: In this study, we tried to compare marginal accuracy when produce ceramic crown using all ceramic materials and existent metal-ceramic system. Material and methods: All-ceramic systems were E-max (Ivoclar/Vivadent, Lichtenstein), Lava(3M, U.S.A.) and Wol-ceram(Teamziereis, Germany). Metal-ceramic system(PFG) was composed of Au-Pt alloy (Metalor, Switzerlandand) and overlying ceramic(D-sign, Ivoclar/Vivadent, Lichtenstein). We fabricated metal master die with upper diameter of 7.95mm, bottom diameter of 9.00mm, height of 5.00mm, and taper of $6^{\circ}$. All ceramic system used 0.5mm thickness ceramic coping, while metalceramic system used 0.3 thickness metal coping. By adding dentin and enamel ceramics on each coping, a crown with a proximal thickness of 1.0 mm and occlusal thickness of 2.0mm was fabricated. Pressure of 2kg was applied for 10 seconds on each crown with static load compressor. Before and after cementation, we measured the marginal gap at 4 points of each crown using optical microscope. The data was analyzed using a Student's t test and repeated-measures of analyses of variance(ANOVA) followed by a Bonferroni test. A p value<0.05 was considered significant. Results: As experiment results, marginal accuracy of wol-ceram and Lava is no good when compared with marginal accuracy of PFG. But marginal accuracy of E.max is good when compared with PFG. This result showed not significant. The marginal accuracy of E.max is good when compared with marginal accuracy of wol-ceram and Lava. Conclusion: The marginal accuracy of E.max is very good when compared with marginal accuracy of another group.

  • PDF

The role of internal architecture in producing high-strength 3D printed cobalt-chromium objects

  • Abdullah Jasim Mohammed;Ahmed Asim Al-Ali
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.2
    • /
    • pp.91-104
    • /
    • 2024
  • PURPOSE. The objectives of the current study were to estimate the influence of self-reinforced hollow structures with a graded density on the dimensional accuracy, weight, and mechanical properties of Co-Cr objects printed with the direct metal laser sintering (DMLS) technique. MATERIALS AND METHODS. Sixty-five dog-bone samples were manufactured to evaluate the dimensional accuracy of printing, weight, and tensile properties of DMLS printed Co-Cr. They were divided into Group 1 (control) (n = 5), Group 2, 3, and 4 with incorporated hollow structures based on (spherical, elliptical, and diamond) shapes; they were subdivided into subgroups (n = 5) according to the volumetric reduction (10%, 15%, 20% and 25%). Radiographic imaging and microscopic analysis of the fractographs were conducted to validate the created geometries; the dimensional accuracy, weight, yield tensile strength, and modulus of elasticity were calculated. The data were estimated by one-way ANOVA and Duncan's tests at P < .05. RESULTS. The accuracy test showed an insignificant difference in the x, y, z directions in all printed groups. The weight was significantly reduced proportionally to the reduced volume fraction. The yield strength and elastic modulus of the control group and Group 2 at 10% volume reduction were comparable and significantly higher than the other subgroups. CONCLUSION. The printing accuracy was not affected by the presence or type of the hollow geometry. The weight of Group 2 at 10% reduction was significantly lower than that of the control group. The yield strength and elastic modulus of the Group 2 at a 10% reduction showed means equivalent to the compact objects and were significantly higher than other subgroups.

Effects of implant thread profile on insertion stress generation in cortical bone studied by dynamic finite element simulation (유한요소 모사해석을 통한 임플란트 나사산 형상이 치밀골의 식립응력에 미치는 영향 분석)

  • Yu, Won-Jae;Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.279-286
    • /
    • 2014
  • Purpose: The aim of this study was to investigate the effect of implant thread profile on the marginal bone stresses which develop during implant insertion. Materials and methods: Four experimental implants were created by placing four different thread systems on the body ($4.1mm{\times}10mm$) of the ITI standard implant. The thread types studied in this study included the buttress, v-shape, reverse buttress, and square shape threads. In order to examine the insertion stress generation, 3D dynamic finite element analysis was performed which simulated the insertion process of implants into a 1.2 mm thick cortical bone plate (containing 3.5 mm pilot hole) using a PC-based DEFORM 3D (ver 6.1, SFTC, Columbus, OH, USA) program. Results: Insertion stresses higher than human cortical bone developed around the implants. The level of insertion stresses was much different depending on the thread. Stress level was lowest near the v-shape thread, and highest near the square shaped thread. Difference in the interfacial bone stress level was more noticeable near the valley than the tip of the threads. Conclusion: Among the four threads, the v-shape thread was turned out to minimize the insertion stress level and thereby create better conditions for implant osseointegration.

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

Evaluation of the stress distribution in the external hexagon implant system with different hexagon height by FEM-3D (임플란트 hexagon 높이에 따른 임플란트와 주위 조직의 응력분포 평가)

  • Park, Seong-Jae;Kim, Joo-Hyeun;Kim, So-Yeun;Yun, Mi-Jung;Ko, Sok-Min;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.36-43
    • /
    • 2012
  • Purpose: To analyze the stress distribution of the implant and its supporting structures through 3D finite elements analysis for implants with different hexagon heights and to make the assessment of the mechanical stability and the effect of the elements. Materials and methods: Infinite elements modeling with CAD data was designed. The modeling was done as follows; an external connection type ${\phi}4.0mm{\times}11.5mm$ Osstem$^{(R)}$ USII (Osstem Co., Pusan, Korea) implant system was used, the implant was planted in the mandibular first molar region with appropriate prosthetic restoration, the hexagon (implant fixture's external connection) height of 0.0, 0.7, 1.2, and 1.5 mm were applied. ABAQUS 6.4 (ABAQUS, Inc., Providence, USA) was used to calculate the stress value. The force distribution via color distribution on each experimental group's implant fixture and titanium screw was studied based on the equivalent stress (von Mises stress). The maximum stress level of each element (crown, implant screw, implant fixture, cortical bone and cancellous bone) was compared. Results: The hexagonal height of the implant with external connection had an influence on the stress distribution of the fixture, screw and upper prosthesis and the surrounding supporting bone. As the hexagon height increased, the stress was well distributed and there was a decrease in the maximum stress value. If the height of the hexagon reached over 1.2mm, there was no significant influence on the stress distribution. Conclusion: For implants with external connections, a hexagon is vital for stress distribution. As the height of the hexagon increased, the more effective stress distribution was observed.

Survey Analysis on the Application of Computer Software in Landscape Architecture (조경분야에서 컴퓨터 이용의 실태분석)

  • 허상현
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.3
    • /
    • pp.81-89
    • /
    • 2001
  • The purpose of this research is to provide for some useful data for computer-related courses of the landscape science, assuming that computers are being and should be used more and more in landscape architecture and therefore, that landscape science students need to respond positively to such a trend. For this purpose, landscape architecture studios and their landscape architects were surveyed for their computer and its program uses as well as their satisfaction with the utility of computer for their landscape works. The results of this research are as follows; 1) 10.7% of the landscape architects surveyed answered that they had learned about their necessary softwares at school, while 61.6% of the studios surveyed were less satisfied with their employees' poor computing ability. Such findings suggest a lack of computer-related courses in landscape science and therefore, that more computer-related courses should be introduced for landscape science students together with the necessary software education. 2) Too few landscape softwares are being used by the landscape architecture studios; such softwares as AutoCAD, Photoshop, 3D Max, Excel, PowerPoint and 한글 account for more than 90% of the landscape architecture softwares being used currently. Quite naturally, landscape students need to be trained on these softwares above all. 3) It was found hat he area of work using the computer most was ˝design works˝(84.5%), followed by ˝documentation˝(83.8%), ˝image editing˝(75.1%), ˝cost calculation˝(68.2%), ˝presentation˝(68.1%), ˝analysis˝(37.8%) and ˝rendering˝(35%). It was regretable to discover that such areas requiring more computing work as ˝analysis˝ and ˝rendering˝ were still worked manually. So it sis deemed necessary for landscape science courses to enhance their computer education of such areas first of all.

  • PDF

Stability Evaluation of Bump Crossing and Loading of Proto-type Mini-Forwarder by Computer Simulation (컴퓨터 시뮬레이션을 이용한 소형 임내차 시작기의 장애물 통과 및 적재 안정성 평가)

  • Park H. K.;Kim K. U.;Shim S. B.;Kim J. W.;Park M. S.;Song T. Y.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.6 s.113
    • /
    • pp.366-372
    • /
    • 2005
  • The objective of this study was to evaluate the bump crossing and loading stability of a proto-type mini-forwarder under development. The evaluation was performed by computer simulation using a multi-body dynamic analysis program, Recur- Dyn 5.21. The proto-type was modeled and its properties such as mass, mass center, and mass moment of inertia were determined using 3D CAD modeler, Solid Edge 8.0. The $\%$ errors of masses, mass center, mass moment of inertia, and vertical motion of the model were within less than $10\%$ and the model's behavior agreed relatively well with those of the proto-type when traversing over a rectangular bump. Using the validated model, bump crossing of the proto-type was simulated and the loading limit was determined. It was found that effects of the shapes of bump on the bump crossing performance was insignificant within the practical heights of bumps. Stability of bump crossing increased with loading. However, loading of longer logs than 2.7 m made the crossing unstable because the ends of logs contacted ground when traversing over the bump. The maximum loading capacity of the proto-type was estimated to be 7.8 kN of 2.7 m long logs.

A comparison of the fracture resistances of endodontically treated mandibular premolars restored with endocrowns and glass fiber post-core retained conventional crowns

  • Guo, Jing;Wang, Zhiming;Li, Xuesheng;Sun, Chaoyang;Gao, Erdong;Li, Hongbo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.489-493
    • /
    • 2016
  • PURPOSE. This in-vitro study aimed to evaluate the fracture resistances and failure modes of endodontically treated mandibular premolars restored with endocrowns and conventional post-core retained crowns. MATERIALS AND METHODS. Thirty mandibular premolars were assigned into three groups (n=10): GI, intact teeth; GE, teeth with endocrowns; GC, teeth with conventional post-core supported crowns. Except for the teeth in group GI, all specimens were cut to 1.5 mm above the cementoenamel junction and endodontically treated. Both endocrowns and conventional crowns were fabricated from lithium-disilicate blocks using a CEREC 3D CAD/CAM unit. All specimens were subjected to thermocycling and then to $45^{\circ}$ oblique compressive load until fracture occurred. The fracture resistance and failure mode of each specimen were recorded. Data were analyzed with one-way ANOVA and LSD Post Hoc Test (${\alpha}=.05$). RESULTS. The fracture resistances of GE and GC were significantly lower than that of GI (P<.01), while no significant difference was found between GE and GC (P=.702). As of the failure mode, most of the specimens in GE and GC were unfavorable while a higher occurrence of favorable failure mode was presented in GI. CONCLUSION. For the restoration of mandibular premolar, endocrown shows no advantage in fracture resistance when compared with the conventional method. Both of the two methods cannot rehabilitate endodontically treated teeth with the same fracture resistances that intact mandibular premolars have.