• Title/Summary/Keyword: 50nm

Search Result 2,618, Processing Time 0.04 seconds

Antibacterial and Growth Inhibitory Effects of Liriope Platyphylla Ethanol Extract on Streptococcus Mutnas and Porphyromonas Gingivalis (맥문동 에탄올 추출물(Liriope platyphylla ethanol extract)의 Streptococcus mutnas와 Porphyromonas gingivalis에 대한 항균력과 성장억제 효과)

  • Su-Hyeon Chun;Ju-Yeon Park;Hyeon-Ji Lee;Ji-Eun Jeong;Eun-Suk Cha;Chung-Mu Park;Hyun-Seo Yoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.4
    • /
    • pp.125-133
    • /
    • 2023
  • Purpose : This study aimed to analyze the antibacterial activity of Liriope platyphylla ethanol extract (LPEE) against Streptococcus mutans and Porphyromonas gingivalis and to validate its potential for the prevention and treatment of dental caries, gingivitis, and periodontal disease. Methods : To verify the antibacterial effect of L. pulsatilla ethanolic extract (LPEE) against S. mutans and P. gingivalis, the disk diffusion method was used to determine the inhibition zones at concentrations of 50, 100, 200, and 300 mg/㎖. To determine the minimum inhibition concentration (MIC), the final dose of LPEE was .2, .4, .8, 1.6, 2.5, and 5.0 mg/㎖, and the minimum bactericidal concentration (MBC) was determined based on the MIC results. To confirm the growth inhibitory effect of LPEE on both pathogens, the absorbance was measured at 600 nm after each incubation for 0, 3, 6, 12, and 24 hr at concentrations of .8, 1.6, 2.5, and 5.0 mg/㎖. Results : The cytotoxicity of LPEE was evaluated and the cell viability was more than 70 % at 400 mg/㎖. Therefore, concentrations of 50, 100, 200, and 300 mg/㎖ were used in this study. The antimicrobial effect against S. mutans was seen at 100 mg/㎖ and grew in a concentration-dependent manner, while P. gingivalis was effective at 50 mg/㎖ with the dose dependency. The MIC was .8 mg/㎖ for both strains, and the MBC was 1.6 mg/㎖ with the same results. The growth inhibitory effect of LPEE on S. mutans and P. gingivalis was observed, even at low concentrations. Conclusion : The antibacterial effect of LPEE was evaluated through the analysis of MIC, MBC, and growth inhibition effect on S. mutans and P. gingivalis, which suggests LPEE might have the possibility of utilization as a preventive and therapeutic composition for oral diseases.

DC/RF 중첩형 마그네트론 스퍼터링법으로 증착한 ITO 초박막의 SnO2 함량에 따른 전기적 ,광학적 특성 및 미세구조 변화

  • Gang, Se-Won;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.280-281
    • /
    • 2012
  • 차세대 디스플레이에서 3차원 감성 터치 또는 플렉시블 기판 등에 사용되고 있는 ITO(Tin-doped Indium Oxide) 박막은 고 해상도 및 소자 효율 향상을 위해 전 가시광 영역에서 높은 투과율이 요구되고 있다. 일반적으로 ITO 박막은 두께 감소에 따라 빛의 두께 산란 없이 전 가시광 영역에서 높은 투과율을 가지는 반면, 두께가 감소할수록 박막 성장 시 비정질 기판의 영향을 크게 받아 박막 결정성 감소와 더불어 전기전도성이 감소되는 경향을 보인다. 특히, 매우 얇은 두께에서의 ITO 박막 물성은 초기 박막 핵 생성 및 성장과 증착 공정 중에 발생하는 고 에너지 입자(산소 음이온, 반사 중성 아르곤 등)의 박막 손상에 대한 영향을 크게 받을 뿐만 아니라 ITO 박막 내의 SnO2 도핑함량에도 매우 의존한다. 따라서, 매우 얇은 두께에서 높은 투과율과 뛰어난 전기전도성을 동시에 가지는 고품질 ITO 초박막 제조를 위해서는 박막 초기 핵 성장 제어기술 및 SnO2 함량에 따른 ITO 초박막의 전기적, 광학적 거동에 관한 연구가 필요하다. 본 연구에서는 다양한 SnO2 함량에서 고품질의 ITO 초박막을 DC/RF 중첩형 마그네트론 스퍼터링법을 이용하여 박막 증착 중에 발생하는 고에너지 입자의 기판충격으로 인한 박막손상을 최소화하여 증착된 박막의 전기적, 광학적 특성 및 미세구조를 관찰하였다. 그리고 전체파워에서 RF/(RF+DC) 비율을 제어하여 증착한 ITO 초박막의 물성을 최적화 하였으며, 상온 및 결정화 온도 이상에서 다양한 SnO2 함량을 가진 ITO 박막을 두께(150 nm, 25 nm)에서 각각 증착하여 전기적, 광학적 거동 및 XRD를 통한 박막의 미세구조 변화를 비교 분석하였다. 그리고 증착된 모든 ITO 초박막에서 가시광 투과율은 빛의 두께 산란 없는 높은 투과율(>85 %) 을 보이는 것을 확인 할 수 있었다. 증착된 ITO 박막의 전기적 특성 및 미세구조는 RF/(DC+RF)비율 50%에서 최적임을 확인하였다. 이는 RF/(DC+RF) 비율 증가에 따른 캐소드 전압 최적화로 박막의 초기 핵 성장 과정에서 기판상의 고에너지 입자로 인한 박막 손상의 감소 및 리스퍼터 되는 산소량을 최적화 시키고, 이는 박막의 결정성 향상으로 이어져, 박막내의 결함 밀도 감소 및 SnO2 고용 효율을 증가시켜 전기전도성 향상에 기인하였다고 판단된다. 또한, 증착된 ITO 초박막은 SnO2 함량 변화에 따라 박막의 결정성 및 전기적 특성에서 미세한 변화를 보였다. 이러한 ITO 박막의 물성변화는 박막 두께 감소에 따른 결정성 감소와 함께 SnO2의 고용 한계 변화로 인한 것으로 판단된다. 또한, RF/(DC+RF) 비율의 증가에 따른 ITO 초박막의 전기적, 광학적 및 미세구조는 Vp-Vf의 변화와 관련하여 설명되어 진다.

  • PDF

Determination of Four Macrolide Antibiotics Residues in Chicken Muscle Using High-Performance Liquid Chromatography (액체크로마토그래피를 이용한 닭고기 시료에서의 마크로라이드계 동시분석법 개발)

  • Lee, Sang-Hee;Yoo, Miyoung;Shin, Dong-Bin
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • A simple and rapid method has been developed and validated for simultaneous determination of each macrolides residues (spiramycin, josamycin, tilmicosin, tylosin) in chicken muscle by high-performance liquid chromatography- photo diode array (HPLC-PDA). Chicken muscle sample have been extracted with liquid-liquid extraction process; analytes was extracted by acetonitrile, and then defatted with hexane saturated by acetonitrile. The HPLC separation was performed on a Unison UK-$C_{18}$ ($150mm{\times}3.0mm$, $3{\mu}m$) with a gradient system of 0.1% trifloroacetic acid (TFA) and 0.1% trifloroacetic acid (TFA) in acetonitrile as the mobile phase. The drugs were detected at 232 nm for spiramycin and josamycin, and 287 nm for tilmicosin and tylosin. The limits of quantification (LOQs) were between 27 and $59{\mu}g/kg$; and the intra- and inter-day precision (relative standard deviation; RSD) was between 0.9-13.2 and 2.4-13.1%, respectively in chicken muscle sample. The method may has been successfully applied for multiresidue determination of four macrolides below the maximum residue limits (MRLs) established by the European Union (EU).

Comparison of Anaerobic Digestion for food wastewater and food waste by HADS Pilot Plant (HADS Pilot Plant를 이용한 음폐수와 음식물쓰레기의 혐기성 소화 비교)

  • Ju, Donghun;Lee, Jungmin;Park, Seongbum;Sung, Hyunje
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.245-245
    • /
    • 2010
  • 우리나라 생활폐기물 중 음식물쓰레기는 가장 많은 부분을 차지하고 있다. 또한, 음식물쓰레기에서 발생되는 음폐수의 발생량은 8,926톤/일에 달하고 있지만, 이 중 극히 일부만이 하수처리장 등에서 병합 처리되고 있고 대부분은 해양 투기되고 있는 실정이다. 이에 본 연구에서는 독일 GBU사로부터 중온/습식/이상 혐기성 소화 기술을 도입하여 HADS Pilot Plant를 설치하였고, 2008년 3월부터 국내 음폐수 및 음식물쓰레기에 적합한 최적의 운전기술을 확보하기 위한 Pilot Test를 실시하였다. 본 실험에 사용된 HADS Pilot Plant는 산발효조($6m^3$), 메탄발효조($50m^3$), 안정화조/가스저장조($40m^3$)그리고 가스 소각기로 구성되어 있다. 그리고 적용 음폐수 및 음식물쓰레기는 경기도 Y군에 위치한 사료화 시설에 반입되는 것을 이용하였는데 음폐수는 평균 TS 13.5%, VS 80%, pH $3.7{\pm}0.2$의 성상을 나타내었다. 이를 이용해 계단식으로 유기물 부하를 증가시키면서 $4kgVS/m^3/d$까지 적용하며 중온 상태에서 혐기성 소화를 실시한 결과, $0.8Nm^3/kgVS_{rem}/d$의 바이오가스 회수 및 85%의 VS 감량이 가능함을 확인하였다. 그리고 음식물쓰레기는 음폐수와 달리 1차 파쇄/선별기 및 배관상에 설치되는 2차 미세파쇄/선별기를 통한 전처리를 실시하였고, 1차 파쇄/선별 후 평균적으로 TS가 17.4%, VS는 81%, pH는 $3.85{\pm}0.2$의 성상을 나타내는 음식물쓰레기를 2차 미세파쇄/선별기를 거쳐 Pilot Plant의 산발효조에 투입하여 중온상태에서 혐기성 소화를 실시하였다. 음폐수 적용시와 마찬가지로 계단식으로 유기물 부하를 증량하면서 $4kgVS/m^3/d$까지 적용하여 운전하였고, 그 결과 약 $0.9{\sim}1.2Nm^3/kgVS_{rem}/d$의 바이오가스 회수와 85~87%의 VS 감량 효율을 확인하였다. 음폐수와 음식물쓰레기의 혐기성 소화 실험 결과, 제거된 VS량을 기준으로 보았을 때, 음식물쓰레기에서 더 많은 바이오가스 발생하였는데 이는 음식물쓰레기에 존재하는 고형물이 미생물들의 서식 공간으로 활용됨에 따라 혐기성 소화 과정에서 일어나는 혼합 발효 및 공영양 대사가 음폐수 대비 좀 더 수월하게 일어날 수 있게 된 데에 따른 결과라고 생각된다. 당사의 HADS Pilot Plant test에서는 계단식의 순차적인 유기물 부하 증량과 총VFA/총 알카리도 비율을 0.3~0.4 수준이하로 유지하며 운전함에 따라 음폐수와 음식물 모두에서 안정적으로 $4kgVS/m^3/d$까지의 유기물 부하 적용이 가능하였다. 또한, 생산된 바이오가스 내 메탄의 함량은 60~65%를 유지하였으며, 메탄발효조의 pH는 별도의 조절이 없이도 운전기간 동안 평균 7.8~7.9 수준을 유지하였다. 이처럼 pH 3.7~3.8의 음폐수 또는 음식물쓰레기의 투입에도 안정적인 완충능력을 보여준 것은 소화조 내에서 기질로부터 분해되어져 나오는 암모니아와 이산화탄소가 강력한 버퍼 시스템을 구축하고 있음에 따른 결과로 사료된다. 그리고 음폐수와 음식물쓰레기의 경우 모두 85%이상의 높은 VS 제거율을 보여주었는데 이는 당사의 HADS Pilot Plant 소화조의 구조가 내통과 외통으로 구분되어져 있음에 따라 plug flow + CSTR의 특징을 가짐에 따른 결과로 판단된다. 상기한 결과를 바탕으로 향후에는 $5kgVS/m^3/d$ 수준의 유기물 부하 적용운전도 계획하고 있다.

  • PDF

Exploring the feasibility of Salmonella Typhimurium-specific phage as a novel bio-receptor

  • Choi, In Young;Park, Do Hyeon;Chin, Brayan A.;Lee, Cheonghoon;Lee, Jinyoung;Park, Mi-Kyung
    • Journal of Animal Science and Technology
    • /
    • v.62 no.5
    • /
    • pp.668-681
    • /
    • 2020
  • The purpose of this study was aimed to isolate a Salmonella Typhimurium-specific phage (KFS-ST) from washing water in a poultry processing facility and to investigate the feasibility of the KFS-ST as a novel bio-receptor for the magnetoelastic (ME) biosensor method. KFS-ST against S. Typhimurium was isolated, propagated, and purified using a CsCl-gradient ultracentrifugation. Morphological characteristics of KFS-ST were analyzed using transmission electron microscopy (TEM). Its specificity and efficiency of plating analysis were conducted against 39 foodborne pathogens. The temperature and pH stabilities of KFS-ST were investigated by the exposure of the phage to various temperatures (-70℃-70℃) and pHs (1-12) for 1 h. A one-step growth curve analysis was performed to determine the eclipse time, latent time and burst size of phage. The storage stability of KFS-ST was studied by exposing KFS-ST to various storage temperatures (-70℃, -20℃, 4℃, and 22℃) for 12 weeks. KFS-ST was isolated and purified with a high concentration of (11.47 ± 0.25) Log PFU/mL. It had an icosahedral head (56.91 ± 2.90 nm) and a non-contractile tail (225.49 ± 2.67 nm), which was classified into the family of Siphoviridae in the order of Caudovirales. KFS-ST exhibited an excellent specificity against only S. Typhimurium and S. Enteritidis, which are considered two of the most problematic Salmonella strains in the meat and poultry. However, KFS-ST did not exhibit any specificity against six other Salmonella and 27 non-Salmonella strains. KFS-ST was stable at temperature of 4℃ to 50℃ and at pH of 4 to 12. The eclipse time, latent time, and burst size of KFS-ST were determined to be 10 min, 25 min and 26 PFU/ infected cell, respectively. KFS-ST was relatively stable during the 12-week storage period at all tested temperatures. Therefore, this study demonstrated the feasibility of KFS-ST as a novel bio-receptor for the detection of S. Typhimurium and S. Enteritidis in meat and poultry products using the ME biosensor method.

GLAD법으로 증착한 Smart window용 WO3와 TiO2의 전기변색적 특성 비교

  • Kim, Seong-Han;Song, Pung-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.198-198
    • /
    • 2015
  • 전기변색재료는 전압을 인가하였을 때 전계방향에 따라 가역적으로 색이 변화하는 재료를 말한다. 스마트윈도우용 전기 변색재료는 지속적으로 전기를 가해줄 필요 없이 한번 변색되면 색이 지속되는 특징을 가지므로 에너지 효율적으로 우수하여 태양열 차단 창호나 디스플레이 분야에 응용될 것으로 기대된다. 이러한 전기 변색재료에는 산화형 전기 변색 재료, 환원형 전기 변색 재료가 있는데 이중 가장 널리 연구되고 있는 재료는 환원형 전기변색재료이다. 대표적인 재료로 $WO_3$가 쓰이는 데 이는 전기 변색적 특성이 우수하고 또한 내구성이 다른 재료에 비해 우수하다는 장점 때문이다. 그러나, 상용화를 위해서는 내구성의 개선이 요구되고 있다. 한편, $TiO_2$는 안정성이 매우 뛰어나지만 전기변색적 특성이 $WO_3$에 비해 낮은 점이 지적되고 있다. 이러한 $WO_3$$TiO_2$ 박막은 스퍼터링 또는 sol-gel법 등으로 제작되고 있는데, 일반적으로 스퍼터링의 경우 치밀한 박막이 형성되기 때문에 Porous 한 박막을 얻기 힘들다. 따라서 본 연구에서는 기판에 입사하는 스퍼터 입자들의 각도를 조절하여 shadowing 효과로 인해 박막의 구조가 porous해지는 Glancing angle deposition을 도입하였다. 이러한 증착법을 이용하여 $WO_3$$TiO_2$를 각도를 조절하여 증착하고 $TiO_2$$WO_3$ 박막의 특성을 비교하여 본다. 두께 300 nm를 가지는 $WO_3$$TiO_2$ 박막은 GLAD RF 마그네트론 스퍼터링법을 이용하여 Corning glass(corning E-2000)기판 위에 증착하였다. 기판 입사 각도는 $0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$로 증착하였고 직경 3 in의 $TiO_2$, $WO_3$ 타겟을 사용하였다. 또한 스퍼터링 파워는 400 W, 작업압력 1.0 Pa, 그리고 스퍼터링 가스는 O2/Ar+O2 유량 10%에서 30%로 증착을 상온에서 진행하였다. 전기화학적 특성을 평가하기 위하여 $TiO_2$$WO_3$ 박막을 100 nm 두께의 ITO/glass 위에서 증착하였다. 박막의 미세구조는 XRD와 SEM을 통해 확인하였고, 전기화학적 특성은 Ar 분위기의 Glove box안에서 parstat 2273을 통해 측정하였다. 전해질은 1 M $LiPF_6/PC$로 진행하였고, 대향 전극는 Pt전극을, 참고 전극은 칼로멜 전극을 사용하였다. Potential 범위는 2 V에서 4 V로 진행하였고, scan rate는 50 mV/s로 측정하였다. 투과도는 UV/VIS spectrometer로 측정하였다. 전기변색 특성의 상관관계 및 에 대해서는 학회 당일 발표할 예정이다.

  • PDF

Capacitively Coupled SF6, SF6/O2, SF6/CH4 Plasma Etching of Acrylic at Low Vacuum Pressure (저진공 축전결합형 SF6, SF6/O2, SF6/CH4 플라즈마를 이용한 아크릴의 반응성 건식 식각)

  • Park, Yeon-Hyun;Joo, Young-Woo;Kim, Jae-Kwon;Noh, Ho-Seob;Lee, Je-Won
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.68-72
    • /
    • 2009
  • This study investigated dry etching of acrylic in capacitively coupled $SF_6$, $SF_6/O_2$ and $SF_6/CH_4$ plasma under a low vacuum pressure. The process pressure was 100 mTorr and the total gas flow rate was fixed at 10 sccm. The process variables were the RIE chuck power and the plasma gas composition. The RIE chuck power varied in the range of $25{\sim}150\;W$. $SF_6/O_2$ plasma produced higher etch rates of acrylic than pure $SF_6$ and $O_2$ at a fixed total flow rate. 5 sccm $SF_6$/5 sccm $O_2$ provided $0.11{\mu}m$/min and $1.16{\mu}m$/min at 25W and 150W RIE of chuck power, respectively. The results were nearly 2.9 times higher compared to those at pure $SF_6$ plasma etching. Additionally, mixed plasma of $SF_6/CH_4$ reduced the etch rate of acrylic. 5 sccm $SF_6$/5 sccm $CH_4$ plasma resulted in $0.02{\mu}m$/min and $0.07{\mu}m$/min at 25W and 150W RIE of chuck power. The etch selectivity of acrylic to photoresist was higher in $SF_6/O_2$ plasma than in pure $SF_6$ or $SF_6/CH_4$ plasma. The maximum RMS roughness (7.6 nm) of an etched acrylic surface was found to be 50% $O_2$ in $SF_6/O_2$ plasma. Besides the process regime, the RMS roughness of acrylic was approximately $3{\sim}4\;nm$ at different percentages of $O_2$ with a chuck power of 100W RIE in $SF_6/O_2$ plasma etching.

Phosphorescent Organic Light Emitting Diodes using the Emission Layer of (TCTA/$TCTA_{1/3}TAZ_{2/3}/TAZ):Ir(ppy)_3$ ((TCTA/$TCTA_{1/3}TAZ_{2/3}/TAZ):Ir(ppy)_3$ 발광층을 이용한 녹색 인광소자)

  • Jang, J.G.;Shin, S.B.;Shin, H.K.;Kim, W.K.;Ryu, S.O.;Chang, H.J.;Gong, M.S.;Lee, J.Y.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04a
    • /
    • pp.33-35
    • /
    • 2008
  • We have fabricated and evaluated new high efficiency green light emitting phosphorescent devices with an emission layer of $[TCTA_{1/3}TAZ_{2/3}/TAZ]:Ir(ppy)_3$. The whole experimental devices have the basic structure of $2-TNATA(500 {\AA})/NPB(300{\AA})/EML(300{\AA})/BCP(50{\AA})/SFC137(500{\AA})$ between anode and cathode. We have also fabricated conventional phosphorescent devices with emission layers of $(TCTA_{1/3}TAZ_{2/3}):Ir(ppy)_3$ and $(TCTA/TAZ):Ir(ppy)_3$ and compared their electroluminescence characteristics with those of the device with an emission layer of $(TCTA/TCTA_{1/3}TAZ_{2/3}/TAZ):Ir(ppy)_3$. The current density(J), luminance(L), and current efficiency($\eta$) of the device with an emission layer of $(80{\AA}-TCTA/90{\AA}-TCTA_{1/3}TAZ_{2/3}/130{\AA}-TAZ):10%-Ir(ppy)_3$ were 95 $mA/cm^2$, 25000 $cd/m^2$, and 27 cd/A at an applied voltage of 10V, respectively. The maximum current efficiency was 52 cd/A under the luminance of 400 $cd/m^2$. The peak wavelength and FWHM(full width at half maximum) in the electroluminescence spectral were 513nm and 65nm, respectively. The color coordinate was (0.30, 0.62) on the CIE (Commission Internationale de l'Eclairage) chart. Under the luminance of 15000 $cd/m^2$, the current efficiency of the device with an emission layer of $(80{\AA}-TCTA/90{\AA}-TCTA_{1/3}TAZ_{2/3}/130{\AA}-TAZ):10%-Ir(ppy)_3$ was 34 cd/A, which has been improved 1.7 times and 1.4 limes compared to those of the devices with emission layers of $(300{\AA}-TCTA_{1/3}TAZ_{2/3}): 10%-Ir(ppy)_3$ and $(100{\AA}-TCTA/200{\AA}-TAZ):10%-Ir(ppy)_3$, respectively.

  • PDF

Fiber-optic biosensor for the detection of organophosphorus compounds in a contaminated water (Part I. : Design and development) (오염수 내의 유기인 화합물의 측정을 위한 광섬유 바이오센서 (제 1 부 : 장치 설계 및 개발 ))

  • Choi, Jeong-Woo;Min, Jun-Hong;Lee, Won-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.50-56
    • /
    • 1994
  • Fiber-optic biosensor for the detection of organophosphorus compounds in a contaminated water was developed, which was the component of pesticides and agricultural agent. The detection principle of designed sensor was the pH variance induced by a reaction of acetylcholinesterase enzyme inhibited by organophosphorus compounds. The pH variance was detected by the optical system to measure the organophosphorus compounds. Litmus was selected as the pH-sensitive dye suitable to the enzyme reaction and a light source to be detected by the optical system. The enzyme entrapped in Ca-alginate gel was immobilized at the inner wall to maintain the high activity of enzyme and to be reused for a long period. The optical fiber was used to miniaturize and control remotely the sensor system. The He-Ne laser with 632 nm was selected as the light source to prevent light intensity fluctuation by the product. Cheap plastic optical fibers were used as the transmission part of the light and the phototransistor was used as the reception part of light based on the wavelength of He-Ne laser. The proposed fiber-optic biosensor has the linear analytical range of 0 ppm-1.5 ppm with response time of 5 minutes.

  • PDF

Rapid and Simple Analytical Method for Removing Patulin from Apple Juice Using Solid Phase Extraction (고체상 추출법(SPE: Solid Phase Extraction)을 이용한 국내 사과주스 중 Patulin 간편.신속 분석방법)

  • Yim, Jong-Gab;Jang, Hae-Won;Lee, Kwang-Geun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.3
    • /
    • pp.257-262
    • /
    • 2010
  • Patulin, a secondary metabolite of mold, is commonly found in rotten apples. Many countries regulate patulin at levels ranging from 30 to $50\;{\mu}g/L$. Most analytical methods for removing patulin from apple juice include liquid-liquid extraction (LLE), which is time and labor intensive. To replace the LLE method, a solid-phase extraction (SPE) method has been developed for apple juice and unfiltered apple juice. A portion of the test sample was applied to a macroporous copolymer cartridge and washed with 5 mL of 1% sodium bicarbonate, followed by 5 mL of 1% acetic acid. Patulin was eluted with 5 mL of 2% acetonitrile in anhydrous ethyl ether. The mobile phase was tetrahydrofuran in water (0.8:99.2) and was detected with a UV detector at 276 nm. Recoveries ranged from 95 to 101% in test samples, and the minimum detectable level was 30 ppb. Because this SPE method is fast, easy, reliable, and inexpensive, it could be applicable for companies or analytical agencies to analyze patulin concentrations in apple juice.