Effect of liners and primers on tensile bond strength between zirconia and resin-based luting agent

  • Jo, Eun-Hye;Huh, Yoon-Hyuk;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.374-380
    • /
    • 2018
  • PURPOSE. The effect of silica-based glass-ceramic liners on the tensile bond strength between zirconia and resin-based luting agent was evaluated and compared with the effect of 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing primers. MATERIALS AND METHODS. Titanium abutments and zirconia crowns (n = 60) were fabricated, and the adhesive surfaces of the specimens were treated by airborne-particle abrasion. The specimens were divided into 5 groups based on surface treatment: a control group, 2 primer groups (MP: Monobond Plus; ZP: Z Prime Plus), and 2 liner groups (PL: P-containing Liner; PFL: P-free Liner). All specimens were cemented with self-adhesive resin-based luting agent. After 24-hour water storage and thermocycling (5,000 cycles, $5^{\circ}C/55^{\circ}C$), the tensile bond strength was measured using a universal testing machine. Failure mode analysis and elemental analysis on the bonding interface were performed. The data were analyzed using Kruskal-Wallis test, Dunn's post hoc test, and Fisher's exact test. RESULTS. The liner groups and primer groups showed significantly higher tensile bond strengths than that of the control group (P<.05). PFL showed a significantly higher tensile bond strength than the primer groups (P<.05). The percentage of mixed failure was higher in the primer groups than in the control group (P<.001), and all the specimens showed mixed failure in the liner groups (P<.001). A chemical reaction area was observed at the bonding interface between zirconia and liner. CONCLUSION. The application of liner significantly increased the tensile bond strength between zirconia and resin-based luting agent. PFL was more effective than MDP-containing primers in improving the tensile bond strength with the resin-based luting agent.

DENTOFACIAL CHANGES IN CLASS I PROTRUSION PATIENTS TREATED WITH PREMOLAR EXTRACTIONS (제 1 소구치 발치가 수반된 Class I전돌 증례의 치료 전후 변화)

  • Chang, Young-Il;Lee, Yu-Hyun
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.487-495
    • /
    • 1996
  • The purpose of this study was to evaluate the dentofacial characteristics and the fost-treatment dentofacial changes of those treated by four premolar extractions and to investigate the factors affecting extraction decision. The sample consisted of 35 patients (27 females, and 8 males) with no more than 7.0mm crowding, diagnosed as Class I protrusion. Pre-treatment and post-treatment lateral cephalograms were evaluated. Computerized statistical analysis was carried out using SPSS/PC+ program. The results were as follows. 1. There was no significant change in skeletal pattern after treatment while there was significant change in dentoalveolar and soft tissue pattern. 2. In pre-treatment skeletal pattern, a tendency toward vertical discrepancy was found. 3. In pre-treatment dental pattern, interincisal angle was $113.11^{\circ}$, U1 to FH was $117.78^{\circ}$ and L1 to A-Pog was 7.94mm. Pre-treatment upper and lower lip position was 2.88mm and 5.43mm to E line. 4. After treatment, interincisal angle increased $14.46^{\circ}$ and upper and lower lip moved back 2.45mm and 3.2mm to E line.(p<0.001) 5. The EI was 138.71 before treatment and 148.2 after treatment.

  • PDF

ERRORS IN DIGITIZED LATERAL CEPHALOMETRIC RADIOGRAPHY (계수 영상화된 측모 두부방사선 규격사진의 계측오차)

  • Jean Seon-Doo;Cho Bong-Hae;Nah Kunng-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.105-116
    • /
    • 1997
  • The purpose of this study is to evaluate the cephalometric reproducibility in digitized cephalometric radiography by comparing the measurement errors between the remeasured and retaken conventional and digitized lateral cephalometric radiography. The mean of the differences and error percentage of each cephalometric measurement were obtained using 96 lateral cephalometric radiography from 48 patients between the age of 11 and 13. The results were as follows; 1. The repeated measurement group of conventional radiography showed least amount of mean differences while those of the retaken measurement group of digitized image showed largest amount of mean differences in every measurement. 2. The measurements which showed statistically significant difference between the conventional radiography and digitized image were S-Go, Ar-Go, S-Ar-Go and S-sN-sNT in repeated measurement group. 3. The measurements which showed statistically significant difference between the repeated and retaken measurement groups were N-S-Ar, MP-Ll and S-sN-sPog in conventional radiography and S-N, Go-Me and N-A in digitized Image. 4. Large amount of error percentage was shown at A-N-B and N-A in retaken measurement group of conventional radiography and N-S-Ba and A-N-B in retaken measurement group of digitized image. 5. The amount of error percentage at Ar-Go and N-S- Ar in retaken measurement group of conventional radiography and S-N, N-A, S-N-B and N-S-Ba in retaken measurement group of digitized image was more than double than those from remeasured groups.

  • PDF

Charge trapping characteristics of the zinc oxide (ZnO) layer for metal-oxide semiconductor capacitor structure with room temperature

  • Pyo, Ju-Yeong;Jo, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.310-310
    • /
    • 2016
  • 최근 NAND flash memory는 높은 집적성과 데이터의 비휘발성, 낮은 소비전력, 간단한 입, 출력 등의 장점들로 인해 핸드폰, MP3, USB 등의 휴대용 저장 장치 및 노트북 시장에서 많이 이용되어 왔다. 특히, 최근에는 smart watch, wearable device등과 같은 차세대 디스플레이 소자에 대한 관심이 증가함에 따라 유연하고 투명한 메모리 소자에 대한 연구가 다양하게 진행되고 있다. 대표적인 플래시 메모리 소자의 구조로 charge trapping type flash memory (CTF)가 있다. CTF 메모리 소자는 trap layer의 trap site를 이용하여 메모리 동작을 하는 소자이다. 하지만 작은 window의 크기, trap site의 열화로 인해 메모리 특성이 나빠지는 문제점 등이 있다. 따라서 최근, trap layer에 다양한 물질을 적용하여 CTF 소자의 문제점을 해결하고자 하는 연구들이 진행되고 있다. 특히, 산화물 반도체인 zinc oxide (ZnO)를 trap layer로 하는 CTF 메모리 소자가 최근 몇몇 보고 되었다. 산화물 반도체인 ZnO는 n-type 반도체이며, shallow와 deep trap site를 동시에 가지고 있는 독특한 물질이다. 이 특성으로 인해 메모리 소자의 programming 시에는 deep trap site에 charging이 일어나고, erasing 시에는 shallow trap site에 캐리어들이 쉽게 공급되면서 deep trap site에 갇혀있던 charge가 쉽게 de-trapped 된다는 장점을 가지고 있다. 따라서, 본 실험에서는 산화물 반도체인 ZnO를 trap layer로 하는 CTF 소자의 메모리 특성을 확인하기 위해 간단한 구조인 metal-oxide capacitor (MOSCAP)구조로 제작하여 메모리 특성을 평가하였다. 먼저, RCA cleaning 처리된 n-Si bulk 기판 위에 tunnel layer인 SiO2 5 nm를 rf sputter로 증착한 후 furnace 장비를 이용하여 forming gas annealing을 $450^{\circ}C$에서 실시하였다. 그 후 ZnO를 20 nm, SiO2를 30 nm rf sputter로 증착한 후, 상부전극을 E-beam evaporator 장비를 사용하여 Al 150 nm를 증착하였다. 제작된 소자의 신뢰성 및 내구성 평가를 위해 상온에서 retention과 endurance 측정을 진행하였다. 상온에서의 endurance 측정결과 1000 cycles에서 약 19.08%의 charge loss를 보였으며, Retention 측정결과, 10년 후 약 33.57%의 charge loss를 보여 좋은 메모리 특성을 가지는 것을 확인하였다. 본 실험 결과를 바탕으로, 차세대 메모리 시장에서 trap layer 물질로 산화물 반도체를 사용하는 CTF의 연구 및 계발, 활용가치가 높을 것으로 기대된다.

  • PDF

The Improvement and Completion of Outcome index: A new assessment system for quality of orthodontic treatment

  • Hong, Mihee;Kook, Yoon-Ah;Kim, Myeng-Ki;Lee, Jae-Il;Kim, Hong-Gee;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.199-211
    • /
    • 2016
  • Objective: Given the considerable disagreement between the Peer Assessment Rating (PAR) index and the American Board of Orthodontics Cast-Radiograph Evaluation, we aimed to develop a novel assessment system-the Improvement and Completion of Outcome (ICO) index-to evaluate the outcome of orthodontic treatment. Methods: Sixteen criteria from 4 major categories were established to represent the pretreatment malocclusion status, as well as the degree of improvement and level of completion of outcome during/after treatment: dental relationship (arch length discrepancy, irregularity, U1-SN, and IMPA); anteroposterior relationship (overjet, right and left molar position, ANB); vertical relationship (anterior overbite, anterior open-bite, lateral open-bite, SN-MP); and transverse relationship (dental midline discrepancy, chin point deviation, posterior cross-bite, occlusal plane cant). The score for each criterion was defined from 0 or -1 (worst) to 5 (ideal value or normal occlusion) in gradations of 1. The sum of the scores in each category indicates the area and extent of the problems. Improvement and completion percentages were estimated based on the pre- and post-treatment total scores and the maximum total score. If the completion percentage exceeded 80%, treatment outcome was considered successful. Results: Two cases, Class I malocclusion and skeletal Class III malocclusion, are presented to represent the assessment procedure using the ICO index. The difference in the level of improvement and completion of treatment outcome can be clearly explained by using 2 percentage values. Conclusions: Thus, the ICO index enables the evaluation of the quality of orthodontic treatment objectively and consecutively throughout the entire treatment process.

Ultra-low-power DSP for Audio Signal Processing (오디오 신호 처리를 위한 초저전력 DSP 프로세서)

  • Kwon, Kiseok;Ahn, Minwook;Jo, Seokhwan;Lee, Yeonbok;Lee, Seungwon;Park, Young-Hwan;Kim, Sukjin;Kim, Do-Hyung;Kim, Jaehyun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2014.06a
    • /
    • pp.157-159
    • /
    • 2014
  • In this paper, we introduce SlimSRP, an ultra-low-power digital signal processor (DSP) solution for mobile audio and voice applications. So far, application processors (APs) have taken charge of all the tasks in mobile devices. However, they have suffered from short battery life problems to deal with complex usage scenarios, such as always-on voice trigger with continuous audio playback. From extensive analysis of audio and voice application characteristics, SlimSRP is designed to relive the performance and power burden of APs. It employs three-issue VLIW architecture, and the major low-power and high-performance techniques include: (1) an optimized register-file architecture friendly for constants generation, (2) a powerful instruction set to reduce the number of register file accesses and (3) a unique instruction compression scheme that contributes to saved memory size and reduced cache miss. An implementation of SlimSRP runs at up to 200MHz and the logic occupies 95K NAND2 gates in Samsung 28LPP process. The experimental results demonstrate that a MP3 decoder application with a 128kbps 44.1kHz input can run at 5.1MHz and the logic consumes only 22uW/MHz.

  • PDF

Effect of Paraspinal Muscle Fatigue on Proprioception and Coordination of the Lower Limb (부척추근의 근피로가 하지의 고유수용성 감각과 협응 능력에 미치는 영향)

  • Park, Min-Chull;Kim, Hyoung-Su;Lee, Sang-Youl;Lee, Myoung-Hee;Goo, Bong-Oh;Yoon, Chang-G
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.4
    • /
    • pp.255-260
    • /
    • 2008
  • Purpose : This study was performed to find out the influence of the change on proprioception and coordination of the lower limb by experimentally induced paraspinal muscle fatigue, Methods : Twelve subjects(6 males, 6 females) with no history low back and lower limbs problem volunteered for this study. Subjects were pre-tested proprioception and coordination using the MR-FSS(Mornitored Rehab Functional Squat System). And then the subjects performed isometric paraspinal muscles contraction for induced muscle fatigue. Muscle fatigue was defined surface EMG(MP 150). After isometric contraction, the subjects were post-tested using the MR-FSS. Results : In comparison of coordination, deviation of concentric coordination was increased(from $0.50{\pm}0.13cm$ to $0.67{\pm}0.21$)(p<0.05) and deviation of eccentric coordination was also increased(from $0.51{\pm}0.15cm$ to $0.70{\pm}0.26cm$)(p<0.05). And deviation movement of proprioceptive test was increased(from $4.98{\pm}1.80cm$ to $5.69{\pm}1.98cm$), but there was no significant different(p>0.05). Conclusion : Fatigue of paraspinal muscles was decreased concentric and eccentric coordination of the lower limb.

  • PDF

Hand Tracking and Hand Gesture Recognition for Human Computer Interaction

  • Bai, Yu;Park, Sang-Yun;Kim, Yun-Sik;Jeong, In-Gab;Ok, Soo-Yol;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.2
    • /
    • pp.182-193
    • /
    • 2011
  • The aim of this paper is to present the methodology for hand tracking and hand gesture recognition. The detected hand and gesture can be used to implement the non-contact mouse. We had developed a MP3 player using this technology controlling the computer instead of mouse. In this algorithm, we first do a pre-processing to every frame which including lighting compensation and background filtration to reducing the adverse impact on correctness of hand tracking and hand gesture recognition. Secondly, YCbCr skin-color likelihood algorithm is used to detecting the hand area. Then, we used Continuously Adaptive Mean Shift (CAMSHIFT) algorithm to tracking hand. As the formula-based region of interest is square, the hand is closer to rectangular. We have improved the formula of the search window to get a much suitable search window for hand. And then, Support Vector Machines (SVM) algorithm is used for hand gesture recognition. For training the system, we collected 1500 hand gesture pictures of 5 hand gestures. Finally we have performed extensive experiment on a Windows XP system to evaluate the efficiency of the proposed scheme. The hand tracking correct rate is 96% and the hand gestures average correct rate is 95%.

Tumoral Calcinosis of the Foot - MRI & Histologic Findings; Two Cases Report - (족부의 종양성 석회증 -자기 공명 영상 및 조직학적 소견의 2예 증례 보고-)

  • Choi, Woo-Sung;Ji, Jong-Hun;Lee, Yeon-Soo;Shafi, Mohamed;Choi, Kwang-Young;Kim, Won-Yoo;Oh, Sae-Cheal
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.213-217
    • /
    • 2004
  • Tumoral calcinosis is rarely encountered disease, and most of reported cases involved large joints such as hip or elbow. We report two patients with tumoral calcinosis in the foot. In the 1st case, the lesion was observed at the 1st MP joint of foot, and in the 2nd case it was found at the DIP joint of 5th toe area with bony erosion which is rare in other tumoral calcinosis. They all needed evaluation with MRI, and eventually surgical excision.

  • PDF

Feasibility and Safety of Single-Port Video-Assisted Thoracic Surgery for Primary Lung Cancer

  • Heo, Woon;Kang, Do Kyun;Min, Ho-ki;Jun, Hee Jae;Hwang, Youn-Ho
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.190-196
    • /
    • 2017
  • Background: The feasibility of single-port video-assisted thoracic surgery (SPVATS) for primary lung cancer is not well understood. In this study, we compared SP and multi-port (MP) VATS for the surgical treatment of patients with primary lung cancer. Methods: Surgical treatment was performed in 181 patients with primary lung cancer at Inje University Haeundae Paik Hospital between June 2012 and December 2015. A propensity-matched analysis was used to compare the postoperative outcomes and to evaluate the comparative feasibility and safety of SPVATS and MPVATS. Results: There were 37 patients in the SPVATS group and 67 patients in the MPVATS group. Propensity matching produced 32 pairs. The operation time (210 minutes versus 200 minutes, p=0.11), volume of the estimated blood loss (170 mL versus 160 mL, p=0.19), duration of chest tube drainage (5 days versus 6 days, p=0.66), and length of hospital stay (9 days versus 10 days, p=0.89) were similar between the 2 groups. Conclusion: In our study, SPVATS for primary lung cancer was safe and feasible in well selected patients. A prospective, randomized study with a large group and long-term follow-up is necessary to evaluate the clinical feasibility and the advantages of SPVATS for primary lung cancer.