• Title/Summary/Keyword: 5-HD

Search Result 429, Processing Time 0.034 seconds

Case Studies of Exposures to Humidifier Disinfectant in Hospitals: Focusing on the Exposure Assessment of the Fourth Round of Applicants (병원에서의 가습기살균제 노출 사례 연구: 4차 가습기살균제 피해 신청자를 중심으로)

  • Han, Kyunghee;Yoon, Jeonggyo;Jo, Eun-Kyung;Ryu, Hyeonsu;Yang, Wonho;Choi, Yoon-Hyeong
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.4
    • /
    • pp.358-369
    • /
    • 2019
  • Objective: This study aimed to introduce cases of exposure to humidifier disinfectant (HD) in hospitals and to present their exposure characteristics. Methods: We used data from 4,393 subjects who participated in the fourth assessment survey of environmental exposure to HD conducted by the Korea Environmental Industry & Technology Institute. In this study, we selected 301 subjects who reported their place of use of HD as a hospital. Then, we classified cases as 'Hospital-provided'. 'Probably hospital-provided', 'Individual purchased', and 'Unknown' according to the supply sources of HD. Also, we introduced detailed exposure characteristics for the selected cases. Results: Of the 4,393 subjects, 301 (6.9%) reported the use of HD in 392 hospitals (including duplicate answers for the use in ${\geq}2$ hospitals). The 301 hospital-user subjects included 139 survivors and 162 non-survivors. When we classified the 392 cases by supply sources, 'Hospital-provided' was 12.2% (48 cases), 'Probably hospital-provided' was 25.5% (100 cases), 'Individual purchased' was 59.7% (234 cases), and 'Unknown' was 2.6% (10 cases). Among the 'Hospital-provided' cases, we selected six cases and provided a detailed description of the HD use in this study. Additionally, we reported details for six cases that had purchased HD upon a doctor or nurse's recommendation and for three cases that had purchased it at hospital stores. Conclusion: This study presents various cases of HD exposure in hospitals. Because there may be a considerable burden of HD exposure in public spaces, including hospitals, further studies are necessary to assess HD exposure in hospitals and public places.

Integration of Uncompressed HD Video Transport System and Network-based Tiled Display (비압축 HD 비디오 전송 시스템과 네트워크 기반 타일드 디스플레이의 결합)

  • Park, Jong-Churl;Chae, Jong-Kwon;Choi, Ki-Ho;Kim, Jong-Won;Jo, Jin-Yong;Kwak, Jai-Seung
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.06a
    • /
    • pp.277-281
    • /
    • 2007
  • 광 기반 네트워크 기술의 발전에 따라 Gbps 급의 대역폭을 요구하는 비입축 HD (high definition) 영상을 낮은 지연으로 전송하고 재생하는 것이 가능해지고 있다. 이를 위하여 다양한 비압축 HD 미디어 전송 시스템이 소개되어 왔으며, 이들은 일반적으로 RTP(Real-time Transport Protocol)에 기반으로 한 실시간 데이터 전송과 비압축 미디어 인터페이스를 효과적으로 결합하여 대화형으로 사용함에도 지장이 없는 저지연의 실감형 시스템을 지원하고 있다. 본 논문에서는 [4,5]에서 제안된 비압축 HD 미디어 시스템의 실감성을 향상시키기 위하여 9600 $\times$ 4800 해상도의 타일드 디스플레이를 통해 전송된 비압축 HD 영상을 재생할 수 있는 기법을 제시한다. 또한 실제 구현된 비압축 HD 영상과 타일드 디스플레이 간의 연동 실험을 통하여 제안된 결합 방식의 타당성을 확인하고, 그 결과로 얻어진 실감성 있는 미디어 서비스의 효용성을 입증한다.

  • PDF

Development and transcription estimation of an automotive interior plastic part(HD Switch Panel) with no glossy etching pattern (무광부식 패턴을 갖는 자동차 내장부품인 HD Switch Panel의 제조 및 전사성 평가)

  • Kim, Young-Kyun;Kim, Dong-Hak;Son, Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3280-3286
    • /
    • 2009
  • In this paper, we designed and manufactured HD Switch Panel parts with micro-etched pattern. By using CAE analysis, we could predict weld-line positions and the amount of shrinkage during injection molding process. We measured the temperature distribution of the mold surface so that we could optimize the processing conditions such as mold temperature. In order to increase the transcription of micro-etched pattern, we applied the E-Mold technology and evaluated the effect of mold temperature on the surface quality. We concluded that the etched pattern was improved(more than 2.5$\to$1.5~1.7) through the measurement of surface gloss and the observation of both SEM and SPM images.

Introduction and feasibility study of the HD-270 MLC (HD-270 MLC의 소개 및 유용성평가)

  • Kim Dae Young;Kim Won Taek;Lee Hwa Jung;Lee Kang Hyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • I. Purpose The multileaf collimator(MLC) has many advantages, but use of the MLC increased effective penumbra and isodose undulation in dose distribution compared with that of an alloy block. In this work, we introduced the HD-270 MLC, which can improve the above disadvantages of MLC, and reported its feasibility study. II. Method and Materials The HD-270 MLC is a technique which combines the use of the existing Siemens multileaf collimator(3D MLC) with patient translation perpendicular to the leaf plane. The technique produces a smoothed isodose distribution with the reduced isodose undulation and effective penumbra. To assess the efficacy of the HD-270 technique and determine the appropriate resolution, a polygonal shaped MLC field was made to produce field edge angles from 0 degree to 75 degree with a step of 15 degree. Each HD-270 group was generated according to the allowed resolution, i. e., 5, 3, and 2mm. The experiment was carried out on Primus, a Siemens linear accelerator configured with HD-270 MLC. The total 60 MU of 6 MV photon beam was delivered to X-Omat film(Kodak, USA) at a SAD of 100 cm and 1.5 cm depth in solid water phantom. Exposed films were scanned by Lumiscan75(LUMISYS) and analyzed using RIT113 software(Radiological Imaging Technology Inc., USA). To test the mechanical accuracy of table movement, the transverse, longitudinal, and vertical positions were controlled by a consol with ${\pm}5\;mm,\;{\pm}4\;mm,\;{\pm}3\;mm,\;and\;{\pm}2\;mm$ steps, and then measured using a dial gauge with an accuracy of 0.001 inch. During the experiments, the table loaded with about 50Kg human phantom to simulate the real treatment situation. III. Results The effective penumbra and isodose undulation became larger with increase the resolution and field edge angle. The accuracy of the table movement on each direction is good within the ${\pm}1\;mm$. IV. Conclusion Clinical use of the MLC can be increased by using of the HD-270 MLC which complements to the disadvantages of the MLC.

  • PDF

Development and transcription estimation of an automotive interior plastic part(HD Switch Panel) with no glossy etching pattern (무광부식 패턴을 갖는 자동차 내장부품인 HD Switch Panel의 제조 및 전사성 평가)

  • Kim, Young-Kyun;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.870-873
    • /
    • 2009
  • 본 연구에서는 미세 무광부식 패턴을 갖는 HD Switch Panel 부품을 설계하고 금형을 제작하였다. 이를 위하여 사출성형 Simulation(CAE)을 이용하여 사출성형 공정의 문제점과 부품의 변형량을 예측 하였다. 또한 금형표면의 가열온도와 실제 금형온도의 비교함으로써 공정변수 조절을 통한 사출성형 조건의 최적화를 달성할 수 있었다. 한편, 순간금형표면가열을 이용한 성형기술인 E-MOLD를 적용하여 자동차 내장부품용 HD Switch Panel을 제작하였고, 전자현미경과 원자현미경을 이용한 표면 평가를 통하여 무광부식 패턴의 전사율 향상으로 인한 무광 특성이 향상됨(2.5이상$\rightarrow$1.5~1.7)을 확인하였다.

  • PDF

Study on the Effects of Hydrogen Decrepitation on the Formation of Sm2Fe17Nx-type Material

  • Kwon, H.W
    • Journal of Magnetics
    • /
    • v.4 no.2
    • /
    • pp.55-59
    • /
    • 1999
  • In an attempt to find an effective production way of the$ Sm_2Fe_{17}N_{x-}type material, the Sm_2Fe_{17-}$type alloy with chemical composition of Sm 22.7 wt.%, Fe72.3 wt.% Nb 5.0wt.% was subjected to a HD (hydrogen decrepitation) treatment prior to a nitrogenation, and its effect on the formation of the nitride material was investigated. The nitrogenation behaviours of the alloy were investigated using a TPA(thermopiezic analysis), TMA, and DTA under nitrogen gas, and XRD. It has been found that the previous HD treatment significantly facilitated the formation of $Sm_2Fe_{17}N_{x-}$type nitride, and this was accounted for by the clean surface and the finer particle size of the powder caused by the HD treatment. It has also been found that the hydrogen atoms existing in the initial HD-treated alloy were removed almost completely during the nitrogenation. The heat output associated with the nitrogenation of the previously HD-treated alloy was found to be significantly smaller than that of the as-cast alloy.

  • PDF

Design and Implementation of 5G mmWave LTE-TDD HD Video Streaming System for USRP RIO SDR (USRP RIO SDR을 이용한 5G 밀리미터파 LTE-TDD HD 비디오 스트리밍 시스템 설계 및 구현)

  • Gwag, Gyoung-Hun;Shin, Bong-Deug;Park, Dong-Wook;Eo, Yun-Seong;Oh, Hyuk-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.445-453
    • /
    • 2016
  • This paper presents the implementation and design of the 1T-1R wireless HD video streaming systems over 28 GHz mmWave frequency using 3GPP LTE-TDD standard on NI USRP RIO SDR platform. The baseband of the system uses USRP RIO that are stored in Xilinx Kintex-7 chip to implement LTE-TDD transceiver modem, the signal that are transceived from USRP RIO up or down converts to 28 GHz by using self-designed 28 GHz RF transceiver modules and it is finally communicated HD video data through self-designed $4{\times}8$ sub array antennas. It is that communication method between USRP RIO and Host PC use PCI express ${\times}4$ to minimize delay of data to transmit and receive. The implemented system show high error vector magnitude performance above 25.85 dBc and to transceive HD video in experiment environment anywhere.

Improvement of catheter-related outcomes after application of tunneled cuffed hemodialysis catheter insertion without fluoroscopy

  • Kang, Seok Hui;Do, Jun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.3
    • /
    • pp.186-193
    • /
    • 2020
  • Background: Non-tunneled catheters (NTCs) are used for hemodialysis (HD) in many centers in which fluoroscopy is not easily accessed despite high complication rates and conditions requiring long-term HD. Therefore, here we aimed to evaluate the superiority of catheter-related outcomes after the application of tunneled cuffed catheter (TCC) without fluoroscopy versus unconditioned NTC insertion. Methods: We divided the participants into two phases: those receiving NTCs between March 2010 and February 2011 (phase I), and those receiving TCCs or NTCs between March 2011 and February 2012 (phase II). Catheter survival, nurse satisfaction, and reasons for catheter removal were analyzed. Results: Two hundred and sixty patients in phase I and 300 patients in phase II were enrolled in this study. The success rate of TCC insertion was 99.2%. The catheter survival rate in phase I was 65.5% at 1 month, while that in phase II was 74.9% at 1 month (p=0.023). We compared catheter survival between TCCs and NTCs for all periods regardless of phase. The TCC survival rate was higher than the NTC survival rate (p<0.001). Catheter-associated problems led to catheter removal in 97 patients (26.6%) in phase I and 68 patients (18.5%) in phase II (p=0.009). Among 14 HD nurses, all reported being satisfied with manipulation during pre-/post-HD, manupulation during HD, and overall. Eleven HD nurses (78.6%) reported being satisfied with the workload. Conclusion: Compared with unconditional NTC insertion for HD, TCC insertion without fluoroscopy improved the overall catheter survival and nurse satisfaction rates.

Genistein Combined with Exercise Improves Lipid Profiles and Leptin Levels in C57BL/6J Mice Fed a High Fat Diet

  • Seong, So-Hui;Ahn, Eun-Mi;Sohn, Hee-Sook;Baik, Sang-Ho;Park, Hyun-Woo;Lee, Sang-Jun;Cha, Youn-Soo
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.910-917
    • /
    • 2007
  • The aim of this study is to determine the anti-obesity effects of genistein and exercise, separately and in combination, in mice. Fifty male C57BL/6J mice were divided into 5 treatment groups: normal diet (ND), high fat diet (HD), high fat diet with exercise (HD+Ex), high fat diet with 0.2% genistein (HD+G), high fat diet with 0.2% genistein, and exercise (HD+G+Ex). They were allowed free access to feed and water, and exercised mice engaged in swimming on a regular basis for 12 weeks. Genistein supplemented mice gained less weight, had lower energy intake, better lipid profiles, and lower leptin than the HD mice. Furthermore, when genistein was combined with exercise (HD+G+Ex) the effects were even greater. HD, HD+Ex, and HD+G mice exhibited increased hepatic CPT-1 mRNA expression. Therefore, genistein and exercise has anti-obesity effects, as shown by changes in body weight, fat accumulation, energy intake, and leptin levels.

Comparative Studies of Five Solvents for the Extraction of Polar Lipid in Corn Embryo (옥수수 배의 극성 지질의 추출을 위한 5종 용매의 비교연구)

  • 김덕진;전영민
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.20 no.6
    • /
    • pp.590-595
    • /
    • 1991
  • In order to investigate polar lipid ingredients and fat쇼 acid compositions in corn embryo, lipids were extracted with n-hexane (HX), pet. ether (PE), chloroform-methanol (2:1, v/v) (CM), dichoromethane-methanol (2:1, v/v DM) and hexane-diethyl ether (5:1, v/v HD). Of the glycolipid in polar lipids were separated by thin layer chormatogarphy (TLC), monoglycosyl diacyglycerol was most efficient with CM, HD, and monoglycosy sterol and monoglycosyl ceramide were similar to five solvents, but HX, PE and DM, HD were somewhat superior, respectively. Of the phospholipid, phosphatidyl inositol was most efficient with CM, DM, and phosphatidyl choline was similar to five solvents as well. Phosphatidyl serine was superior PE, HD, CM to HX, and phosphatidyl ethanolamine was inferior CM to HX. The major fatty acid in the glycolipid was linoleic acid, and it was most efficient with CM the same as plamitic acid, but oleic acid was superior in using HX, PE. The major fatty acids in the phospholipid were palmitic, heptadecanoic aicds, and they were superior in using HX and PE, respectively. Also oleic acid was most efficient with HX and CM, but HD was somewhat inferior.

  • PDF