• Title/Summary/Keyword: 5 empirical formulas

Search Result 46, Processing Time 0.026 seconds

Estimation of Hourly Emission Flux of Asian Dust Using Empirical Formulas in the Source Area (경험식을 이용한 발원지 황사의 시간별 발생량 추정)

  • Moon, Yun-Seob;Lee, Seong-Hwan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.539-549
    • /
    • 2009
  • The purpose of this study is to estimate hourly Asian dust emission flux in springtime by using the optimized Weather Research Forecasting model (WRF) in order to accurately predict the horizontal flux of Asian dusts. Asian dust emission flux using 5 empirical formulas such as US EPA, Park and Inn, Wang, The Goddard Chemistry Aerosol Radiation and Transport (GOCART) and Dust Entrainment and Deposition (DEAD) were calculated and compared by using classified land-use types and size distribution at various locations in China and Mongolia together with the hourly meteorological elements of the WRF model. As a result, the empirical formula in US EPA among them, which was considered the various conditions such as vegetation, soil type and terrain, was better than the other 4 empirical formulas. However, these formulas were adjusted hourly and vertically in time and space because there was different order and time resolution of dust emissions from original empirical formulas.

Across-wind dynamic loads on L-shaped tall buildings

  • Li, Yi;Li, Qiu-Sheng
    • Wind and Structures
    • /
    • v.23 no.5
    • /
    • pp.385-403
    • /
    • 2016
  • The across-wind dynamic loads on L-shaped tall buildings with various geometric dimensions were investigated through a series of wind tunnel testing. The lift coefficients, power spectral densities and vertical correlation coefficients of the across-wind loads were analyzed and discussed in details. Taking the side ratio and terrain category as key variables, empirical formulas for estimating the across-wind dynamic loads on L-shaped tall buildings were proposed on the basis of the wind tunnel testing results. Comparisons between the predictions by the empirical formulas and the wind tunnel test results were made to verify the accuracy and applicability of the proposed formulas. Moreover, a simplified procedure to evaluate the across-wind dynamic loads on L-shaped tall buildings was derived from the proposed formulas. This study aims to provide a simple and reliable way for the estimation of across-wind dynamic loads on L-shaped tall buildings.

Prediction of Stability Number for Tetrapod Armour Block Using Artificial Neural Network and M5' Model Tree (인공신경망과 M5' model tree를 이용한 Tetrapod 피복블록의 안정수 예측)

  • Kim, Seung-Woo;Suh, Kyung-Duck
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.109-117
    • /
    • 2011
  • It was calculated using empirical formulas for the weight of Tetrapod, which was a representative armor unit in the rubble mound breakwater in Korea. As the formulas were evaluated from a curve-fitting with the result of hydraulic test, the uncertainty of experimental error was included. Therefore, the neural network and M5' model tree were used to minimize the uncertainty and predicted the stability number of armor block. The index of agreement between the predicted and measured stability number was calculated to assess the degree of uncertainty for each model. While the neural network with the highest index of agreement have an excellent prediction capability, a significant disadvantage exists that general designers can not easily handle the method. However, although M5' model tree has a lower prediction capability than the neural network, the model tree is easily used by the designers because it has a good prediction capability compared with the existing empirical formula and can be used to propose the formulas like an empirical formula.

Hydrological Review on the Fload Runoff ratio (홍수유출율에 관한 수문학적 고찰)

  • 이순혁;음성진;박명근
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.27 no.4
    • /
    • pp.42-52
    • /
    • 1985
  • This study was attempted to derivate empirical formulas for the runoff: ratio during ilood. season at three watersheds of Dan Yang, Chung Ju, and Yeo Ju are located at upper, middle, and lower portion of Nam Han river basin, respectively. Obtained formulas for flood runoff ratio can be applied as an element for the estimation, peak discharge for the design of various hydraulics structures which can be concidented with meteorological and topographical condition. The obtained through this study were analyzed as follows. 1.It was found that the magnitude of runoff ratio depends on the amount of rainfall for all studying basins. 2.Empirical formulas 'for the runoff' ratio were derivated as 1- 2,707 Rt0.345, 1-1.691 Rt0.242 and 1-1.807 Rt0.227 at Dan Yang, Chung Ju and Yeo Ju watershed, respectively. 3.The magnitude of runoff ratio was appeared in the order of Dan Yang, Chung Ju, and Yeo Ju are located at upper, middle and lower portion of Nam Han rivet basin, respectively. 4.It was assumed that in general the more it rains, the lesser becomes the ratio of loss rainfall. Especially, the ratio of loss rainfall for Dan Yang, upper portion of river basin was shown as the lowest among three watersheds. Besides, the magnitude of that was appeared in the order of Chung Ju and Yeo Ju watershed located at middle, and lower part of river basin, respectively. 5.Relative and standard errors of runoff ratio calculated by empirical formulas were shown to be within ten percent to the observed runoff ratio in all watersheds. 6.It is urgently essential that the effect of antecedent rainfall have an influence on the next coming flood should be studied in near future.

  • PDF

Evaluation and Adjustment of Dynamic Pile-Driving Formulas (말뚝 지지력 산정을 위한 동역학적 공식의 정확도 분석 및 수정)

  • Chung, Choong Ki;Kim, Myoung Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.4
    • /
    • pp.23-30
    • /
    • 1985
  • Dynamic pile-driving formulas are widely used in predicting the load capacity of piles in cohesionless soils. However, the accuracy of the formulas has been questioned for a long time due to their oversimplified assumptions and empirical parameters involved in the formulas. The allowable pile capacities calculated by 6 different dynamic pile-driving formulas are compared statistically with the capacities measured in the field, in this paper, to find out the correlations between the calculated capacities and the measured values. The statistical data are then used to evaluate and to adjust the formulas to improve their accuracy. For the greatest accuracy and simplicity of use, it is recommended that the adjusted form of Gates formula be used. When the result of this recommended formula is compared with that of the existing Olson's modified formula, the former is found to be conservative by more than 10 percents.

  • PDF

Estimation of Head Loss Coefficient Empirical Formulas Using Model Experimental Results in a 90° Angle Dividing Channel Junction (90도 각도를 갖는 분기수로에서 모형실험결과를 이용한 손실계수 경험식 산정)

  • Park, Inhwan;Seong, Hoje;Kim, Hyung-Jun;Rhee, Dong Sop
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.6
    • /
    • pp.989-999
    • /
    • 2017
  • In this study, hydraulic experimental studies were conducted to estimate the empirical formulas of loss coefficient, which is necessary to calculate the energy loss occurred in the dividing channel junction of sewer system. The experimental apparatus was consisted of two outflow conduit with a $90^{\circ}$ angle to the inlet conduit, and the pressure and velocity heads are measured to analyze the energy losses in the branch. The measurements of the hydraulic grade line show that the hydraulic grade line was steeply descended at the dividing point due to the head loss, and the decreasing amount of velocity head increased with the increase of flowrate ratio. The head loss exponentially increased in the outlet with larger runoff as the increase of flowrate ratio and Froude number, and the head loss coefficient also increased. On the other hands, the head loss coefficients decreased in the outlet with smaller runoff as the increase of the flowrate ratio and Froude number. Using the experimental results, the empirical formulas of loss coefficient was suggested for each outlet, and the error of empirical formula was 3.91 and 5.19%, respectively. Furthermore, the total head loss coefficient calculated by the two empirical formulas was compared with the experimental results, and the error was 3.62%.

Study on the Confidential Document of A Distinguished Medical Family (기문비록(岐門秘錄)에 대한 고찰)

  • Kim, Dong-Min;Choi, Kyung-Suk;Shin, Seung-Yuel;Ahn, Jun-Mo;Keum, Kyung-Soo;Lee, Si-Hyeong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.5
    • /
    • pp.1078-1105
    • /
    • 2008
  • An empirical formula that has been empirically shown to be effective for a particular condition can be said to add medicinal materials to an existing formula or to make a new prescription by the Korean medical doctors' empirical clinic. This dissertation aims to study the prescriptions according to A Confidential Document of A Distinguished Medical Family written by the writer's ancestor and to contribute to the development of Korean medicine. A Confidential Document of A Distinguished Medical Family is a medicinal recipe that is an heirloom of the Gyeongju Kim family for the eighth generation. And the date and the writer of the book are unknown. The contents of the book consist of 18 parts and are made up of about 300 medical recipes. Of these, 158 formulas and indications of cold damage, wind, urination, stool, jaundice, and internal injury are found in the book. From among these, 61 formulas was directly quoted out of The Precious Mirror of Oriental Medicine, 97 formulas are adjusted in proportion or combined. By the parity of reasoning of the above, I think that this book was published after The Precious Mirror of Oriental Medicine. I will continue to study other formulas except the formulas above mentioned.

Dynamic Increase factor based on residual strength to assess progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.25 no.5
    • /
    • pp.617-624
    • /
    • 2017
  • In this study, a new empirical method is presented to obtain Dynamic Increase Factor (DIF) in nonlinear static analysis of structures against sudden removal of a gravity load-bearing element. In this method, DIF is defined as a function of minimum ratio of difference between maximum moment capacity ($M_u$) and moment demand ($M_d$) to plastic moment capacity ($M_p$) under unamplified gravity loads of elements. This function determines the residual strength of a damaged building before amplified gravity loads. For each column removal location, a nonlinear dynamic analysis and a step-by-step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived, which correspond to the ratio min $[(M_u-M_d)/M_p]$ of beams in the bays immediately adjacent to the removed column, and at all floors above it. Therefore, the new DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of a moment frame structure. The proposed DIF formulas can estimate the real residual strength of a structure based on critical member.

Efficient Prediction of Aerodynamic Heating of a High Speed Aircraft for IR Signature Analysis (적외선 신호 분석을 위한 고속 항공기의 공력가열에 관한 효율적 예측)

  • Lee, Ji-Hyun;Chae, Jun-Hyeok;Ha, Nam-Koo;Kim, Dong-Geon;Jang, Hyun-Sung;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.11
    • /
    • pp.768-778
    • /
    • 2019
  • The ability to calculate aerodynamic heating and surface temperature is essential to ensure proper design of aircraft components in high speed flight. In this study, various empirical formulas for efficiently calculating aerodynamic heating of aircraft were first analyzed. A simple computational code based on empirical formulas was developed and then compared with commercial codes; ANSYS FLUENT based on the Navier-Stokes-Fourier equation, and ThermoAnalytics MUSES based on an empirical formula. The code was found to agree well with the results of FLUENT in the wall and stagnation point temperatures. It also showed excellent agreement with MUSES, within 1% and 5% in temperature and heat flux, respectively.

Study on Numerical-analysis Technique for Windpower System Structure under Environmental Loadings (환경하중하의 풍력발전 시스템 구조물의 수치 해석적 기법 연구)

  • Jung, Hae-Young;Hong, Cheol-Hyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.69-75
    • /
    • 2011
  • The purpose of this study was to develop a buckling analysis technique for a windpower system structure under environmental loadings (hydrostatic pressure) using FEM. We analyzed an isotropic material and composite material and made a comparison using buckling pressure formulas. First, finite element analyses for an isotropic material (SC410) were performed to obtain the variation of buckling pressure for the number of elements and boundary conditions in a pressure-shell model, and the numerical results were compared with those of existing empirical formulas. Then, additional finite element analyses based on the results of the isotropic material (SC410) were performed to determine the optimum lamination angle and pattern for a composite material (URN300). The results of the FE analyses for the composite material were also compared with those of existing empirical formulas. The ply orientations (lamination angles) used in the FE analyses were $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $75^{\circ}$, and. The lamination patterns in the FE analyses were and. The lamination pattern was assumed to be the equivalent model of. The results of the FE analyses for the isotropic material (SC410) indicated that the optimal values for the number of elements and the boundary conditions were 6000 and both simply supported, respectively. The results of the FE analyses for the composite material (URN300) showed that the optimal ply orientation was $60^{\circ}{\sim}75^{\circ}$.