• Title/Summary/Keyword: 5대 건물에너지

Search Result 26, Processing Time 0.026 seconds

A Study on the BEMS Installation and performance Evaluation Method for Energy Monitoring(Measuring) of New Building (신축건물 에너지효율관리를 위한 환경 및 에너지모니터링(계측) 방법론)

  • Kwon, Won Jung;Yoon, Ji Hye;Kwon, Dong Myung
    • Journal of Energy Engineering
    • /
    • v.27 no.2
    • /
    • pp.32-48
    • /
    • 2018
  • Monitoring of energy use should be a priority in order to efficiently manage building energy use. Energy use in buildings can be managed by dividing them into energy sources, uses, and ZONE. By energy source, electricity, gas, fuel, and district heating are supplied to run the building's facilities. The purpose can be divided into five main applications, including cooling, heating, lighting, hot water and ventilation, but not many elevators and electric heaters that are difficult to include in the five applications are classified. ZONE Star refers to the comparison or separate management of areas for which the purpose of the building is similar or different. In addition, energy efficiency management requires control of the temperature, humidity, and people who will be measuring energy in the building, and the recent problem of fine dust should directly affect the ventilation of the building.

A Study on the Safety Performance Evaluation Method of Blowers for 1kW Class Stationary Fuel Cell System (1kW급 건물용 연료전지시스템 블로워의 안전성능 평가방법에 관한 연구)

  • Lee, Jungwoon;Seo, Wonseok;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.127.2-127.2
    • /
    • 2010
  • 우리나라는 기후변화 대응을 준비하기위해 2008년도에 수립한'국가에너지기본계획(2008-2030)'에 따라 2030년까지 신재생에너지 비중을 2.4%에서 11%까지 달성을 목표로 정하고 신재생에너지 분야를 성장시키기 위해 국가기술개발 및 산업화 전략을 수립해 추진하고 있다. 이에 발맞추어 건물용 연료전지시스템의 경우, 2006년도부터 1kW급 가정용 연료전지시스템 모니터링 사업의 일환으로 3년간 210대가 도시가스사 및 지자체 등을 중심으로 설치되어 운전되어지고 있다. 특히, 2010년부터 시범보급사업이 추진되어 올해 200대를 시작으로 2011년에 300대, 2012년에 500대가 일반가정에 보급되어질 예정이다. 하지만 현재 6천만원인 연료전지시스템 가격을 실제 보급가능한 가격인 5백만원 이하로 저감시키는 것이 현 시점에서 가장 시급한 문제로 대두되어지고 있는 실정이다. 본 연구에서는 그린홈 보급확대를 위한 건물용 연료전지의 보조기기인 블로워의 가격저감을 위한 연구의 일환으로 블로워의 안전성능 평가방법을 개발하여 보조기기의 가격저감 및 안전성을 확보하고자 한다. 1kW급 건물용 연료전지시스템의 여러 블로워 중 도시가스용 연료승압 블로워, 선택산화 공기 블로워, 버너 공기 블로워 및 캐소드 공기 블로워의 안전성능 평가방법을 제시함으로서, 국내 블로워 제조사의 설계방향을 제시하고 연료전지시스템의 안전성을 확인하고자 한다. 특히, 내구성, 기밀, 가혹조건시험 및 소음, 진동, 습도, 온도와 같은 내주위환경시험 등의 평가결과를 제조사에 feedback하여 안전성능 개선에 이바지하고자 한다.

  • PDF

A Study on the Calculation Method of Load standard for ZEB activation (ZEB 활성화를 위한 부하기준 산정 방법 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.92-99
    • /
    • 2017
  • In Korea, the zero energy building was designated as the 7 new industries in the Ministry of Land and the 8 new industries in the Ministry of Industry. In order to maximize the insulation performance of the building envelope, improve the efficiency of building equipment, We are aiming. It is necessary to analyze the energy requirements of the buildings (cooling, heating, hot water supply, lighting, ventilation) of buildings with energy efficiency level of 1++ which is equivalent to the zero energy building certification system in Korea, It is aimed to be used as basic data for the advancement of energy building certification system. Zero Energy Building certification is estimated to be 61 buildings by 2017, and the approximate reference value and the first energy requirement for each of the five loads are calculated considering passive and active aspects. It is difficult to say that it is a clear standard because there is a small sample of data for calculating the load standard. However, it is necessary to interpret various methods in order to upgrade the Zero Energy Building certification standard in the future.

ESCO Case - Taipei 101

  • An, Yeong-Geun
    • The Magazine for Energy Service Companies
    • /
    • s.71
    • /
    • pp.72-75
    • /
    • 2011
  • 대만 타이페이의 랜드마크 Taipei 101 빌딩은 지상 101층 지하 5층의 508m 높이의 건물로 두바이의 버즈 두바이가 완공되기 전까지 명실상부 전세계에서 제일 높은 빌딩으로 위용을 뽐냈다. 게다가 Taipei 101은 LEED 그린 빌딩 순위에서 최상위 레벨인 LEED-EBOM 플라티늄을 획득하기도 하였다. 대나무 모양의 건물이 독특한 외관을 자랑하는 TAIPEI 101에 대해 좀 더 구체적으로 알아보기로 한다.

  • PDF

Safety Performance Evaluation of Technical Independence 5kW Class Fuel Cell System (기술자립형 5kW급 건물용 연료전지시스템 안전성능 평가)

  • Lee, Jungwoon;Kim, Younggyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.82.1-82.1
    • /
    • 2011
  • 최근 국내에서 발생된 대규모 정전사태로 인해 안정적인 전력공급에 대한 국민들의 요구가 커져, 지난 3월 일본 후쿠시마 원전사고 이후 다시 한번 분산전원에 대한 필요성이 대두되어지고 있다. 여러 분산전원 중 연료전지는 다른 에너지원에 비해 에너지의 지속성이 우수하여 가장 안정적인 분산전원 형태의 하나이다. 이에 따라 국내의 경우 우수한 도시가스 인프라로 인해 건물용 연료전지라는 신기술에 대한 국민의 수용성은 점점 높아질 것으로 기대된다. 현재 건물용 연료전지의 경우, 주로 1kW급 연료전지가 시범보급되어 각 가정에 설치되어지고 있으나, 상가, 주유소 및 편의점 등의 상업시설과 생활관 및 소형빌라 등의 집단 주거시설 같은 1kW급 보다 용량을 더 필요로 하는 응용처에 국내에서 개발된 5kW급 연료전지시스템이 적용되어지기를 기대한다. 본 연구에서는 국내 제작된 5kW급 고분자전해질 연료전지시스템의 보급이전에 안전성능 평가를 통해 시스템의 성능 및 안전성 평가결과를 제조사에 피드백 하여 5kW급 건물용 연료전지시스템의 조기 상업화에 앞장서고자 한다. 5kW급 연료전지시스템의 기술개발은 핵심부품인 연료변환기, 스택 및 BOP 기술의 경우 1kW급 연료전지시스템에 적용된 것과는 다른 기술이 필요하고, 단순한 scale-up 과정이 아닌 새로운 기술개발로 제품에 적용시켜야 하는 난점을 가지고 있다. 특히, 연료변환기의 경우 연료 유량의 증가로 인하여 reformer, CO shift 및 Prox 반응기의 유체역학, 열교환 흐름 및 촉매반응 공학적으로 이론을 응용한 새로운 반응기 설계와 제작기술 확립이 선행되어 전체적인 시스템 제작 설계에 반영되어져야 한다. 그러므로 본 연구에서는 연료전지시스템 안전성능 평가를 위해 용량증대에 따른 안전성평가 항목을 검토하고, 5kW급 연료전지시스템평가를 수행하여 시스템의 제품성능, 작동성능 및 계통연계성능에서의 안전성을 확인하였고, 정전 유풍과 같은 이상조건 및 실외 환경에 대한 시스템의 안전성도 확인하였다. 또한 부하운전 조건을 75% 및 50%로 변화시켰을 때 빠른 응답시간과 안정적인 부하변동운전을 확인하였다.

  • PDF

Rational Building Energy Assessment using Global Sensitivity Analysis (전역 민감도 분석을 이용한 건물 에너지 성능평가의 합리적 개선)

  • Yoo, Young-Seo;Yi, Dong-Hyuk;Kim, Sun-Sook;Park, Cheol-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.177-185
    • /
    • 2020
  • The building energy performance indicator, called Energy Performance Index (EPI), has been used for the past decades in South Korea. It has a list of design variables assigned with weighting factors (a, b). Unfortunately, the current EPI method is not performance-based but very close to a prescriptive rating. With this in mind, this study aims to propose a new performance-based EPI method. For this purpose, a global sensitivity analysis method, Sobol, is employed. The Sobol method is suitable for complex nonlinear models and can decompose all the output variance due to every input. The Sobol sensitivity index of each variable is defined as 0 to 1 (0 to 100%), and the sum of all sensitivity indices is equal to 1 (100%). In this study, an office building was modeled using EnergyPlus and then the Latin Hypercube Sampling (LHS) was conducted to generate a surrogate model to EnergyPlus. The sensitivity index was suggested to replace weight (a) in the existing EPI. In addition, the discrete weight (b) in the existing EPI was replaced by a set of continuous regression functions. Due to the introduction of the sensitivity index and the continuous regression functions, the new proposed approach can provide far more accurate outcome than the existing EPI (R2: 0.83 vs. R2: 0.01 for cooling, R2: 0.66 vs. R2: 0.01 for total energy). The new proposed approach proves to be more rational, objective and performance-based than the existing EPI method.

A Study on Anti-Islanding Evaluation of Grid-Connected Power Conditioning System for Fuel Cell System in Parallel Operation (병렬 연결된 계통연계형 연료전지 전력변환장치의 단독운전방지 평가 연구)

  • Choi, Young-Joo;Oh, Gun-Woo;Kim, Min-Woo;Lee, Seung-Kuk;Park, Ga-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.5
    • /
    • pp.124-132
    • /
    • 2018
  • The supply of renewable energy has become more vigorous due to Paris Agreement. In Korea, supply policies of renewable energy is being promoted with priority given to public buildings, so, the supply of fuel cell system that are relatively easy to install in buildings is expected to expand, so it is important that study on anti-islanding evaluation of grid-connected power conditioning system(PCS) for fuel cell. In this study, we consider that KGS AB934 PC53 in domestic certification standard of PCS for fuel cell correspond with abroad standard and analyze anti-islanding evaluation that important safety performance when connected grid. Additionally, we constructed a prototype for anti-islanding evaluation of PCS for fuel cell connected in parallel and carried out the demonstration evaluation, so, we have conducted ways that ensure safety performance in accordance with the circumstances where several fuel cell systems are installed.

The Measurement of Seasonal Evapotranspiration above Corn Canopy Based on the Bowen ratio-Energy Balance Method (보우엔비(比)-에너지수지방법(收支方法)에 의한 옥수수군락(群落) 증발산(蒸發散)의 계절별(季節別) 관측(觀測))

  • Lee, Yang-Soo;Im, Jeong-Nam;Kang, Young-Hee
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.21 no.1
    • /
    • pp.15-19
    • /
    • 1988
  • Heat energy distribution forming net radiation above corn canopy was determined by means of the Bowen ratio-energy balance method. Total-global solar radiation above crop canopy during the growing season was $1,559MJm^{-2}$ and total latent heat flux density was $960MJm^{-2}$. The data showed that 61.6% of the global solar radiation was used for a heat source of evapotranspiration (ETa) above corn canopy. Mean daily ETa ranged from 2.7 to 5.6mm. Total ETa, total drymatter, and water use efficiency were 394mm, $2,214gm^{-2}$, and $5.6gm^{-2}mm^{-1}$, respectivively.

  • PDF

A Design of Photosensor Shape Considering Change of Room Situations for the Daylight Responsive Dimming Systems (광센서 조광제어시스템의 재실변화를 고려한 광센서 형상 디자인)

  • Joo, Keun-Tak;Park, Byung-Chul;Choi, An-Seop;Kyung, Chil-Han
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.1-8
    • /
    • 2005
  • Daylight responsive dimming systems have been used to save the energy in office buildings. It is needed to consider a configuration of photosensor shape for efficient management of daylight responsive dimming systems. The configuration of optimal photosensor shape must be able to measure the exact luminous flux without changing of setting positions corresponding to the changes of room situations. On this occasion optimal photosensor shape must be designed with configuration of a proper photosensor spatial distribution and location for the daylight responsive dimming systems.

적층형 박막 실리콘 태양전지 효율의 한계 및 돌파구

  • Myeong, Seung-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.27-27
    • /
    • 2010
  • 최근에 고유가와 지구온난화로 인하여 에너지가 향후 인류의 50년을 좌우할 가장 큰 문제로 대두되고 있어서 지구의 모든 에너지의 근원인 태양광을 이용하는 태양광 발전은 무한한 청정 에너지로 각광받고 있다. 빛을 흡수하여 전기에너지로 변환하는 태양전지는 풍력, 수소연료전지, 조력, 바이오에탄올 등의 신재생에너지 기술 중에서 상품성은 가장 뛰어나지만 발전단가가 가장 높은 것이 단점이다. 태양광 발전단가를 줄여서 기존의 화석에너지를 이용한 발전단가와 견줄 수 있는 그리드 패러티(grid parity)를 달성하려면 태양전지 모듈의 고효율화와 동시에 저가화가 반드시 이루어져야 한다. 현재 태양광 모듈 시장의 90%는 효율이 12-16% 정도로 높은 단결정(single crystalline or monocrystalline) 실리콘이나 다결정(polycrystalline or multicrystalline) 실리콘 등의 벌크(bulk)형 결정질 실리콘 모듈이 차지하고 있으나 원재료인 실리콘 웨이퍼의 제조단가의 50%를 차지하고 있어서 저가화가 어렵다. 반면, 원료가스를 분해하여 대면적 기판에 증착하는 박막(thin-film) 실리콘 태양전지의 경우는 차세대 태양전지로 각광받고 있다. 박막 실리콘 모듈은 매우 적은 실리콘 원재료를 소비한다. 단결정이나 다결정 실리콘 웨이퍼의 두께가 $180-250\;{\mu}m$ 정도인 것에 비해서 박막 실리콘의 두께는 $0.3-3\;{\mu}m$ 수준이다. 더불어, 유리, 플라스틱 등의 저가 기판에 저온 대면적 증착이 가능하여 저가양산화에 유리하다. 박막 실리콘 모듈은 벌크형 실리콘 모듈(-0.5%/K) 대비 낮은 온도계수[비정질 실리콘(amorphous silicon; a-Si:H)의 경우 -0.2%/K]와 빛의 세기가 약한 산란광에서도 동작하여 평균발전시간이 증가하므로 외부환경에서 우수한 발전성능을 보이고 있다. 태양전지 모듈은 상온에서의 안정화 효율을 기준으로 가격이 책정되어($/$W_p$) 판매되기 때문에 벌크형 실리콘 모듈에 비해서 박막 실리콘 모듈은 가격대 성능비가 우수하다. 따라서 박막 실리콘 모듈은 벌크형 결정 실리콘 모듈의 대안으로 떠오르고 있으며, 레이저 기술을 이용하여 수려한 투광형 건물일체형(building integrated photovoltaic; BIPV) 모듈을 제작할 수 있는 장점도 있다. 이러한 장점에도 불구하고 기존의 양산화된 단일접합 비정질 실리콘 태양광 모듈은 효율이 6-7%로 낮아서 설치면적 및 설치 모듈의 증가가 성장의 걸림돌이 되고 있다. 박막 실리콘 태양전지의 고효율화를 도모하기 위해서 적층형 탄뎀셀로 양산 트렌드가 변화하고 있다. 이에 적층형 박막 실리콘 태양전지 효율의 한계 및 돌파구에 대해서 논의한다.

  • PDF