• Title/Summary/Keyword: 5공프로우브

Search Result 5, Processing Time 0.016 seconds

The Effect of Reynolds Number on the Calibration of a Five-Hole Probe at Low Reynolds Numbers (저 Reynolds 수 영역에서 Reynolds 수가 5공 프로우브의 보정에 미치는 영향)

  • Lee, Sang Woo;Jun, Sang Dae
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.193-199
    • /
    • 2000
  • The effects of Reynolds number on the non-nulling calibration of a cone-type five-hole probe in low-speed flows have been investigated at the Reynolds numbers of $2.04{\times}10^3,\;4.09{\times}10^3$, and $6.13{\times}10^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. The result shows that each calibration coefficient, in general, is a function of the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting for the full non-nulling calibration characteristics. Due to the interference of the probe stem, the calibration coefficients have more Reynolds number sensitivity at positive pitch angles than at negative ones.

  • PDF

All Optical Wavelength Converters Based on XGM for Wide Input Power Dynamic Range (넓은 입력 다이너믹 영역을 가지는 상호이득변조 방식의 전광 파장전환기)

  • Bang, Joon-Hak;Lee, Sang-Rok;Lee, Sung-Un;Lee, Jong-Hyun
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.8
    • /
    • pp.62-67
    • /
    • 1999
  • In this letter, a scheme for increasing the input power dynamic range of wavelength converters based on cross-gain modulation (XGM) in semiconductor optical amplifiers (SOA/s) is proposed. We investigate the effect of input pump and probe powers on the power penalty, the measure of performance for the wavelength converters. As a result, we show that the optimal bit error rate (BER) performance can be obtained when the probe power is kept 3 dB weaker than the pump power. Using this characteristic, we propose the wavelength converter scheme that controls the probe power level by monitoring the input pump power and adjusting the bias current of probe source accordingly. Consequently, the wavelength converter for wide input power dynamic range can be implemented. We show that an input power dynamic range of more than 20 dB at 2.5 Gb/s is achievable.

  • PDF

Experimental investigation of flow parameters influencing the calibration of five-hole probes (5공프로우브의 보정에 영향을 주는 유동변수들에 대한 실험적 연구)

  • Lee, Sang-U;Yun, Tae-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.637-649
    • /
    • 1997
  • Effects of cone angle, pressure-hole orientation and Reynolds number on the five-hole probe calibration have been investigated for eight large-scale conical five-hole probes, which have either perpendicular pressure holes or forward-facing pressure holes for the cone angles of 45 deg, 60 deg, 75 deg and 90.deg. Pitch and yaw angles are changed from -40 deg to +40 deg with an interval of 5 deg, respectively, when the probe Reynolds numbers are 1.77*10$^{4}$, 3.53*10$^{4}$ and 7.06*10$^{4}$. The result shows that larger cone angle results in more sensitive changes in the calibration coefficients. In the case that the cone angle is 45 deg, the pitch-angle and yaw-angle coefficients of the five-hole probe with the perpendicular pressure holes show a very different trend compared with those of the five-hole probe with the forward-facing pressure holes. On the other hand, when the cone angle is more than 60 deg, each calibration coefficient is nearly independent of the pressure-hole orientation. Additionally, the effects of the Reynolds number on the calibration coefficients are also reported in detail.

Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 실험적 연구)

  • Choi, Jin-Yong;Cho, Lee-Sang;Cho, Jin-Soo;Won, Eu-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

Experimental Study on the Aerodynamic Characteristics of a Two Stage and a Counter-Rotating Axial Flow Fan (2단 축류팬과 엇회전식 축류팬의 공력 특성에 관한 실험적 연구)

  • Cho, Lee-Sang;Cho, Jin-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.541-547
    • /
    • 2000
  • Experiments were done for the comparison of performance and flow characteristics between a two stage axial flow fan and a counter-rotating axial flow fm. The fan performance curves were obtained by the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe by the non-nulling method. Each stage of the two stage axial flow fan used for the present study has an eight bladed rotor and thirteen stator blades. The front and the rear rotor of the counter-rotating axial flow fan have eight blades each and are driven by coaxial counter rotating shafts through a gear box located between the rear rotor and the electric motor. Both of the two axial fan configurations use identical rotor blades and the same operating conditions for the one-to-one comparison of the two. Performance characteristics of the two configurations were obtained and compared by varying the blade setting angles and axial gaps between the blade rows. The passage flow fields between the hub and tip of the fans were measured and analyzed for the particular operating conditions of peak efficiency, minimum and maximum pressure coefficients.

  • PDF