• Title/Summary/Keyword: 4M method

Search Result 11,369, Processing Time 0.042 seconds

A Study on the rapid calculating of reliability for Fault Tree (FT의 빠른 신뢰도계산을 위한 연구)

  • 이일재;이광원
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.180-190
    • /
    • 1997
  • A new method in the fault tree analysis (FTA) for the reliability calculation is suggested. Two steps are necessary in traditional method in evaluation of the occurrence probability of top event in fault tree (FT). The first step is to find the minimal outsets, and the second one is to substitute the result into the poincare equation. In order to reduce the enormous computing time of this method, lots of rapid algorithms have been developed. Almost of all achievements were, however, based on the partial structural properties of FT. In this paper, the FT is transformed to a non-linear graph G which has the same minimal outsets of original n, and then the reliability is calculated using the domination theory. In this new method, the required number of equation terms are at most $2^n$ (n is node number of graph G), while $2^m$-1 (m is the number of minimal cutsets) calculation terms are required in the poincare equation in traditional method. Since m>>n in general. our new method reduces the calculation time significantly.

  • PDF

Catalytic Spectrophotometry for the Determination of Manganese at Trace Levels by a Novel Indicator Reaction (새로운 지시약 반응에 의해 극미량 수준의 망간 측정을 위한 촉매 반응의 분광 광도 측정법)

  • Gurkan, Ramazan;Caylak, Osman
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.556-566
    • /
    • 2010
  • A new kinetic spectrophotometric method is developed for the measurement of Mn(II) in natural water samples. The method is based on the catalytic effect of Mn(II) with the oxidation of Gallocyanin by $KIO_4$ using nitrilotriacetic acid (NTA) as an activation reagent at 620 nm. The optimum conditions obtained are $4.00{\times}1^{-5}\;M$ Gallocyanin, $KIO_4$, $1.00{\times}10^{-4}\;M$ NTA, 0.1 M HAc/NaAc buffer of pH = 3.50, the reaction time of 5 min and the temperature of $30^{\circ}C$. Under the optimum conditions, the proposed method allows the measurement of Mn(II) in a range of $0.1\;-\;4.0\;ng\;mL^{-1}$ and with a detection limit of down to $0.025\;ng\;mL^{-1}$. The recovery efficiency in measuring the standard Mn(II) solution is in a range of 98.5 - 102%, and the RSD is in a range of 0.76 - 1.25%. The newly developed kinetic method has been successfully applied to the measurement of Mn(II) in both some environmental water samples and certified standard reference river water sample, JAC-0031 with satisfying results. Moreover, few cations and anions interfere with the measurement of Mn(II). Compared with the other catalytic-kinetic methods and instrumental methods, the proposed kinetic method shows fairly good selectivity and sensitivity, low cost, cheapness, low detection limit and rapidity. It can easily and successfully be applied to the real water samples with relatively low salt content and complex matrices such as bottled drinking water, cold and hot spring waters, lake water, river water samples.

A simple method for detection of CMV viral RNAs and satellite RNAs in Korean pepper.

  • J.H. Sung;Park, J.H.;H.Y. Shin;M.U. Chang;H. Sayama;H. Atarashi
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.150.3-151
    • /
    • 2003
  • To analyze the genome of Cucumber mosaic virus(CMV) in pepper, we developed a new extraction method for double-stranded RNA(dsRNA). To isolate the dsRNA, 0.1g of pepper leaves homogenized with 1ml of 5${\times}$EXB extraction buffer[0.5M glycin, 0.5M NaCl, 5mM EDTA(pH9.0/NaOH), 10% Sodium N-lauryl salcosinate(NLS), 10% Sodium dodecylsulfate(SDS)] and purified with the 1/4 volume of phenol: chloroform: isoamylalcohol(25:24:1). dsRNAs from the aqueous phase was precipitated with isopropanol. This procedure was able to detect a minimal amount of dsRNA from CMV infected plant tissue and to distinguish different CMV satellite RNAs by polyacrylamide gel electrophoresis(PAGE). Moreover, this method can be applied CMV infected in pepper or Rice dwarf virus (RDV) infected rice.

  • PDF

Application of Microwave Digestion Pretreatment Techniques for ICP-AES Analysis of Used Monolithic Automobile Catalysts Having Platinum Group-Metals and Silicates (백금족 금속과 규산염을 포함하는 모노리스형 자동차 폐촉매의 ICP-AES 분석을 위한 극초단파 분해 전처리 기법의 응용)

  • Kim, Choong-Hyon;Woo, Seong Ihl;Jeon, Sung Hwan
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.568-575
    • /
    • 1999
  • Two different digestion procedures for the simultaneous determination of major and platinum-group element(PGE) in spent automobile catalysts containing PGE and silicates by inductively coupled plasma atomic emission spectrometry(ICP-AES) are compared. Combinations of mixed aids using HF, $HNO_3$, HCl, $HClO_4$, $H_2O_2$, and $H_3BO_3$ are utilized for the hot plate dissolution method and the closed-vessel microwave digestion method, The latter method has been shown to be relatively superior in terms of recovery, analysis time, and amount of aqua regia (3 parts HCl + part $HNO_3$ required to dissolve PGE in comparison with conventional open vessel hot-plate dissolution. The best results were drawn from the following conditions: In closed Teflon PFA vessels under microwave heating with temperature/pressure regulation, a 0.25 g portion of sample was digested in 2 mL of HF, 2 mL of $HNO_3$ and 6mL of HCl under the pressure of 200 psi(13.79 bar) at $180^{\circ}C$ for 1hr, followed by a second digestion stage with 16 mL of 5%(w/v) boric acid under the pressure of 20 psi(1.38 bar) at $100^{\circ}C$ for 10 min. After the microwave heating, the sample was post-treated with 10 mL of aqua regia twice by hot-plate heating. This condition gives the PGE recovery within 85~110% and the relative standard deviations within 2%. The method developed can therefore be regarded as an alternative method for routine analysis of spent automobile catalysts.

  • PDF

Fabrication and Characterization of Thermopile on Low-Stress $Si_3N_4$ Membrane for Microspectrometer Infrared Sensor (마이크로 스펙트로미터 적외선 센서용 저응력 $Si_3N_4$ Membrane 상에서의 Thermopile 제조 및 특성)

  • Choi, Gong-Hee;Park, Kwang-Bum;Park, Joon-Shik;Chung, Kwan-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.781-784
    • /
    • 2005
  • Twenty four types of thermopile for micro spectrometer infrared sensors were fabricated on low-stress $Si_3N_4$ membranes with $1.2{\mu}m-thickness$ using MEMS technology. Poly-Si thin film with thickness of 3500 ${\AA}$ as the first thermocouple material, was deposited by LPCVD method. And aluminum thin film with thickness of 6000 ${\AA}$ as the second thermocouple material, was deposited by sputtering method. Thermopile were designed and fabricated for optimum conditions by five parameters of thermocouple numbers (16 ${\sim}$ 48), thermocouple line widths (10 ${\mu}m$ ${\sim}$ 25 ${\mu}m$), thermocouple lengths (100 ${\mu}m$ ${\sim}$ 500 ${\mu}m$), membrane areas ($1^2\;mm^2$ ${\sim}$ $2.5^2\;mm^2$) and junction areas (150 ${\mu}m^2$ ${\sim}$ 750 ${\mu}m^2$), respectively. Electromotive forces of fabricated thermopile were measured 1.1 mV ${\sim}$ 7.4 mV at $400^{\circ}C$. It was thought that measurement results could be used for thermopile infrared sensors optimum structure for micro spectrometers.

  • PDF

Establishment of Manufacturing Conditions for Magnesium Alloy Thin Plate using Melt Drag Method (용융드래그방법을 이용한 마그네슘 합금 박판의 제조조건 확립)

  • Han, Chang-Suk;Kwon, Yong-Jun
    • Korean Journal of Materials Research
    • /
    • v.31 no.9
    • /
    • pp.511-518
    • /
    • 2021
  • An investigation is performed to clarify the manufacturing conditions of pure magnesium and AZ31 magnesium alloy thin plate using the melt drag method. By the melt drag method, suitable for magnesium molten metal, pure magnesium can be produced as a continuous thin plate with a thickness of 1.4 mm to 2.4 mm in the range of 5 m/min to 20 m/min of roll speed, and the width of the thin plate to the nozzle outlet width. AZ31 magnesium alloy is able to produce a continuous sheet of thickness in the range of 5 m/min to 30 m/min in roll circumferential speed, with a thickness of 0.6 mm to 1.6 mm and a width of the sheet matching the nozzle outlet width. In the magnesium melt drag method, the faster the circumferential speed of the roll, the shorter the contact time between the molten metal and the roll, and it is found that the thickness of the produced thin plate becomes thinner. The effect of the circumferential roll speed on the thickness of the thin plate is evident in the low roll circumferential region, where the circumferential speed is 30 m/min or less. The AZ31 thin plate manufactured by the melt drag method has a finer grain size as the thickness of the thin plate decreases, but it is currently judged that this is not the effect of cooling by the roll.

HisCoM-PAGE: software for hierarchical structural component models for pathway analysis of gene expression data

  • Mok, Lydia;Park, Taesung
    • Genomics & Informatics
    • /
    • v.17 no.4
    • /
    • pp.45.1-45.3
    • /
    • 2019
  • To identify pathways associated with survival phenotypes using gene expression data, we recently proposed the hierarchical structural component model for pathway analysis of gene expression data (HisCoM-PAGE) method. The HisCoM-PAGE software can consider hierarchical structural relationships between genes and pathways and analyze multiple pathways simultaneously. It can be applied to various types of gene expression data, such as microarray data or RNA sequencing data. We expect that the HisCoM-PAGE software will make our method more easily accessible to researchers who want to perform pathway analysis for survival times.

Compositional homogeneity of potassium lithium niobate crystals grown by micro pulling down method ($\mu\textrm{m}$-PD법에 의해 육성한 KLN 단결정의 조성적 균일성)

  • Dae-Ho Yoon;Tsuguo Fukuda
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.4
    • /
    • pp.405-410
    • /
    • 1994
  • KLN crystals were grown with various melt compositions by $\mu\textrm{m}$-PD method. The composition of KLN crystals was determined by DTA and X-ray diffraction measurements. It can be obtained that KLN micro crystals have a nearly homogeneous composition along the growth axis because of the absence of convection in melt growth interface.

  • PDF

Evaluation of wind power potential for selecting suitable wind turbine

  • Sukkiramathi, K.;Rajkumar, R.;Seshaiah, C.V.
    • Wind and Structures
    • /
    • v.31 no.4
    • /
    • pp.311-319
    • /
    • 2020
  • India is a developing nation and heavily spends on the development of wind power plants to meet the national energy demand. The objective of this paper is to investigate wind power potential of Ennore site using wind data collected over a period of two years by three parameter Weibull distribution. The Weibull parameters are estimated using maximum likelihood, least square method and moment method and the accuracy is determined using R2 and root mean square error values. The site specific capacity factor is calculated by the mathematical model developed by three parameter Weibull distribution at different hub heights above the ground level. At last, the wind energy economic analysis is carried out using capacity factor at 30 m, 40 m and 50 m height for different wind turbine models. The analysis showed that the site has potential to install utility wind turbines to generate energy at the lowest cost per kilowatt-hour at height of 50 m. This research provides information of wind characteristics of potential sites and helps in selecting suitable wind turbine.

Determination of Histidine by Spectrofluorometry (형광광도법에 의한 Histidine의 정량에 관한 연구)

  • Cha, Ki Won;Huang, Huazi
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.180-183
    • /
    • 2004
  • A simple and sensitive determination method of histidine has been investigated using the spectrofluorometry. An emission peak of $Eu^{3+}$ - TTA- histidine complex occurs at 470 nm in aquous solution with excitation at 235 nm and the fluorescence intensity increased linearly with addition of histidine in the range of $1{\times}10^{-7}-4{\times}10^{-6}M$. The detection limits was $5{\times}10^{-7}M$ with 3.5% RSD. The present method was applied to determine histidine content in the synthetic sample.