여자 창던지기 도움닫기 최종 1보 착지와 릴리즈 국면의 운동학적 분석 (The Kinematic Analysis of the Last Stride landing and Release Phase in the Women Javelin)

  • 홍순모;이영선;김태삼
    • 한국운동역학회지
    • /
    • 제14권1호
    • /
    • pp.51-63
    • /
    • 2004
  • The purpose of this study was to investigate a three dimensional kinematic variables about the last stride and the release phase of the throwing technique for female javelin throwers. For the motion analysis, Six female javelin throwers were used as subjects. Three-dimensional coordinates were collected using the Kwon3D Motion Analysis Package Version 2.1 Program. Two S-VHS Video Cameras were used to record the locations and orientations of control object and the performances of the subjects at a frequency of 6.0 HZ. After the kinematic variables such as the time, the distance, the velocity, and the angle were analyzed about the last stride and release phase, the followings were achieved; 1. For the effectively javelin throwing, the subjects appeared to do long the approach time in the phasel of landing phase, and short the delivery time in release phase 2. In the release event, the other subjects except for subject A appeared to throwing in the lower condition than the height of themselves. This result showed to slow the projecion velocity. 3. For increase the projection vcelocity of the upper extremity joint in the release event, it appeared to do extend rather the shoulder angle than increase the extension of elbow joint. 4. The body of COG angle showed to gradually increase nearly at the vertical axis in the release event. But the front lean angle of trunk showed a small angle compare to increase of the body of COG angle. Therefore for the effectively momentum transmission of the whole body in the javelin, the front and back lean angle of trunk appeared to do fastly transfer the angle displacement in the arch posture or the crescent condition during the deliverly motion of the release phase.

경제적인 보안 모니터링 시스템 설계 및 구현 (Design and Implementation of Economical Security Monitoring System)

  • 류석기;이순흠
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.1101-1107
    • /
    • 2010
  • VCR에 비해 성능이 우수하여 DVR이 보안 모니터링 시스템에 활발히 사용되고 있다. 본 논문에서는 기존 DVR의 성능을 향상시킬 수 있는 DVR 인터페이스와 중계 장치를 설계 구현하여 대규모 보안감시시스템을 경제적으로 구축할 수 있도록 하였다. 본 논문의 중계 장치는 8대의 감시 단말기를 DVR 두 채널에 수용하며, 한 개의 DVR 인터페이스는 16개의 중계 장치를 관리하여 총 128대의 감시 단말기를 수용할 수 있다. 결국, 본 시스템은 기존 시스템보다 4배의 시스템 확장성을 가지며, DVR 인터페이스, 중계 장치 및 감시 단말기 사이의 연결에 동축 케이블 대신 저렴한 UTP 케이블을 사용할 수 있도록 하여 설치비용을 대폭 절감할 수 있다. 또한 본 보안 모니터링 시스템은 영상전송, 음성통화, 비상호출, RFID 카드 등의 다양한 기능들이 하나로 통합되어 있어, 다양한 환경과 조건에서 효과적으로 사용될 수 있다.

과학적 모델의 사회적 구성 수업에서 구현된 두 과학 교사의 실천적 지식의 내용 (The Contents of Practical Knowledge Realized in Two Science Teachers' Classes on Social Construction of Scientific Models)

  • 김소정;맹승호;차현정;김찬종;최승언
    • 한국과학교육학회지
    • /
    • 제33권4호
    • /
    • pp.807-825
    • /
    • 2013
  • 이 연구는 과학적 모델의 사회적 구성 과정을 목적으로 설계된 수업을 실행한 두 과학 교사의 과학 수업에서 형성되었던 실천적 지식의 내용을 Elbaz가 제시한 실천적 지식의 5가지 내용 범주를 준거로 조사하였다. 이를 위해 두 과학 교사의 과학 수업에 대한 참여 관찰 및 수업 촬영 비디오 자료를 바탕으로 행위 동안의 반성 과정 및 수업 후 면담에 반영된 교사들의 내러티브를 통한 행위에 대한 반성 과정을 질적으로 분석하였다. 연구 결과, 1) 두 과학 교사의 수업 실행 과정에서 학생들이 과학적인 모델을 구성할 수 있도록 지원하는 비계를 제공할 때 교과내용 지식에 대한 실천적 지식이 발현되는 것을 볼 수 있었다. 2) 교육 과정에 대한 교사의 지식이 어려운 과학 개념의 이해와 전달에서 주어진 학습 목표에 적절한 모델 형성으로 수업의 목표를 변화하는데 중요함을 알 수 있었다. 3) 참여 교사의 교수법 지식의 실행은 과학적 모델의 사회적 구성 수업의 의도에 맞추어 학생들의 모둠 활동과 모델 생성 활동을 지원하는 방향으로 변화하였다. 4) 교사의 자아에 대한 실천적 지식은 학생들이 모둠 활동을 통해 과학적 모델을 구성하는 것을 지원할 수 있으려면, 교사는 조력자, 안내자, 그리고 격려자로서 자신의 역할을 인식하고 변화된 역할을 적절하게 수행하는 것이 중요함을 보여주었다. 5) 두 참여 교사의 학습 환경에 대한 실천적 지식은 수업을 진행하는 동안 각 모둠과 교사가 형성한 상호작용의 양상을 통해 발현되었으며, 두 교사는 함께 뛰는 운동 선수 또는 그라운드 옆의 코치와 같은 양상을 보였다. 이상의 결과를 바탕으로 과학적 모델 구성에 대한 영역 특이적 실천적 지식의 특성에 대해 논의하였다.

지상파 DMB를 이용한 클립캐스트 서비스 설계 및 구현 (Design and Implementation of Clipcast Service via Terrestrial DMB)

  • 조석현;서종수
    • 방송공학회논문지
    • /
    • 제16권1호
    • /
    • pp.23-32
    • /
    • 2011
  • 본 논문에서는 지상파 DMB를 이용하여 동영상, mp3, 텍스트, 정지영상 등 파일의 일부분인 클립을 전송하고 단말기에서 수신하는 클립캐스트 서비스를 위한 시스템 설계를 제안하고 구현하였다. 지상파 DMB 클립캐스트를 위해서는 데이터 채널의 별도 할당이 필요하며 이를 위해서는 기존 대역의 재조정이 필요하다. 클립캐스트는 지상파 DMB 시청이 적은 심야시간 (03:00~04:00)에 콘텐츠를 전송하며 비디오 서비스의 비트율을 352 Kbps로 낮추고 TPEG 서비스 대역을 이용하면 320 Kbps의 비트율로 클립캐스트 전송이 가능하다. 또한 단말기의 DMB 프로그램 구동을 위해 SMS(Short Message Service) 구동 방식과 EPG(Electronic Program Guide) 구동방식을 제안하였다. 클립캐스트 서비스는 멀티미디어 객체를 전송하는 MOT 프로토콜을 이용하며 파일의 안정적인 전송을 위하여 카루젤 형태로 2번 반복하여 전송한다. 이럴 경우 1시간 동안 전송 가능한 데이터 용량은 72 Mbyte로서, 500 Kbps급의 동영상을 시청할 경우 약 20분 정도의 동영상 서비스가 가능하다. 지상파 DMB 데이터 채널로 전송되는 클립을 표출할 때에는 CMS(Content Management Server)와 통신하여 각 클립의 길이에 대한 정보를 전달받은 후, 에러 없이 전송된 파일에 대해서만 표출해 준다. 각 콘텐츠는 사용자에게 미리보기 형식으로 제공이 가능하고 해당 콘텐츠 전체를 이용하기 위해서는 해당 콘텐츠에 할당된 URL로 접속하여 과금 과정을 거친 후 콘텐츠 다운로드가 가능하게 된다. 본 논문에서는 클립캐스트 서비스를 위한 지상파 DMB 시스템 설계를 제안하고 이를 구현함으로써 MediaFLO, DVB-H 등 타 모바일 방송에서 서비스하고 있는 파일 다운로드 서비스의 구현이 가능하게 되었다. 클립캐스트 서비스를 위한 단말기의 구동으로 타 모바일 방송에서는 EPG 구동 방식만 구현한데 비해 본 시스템에서는 EPG 보다 수신 신뢰성이 높은 SMS를 이용한 구동 방식을 제안함으로써 보다 안정된 서비스 제공이 가능하게 되었다. 이에 따라 클립캐스트 서비스에서 SMS와 EPG를 같이 이용하여 단말기를 구동시키는 하이브리드 구동 방식도 가능하게 되었다.

IEEE 802.15.6 WBAN 환경에서 QoS를 고려한 실시간 트래픽 성능향상에 관한 연구 (A Study on Real Time Traffic Performance Improvement Considering QoS in IEEE 802.15.6 WBAN Environments)

  • 노승민;김정호;강철호
    • 대한전자공학회논문지TC
    • /
    • 제48권4호
    • /
    • pp.84-91
    • /
    • 2011
  • 최근 IEEE 802.15.6 을 중심으로 표준화가 진행중인 WBAN (Wireless Body Area Network) 은 인체 내부 혹은 인체로부터 3 미터 이내의 주변에서 일어나는 근거리 무선통신을 목적으로 하는 네트워크이다. 근거리 무선네트워크에서 효과적인 QoS 조절기법과 오디오 및 비디오 데이터를 한정된 대역폭에서의 효율적인 관리는 사용자 뿐 아니라, 통신네트워크의 부하측면에서도 중요한 요소이다. 본 논문에서는 IEEE 802.15.6 고속 WBAN 표준에서, 한정된 데이터에 대해 수퍼프레임의 조정을 통해 효율적인 대역관리를 해주는 동적 할당 알고리즘과 가중치 공평 큐잉(WFQ:Weighted Fair Queueing) 알고리즘을 제안한다. 이것은 Quality of Service (QoS)를 기준으로 한 큐잉 알고리즘을 바탕으로 QoS의 질적인 요소에 대해 robust한 성능을 나타내며 공평성을 유지하고 시스템 성능을 최대화하는 효율적인 알고리즘이다. 제안한 알고리즘에 대한 성능평가 결과, 동적 할당을 적용한 경우 전송대역폭은 최대 5배가 확장되었으며, 가중치 공평큐잉을 적용한 경우 throughput은 최대 24.3%가 개선되고, delay bound 문제가 해결됨을 확인할 수 있었다.

개인화 서비스를 위한 모바일 콘텐츠 변환 시스템 연구 (Mobile Contents Transformation System Research for Personalization Service)

  • 배종환;조영희;이정재;김남진
    • 지능정보연구
    • /
    • 제17권2호
    • /
    • pp.119-128
    • /
    • 2011
  • 최근 사용자 정보와 주변 환경의 정보를 수집할 수 있는 센서의 기술과 휴대 디바이스의 성능이 매우 발달되어 왔다. 이러한 기술 발달로 인해 사용자는 매우 다양한 콘텐츠를 이용할 수 있게 되었다. 그러나 사용자가 휴대한 디바이스의 특성에 따라 이용할 수 있는 콘텐츠가 제한적이다. 이것을 해결하기 위해 하나의 콘텐츠를 여러 디바이스에서 사용하기 위한 연구가 활발히 진행 중이다. 본 연구에서는 사용자 주변의 센서를 통한 다양한 정보를 수집하여 사용자의 상황에 맞는 특정 콘텐츠를 선정하고, 선정된 콘텐츠를 사용자가 휴대한 디바이스 특성에 맞게 변환하여 서비스를 제공하는 시스템을 제안한다.

IC-임베디드 PCB 공정을 사용한 DVB-T/H SiP 설계 (Design of DVB-T/H SiP using IC-embedded PCB Process)

  • 이태헌;이장훈;윤영민;최석문;김창균;송인채;김부균;위재경
    • 대한전자공학회논문지SD
    • /
    • 제47권9호
    • /
    • pp.14-23
    • /
    • 2010
  • 본 논문에서는 유럽에서 사용되는 이동형 디지털 방송인 DVB-T/H 신호를 수신 및 신호처리 가능한 DVB-T/H SiP를 제작하였다. DVB-T/H SiP는 칩이 PCB 내부에 삽입될 수 있는 IC-임베디드 PCB 공정을 적용하여 설계되었다. DVB-T/H SiP에 삽입된 DVB-T/H IC는 신호를 수신하는 RF 칩과 어플리케이션 프로세서에서 활용할 수 있도록 수신된 신호를 변환하는 디지털 칩 2개를 원칩화한 모바일 TV용 SoC 이다. SiP 에는 DVB-T/H IC를 동작하기 위해 클럭소스로써 38.4MHz의 크리스탈을 이용하고, 전원공급을 위해 3MHz로 동작하는 DC-DC Converter와 LDO를 사용하였다. 제작된 DVB-T/H SiP는 $8mm{\times}8mm$ 의 4 Layer로 구성되었으며, IC-임베디드 PCB 기술을 사용하여 DVB-T/H IC는 2층과 3층에 배치시켰다. 시뮬레이션 결과 Ground Plane과 비아의 확보로 RF 신호선의 감도가 개선되었으며 SiP로 제작하는 경우에 Power 전달선에 존재하는 캐패시터와 인덕터의 조정이 필수적임을 확인하였다. 제작된 DVB-T/H SiP의 전력 소모는 평균 297mW이며 전력 효율은 87%로써 기존 모듈과 동등한 수준으로 구현되었고, 크기는 기존 모듈과 비교하여 70% 이상 감소하였다. 그러나 기존 모듈 대비평균 3.8dB의 수신 감도 하락이 나타났다. 이는 SiP에 존재하는 DC-DC Converter의 노이즈로 인한 2.8dB의 신호 감도 저하에 기인한 것이다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.