• Title/Summary/Keyword: 4D-CT

Search Result 575, Processing Time 0.027 seconds

Study of bony trabecular characteristics using bone morphometry and micro-CT (골형태분석법과 micro-CT를 이용한 골소주 특성에 대한 연구)

  • Song, Young-Han;Lee, Wan;Lee, Chang-Jin;Ji, Jung-Hyun;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose : The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Materials and Methods : Twenty-one female (Newzealand, about 16 weeks old, 2.9-3.4kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Baseline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1, 2, 3, 5, 6 months respectively, BMD tests were performed on the proximal femur by using PIXlmus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custome computer program and 2D/3D bone structure analysis by micro-CT (Skyscan 1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD Result : BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp, Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Conclusion : Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change.

  • PDF

The Accuracy Rate in Comprehension of Aspects of Nasal Bone Fracture Based on Simple X-ray and 2D CT Compared with 3D Image (비골 골절 형태의 입체적 분석에 있어 3D 영상과 비교한 단순방사선영상 및 2D CT 영상의 정확도)

  • Han, Dong Gil;Kim, Tae Seob;Park, David Dae Hwan;Shim, Jeong Su;Lee, Yong Jig
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.111-118
    • /
    • 2012
  • Purpose: The nasal bone fracture is known as the most common facial fracture, with the postoperative results and the patient's satisfaction known to be lower than other facial fractures. The patient's satisfaction is firstly related to the accurate comprehension of the spatial relationship in the fractured nasal bone and secondly to the accurate reduction based on accurate comprehension. The aim of this study is to evaluate the objective usefulness of the three-dimensional (3D) imaging. Methods: The survey was conducted on 10 randomly selected cases of nasal bone fractures among the 46 cases with 3D computed tomography (CT) during the past one year. It was requested upon 4 plastic residents and 4 plastic surgeons to draw 3D aspect of fractured nasal bone directly on the printed photos of cadaver nasal bone, based on simple X-ray and two-dimensional (2D) CT. They were compared with the real fractured nasal bone aspects based on the 3D image and marked the difference in the 10-point scale of 0 to 10. Results: The average score of the 4 residents was 1.62 and that of the 4 surgeons was 4.47 out of 10 by simple X-ray. The average score of the 4 residents was 5.67 and that of the 4 surgeons was 7.25 out of 10 by 2D CT. Conclusion: It was surmised that the precise analysis and accurate comprehension of the spatial relationship of the fractured nasal bone using the 3D image, as based on the 2D CT images, can produce more favorable satisfaction levels in the patients.

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

On the development of S/W tools for industrial 3D X-ray computed tomography employing general software (범용 소프트웨어를 사용한 산업용 3차원 X-ray Computed Tomography의 툴 개발)

  • Choi, Hyeong-Seok;Yang, Yoon-Gi
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.768-776
    • /
    • 2019
  • With the deployment of 4-th generation industrial revolution, the computer based manufacturing technologies employing advanced IT technology are much more popular than any other past years. In this research, some novel S/W technologies related to the industrial X-ray CT (computed tomography) for the inspection of the industrial parts are introduced. First, newly constructed industrial X-ray CT is presented in this paper, where some basic principles and functions of the CT are described. Then some research platforms are developed to generate more advanced functionalities of the industrial CT. Especially, the data transform from CT to general S/W such as Matlab is conducted. And based on this techniques, some supplementary S/W platform such as GUI (graphical user interface) of the CT S/W and some 3D voxel based image processing technologies can be developed in this paper. The industrial CT is one of the rare research items and it's values can be much more enhanced when it is used with advanced IT technologies.

Effect of condensed tannins from Ficus infectoria and Psidium guajava leaf meal mixture on nutrient metabolism, methane emission and performance of lambs

  • Pathak, A.K.;Dutta, Narayan;Pattanaik, A.K.;Chaturvedi, V.B.;Sharma, K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.12
    • /
    • pp.1702-1710
    • /
    • 2017
  • Objective: The study examined the effect of condensed tannins (CT) containing Ficus infectoria and Psidium guajava leaf meal mixture (LMM) supplementation on nutrient metabolism, methane emission and performance of lambs. Methods: Twenty four lambs of ~6 months age (average body weight $10.1{\pm}0.60kg$) were randomly divided into 4 dietary treatments (CT-0, CT-1, CT-1.5, and CT-2 containing 0, 1.0, 1.5, and 2.0 percent CT through LMM, respectively) consisting of 6 lambs each in a completely randomized design. All the lambs were offered a basal diet of wheat straw ad libitum, oat hay (100 g/d) along with required amount of concentrate mixture to meet their nutrient requirements for a period of 6 months. After 3 months of experimental feeding, a metabolism trial of 6 days duration was conducted on all 24 lambs to determine nutrient digestibility and nitrogen balance. Urinary excretion of purine derivatives and microbial protein synthesis were determined using high performance liquid chromatography. Respiration chamber study was started at the mid of 5th month of experimental feeding trial. Whole energy balance trials were conducted on individual lamb one after the other, in an open circuit respiration calorimeter. Results: Intake of dry matter and organic matter (g/d) was significantly (p<0.05) higher in CT-1.5 than control. Digestibility of various nutrients did not differ irrespective of treatments. Nitrogen retention and microbial nitrogen synthesis (g/d) was significantly (p<0.01) higher in CT-1.5 and CT-2 groups relative to CT-0.Total body weight gain (kg) and average daily gain (g) were significantly (linear, p<0.01) higher in CT-1.5 followed by CT-1 and CT-0, respectively. Feed conversion ratio (FCR) by lambs was significantly (linear, p<0.01) better in CT-1.5 followed by CT-2 and CT-0, respectively. Total wool yield (g; g/d) was linearly (p<0.05) higher for CT-1.5 than CT-0. Methane emission was linearly decreased (p<0.05) in CT groups and reduction was highest (p<0.01) in CT-2 followed by CT-1.5 and CT-1. Methane energy (kcal/d) was linearly decreased (p<0.05) in CT groups. Conclusion: The CT supplementation at 1% to 2% of the diet through Ficus infectoria and Psidium guajava LMM significantly improved nitrogen metabolism, growth performance, wool yield, FCR and reduced methane emission by lambs.

How to Determine the Moving Target Exactly Considering Target Size and Respiratory Motion: A Phantom Study (종양의 움직임과 호흡주기에 따른 체적 변화에 대한 연구: 팬텀 Study)

  • Kim, Min-Su;Back, Geum-Mun;Kim, Dae-Sup;Kang, Tae-Yeong;Hong, Dong-Ki;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.145-153
    • /
    • 2010
  • Purpose: To accurately define internal target volume (ITV) for treatment of moving target considering tumor size and respiratory motion, we quantitatively investigated volume of target volume delineated on CT images from helical CT and 4D CT scans. Materials and Methods: CT images for a 1D moving phantom with diameters of 1.5, 3, and 6 cm, acryl spheres were acquired using a LightSpeed $RT^{16}CT$ simulator. To analyze effect of tumor motion on target delineation, the CT image of the phantoms with various moving distances of 1~4 cm, and respiratory periods of 3~6 seconds, were acquired. For investigating the accuracy of the target trajectory, volume ratio of the target volumes delineated on CT images to expected volumes calculated with diameters of spherical phantom and moving distance were compared. Results: Ratio$_{helical}$ for the diameter of 1, 5, 3, and 6 cm targets were $32{\pm}14%$, $45{\pm}14%$, and $58{\pm}13%$, respectively, in the all cases. As to 4DCT, RatioMIP were $98{\pm}8%$, $97{\pm}5%$, and $95{\pm}1%$, respectively. Conclusion: The target volumes delineated on MIP images well represented the target trajectory, in comparison to those from helical CT. Target volume delineation on MIP images might be reasonable especially for treatment of early stage lung cancer, with meticulous attention to small size target, large respiratory motion, and fast breathing.

  • PDF

Elicitor-induced Phenylalanine-Ammonia Lyase, Cinnamic Acid 4-Hydroxylase and $rho-Coumaroyl$ transferase Activity in Ephedra Distachya Cultures

  • Song, Kyung-Sik;Yutaka Ebizuka
    • Archives of Pharmacal Research
    • /
    • v.19 no.3
    • /
    • pp.219-222
    • /
    • 1996
  • Ephedra olistachya cultures have been known to accumulate $rho-coumaroylamino$ acids by elicitor treatment. Based on their chemical structures, the biosynthetic pathway of$rho-coumaroylamino$acids was postulated and phenylalanine ammonia-lyase (PAL), cinnamic acid 4-hydroxylase (4-CH) and p-coumaroyl CoA: D-Ala p-coumaroyltransferase ($rho-CT$) were supposed to be involved in the pathway. The time course inductions of these enzymes were investigated after treatment of yeast extract, yeast-derived mannan glycopeptide and D-Ala. They were detectable at only 4 hours and reached to their maximum level at 9 hours after onset of elicitor treatment. The activities of PAL and 4-CH were almost disappeared within 24 hours, however, that of $rho-CT$was remained up to 48 hours irrespective of the kind of elicitors. $rho-CT$ showed substrate specificity to D-Ala at crude enzyme extract level.

  • PDF

Assessment of The Accuracy of The MR Abdominal Adipose Tissue Volumetry using 3D Gradient Dual Echo 2-Point DIXON Technique using CT as Reference

  • Kang, Sung-Jin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.603-615
    • /
    • 2016
  • In this study, in order to determine the validity and accuracy of MR imaging of 3D gradient dual echo 2-point DIXON technique for measuring abdominal adipose tissue volume and distribution, the measurements obtained by CT were set as a reference for comparison and their correlations were evaluated. CT and MRI scans were performed on each subject (17 healthy male volunteers who were fully informed about this study) to measure abdominal adipose tissue volume. Two skilled investigators individually observed the images acquired by CT and MRI in an independent environment, and directly separated the total volume using region-based thresholding segmentation method, and based on this, the total adipose tissue volume, subcutaneous adipose tissue volume and visceral adipose tissue volume were respectively measured. The correlation of the adipose tissue volume measurements with respect to the observer was examined using the Spearman test and the inter-observer agreement was evaluated using the intra-class correlation test. The correlation of the adipose tissue volume measurements by CT and MRI imaging methods was examined by simple regression analysis. In addition, using the Bland-Altman plot, the degree of agreement between the two imaging methods was evaluated. All of the statistical analysis results showed highly statistically significant correlation (p<0.05) respectively from the results of each adipose tissue volume measurements. In conclusion, MR abdominal adipose volumetry using the technique of 3D gradient dual echo 2-point DIXON showed a very high level of concordance even when compared with the adipose tissue measuring method using CT as reference.

A Study on Senior friendly function Game Industry and Culture Contents Technology(CT) R&D development process. (고령친화 기능성 게임산업과 문화콘텐츠 기술(CT) R&D 발전랑안의 모색)

  • Kim, Yeon-Jeong;Park, Hyun-Sik
    • Journal of Digital Convergence
    • /
    • v.7 no.4
    • /
    • pp.57-65
    • /
    • 2009
  • This study explored the current supply status on Contents Technology R&D(research and development) and friendly function Game Industry targeting to elderly consumers. The game contents including the functional components are categorized the sixth category of CT R&D's fundamental planning. The function game targeting to elderly focused on emotional and physical recovering to barrier, user friendliness, simplicity and certainty of game performance. The purpose of game participation are health, well-being, psychological wellness and communication. The functional game consisted of various version procedure by socio-demographic, the accessibility to game media and device.

  • PDF

위암의 진단방법으로 CT스캔의 역할

  • 조준식
    • Journal of Gastric Cancer
    • /
    • v.2 no.4
    • /
    • pp.175-179
    • /
    • 2002
  • 위암의 진단에서 CT스캔은 수술 전 병기결정이나 수술 후 추적검사에서 필수적인 검사방법으로 인정을 받고 있고, 보편적으로 가장 많이 유용되고 있다. 그러나 나선식 CT를 사용하고 여러 가지 스캔방법의 개선에도 불구하고, 인접장기로의 직접침윤, 작은 크기의 간전이의 발견, 정상 크기범위의 림프절에서 전이의 발견, 양성 림프절과 전이의 감별, 복막전이에 대한 평가에서 지금까지의 보고들은 만족스러운 결과를 얻지 못하고 있으며 CT의 한계점으로 남아 있다. 그러나 최근에는 나선식 CT보다 더 빠른 시간내 더 얇은 두께의 절편을 얻을 수 있고, 이를 이용하여 관상면 및 시상면으로 정밀하게 재구성하거나 3D영상을 얻을 수 있는 다검출식 나선식 CT가 개발되어 사용되고 있고, CT 진단의 정확도를 높일 것으로 기대한다.

  • PDF