• 제목/요약/키워드: 4D Reconstruction

검색결과 337건 처리시간 0.022초

Position Detection of a Scattering 3D Object by Use of the Axially Distributed Image Sensing Technique

  • Cho, Myungjin;Shin, Donghak;Lee, Joon-Jae
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.414-418
    • /
    • 2014
  • In this paper, we present a method to detect the position of a 3D object in scattering media by using the axially distributed sensing (ADS) method. Due to the scattering noise of the elemental images recorded by the ADS method, we apply a statistical image processing algorithm where the scattering elemental images are converted into scatter-reduced ones. With the scatter-reduced elemental images, we reconstruct the 3D images using the digital reconstruction algorithm based on ray back-projection. The reconstructed images are used for the position detection of a 3D object in the scattering medium. We perform the preliminary experiments and present experimental results.

무인 지상 로봇의 실시간 원격 제어를 위한 3차원 시각화 시스템 (3D Information based Visualization System for Real-Time Teleoperation of Unmanned Ground Vehicles)

  • 장가람;배지훈;이동혁;박재한
    • 로봇학회논문지
    • /
    • 제13권4호
    • /
    • pp.220-229
    • /
    • 2018
  • In the midst of disaster, such as an earthquake or a nuclear radiation exposure area, there are huge risks to send human crews. Many robotic researchers have studied to send UGVs in order to replace human crews at dangerous environments. So far, two-dimensional camera information has been widely used for teleoperation of UGVs. Recently, three-dimensional information based teleoperations are attempted to compensate the limitations of camera information based teleoperation. In this paper, the 3D map information of indoor and outdoor environments reconstructed in real-time is utilized in the UGV teleoperation. Further, we apply the LTE communication technology to endure the stability of the teleoperation even under the deteriorate environment. The proposed teleoperation system is performed at explosive disposal missions and their feasibilities could be verified through completion of that missions using the UGV with the Explosive Ordnance Disposal (EOD) team of Busan Port Security Corporation.

Interactive prostate shape reconstruction from 3D TRUS images

  • Furuhata, Tomotake;Song, Inho;Zhang, Hong;Rabin, Yoed;Shimada, Kenji
    • Journal of Computational Design and Engineering
    • /
    • 제1권4호
    • /
    • pp.272-288
    • /
    • 2014
  • This paper presents a two-step, semi-automated method for reconstructing a three-dimensional (3D) shape of the prostate from a 3D transrectal ultrasound (TRUS) image. While the method has been developed for prostate ultrasound imaging, it can potentially be applicable to any other organ of the body and other imaging modalities. The proposed method takes as input a 3D TRUS image and generates a watertight 3D surface model of the prostate. In the first step, the system lets the user visualize and navigate through the input volumetric image by displaying cross sectional views oriented in arbitrary directions. The user then draws partial/full contours on selected cross sectional views. In the second step, the method automatically generates a watertight 3D surface of the prostate by fitting a deformable spherical template to the set of user-specified contours. Since the method allows the user to select the best cross-sectional directions and draw only clearly recognizable partial or full contours, the user can avoid time-consuming and inaccurate guesswork on where prostate contours are located. By avoiding the usage of noisy, incomprehensible portions of the TRUS image, the proposed method yields more accurate prostate shapes than conventional methods that demand complete cross-sectional contours selected manually, or automatically using an image processing tool. Our experiments confirmed that a 3D watertight surface of the prostate can be generated within five minutes even from a volumetric image with a high level of speckles and shadow noises.

RGB-D 카메라 기반 실시간 3차원 복원기술 동향 (Recent Trends of Real-time 3D Reconstruction Technology using RGB-D Cameras)

  • 김영희;박지영;이준석
    • 전자통신동향분석
    • /
    • 제31권4호
    • /
    • pp.36-43
    • /
    • 2016
  • 실 환경에 존재하는 모든 것을 3차원 모델로 쉽게 복원할 수 있을 것이라는 생각과 원격지에 있는 환경과 사람을 같은 공간에 있는 듯 상호작용할 수 있게 된 것은 그리 오래되지 않았다. 이는 일정 해상도를 보장해주는 RGB-D 센서의 개발과 이러한 센서들을 사용한 3차원 복원 관련 연구들이 활발히 수행되면서 가능하게 되었다. 본고에서는 널리 쓰이고 있는 RGB-D 카메라를 사용하여 실시간으로 때로는 온라인상에서 3차원으로 복원하고 가시화하는 기술에 대하여 살펴보고자 한다. 하나 또는 여러 개의 RGB_D 카메라를 사용하거나 모바일 장치에 장착된 RGB-D 센서를 사용하여 넓은 공간, 움직이는 사람, 온라인 상태의 환경 등을 실시간으로 복원하기 위한 기술들을 세부적으로 설명한다. 또한, 최근에 발표된 기술들이 다루고 있는 이슈들을 설명하고 향후 3차원 복원기술의 연구개발 방향에 대해서 논의한다.

  • PDF

RP 코드 합성을 기반으로 한 세 방향 영상에서의 삼차원 모델의 복원 (3-D Model Reconstruction from Three Orthogonal Views Based on Merging Technique of RP Codes)

  • 박순용;진성일
    • 전자공학회논문지B
    • /
    • 제31B권4호
    • /
    • pp.106-114
    • /
    • 1994
  • A new merging technique is adopted for combining rectangular parallelepipes produced by 2-D rectangular code into more intuitive 30D volume elements. Rectangular parallelepiped codes (RP codes) can be used in volume-based representation of a three-dimensional object. We proposed more regularity-conserving 2-D rectangular coding scheme to merge rectangular cells represented by RP codes in three-dimensional space. After being constructed from modified 2-D rectangular code, 3-D RP codes are merged in the two orthogonal directions using new merging algorithm. The shape of merged 3-D object reconstructed by proposed algorithm is shown to be much closer to the original object shape than that of conventional RP codes. The storage requirement of merged object can be also reduced.

  • PDF

Toward High-Resolution Cryo-Electron Microscopy: Technical Review on Microcrystal-Electron Diffraction

  • Lee, Sangmin;Chung, Jeong Min;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • 제47권4호
    • /
    • pp.223-225
    • /
    • 2017
  • Cryo-electron microscopy (cryo-EM) is arguably the most powerful tool used in structural biology. It is an important analytical technique that is used for gaining insight into the functional and molecular mechanisms of biomolecules involved in several physiological processes. Cryo-EM can be separated into the following three groups according to the analytical purposes and the features of the biological samples: cryo-electron tomography (cryo-ET), cryo-single-particle reconstruction, and cryo-electron crystallography. Cryo-tomography is a unique EM technique that is used to study intact biomolecular complexes within their original environments; it can provide mechanistic insights that are challenging for other EM-methods. However, the resolution of reconstructed three-dimensional (3D) models generated by cryo-ET is relatively low, while single-particle reconstruction can reproduce biomolecular structures having near-atomic resolution without the need for crystallization unless the samples are large (>200 kDa) and highly symmetrical. Cryo-electron crystallography is subdivided into the following two categories according to the types of samples: one category that deals with two-dimensional (2D) crystalline arrays and the other category that uses 3D crystals. These two categories of electron-crystallographic techniques use different diffraction data obtained from still diffraction and continuous-rotation diffraction. In this paper, we review crystal-based cryo-EM techniques and focus on the recently developed 3D electron-crystallographic technique called microcrystal-electron diffraction.

High Resolution 3D Magnetic Resonance Fingerprinting with Hybrid Radial-Interleaved EPI Acquisition for Knee Cartilage T1, T2 Mapping

  • Han, Dongyeob;Hong, Taehwa;Lee, Yonghan;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권3호
    • /
    • pp.141-155
    • /
    • 2021
  • Purpose: To develop a 3D magnetic resonance fingerprinting (MRF) method for application in high resolution knee cartilage PD, T1, T2 mapping. Materials and Methods: A novel 3D acquisition trajectory with golden-angle rotating radial in kxy direction and interleaved echo planar imaging (EPI) acquisition in the kz direction was implemented in the MRF framework. A centric order was applied to the interleaved EPI acquisition to reduce Nyquist ghosting artifact due to field inhomogeneity. For the reconstruction, singular value decomposition (SVD) compression method was used to accelerate reconstruction time and conjugate gradient sensitivity-encoding (CG-SENSE) was performed to overcome low SNR of the high resolution data. Phantom experiments were performed to verify the proposed method. In vivo experiments were performed on 6 healthy volunteers and 2 early osteoarthritis (OA) patients. Results: In the phantom experiments, the T1 and T2 values of the proposed method were in good agreement with the spin-echo references. The results from the in vivo scans showed high quality proton density (PD), T1, T2 map with EPI echo train length (NETL = 4), acceleration factor in through plane (Rz = 5), and number of radial spokes (Nspk = 4). In patients, high T2 values (50-60 ms) were seen in all transverse, sagittal, and coronal views and the damaged cartilage regions were in agreement with the hyper-intensity regions shown on conventional turbo spin-echo (TSE) images. Conclusion: The proposed 3D MRF method can acquire high resolution (0.5 mm3) quantitative maps in practical scan time (~ 7 min and 10 sec) with full coverage of the knee (FOV: 160 × 160 × 120 mm3).

Cervical spine reconstruction after total vertebrectomy using customized three-dimensional-printed implants in dogs

  • Ji-Won Jeon;Kyu-Won Kang;Woo-Keyoung Kim;Sook Yang;Byung-Jae Kang
    • Journal of Veterinary Science
    • /
    • 제25권1호
    • /
    • pp.2.1-2.14
    • /
    • 2024
  • Background: Sufficient surgical resection is necessary for effective tumor control, but is usually limited for vertebral tumors, especially in the cervical spine in small animal neurosurgery. Objective: To evaluate the primary stability and safety of customized three-dimensional (3D)-printed implants for cervical spine reconstruction after total vertebrectomy. Methods: Customized guides and implants were designed based on computed tomography (CT) imaging of five beagle cadavers and were 3D-printed. They were used to reconstruct C5 after total vertebrectomy. Postoperative CT images were obtained to evaluate the safety and accuracy of screw positioning. After harvesting 10 vertebral specimens (C3-C7) from intact (group A) and implanted spines (group B), implant stability was analyzed using a 4-point bending test comparing with groups A and C (reconstituted with plate and pins/polymethylmethacrylate after testing in Group A). Results: All customized implants were applied without gross neurovascular damage. In addition, 90% of the screws were in a safe area, with 7.5% in grade 1 (< 1.3 mm) and 2.5% in grade 2 (> 1.3 mm). The mean entry point and angular deviations were 0.81 ± 0.43 mm and 6.50 ± 5.11°, respectively. Groups B and C significantly decreased the range of motion (ROM) in C3-C7 compared with intact spines (p = 0.033, and 0.018). Both groups reduced overall ROM and neutral zone in C4-C6, but only group B showed significance (p = 0.005, and 0.027). Conclusion: Customized 3D-printed implants could safely and accurately replace a cervical vertebra in dog cadavers while providing primary stability.

Daubechies D4 필터를 사용한 시간가변(time-varying) 볼륨 데이터의 압축 (Compression of time-varying volume data using Daubechies D4 filter)

  • 허영주;이중연;구기범
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2007년도 학술대회 1부
    • /
    • pp.982-987
    • /
    • 2007
  • The necessity of data compression scheme for volume data has been increased because of the increase of data capacity and the amount of network uses. Now we have various kinds of compression schemes, and we can choose one of them depending on the data types, application fields, the preferences, etc. However, the capacity of data which is produced by application scientists has been excessively increased, and the format of most scientific data is 3D volume. For 2D image or 3D moving pictures, many kinds of standards are established and widely used, but for 3D volume data, specially time-varying volume data, it is very difficult to find any applicable compression schemes. In this paper, we present a compression scheme for encoding time-varying volume data. This scheme is aimed to encoding time-varying volume data for visualization. This scheme uses MPEG's I- and P-frame concept for raising compression ratio. Also, it transforms volume data using Daubechies D4 filter before encoding, so that the image quality is better than other wavelet-based compression schemes. This encoding scheme encodes time-varying volume data composed of single precision floating-point data. In addition, this scheme provides the random reconstruction accessibility for an unit, and can be used for compressing large time-varying volume data using correlation between frames while preserving image qualities.

  • PDF

컴퓨터를 이용한 의료 진단용 3차원 척추 제네릭 모델 (3D Generic Vertebra Model for Computer Aided Diagnosis)

  • 이주성;백승엽;이건우
    • 한국CDE학회논문집
    • /
    • 제15권4호
    • /
    • pp.297-305
    • /
    • 2010
  • Medical image acquisition techniques such as CT and MRI have disadvantages in that the numerous time and efforts are needed. Furthermore, a great amount of radiation exposure is an inherent proberty of the CT imaging technique, a number of side-effects are expected from such method. To improve such conventional methods, a number of novel methods that can obtain 3D medical images from a few X-ray images, such as algebraic reconstruction technique (ART), have been developed. Such methods deform a generic model of the internal body part and fit them into the X-ray images to obtain the 3D model; the initial shape, therefore, affects the entire fitting process in a great deal. From this fact, we propose a novel method that can generate a 3D vertebraic generic model based on the statistical database of CT scans in this study. Moreover, we also discuss a method to generate patient-tailored generic model using the facts obtained from the statistical analysis. To do so, the mesh topologies of CT-scanned 3D vertebra models are modified to be identical to each other, and the database is constructed based on them. Furthermore, from the results of a statistical analysis on the database, the tendency of shape distribution is characterized, and the modeling parameters are extracted. By using these modeling parameters for generating the patient-tailored generic model, the computational speed and accuracy of ART can greatly be improved. Furthermore, although this study only includes an application to the C1 (Atlas) vertebra, the entire framework of our method can be applied to other body parts generally. Therefore, it is expected that the proposed method can benefit the various medical imaging applications.