• Title/Summary/Keyword: 400 MHz

Search Result 293, Processing Time 0.024 seconds

The radio frequency excited slab waveguide CO2 laser (고주파 여기식 슬랩형 도파관 CO2 레이저)

  • 김규식;이영우;우삼용;최종운
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.406-412
    • /
    • 2003
  • We have developed a radio frequency excited slab waveguide $CO_2$ laser. The dimension of active volume is 2${\times}$40${\times}$400 mm. One concave and one convex mirror are used to make the unstable resonator of the positive branch. The radio frequency is 123 MHz and RF input power is varied from 100 to 900 W. The laser gas is set to a pressure of 10∼60 torr and the mixing ratio is $CO_2$:$N_2$:He=1:1:3. The laser output power of 70.7 W was obtained which corresponds to laser power to RF power conversion efficiency of 9.2%.

A study on the alexandrite-like cubic zirconia single crystal by skull melting method (스컬법에 의한 alexandrite-like cubic zirconia 단결정성장에 관한 연구)

  • 석정원;최종건
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.5
    • /
    • pp.205-210
    • /
    • 2003
  • Alexandrite-like cubic zirconia single crystals were grown by skull melting method. The R.F. generator (output power is 35 ㎾) used for skull melting was operated at 2 MHz. The grown crystals were doped with up to 1 or 1.5 wt% and 0.5 or 1 wt% of rare earth metal ion (Pr, Nd) on$ ZrO_2-Y_2O_3$ (12 mol%). The grown crystals were cut for slice (0.25 mm) and round brilliant (12 mm in diameter). The cut stones were heat treated in air and nitrogen at $1000^{\circ}C$ for 2 hours and their optical absorption spectra ($\lambda$ = 400∼700 nm) data were obtained.

Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance (공명현상을 이용한 유방조직 팬텀의 석회화 관찰)

  • Ha, Myeung-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.61-69
    • /
    • 2008
  • Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  • PDF

A Study on a Radio System for Lifesaving in Case of a Falling Accident of the Sea (해상추락 인명구조용 무선시스템에 관한 연구)

  • Choi, Byung-Ha;Kim, Gu-Chol
    • Journal of Advanced Navigation Technology
    • /
    • v.6 no.1
    • /
    • pp.62-68
    • /
    • 2002
  • Mother ship must be able to know accident occurrence information rapidly to rescue crew who fall in sea. In this paper, designed and manufactured transceiver of prescribed 447 MHz is operating as low power radio station specified in Radio Regulation. So, it is available without special permission proceedings getting form probation so that the use of this system may be easy. the system has been started for operation when the sensor get in touch with water. The system transmits with modulation by 500Hz square wave, and the receiver alarms when the transmitted signal is received. Therefore, the system can be used for not only saving a life, but also for low speed of data transmission below 2,400 bps, and other purposes.

  • PDF

Miniaturized Radio Frequency Choke Using Modified Stubs for High Isolation in MIMO Systems

  • Lim, Seonho;Choi, Woo Cheol;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.219-223
    • /
    • 2015
  • In this paper, a miniaturized radio frequency choke (RFC) using modified stubs is proposed to improve isolation characteristics in a multiple-input-multiple-output (MIMO) antenna system. The proposed RFC, based on the LC resonance, is designed to suppress the leakage current that leads to the degradation of antenna diversity performances in the MIMO antenna configuration. The proposed RFC is composed of two open stubs that are implemented on the top of the ground plane and miniaturized by adding a slit structure on the ground plane. The MIMO antennas are also designed to verify isolation performance in the LTE 2300 band (2,300-2,400 MHz). The MIMO antennas perform well with low reflection coefficient characteristics and high isolation characteristics in the whole LTE 2300 band. To evaluate the isolation in the MIMO system, the envelope correlation coefficient (ECC) is calculated, and the value is less than 0.08. The achieved ECC is regarded as a reasonable result for improving isolation performance in the frequency range of 2,300-2,400 MHz; also, radiation patterns of antenna elements are maintained regardless of the presence of RFC.

Design and Experiment of a Miniaturized Waveguide Band-Pass Filter Using L-Type Inverter and Small Resonant Aperture (L형 아이리스와 투과 공진 개구를 이용한 소형화된 도파관 여파기 설계 및 실험)

  • Choi, Jin-Young;Kim, Byung-Mun;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.457-467
    • /
    • 2012
  • In this paper, a miniaturized band-pass filter structure, which comprises the irises of small resonant aperture and L-type irises inverter, is proposed. Ridged circular aperture iris is chosen as an elementary resonator. L-type iris which is placed between two adjacent elementary resonators is newly proposed as impedance inverter in order to reduce longitudinal length of the proposed filter. The fabricated minimized filter has 400 MHz bandwidth at the 10 GHz center frequency and the whole size is reduced to 70 % in length compared to conventional filter.

Output Characteristic of Zinc Vapour Laser With Capacitively Coupled Radio Frequency Excitation (용량결합고주파여기 아연증기레이저의 출력특성)

  • Choi, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • From a CCRF-excited zinc vapour laser with overlapped DC-discharge were emitted following 6 laser lines: two blue at 491.162[nm] and 492.403[nm], an orange at 589.433[nm] and three infrared lines at 747.879[nm], 758.848[nm] and 773.25[nm]. The discharge parameters were determined for an optimal laser operation. At a RF-power of 400[W] with the frequency 13.56[MHz] the optimal temperature of the oven lay between 780[K] and 800[K], the He-pressure between 3.5[kPa] and 5.5[kPa].

CCP and ICP Combination Impedance Matching Device for Uniformity Improvement of Semiconductor Plasma Etching System (반도체 플라즈마 식각 시스템의 균일도 향상을 위한 CCP와 ICP 결합 임피던스정합 장치)

  • Jung, Doo-Yong;Nam, Chang-Woo;Lee, Jong-Ho;Choi, Dae-Kyu;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.274-281
    • /
    • 2010
  • This paper proposes a DFPS (Dual Frequency Power Source) impedance matching device for uniformity improvement of a semiconductor plasma etching system. The DFPS consists of two parts for safe plasma processing on large-area substrates. The first part is an ICP (Inductively Coupled Plasma) for high integration by using ferrite core. The second part is a CCP (Capacitive Coupled Plasma) to control uniformity of whole cells. Proposed DFPS can achieve high productivity improvement required for semiconductor equipment industry. The proposed plasma system is analyzed, simulated and experimentally verified with a matching equipment at 27.12MHz and 400kHz.

Construction of 19F-13C Solid-State NMR Probe for 400MHz Wide-Bore Magnet

  • Jeong, Ji-Ho;Park, Yu-Geun;Choi, Sung-Sub;Kim, Yongae
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.2
    • /
    • pp.81-85
    • /
    • 2013
  • Various fluorine-containing materials are used in electronic devices like LCD display panels and Li-ion batteries. The structural conformation of fluorine in fluorinated materials is an important contributing factor that influences the chemical and physical properties. The conformation can be changed by heat and stress during manufacture or use. Understanding the conformational changes is critical for understanding the performance and durability of electronic devices. Solid-state NMR spectroscopy could be widely used for the analysis of various fluorine-containing materials for electronic devices. However, conventional CPMAS probes cannot be used for in-situ analysis of fluorine-containing electronic devices like LCD panels and Li-ion batteries. In this paper, we show the design, construction, and optimization of a $^{19}F-^{13}C$ double-resonance solid-state NMR probe for a 400MHz wide-bore magnet with a flat square coil for in-situ analysis of fluorine-containing electronic devices without observing fluorine background signals. This custom-built probe does not show any fluorine background signals, and can have higher efficiency for lossy samples.

Design of Scan Conversion Processor for 3-Dimensional Mobile Graphics Application (3차원 모바일 그래픽 응용을 위한 스캔 변환 프로세서의 설계)

  • Choi, Byeong-Yoon;Ha, Chang-Soo;Salcic, Zoran
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.11
    • /
    • pp.2107-2115
    • /
    • 2007
  • In this paper, the scan conversion processor which converts the triangle represented by three vertices into pixel-level screen coordinates, depth coordinate, and color data is designed. The processor adopts scan-line algorithm which decomposes triangle into horizontal spans and then transforms the span into pixel data. By supporting top-left filling convention, it ensures that triangles that share an edge do not produce any dropouts or overlaps between adjacent polygons. It consists of about 21,400 gates and its maximum operating frequency is about 80 Mhz under 0.35um CMOS technology. Because its maximum pixel rate is about 80 Mpixels/sec, it can be applicable to mobile graphics application.