• Title/Summary/Keyword: 4.3 Incident

Search Result 387, Processing Time 0.022 seconds

Study on a cavity ring-down spectrometer with continuous wave laser sources (연속발진 레이저를 이용한 공동 광자감쇠 분광기 연구)

  • 유용심;한재원;김재완;이재용;이해웅
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.240-244
    • /
    • 1998
  • Cavity ring-down spectroscopy (CRDS) is a high-sensitive laser spectroscopic technique capable of measuring concentrations of trace gases. We have demonstrated a new design of the CRDS spectrometer with a continuous wave (CW) laser. The ring-dwon signal is produced through blocking the incident CW laser by scanning the cavity length fast toward off-resonance iwth PZT (piezoelectric transducer). We have also measured an absorption spectrum of acetylene overtone transitions near 570 nm at the pressure of 2700 Pa, and the minimum detectable absorption coefficient has been found to be about $3{\times}10^{-9}\cm^{-1}$.

  • PDF

Synthesis of Organic Dyes with Linkers Between 9,9-Dimethylfluorenyl Terminal and α-Cyanoacrylic Acid Anchor, Effect of the Linkers on UV-Vis Absorption Spectra, and Photovoltaic Properties in Dye-Sensitized Solar Cells

  • Lee, Min-Woo;Cha, Su-Bong;Yang, Su-Jin;Park, Se-Woong;Kim, Kyung-Kon;Park, Nam-Gyu;Lee, Duck-Hyung
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2269-2279
    • /
    • 2009
  • Six metal-free organic dyes having thiophene (1), benzene-thiophene (2), thiophene-benzene (3), thiophene-pyridine (4), thiophene-thiophene (5), and pyridine (6) linkers between 9,9-dimethylfluorenyl terminal group and $\alpha$-cyanoacrylic acid anchor were synthesized. Among them, organic dye 5 showed the longest ${\lambda}_{max}$ value (424 nm) in UV-Vis absorption spectrum, better incident monochromatic photon-to-current conversion efficiency (IPCE), highest short circuit photocurrent density ($J_{SC},\;9.33\;mA^2/cm^2$), and highest overall conversion efficiency ($\eta$, 3.91%).

Proton Acceleration in Weak Quasi-parallel Intracluster Shocks: Injection and Early Acceleration

  • Kang, Hyesung;Ryu, Dongsu;Ha, Ji-Hoon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.42.1-42.1
    • /
    • 2018
  • Collisionless shocks with low sonic Mach numbers, M<4, are expected to accelerate cosmic ray (CR) protons via diffusive shock acceleration (DSA) in the intracluster medium (ICM). However, observational evidence for CR protons in the ICM has yet to be established. Performing particle-in-cell simulations, we study the injection of protons into DSA and the early development of a nonthermal particle population in weak shocks in high ${\beta}$ plasmas. Reflection of incident protons, self-excitation of plasma waves via CR-driven instabilities, and multiple cycles of shock drift acceleration are essential to the early acceleration of CR protons in supercritical quasi-parallel shocks. We find that only in ICM shocks with $M{\geq}2.3$, a sufficient fraction of incoming protons are reflected by the overshoot in the shock electric potential and magnetic mirror at locally perpendicular magnetic fields, leading to efficient excitation of magnetic waves via CR streaming instabilities and the injection into the DSA process. Since a significant fraction of ICM shocks have M < 2.3 CR proton acceleration in the ICM might be less efficient than previously expected. This may explain why the diffuse gamma-ray emission from galaxy clusters due to proton-proton collisions has not been detected so far.

  • PDF

Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent (방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작)

  • Kim, Jeongho;Park, Hyemin;Joo, Koansik
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

Injury Analysis of a 12-passenger Van Rollover Accident (12인승 밴 전복사고의 상해 분석)

  • Kim, S.C.;Choi, H.Y.;Kim, B.W.;Park, G.J.;An, S.M.;Lee, K.H.
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.1
    • /
    • pp.20-26
    • /
    • 2018
  • The fatality of rollover accidents in motor vehicle crashes is high despite their low incidence. Through the investigation of a 12-passenger van rollover accident in which 10 passengers were involved, we intend to analyze the correlation between the severity of the injury and the position of the occupants. We collected accident information from medical records, interviews, photo-images of the damaged van, field surveys, and the results of the Korean New Car Assessment Program (KNCAP). Based on the occupants' position, we classified injury sites and estimated injury severity. Passenger injury severity was evaluated by trauma score calculation. The initiation type of the rollover accident was passenger side 'fall-over' and the Collision Deformation Classification (CDC) code for the damaged van was 00TDZO3. The crash of the van involved 10 passengers, with an average age of $16.3{\pm}4.2years$. Few of the occupants had fastened seat belts at the time of the incident, and there was no airbag installed. One patient sustained severe liver injury and another was diagnosed with a fracture of the right humerus. The most common injuries were at the upper extremities and the neck. The average of Injury Severity Score (ISS) was $4.8{\pm}5.9$, and the average ISS of right-seated, mid-seated and left-seated occupants was $7.5{\pm}9.3$, $1.5{\pm}0.7$, and $3.3{\pm}2.1$ respectively (p>0.05). In the rollover (to-passenger side) accident of occupant unfastened, the average ISS of right-seated occupants (near side) was higher, but there was no statistically significant difference.

AN ANALYSIS OF INFRARED IMAGES OF JUPITER IMPACTED BY P/SHOEMAKER-LEVY 9

  • KIM YONG HA;SUNG KIYUN;KIM SANG JOON;COCHRAN W. D.;LESTER D. F.;TRAFTON L.;CLARK B. E.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.245-253
    • /
    • 1996
  • We have analyzed infrared (IR) images of Jupiter which was observed at the McDonald Observatory, Texas, U.S.A., during the P/SHoemaker-LEvy 9 (SL9) impact period and about one week after the last impact. The IR images were obtained on the 2.7m telescope using a NICMOS array with filters to isolate the $1.5{\mu}m\;NH_3\; band,\;the\;2.3{\mu}m\;CH_4\;band,\;the\;2.12{\mu}m\;H_2\;S(0)$ pressure-induced absorption, and the continua at $1.58{\mu}m\;and\;2.0{\mu}m$ (short K-band). All images except those with the $1.58{\mu}m$ continuum filter show bright impact sites against the relatively dark Jovian disk near the impact latitude of about $45^{\circ}$ S. This implies that dusts originated from the impacts reflect the solar radiation at high altitudes before absorbed by stratospheric $CH_4,\;NH_3 \;or\;H_2$. The impact sites observed with the $2.3{\mu}m$ filter are conspicuously bright against a very dark background. The morphology of impact sites, G, L, and H at 2.3 and $2.12{\mu}m$ filters shows clearly an asymmetric structure toward the incident direction of the comet fragments, in agreement with the studies of visible impact images obtained with the Hubble Space Telescope. Comparisons of reflectances of G, L, and H sites with simple radiative transfer models suggest that optically thick dust layers were formed at high altitudes at which methane absorption attenuates incoming sunlight only by about $1\%$. The dust layers in these sites seem to form at about the same altitude regardless of the magnitude of the impacts, but they appear to descend gradually after the impacts. The dust layers have optical depths of 2-5, according to the models.

  • PDF

Falls in the General Hospital Inpatients: Incidence, Associated Factors (일개 종합병원 입원환자의 낙상 실태 및 관련 요인)

  • Yang, Hwa-Mi;Chun, Byung-Chul
    • Quality Improvement in Health Care
    • /
    • v.15 no.2
    • /
    • pp.107-120
    • /
    • 2009
  • Background : To estimate fall incidence rate and associated factors in inpatients from a general hospital. Method : The data were collected from 104 fall incident reports developed by the patient safety committee in a general hospital in Seoul from 01 January 2007 to 31 December 2008. Information included general characteristics of patients, factors related to fall, types, places, circumstances and outcomes of fall. Result : The incidence rate of fall, which was 4.4 per 1,000 total discharged patients and 0.5 per 1,000 patient-days, was much lower than that of several hospitals in the United States. The difference may reflect the different incidence reporting system of each hospital. Fall-prone patients were, in general, $$\geq_-$$65 years of age, had an alert mental status, were ambulatory with some assistance, and were dependent on and ambulatory device. High incidence of falls was associated with patients with circulatory disease. The majority of fall events usually occurred in bed or at the bedside in the patient's room, and occurred more often during the night than during the day or evening. Risk factors of fall were use of drugs (antihypertensive or neuropsychiatric drugs) and environmental factors (e.g., overly high bed height, surrounding objects, inadequate fitness shoes and slippery floor). Physical injury occurred in 43.3% of fall events, which typically required diagnosis of injury and treatment such as suturing. Risk factors for repeated falls were use of a neuropsychiatric drug (odds ratio=13.9) and gait disturbance (odds ratio=91.2). Risk factors for fall-related injury were alert mental status (odds ratio=3.3 times more likely to fall than those who were drowsy or in a stupor) and general weakness(odds ratio=3.3 times more likely to fall than those who were not generally weak). Conclusion : Medical and nursing staff should be aware of the fall risk factors of hospitalized patients and should intensively pursue preventative strategies. Development of fall prevention education based on these results is recommended.

  • PDF

Optical(Interferometric) Measurements of Vapor Deposition Growth Rate and Dew Points in Combustion Gases (빛의 간섭현상을 이용한 증기용착 성장속도 측정법의 실험적 연구)

  • 김상수;송영훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.343-348
    • /
    • 1986
  • An optical interference method was developed for measuring rapidly growing and evaporating liquid condensate films (e.g., Na$_{2}$SO$_{4}$, $K_{2}$SO$_{4}$) on solid surface exposed to flowing combustion product gases at film thicknesses well below the onset of complications due to run-off. To develop this optical system, this study investigated the optical parameters (e.g., polarization state, incident angle, target roughness, etc.) Trends for the Na$_{2}$SO$_{4}$(l) and $K_{2}$SO$_{4}$(l) deposition rates as a function of target temperature using this optical measuring system agree with the theoretical prediction of the vapor deposition. This study was able to extend the experimental range for vapor plus condensed phase transport and deposition. While previously unable to measure the evaporation rates interferometrically, these rates are estimated from the results of the investigation of polarization states.

Near-Isotropic Tag Antenna in UHF band Using Inductively Coupled Feeding (유도 결합 구조를 응용한 UHF 대역 Near-Isotropic 태그 안테나)

  • Ahn, Jun-Oh;Jang, Hyung-Min;Moon, Hyo-Sang;Lee, Bom-Son
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.12 s.115
    • /
    • pp.1240-1248
    • /
    • 2006
  • This paper presents an UHF band(911 MHz) RFID tag antenna which has near-isotropic radiation pattern and easy conjugate impedance matching characteristics to any commercial chips of usual practice through the application of an inductively-coupled feeding. The proposed antenna of compact size $40{\times}46mm\;(0.12{\times}0.14{\lambda})$ has, at normal incidence, the maximum RCS of $-18.5dBm^2$ and the 3 dB RCS bandwidth of 9 MHz(1 %) in case of short chip load. It has the maximum and minimum RCS' of $-16.9dBm^2\;and\;-21.4dBm^2$ depending on the incident angles. The difference of about 4.5 dB is relatively small compared with that (about 70 dB) of a pure dipole antenna. The designed antenna has been fabricated and its RCS' have been measured varying the angles of incidence. The measured RCS' have been found to have good agreement with the simulated ones.

Case Analysis of the Harmful Chemical Substances' Spill (유해화학물질 유출의 사례 분석)

  • You, Jisun;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.90-98
    • /
    • 2014
  • Lately accidents of harmful chemical substance in korea were repeatedly replaying. We studied problems and preparation plan in 2008 years~2014 years through analysis cases of harmful chemical substance. Leakage of chemical substance's accident situation shows that leakage in the workplace is the most 10 cases, accounting for 58.6% is the largest proportion in 2009. Leakage according to explosion accounting for 50% (5 cases) in 2004, 25% (4 cases) in 2007 and 33.3% (4 cases) in 2011 has very irregular change. Therefore, A major cause of accidents is lack of safety management. Harmful chemical substance showed various aspects, high residual substance and non-visible characteristic so response and recovery was easy. And the second damage to move a distance causes environment pollution. So a mutual-assistance system and integrated system of related organization have to build and expert of chemical incident response and therapist of chemical substance response have to establish to do efficient and rapid response.