• 제목/요약/키워드: 4-point Bending Tester

검색결과 12건 처리시간 0.026초

플립칩의 반복 굽힘 시험 시 파손 특성에 관한 실험적 연구 (An Experimental Study on the Failure Characteristics of Flip Chips in Cyclic Bending Test)

  • 이용성;정종설;김홍석;신기훈
    • 한국생산제조학회지
    • /
    • 제18권4호
    • /
    • pp.362-368
    • /
    • 2009
  • In general, circuit board assemblies experience various mechanical loadings during assembly and in actual use. The repeated cyclic bending can cause electrical failures due to circuit board cracks, solder interconnects cracks, and the component cracks. In this paper, we report on the failure characteristics of semiconductor chips under the repeated cyclic bending. We first describe a new 4-point bending tester, which is developed according to JEDEC standard No. 22B113. The performance of the tester is then estimated through actual experiments. Test results reveal that the cracks first occur on the outer balls around 20,000 cycles and gradually propagate to the inner balls where cracks are found around 70,000 cycles.

  • PDF

극초단파의 출력과 적용시간이 의치상용 레진의 물리적 성질에 미치는 영향 (THE INFLUENCE OF WATTAGE AND CURING TIME OF MICROWAVE ENERGY ON PHYSICAL PROPERTIES OF THE DENTURE BASE RESIN)

  • 정대성;임장섭;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제37권6호
    • /
    • pp.767-775
    • /
    • 1999
  • The purpose of this study was to evaluate the effect of wattage and curing time on surface hard-ness, three-point bending strength and internal porosity of microwave curing denture base resin. Two sizes of resin specimens were made of Acron $MC^{(R)}\;;\;3.5{\times}10{\times}60mm$ for surface hardness and three-point bending strength measurement and $5{\times}12{\times}60mm$ for internal porosity measurement. They were cured by microwave energy at varing wattages(500W, 700W) and curing times(2min., 3min., 4min.) to determine if a certain wattage/curing time combination would improve physical properties. Surface hardness was measured with Vikers hardness tester, three-point bend-ing strength with universal testing machine and internal porosity was calculated by measuring the weight in air and in water. The results obtained were as follows: 1. There was no significant difference in percent porosity among experimental groups(p>0.05). 2. 500W/3min. group showed the higher surface hardness than 700W/2, 3, 4min. groups(p<0.05), and 700W/4 min. group showed the lower surface hardness than 500W/2, 3, 4min. groups(p<0.05), but there was no significant difference among others(p>0.05). 3. 500W/3min. group yielded the higher value of bending strength than 500W/2min., 700W/3, 4min. groups(p<0.05), but there was no significant difference among others(p>0.05).

  • PDF

치과용(齒科用) 아말감의 파괴인성(破壞靭性)에 관한 연구(硏究) (A STUDY ON THE FRACTURE TOUGHNESS OF DENTAL AMALGAMS)

  • 허현도;김영해
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.20-32
    • /
    • 1990
  • The plane strain fracture toughness of a material characterize the resistance to fracture in the presence of a sharp crack under severe tensile condition. Fracture toughness can be determined by indentation method. The purpose of this study was to investigate the fracture toughness of dental amalgams by measuring the plane strain fracture toughness and the fracture toughness from indentation method. Two conventional and four high copper amalgam alloys were employed for this study. The amalgams were prepared according to the A.D.A. spec. No. 1 and inserted into the specially designed mould with the single edge notch specimen to use in 3-point bending method. The specimens (20mm long, 4mm wide, 2mm thick) were stored at $37^{\circ}C$ for 1 week, and tested in 3-point bending by means of Instron at a cross-head speed of 1mm/min. In indentation method, the specimens were made in same manner as single edge notch specimens. The test was conducted with Vickers hardness tester at 10kg load. The following results were obtained. 1. The plane strain fracture toughness and the fracture toughness from indentation method were higher in the low copper amalgams than the high copper amalgams. 2. In high copper amalgams, the fracture toughness of amalgams decreases according as the copper contents increase. 3. In similar copper contents, the single composition amalgams have a higher fracture toughness than the admixed amalgams.

  • PDF

취성/연성 파괴에 대한 수명예측 모델 및 신뢰성 설계 (Development of Reliability Design Technique and Life Prediction Model for Electronic Components)

  • 김일호;이순복
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1740-1743
    • /
    • 2007
  • In this study, two types of fatigue tests were conducted. First, cyclic bending tests were performed using the micro-bending tester. A four-point bending test method was adopted, because it induces uniform stress fields within a loading span. Second, thermal fatigue tests were conducted using a pseudo power cycling machine which was newly developed for a realistic testing condition. The pseudo-power cycling method makes up for the weak points in a power cycling and a chamber cycling method. Two compositions of solder are tested in all test condition, one is lead-free solder (95.5Sn4.0Ag0.5Cu) and the other is eutectic lead-contained solder (63Sn37Pb). In the cyclic bending test, the solder that exhibits a good reliability can be reversed depending on the load conditions. The lead-contained solders have a longer fatigue life in the region where the applied load is high. On the contrary, the lead-free solder sustained more cyclic loads in the small load region. A similar trend was detected at the thermal cycling test. A three-dimensional finite element analysis model was constructed. A finite element analysis using ABAQUS was performed to extract the applied stress and strain in the solder joints. A constitutive model which includes both creep and plasticity was employed. Thermal fatigue was occurred due to the creep. And plastic deformation is main damage for bending failure. From the inelastic energy dissipation per cycle versus fatigue life curve, it can be found that the bending fatigue life is longer than the thermal fatigue life.

  • PDF

일반구조용 압연강재의 부식피로균열전파거동에 미치는 시험편 두께의 영향 (Effect of Specimen Thickness to Corrosion Fatigue Crack Propagation Behavior of Structure Rolled Steel)

  • 조약래
    • 수산해양기술연구
    • /
    • 제28권3호
    • /
    • pp.286-294
    • /
    • 1992
  • In this paper, the corrosion fatigue crack propagation behavior of structure rolled steel (SWS 41C) was investigated by changing the thickness, and this experiment was done by the three point bending corrosion fatigue tester. The main results obtained are as follows: 1) As the thickness of specimen becomes thicker, the corrosion sensitivity to initial stage crack becomes some sensitive, and that the fatigue life becomes more sensitive. 2) The crack growth rate to initial stage crack (da/dN) was retarded as the thickness of specimen becomes thicker. But after initial stage crack, as the thickness of specimen is more thicker, da/dN is more rapid. 3) As the corrosion fatigue crack length grows, the accelerative factor of thick specimen (t=12mm) is more higher than that of thin specimen (t=6mm). 4) As the corrosion fatigue crack length grows, the corroson potential of both thick specimen and thin specimen becomes more less noble potential, however thick specimen (t=12mm) tends to more less noble potential than that of thin specimen(t=6mm).

  • PDF

아연나노입자함유 교정용 레진의 물리적 특성 평가 (Evaluation of Physical Properties of Resin Containing Zinc Nanoparticle.)

  • 조정기
    • 디지털융복합연구
    • /
    • 제17권10호
    • /
    • pp.373-379
    • /
    • 2019
  • 가철성 교정장치의 자가중합 레진인 Polymethyl methacrylate(PMMA)는 색의 안정성과 체적 안정성, 조직 친화성 등의 장점이 있어 오랫동안 치과 교정장치 재료로 사용해 왔다. 하지만 이러한 가철성 교정장치는 구강내에서 사용이 길어질수록 PMMA의 낮은 강도로 인하여 사용중 교정장치 레진상이 파절되는 단점이 있다. 본 연구에서는 zinc nanoparticle (ZNP)가 orthodontic PMMA에 혼합하여 강도효과를 도입하고자한다. ZNP을 함유된 orthodontic PMMA (0, 0.5, 1.0, 2.0 및 4.0%)의 직사각형 시료($1.4{\times}3.0{\times}19.0mm$)를 제작하였다. 제작완료된 시편을 1 mm/min의 속도로 3점 굽힘강도 시험하였고, 비커스 경도는 경도기를 이용하여 3회측정하였고, 표면조도기로 표면조도를 측정하였다. 그 결과 3점 굽힘강도는 유의한 변화가 없었다(p>0.05). 경도를 평가한 결과 역시 유지됨을 관찰하였다. 표면조도도 큰 차이가 보이지 않았다. 표면에너지는 유의차 있게 증가하였다. ZNP함유된 orthodontic PMMA는 의치 및 교정용 장치의 기계적 특성 대한 유의한 차이가 없음을 확인하였다. 결과적으로 본 연구에서 ZNP를 성공적으로 합성하고 이것이 분산된 교정용 레진 시편을 제작하였다. 추후 항균실험을 추가하여 고강도와 항균력이 있는 교정장치를 개발할 수 있는 연구가 필요하다.

고주파 열처리된 SAE1055 강의 피로거동 및 이의 확률론적 평가 (Probabilistic Analysis of Fatigue Behavior of Induction Hardened Steel)

  • 이선호;이승표;강기원
    • 대한기계학회논문집A
    • /
    • 제37권3호
    • /
    • pp.429-436
    • /
    • 2013
  • 본 논문에서는 고주파 열처리된 SAE1055 베어링강의 경도에 따른 피로 거동 및 이의 확률론적 평가를 수행하였다. 이를 위하여 경도 수준에 따른 5 종류의 시험편(A : 원재료, B : HV390-전경화, C : HV510-전경화, D : HV700-전경화 및 E : HV-700 표면경화)를 준비하였다. 피로시험은 4 점 회전굽힘 피로시험기를 이용하여 응력비 R=-1 의 조건하에서 수행하였다. 그 결과, SAE1055 강의 피로 거동은 경도에 따라 크게 변화하였으나 HV510 수준이상에서는 피로한도의 증가는 관찰되지 않았다. 또한 피로 파손기구에 대한 경도의 영향을 평가하기 위하여 SEM(scanning electron microscope)을 이용한 파면 관찰을 수행하였다. 피로수명의 통계적 특성은 P-S-N(probabilistic S-N) 곡선을 이용하여 평가되었으며 이에 대한 경도의 영향은 잔류치 해석(residue analysis)을 통하여 수행하였다.

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • 이수원;정태곤;양재웅;정재영;박광민;정용훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF

플라즈마 표면처리에 의한 폴리카보네이트의 표면에너지 및 구리박막과의 접착력 변화에 관한 연구 (The Effects of Plasma Treatments on the Surface Energy of the Polycarbonates and on the Adhesion Strength of the Cu Film/Polycarbonate Interface)

  • 조병훈;이원종;박영호
    • 한국재료학회지
    • /
    • 제15권11호
    • /
    • pp.745-750
    • /
    • 2005
  • Polycarbonates are widely used as housing materials of electronic handsets. Since the polycarbonate is electrically insulating, there should be a conducting layer on the polycarbonate for EMI shielding. In this study, we sputter deposited Cu films on the polycarbonate substrates for EMI shielding. Plasma treatments of polycarbonates were used to increase the adhesion strength of the Cu film/polycarbonate interface. The surface energy of the polycarbonate was greatly increased from $30mJ/m^2 \;to\; 65mJ/m^2$ by a 200 W $O_2$ plasma treatment for 10s. It is thought that this is because of the ion bombardment. The adhesion strength of the sputter deposited Cu film to the polycarbonate was quantitatively measured by a 4 point bending tester. A moderate plasma surface treatment of the polycarbonate increased the Cu film/polycarbonate adhesion strength by $30\%$. The EMI shielding efficiency of the sputter deposited $10{\mu}m$ Cu lam on the polycarbonate showed 90dB in the range of 100MHz to 1000MHz.