• 제목/요약/키워드: 4-electrodes

검색결과 1,595건 처리시간 0.025초

Si-sealant를 이용하여 제조한 금속수소화물 전극의 특성 (The Properties of the Metal Hydride electrodes prepared by Silicon Sealant)

  • 최전;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제4권2호
    • /
    • pp.23-28
    • /
    • 1993
  • The $(LM)Ni_{4.5}Co_{0.1}Mn_{0.2}Al_{0.2}$ hydrogen storage alloy powders were conducted 25wt% electroless copper plating in an acidic bath. For the preparation of a hydride electrodes, the copper coated alloy powder was mixed with Si-sealant(organosilicon) and compacted with $6t/cm^2$ at room temperature. The electrode characteristics were examined through electrochemical measurements in a half cell. As a sealant contents increased, the initial discharge capacity of si-sealant bounded electrode was lower and the activation rate in high current density was slower. For extended cycles, however, the electrodes with the Si-sealant were superior in a high rate discharge and useful range of temperature over the sealant-free electrode. In addition, the cycle life increased with increasing the amount of Si-sealant added. It can be suggested from the results that the Si-sealant as a binder could be applied to the preparation of the metal hydride electrode.

  • PDF

Enhanced Charge Transfer Through Polypyrrole Electropolymerized on Poly(acrylonitrile-co-butadiene)/Pt Electrodes

  • Chae, Won-Seok;Moon, Jung-Nim;Kim, Kang-Jin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.603-610
    • /
    • 1995
  • The charge transfer rate in polypyrrole(PPy) electropolymerized within poly(acrylonitrile-co-butadiene)(PAB) was compared with that in PPy deposited Pt electrodes by using cyclic voltammetry, chronoamperometry, and chronopotentiometry in acetonitrile. For both electrodes anodic and cathodic peak currents were proportional to scan rates below 100 mV/sec, but to square root of scan rates beyond 200 mV/sec. The apparent diffusion coefficient of $ClO{_4}^-$ in the PPy/PAB composite is estimated to be 1.6 times larger than that in PPy. The PPy films composited within PAB layer showed higher anodic and cathodic currents and possessed faster charging-discharging process and larger capacity.

  • PDF

제세동 시행도구에 따른 제세동 지연시간의 변화 (The Changes of Defibrillation Time Depending on the Manual External Defibrillator Device)

  • 박시은;신동민
    • 한국응급구조학회지
    • /
    • 제16권1호
    • /
    • pp.81-90
    • /
    • 2012
  • Objectives: This study is to research delay time comparison for later defibrillation after hands off according to the changes in defibrillation electrodes. Study purpose: In defibrillation treatment that is the only way for cardiac arrest by arrhythmia, it is to find defibrillator device which can minimize late defibrillation delay time after important affect of hands off. Study object and method: After hands off according to the defibrillator device, we collected total 40 people for emergency medicine doctor, internal medicine doctor, general surgeon, nurse, emergency medical technician who are working at 2 CN, CS University hospitals in Gwangju Jeollanamdo district to find out hand off shock interval(HOSI). We then researched their general properties like occupation sector, experiences in clinic, gender, completion of AHA ACLS-P training and more. Then 40 participants continued ventricular fibrillation cardiac arrest simulation training (using human-model mannequin) designed by researcher and performed their roles as defibrillation operator. Each of participant used manual paddle and performed 4 times of defibrillation (150J) during 8 minutes of CPR and in 8day, the defibrillator devices were replaced from manual paddle to self-adhesive electrodes pads and 4 times of defibrillation (150J) under same simulation condition as manual paddle were performed. Study result: In comparison for delay time of later defibrillation after hands off of manual paddle and self adhesive electrodes pad, the self adhesive electrodes pad ($7.0{\pm}0.5sec$) seemed to reduce delay time of later defibrillation significantly (p<0.05) compared to manual paddle ($10.0{\pm}0.9sec$). The self adhesive electrodes pad, according to the general properties of participants, had no particular change in delay time after later defibrillation for the statistics (p>0.05) but the manual paddle had statistically significant differences for the occupation sector, experiences in clinic and gender (p<0.05). Conclusion: In defibrillation, the self adhesive electrodes pad($7.0{\pm}0.5sec$) showed short HOSI compared to manual paddle ($10.0{\pm}0.9sec$) significantly (p<0.05) and it applied identically for both existence and non-existence of ACLS-P training completion, experiences in clinic, gender and occupation sector. The manual paddle had also significant difference in experiences in clinic and occupation sector (p<0.05). which means the effect on HOSI according to the job mastery. Therefore, if the clinic experience is short or in case for the occupations without frequent defibrillation treatment has a danger of lowering success rate for the defibrillation using manual paddle. Therefore, it is true that using self adhesive electrodes pad for defibrillation electrodes when performing manual defibrillation in pre-hospital as well as in-hospital steps can generally minimize delay time of later defibrillation after hands off.

Numerical Modeling of Floating Electrodes in a Plasma Processing System

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제24권4호
    • /
    • pp.102-110
    • /
    • 2015
  • Fluid model based numerical analysis is done to simulate a plasma processing system with electrodes at floating potential. $V_f$ is a function of electron temperature, electron mass and ion mass. Commercial plasma fluid simulation softwares do not provide options for floating electrode boundary value condition. We developed a user subroutine in CFD-ACE+ and compared four different cases: grounded, dielectric, zero normal electric field and floating electric potential for a 2D-CCP (capacitively coupled plasma) with a ring electrode.

마이크로캡슐화한 축전지용 수소저장합금 전극의 충·방전 특성 (Charge and Discharge Characteristics of Microencapsulated Hydrogen Storage Alloy Electrodes for Secondary Batteries)

  • 최성수;최병진;예병준;김대룡
    • 한국수소및신에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.45-54
    • /
    • 1992
  • An applicability microencapsulation, using electroless copper plating, of hydrogen storage alloy powder as an anode material for nickel-hydrogen secondary batteries was investigated. Alloys employed were $LaNi_{4.7}Al_{0.3}$ and $MmNi_{4.5}Al_{0.5}$(Mm=mischmetal) which have an appropriate equilibrium pressure and capacity. The microencapsulation of the alloy powder was found to accelerate initial activation of electrodes and to increase capacity which is about 285mAh/g for $LaNi_{4.7}Al_{0.3}$. In addition, other charge and discharge characteristics, such as polarization and flatness of charge and discharge potential, were improved due to the role of copper layer as a microcurrent collector and an oxidation barrier of the alloy powder. $MmNi_{4.5}Al_{0.5}$ alloy showed lower capacity than $LaNi_{4.7}Al_{0.3}$ because of higher equilibrium pressure. Cyclic characteristics of both alloys were somewhat poor because of mainly shedding and partial oxidation of alloy powder during the cycling. However, it was considered that the microencapsulation method is effective to improve the performances of the hydrogen storage alloy electrodes.

  • PDF

Syntheses and Potentiometric Properties of Polyethers Containing Thiazole and Oxazole Derivatives

  • 최준혁;고영국;권일전;김홍석;박현주;김상진;차근식;남학현
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권5호
    • /
    • pp.581-586
    • /
    • 1999
  • A series of polyethers containing the thiazole or oxazole subcyclic moiety have been synthesized. Reaction of 2-aryl-4-hydroxymethylthiazole with tetra- and pentaethylene glycol di-p-tosylate in THF provided corresponding α,ω-bis[2'-aryl-4'-methylthiazole]polyethylene glycol in good yields. Similar treatment of 2-phenyl-4-hydroxymethyloxazole 7 and 2-phenyl-5-hydroxymethyloxazole 8 with tetraethylene glycol di-p-tosylate yielded the corresponding 1,13-bis [2'-phenyl-4'-methyloxazole]tetraethylene glycol 16 and 1,13-bis[2'-phenyl-5'-methyloxazole]tetraethylene glycol 17 in 69 and 43% yields in respectively. The potentiometric properties of PVC-based ion selective membranes containing 66 wt% o-nitrophenyloctyl ether (NPOE) and 4 wt% polyethers 9-17 have been examined. The membranes containing thiazole and oxazole polyether derivatives exhibited high selectivity toward silver (I) ion. It was observed that the response slopes of the electrodes to silver ion vary with the length of polyether chain linking two thiazole subcyclic moiety. Potentiometric data suggest that the number of ether units, CH2OCH2, for phenylthiazole derivatives be greater than 5 to result in near-Nernstian response. However, the response behaviors of the membrane electrodes based on phenyloxazole podands 16 and 17, which have different orientation, were correspondingly similar to those of the electrodes based on phenylthiazole podands 9 and 10. On the other hand, the ISEs based on thiazole polyether derivatives with different terminal substituents, e.g., phenyl 10, naphtyl 14, and thienyl 15, except that with pyridyl 12, exhibited little difference in their potentiometric properties.

전사 인쇄에 의한 3D와 다층의 Pt 전극의 CO가스 흡착 (CO Adsorption on Three-Dimensional and Multilayered Platinum Electrode Prepared through Transfer Printing)

  • 정윤서;최유정;신정희;정영훈;박종후;윤대호;조정호
    • 센서학회지
    • /
    • 제29권4호
    • /
    • pp.232-236
    • /
    • 2020
  • Three-dimensional (3D) multilayered Pt electrodes were fabricated to develop a porous electrode using a pattern-transfer printing process. The Pt thin films were deposited using a transferred sputtering pattern having a 250 nm line width on the substrate, and the uniform line patterns were efficiently transferred using our proposed method. Temperature-programmed desorption (TPD) analyses were used to evaluate the porosity of the electrodes. It was possible to distinguish between two resolved maxima at 168 and 227 ℃, which could be described in terms of desorption reactions on the Pt (111) planes. The results of the TPD analysis of the 3D and multilayered Pt electrodes prepared through transfer printing were compared to those of an electrode fabricated through screen printing using a commercial Pt-carbon paste commonly used as porous electrodes. It was confirmed that the 3D multilayered electrodes exhibited a desorption concentration approximately 100 times higher than that of the Pt-carbon composite electrode, and the desorption concentration increased by approximately 0.02 mg/mol per layer. The 3D multilayered electrode effectively functions as a porous electrode and a catalyst.

부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구 (Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition)

  • 차기철;손정민;김기진;최승훈
    • 대한지역사회영양학회지
    • /
    • 제2권2호
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF

근활성도(EMG) 측정 전극 레이어 설계에 따른 성능 및 안정성 평가 (Performance and Stability Evaluation of Muscle Activation (EMG) Measurement Electrodes According to Layer Design)

  • 구본학;이동희;김주용
    • 감성과학
    • /
    • 제26권4호
    • /
    • pp.41-50
    • /
    • 2023
  • 본 연구는 EMG(electromyography) 텍스타일 전극 개발을 목적으로 레이어 수의 디자인 및 원단을 다르게 하여 성능 및 신호 획득 안정성을 평가한다. 레이징 및 프레스 공정을 통하여 텍스타일 전극을 제조하며 Layer-0, Layer-1, Layer-2로 레이어 유무 및 수에 따른 결과를 분석했다. 이에 레이어 유무에 따라서는 근활성 측정에 영향을, 수가 많을수록 높은 성능이 나타남을 확인할 수 있었다. Layer-2 구조로 통일하여 5가지의 원단(네오프렌, 스판덱스 쿠션, 폴리에스테르 100%, 나일론 스판덱스, 광목 캔버스)으로 전극을 제조해 실험해 보았다. 성능적인 면에서, 원단의 중량이 높은 나일론 스판덱스가 높은 성능을 보였으며, 스판쿠션 텍스타일 전극이 근활성도 수득에 높은 안정성을 보였다. 이에 위 연구는 레이어에 따른 성능 연관성과 전극-피부사이의 닿는 면적 간의 관계 등을 고찰하여 슬리브 전체의 의복압을 늘리는 대신 특정 센서 측정 부위에만 높은 압력을 가함으로 차후 연구에서 레이어의 수 및 물성에 따른 전극의 공학적 설계 가능성을 제시한 의의가 있다.

The Effects of LaF3 Coating on the Electrochemical Property of Li[Ni0.3Co0.4Mn0.3]O2 Cathode Material

  • Yun, Su-Hyun;Kim, Seuk-Buom;Park, Yong-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권11호
    • /
    • pp.2584-2588
    • /
    • 2009
  • The effect of $LaF_3$ coating on the structural and electrochemical properties of $Li[Ni_{0.3}Co_{0.4}Mn_{0.3}]O_{2}$ cathodes was investigated using XRD, SEM, TEM, and a cycler. The coating layer consisted of nano-sized particles attached nonuniformly to the surface of pristine powder. Despite the surface coating treatment, phase difference by $LaF_3$ coating was not detected. The discharge capacities of coated electrodes were a little lower than that of pristine sample at a 1 C rate. However, as the C rate increases, the capacity retention of the coated sample becomes obviously superior to that of the pristine sample. The cyclic performances of the electrodes in the voltage range of 4.8 $\sim$ 3.0 V were also improved by the surface coating. Such enhancement is attributed to the presence of the $LaF_3$ coating layer, which effectively suppressd the reaction between electrodes and electrolytes on the surface of the $Li[Ni_{0.3}Co_{0.4}Mn_{0.3}]O_{2}$ electrode.