• 제목/요약/키워드: 4-ball test

검색결과 294건 처리시간 0.027초

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF

차량 운행에 따른 엔진오일의 성능특성 평가 연구 (The study on performance of characteristics in engine oil by vehicle driving)

  • 이정민;임영관;정충섭;;한관욱;나병기
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.237-244
    • /
    • 2013
  • 엔진오일은 다양한 내연기관의 윤활을 위한 가장 기본적인 윤활제이다. 최근 자동차사 및 엔진오일 제조사 등은 엔진오일의 교환주기를 15000~20000 km를 권장하고 있는 반면, 대부분의 정비관련업자 및 운전자들은 엔진오일의 성능진보와는 별개로 관습적으로 매5000 km 마다 엔진오일을 교환권유 또는 인식하고 있다. 빈번한 엔진오일의 교환은 폐엔진오일로 인한 환경오염과 차량 유지비 등의 증가요인으로 대두되고 있다. 따라서 본 연구에서는 신유와 실제 운행조건의 차량을 활용하여 5000 km, 10000 km를 각각 주행한 후 회수된 사용엔진오일의 다양한 물성으로 인화점, 유동점, 동점도, 저온겉보기점도, 전산가, 4구식 내마모시험 및 금속분을 조사 분석하였다. 결과적으로 사용엔진오일은 신유에 비해 전산가, 마모흔, 철과 구리 성분 증가가 다소 관찰되었지만, 주행거리별 사용엔진오일의 물성 및 금속분 변화는 거의 유사하였다.

플립 칩 BGA 솔더 접합부의 열사이클링 해석 (Thermal Cycling Analysis of Flip-Chip BGA Solder Joints)

  • 유정희;김경섭
    • 마이크로전자및패키징학회지
    • /
    • 제10권1호
    • /
    • pp.45-50
    • /
    • 2003
  • 시스템 보드에 플립 칩 BGA가 실장된 3차원 유한요소 해석 모델을 구성하여 열사이클시험 과정에서 발생되는 솔더 접합부의 피로수명을 예측하였다. 피로 모델은 Darveaux의 경험식에 기초하여 비선형 점소성 해석을 수행하였다. 해석은 4종류의 열사이클시험 조건과 패드구조, 솔더 볼의 조성과 크기의 변화에 따라 발생하는 크리프 수명을 평가하였다. 해석결과 $-65∼150^{\circ}C$의 열사이클시험 조건에서 가장 짧은 피로수명을 보였으며, $0∼100^{\circ}C$ 조건과 비교하면 약 3.5 배 정도 증가하였다. 동일한 시험조건에서 패드구조 변화에 따른 피로수명 차이는 SMD구조가 NSMD구조에 비해 약 5.7% 증가하였다 결과적으로 솔더 접합부에서 크리프 변형에너지 밀도가 높으면 피로수명은 짧아지는 것을 알 수 있었다

  • PDF

NDT Determination of Cement Mortar Compressive Strength Using SASW Technique

  • Cho, Young-Sang
    • KCI Concrete Journal
    • /
    • 제13권2호
    • /
    • pp.10-18
    • /
    • 2001
  • The spectral analysis of surface waves (SASW) method, which is an in-situ seismic technique, has mainly been developed and used for many years to determine the stiffness profile of layered media (such as asphalt concrete and layered soils) in an infinite half-space. This paper presents a modified experimental technique for nondestructive evaluation of in-place cement mortar compressive strength in single-layer concrete slabs of rather a finite thickness through a correlation to surface wave velocity. This correlation can be used in the quality control of early age cement mortar structures and in evaluating the integrity of structural members where the infinite half space condition is not met. In the proposed SASW field test, the surface of the structural members is subjected to an impact, using a 12 mm steel ball, to generate surface wave energy at various frequencies. Two accelerometer receivers detect the energy transmitted through the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$).

  • PDF

LM 가이드의 내마모성 향상을 위한 Me-DLC 코팅박막의 성능평가 (The Performance Test on Me-DLC Films for Improving Wear Resistance of LM-Guide)

  • 강은구;이동윤;김성영
    • 한국정밀공학회지
    • /
    • 제29권4호
    • /
    • pp.409-416
    • /
    • 2012
  • Recently, surface modification technology is of importance to improve the wear resistance and the corrosive resistance for high accurate mechanical parts such as LM guide, Ball Screw and Roller Bearing etc., Those has generally featured on rolling contact mechanism to improve not only the wear and the friction, but also the accuracy and the corrosion performances. For surface modifications of high accurate mechanical parts, normally thermal spray, PVD, CVD and E.P. processes have been used with many materials such as DLC, raydent, W, Ni, Ti etc. Diamondlike carbon (DLC) films possess a combination of attractive properties and have been largely employed to modify the tribological behaviors such as friction, wear, corrosion, fretting fatigue, biocompatibility, etc. However, for rolling contact mechanism mechanical parts DLC films are needed to study for commercial benefit. Rolling contact mechanism has features on effects of cyclic motions and stresses, and also not simply sliding motions. The papers focused on the performance test of wear and corrosive resistance according to Me-DLC film thickness. And also, its thickness effect of wear analysis was carried out through the simulation of the maximum shear stress under the rolling contact surface. As the results, Me-DLC films have more potential to improve the wear resistance for high precision mechanical parts than raydent films.

Effect of Lubricant with Nanodiamond Particles in Sliding Friction

  • Adzaman, M.H.;Rahman, A.;Lee, Y.Z.;Kim, S.S.
    • Tribology and Lubricants
    • /
    • 제31권4호
    • /
    • pp.183-188
    • /
    • 2015
  • This paper presents the experimental effects of lubricant with nanodiamond particles in sliding friction. In order to improve the performance of lubricants many additives are used, such as MoS2, cadmium chloride, indium, sulfides, and phosphides. These additives are harmful to human health and to the environment, so alternatives are necessary. One such alternative is nanodiamond powder, which has a large surface area. In order to investigate the effect of nanodiamonds in lubricants under sliding friction, they are dispersed in the lubricant at a variety of concentrations (0 wt%, 0.1 wt%, 0.3 wt%, 0.5 wt%, and 1 wt%) using the matrix synthesis method. Friction and wear tests are performed according to the ASTM G99 method using a pin-on-disc tester at room temperature. The specimens used in this experiment are AISI 52100 ball bearings and AISI 1020 steel discs. During the test, lubricant mixed with nanodiamond is supplied constantly to keep the two bodies separated by a lubricant film. To maintain boundary lubrication, the speed is set to 0.18 m/s and a load of 294 N is applied to the disc through the pin. Results are recorded by using workbench software over the test duration of 10 minutes. Experimental results show that when the concentration of nanodiamond increases, the coefficient of friction decreases. However, above a nanodiamond concentration of 0.5 wt%, both the coefficient of friction and wear volume increase. From this experiment, the optimum concentration of nanodiamond showing a minimum coefficient of friction of 0.09 and minimum wear volume of 0.82 nm2 was 0.5 wt%.

치료적 운동이 축구 특이적 골반 앞 기울임을 가진 유소년 축구선수 엉덩관절의 관절가동범위, 도수근력, 기능적 움직임 및 방사선학적 평가에 미치는 영향: 증례보고 (Effects of Therapeutic Exercise on Hip Joint Range of Motion, Manual Muscle Test, Functional Movement Screen and Radiological Evaluation in a Youth Football Player with Football-specific Anterior Pelvic Tilt: A Case Report)

  • 유동훈;서상원;이호성
    • 대한물리의학회지
    • /
    • 제13권4호
    • /
    • pp.85-94
    • /
    • 2018
  • PURPOSE: This study was conducted to determine the effects of therapeutic exercise on range of motion (ROM), the manual muscle test (MMT), functional movement screen (FMS) and radiological evaluation in a youth football player with football-specific anterior pelvic tilt (APT). METHODS: The subject of this case report was a 12-year-old youth football player, who presented with football-specific APT. Therapeutic exercise consisted of hamstring stretch, prone hip extension, abdominal crunch, bridging with isometric hip abduction, plank exercise with posterior tilt and posterior pelvic tilting exercise using a swiss-ball for 40 min/day, twice a week for 8-weeks. ROM, MMT, FMS (deep squat, hurdle step, inline lunge, shoulder mobility, active straight-leg raise, rotary stability and trunk stability push-up) and radiographs (lumbar lordotic and sacral horizontal angle) were analyzed before and after week 8 of therapeutic exercise. RESULTS: The ROM, MMT, and FMS increased and the lumbar lordotic angle and sacral horizontal angle improved after 8-weeks of therapeutic exercise. CONCLUSION: The results of this case report suggest that therapeutic exercise improves ROM, MMT and radiography associated parameters in youth football players with football-specific APT. These findings have clinical implications for therapeutic exercise in youth football players with football-specific APT.

상악 총의치 정중 파절 수리 시 금속선 및 유리섬유의 보강효과 비교 (Comparison of metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture)

  • 이정이;조재영;윤미정;전영찬;정창모;허중보
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.284-291
    • /
    • 2013
  • 연구 목적: 상악 레진상 총의치의 정중 파절부에 금속선과 유리섬유 보강재를 사용하여 수리하였을 때 파절 강도 및 파절 양상을 비교해 보고자 하였다. 연구 재료 및 방법: 본 연구에서는 상악 의치의 정중부 파절을 재현한 뒤, 자가중합레진과 보강재를 사용하여 수리하였다. 보강재의 종류에 따라 3개의 군(대조군, 보강재 없음; W 군, 금속선; G 군, 섬유유리)으로 나누었으며, 각군당10개의 시편을 제작하였다. Instron test machine (Instron Co., Canton, MA, USA)으로 5.0 mm/min의 크로스헤드 속도를 부여하여 파절 강도를 구하였으며, 이때 하중은 20 mm의 지름을 가진 구형 하중체를 통해 의치 중심부에 전달되었다. 파절 강도 시험 후 나타난 의치의 파절 양상을 분석하였다. Kruskal-wallis test와 Mann-whitney U test를 이용하여 ${\alpha}=.05$ 수준에서 검정하였다. 결과: 파절 강도는W 군에서 가장 높은 값을 보였고, 대조군과 G 군 사이에서는 통계적으로 유의한 차이를 보이지 않았다(P>.05). 대조군과W군에서는 전후방파절 양상을 주로 보였고, G군에서는 보강재를 따라 파절되는 양상을 주로 보였다. 결론: 본 연구의 한계 내에서, 상악 총의치의 수리 시 유리섬유 보강재를 이용하는 경우 파절 강도가 향상되지 않았으며(P>.05), 유리섬유 보강재를 따라 접착 실패를 보이는 파절 양상이 나타났다.

노인들의 규칙적인 체육활동이 노후불안 수준에 미치는 영향 (The Effect of Regular Exercise on anxiety Level of Older People)

  • 전익기;이선희
    • 한국노년학
    • /
    • 제28권4호
    • /
    • pp.953-968
    • /
    • 2008
  • 본 연구는 노인들을 대상으로 노후불안 수준이 어떠한지 알아보며, 규칙적인 체육활동을 실시하기 전과 후의 노후불안 수준을 파악할 것이며, 구체적으로 노후불안 수준이 체육활동을 통해 얼마큼 감소되는지 밝혀내는데 본 연구의 목적이 있다. 본 연구의 대상은 서울, 경기 지역에 위치한 L노인대학, S노인대학, J노인대학, Y(a)노인대학, Y(b) 노인대학, D노인대학에 체육활동 강좌(건강체조, 게이트볼, 스포츠댄스) 수강생을 모집단으로 선정하였으며, 비확률표집방법(nonprobability)의 편의표본추출법(convenience sampling)을 이용하여 총 200명을 연구대상자로 선정하였다. 조사대상자의 연령을 고려하여, 직접 기입방법과 일대일 면접법을 병행하여 총 200부의 자료를 수집하였다. 자료처리는 SPSS 12.0 Version통계 패키지를 이용하였으며, 모든 통계치의 유의 수준은 .05로 정하였다. 분석방법은 빈도분석(Frequency Analysis), 대응표본 t-test (Paired t-test), 독립표본 t-test(Independent t-test)를 실시하였다. 노인들이 규칙적인 체육활동을 실시하기 전과 후의 노후불안 인식수준의 차이를 분석한 결과, 노후불안은 4가지 요인으로 구분된다. 첫째, 체육활동 실시 전 상실에 대한 두려움은 (M=3.756), 실시 후에는 (M=1.942)으로 나타났다. 둘째, 노인에 대한 두려움은 체육활동 실시 전 (M=3.443), 실시 후 (M=2.243)으로 나타났다. 셋째, 신체적 외모에 대한 걱정에서는 체육활동 실시 전 (M=3.253), 실시 후 (M=2.310)으로 나타났다. 마지막 요인인 심리적 불안정 요인에서는 체육활동 실시 전 (M=3.060), 실시 후 (M=1.666)으로 나타났으며, 모든 요인이 유의수준 .001에서 통계적으로 유의한 차이가 나타났으며, 전체적인 요인 모두 사전테스트 전 보다 노후불안점수가 낮게 나타나 체육활동이 노인의 불안수준을 낮추는 것으로 나타났다.

지지면 조건에 따른 코어근육 강화효과의 비교 (The comparisons of effect of core muscle strengthening by the surface conditions)

  • 김정희;김준호;박병우;김소망;이선욱;김민경;김나율;윤소정;황혜민;김윤정;주선영
    • 대한물리치료과학회지
    • /
    • 제24권1호
    • /
    • pp.1-13
    • /
    • 2017
  • Purpose: The objective of this study was compare the effect of core muscle strengthening between core exercise on stable surface and core exercise on unstable surface. Methods: Thirty-nine adults participated in this study and were randomly allocated to three groups. The stable surface exercise group and unstable surface exercise groups practiced core muscle training for $3{\times}30minute$ sessions over a 4-week period. The control group did not received therapeutic intervention except pre and post test. The following clinical tools were used to assess core muscle strength and balance: Side Plank Test, Trunk Flexion Test, Balance Error Scoring Test, Core Muscle Stength & Stability Test. Results: The stable surface exercise group showed significant improvement in trunk muscle strength of anterolateral part as revealed by the Side Plank Test and Trunk flexion Test(p<.05). The unstable surface exercise group showed significant improvement in trunk muscle strength of anterolateral part and balance ability as revealed by the Balance Error Scoring Test and Core Muscle Strength & Stability Test(p<.05). Conclusion: The results of this study, both core exercise on stable surface and core exercise on unstable surface induced core muscle strengthening and balance ability. Expecially core exercise on unstable surface more effective to core muscle strengthening and balance ability.

  • PDF