Kim, Jin-Su;Lee, Dong-Soo;Lee, Byung-Il;Lee, Jae-Sung;Shin, Hee-Won;Chung, June-Key;Lee, Myung-Chul
The Korean Journal of Nuclear Medicine
/
v.36
no.6
/
pp.317-324
/
2002
Purpose: The use of statistical parametric mapping (SPM) program has increased for the analysis of brain PET and SPECT images. Montreal Neurological Institute (MNI) coordinate is used in SPM program as a standard anatomical framework. While the most researchers look up Talairach atlas to report the localization of the activations detected in SPM program, there is significant disparity between MNI templates and Talairach atlas. That disparity between Talairach and MNI coordinates makes the interpretation of SPM result time consuming, subjective and inaccurate. The purpose of this study was to develop a program to provide objective anatomical information of each x-y-z position in ICBM coordinate. Materials and Methods: Program was designed to provide the anatomical information for the given x-y-z position in MNI coordinate based on the Statistical Probabilistic Anatomical Map (SPAM) images of ICBM. When x-y-z position was given to the program, names of the anatomical structures with non-zero probability and the probabilities that the given position belongs to the structures were tabulated. The program was coded using IDL and JAVA language for 4he easy transplantation to any operating system or platform. Utility of this program was shown by comparing the results of this program to those of SPM program. Preliminary validation study was peformed by applying this program to the analysis of PET brain activation study of human memory in which the anatomical information on the activated areas are previously known. Results: Real time retrieval of probabilistic information with 1 mm spatial resolution was archived using the programs. Validation study showed the relevance of this program: probability that the activated area for memory belonged to hippocampal formation was more than 80%. Conclusion: These programs will be useful for the result interpretation of the image analysis peformed on MNI coordinate, as done in SPM program.
So, Young;Lee, Kang-Wook;Lee, Sun-Woo;Ghi, Ick-Sung;Song, Chang-June
The Korean Journal of Nuclear Medicine
/
v.36
no.4
/
pp.232-243
/
2002
Purpose: We studied whether brain perfusion SPECT is useful in the psychiatric disability evaluation of patients with chronic traumatic brain injury (TBI). Materials and Methods: Sixty-nine patients (M:F=58:11, age $39{\pm}14$ years) who underwent Tc-99m HMPAO brain SPECT, brain MRI and neuropsychological (NP) tests during hospitalization in psychiatric wards for the psychiatric disability evaluation were included; the severity of injury was mild in 31, moderate in 17 and severe in 21. SPECT, MRI, NP tests were peformed $6{\sim}61$ months (mean 23 months) post-injury. Diagnostic accuracy of SPECT and MRI to show hypoperfusion or abnormal signal intensity in patients with cognitive impairment represented by NP test results were compared. Results: Forty-two patients were considered to have cognitive impairment on NP tests and 27 not. Brain SPECT showed 71% sensitivity and 85% specificity, while brain MRI showed 62% sensitivity and 93% specificity (p>0.05, McNemar test). SPECT found more cortical lesions and MRI was superior in detecting white matter lesions. Sensitivity and specificity of 31 mild TBI patients were 45%, 90% for SPECT and 27%, 100% for MRI (p>0.05, McNemar test). Among 41 patients with normal brain MRI, SPECT showed 63% sensitivity (50% for mild TBI) and 88% specificity (85% for malingerers). Conclusion: Brain SPECT has a supplementary role to neuropsychological tests in the psychiatric disability evaluation of chronic TBI patients by detecting more cortical lesions than MRI.
Purpose: A prospective comparison was made between imaging with Tc-99m pertechnetate (Tc-99m) and Ioine-131 (I-131) for the detection of residual and metastatic tissue after total thyroidectomy in patients with well-differentiated thyroid carcinoma. Materials and Methods: Initially our patients had imaging with Tc-99m, followed by I-131 within 3 days. The study included 21 patients who had ablation with high dose of I-131 ranging from 100 mCi to 150 mCi. Planar and pinhole images were acquired for both Tc-99m and I-131. Diagnostic images of Tc-99m and I-131 were compared with post-therapy images. Degree of uptake on Tc-99m and I-131 images was scored by four point scale and compared. Results: The results of the Tc-99m study were: 16 of 19 studies (84%) were positive on simple planar images, but 19 of 20 studies (95%) were positive on pinhole images. Conventional I-131 diagnostic imaging on the other hand showed that all studies (100%) were positive on both planar and pinhole images. There was a significant difference in degree of uptake between Tc-99m and I-131 planar images (p<0.05). Only one case of Tc-99m scintigraphy was negative on both planar and pinhole studies (false negative). There was no distant metastasis on the therapeutic I-131 images. Conclusion: Tc-99m scan using pinhole in certain clinical situations is an alternative to the I-131 scan in detecting thyroid or lymph node metastasis prior to the first ablative treatment after thyroidectomy for well-differentiated thyroid carcinoma.
Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
The Korean Journal of Nuclear Medicine
/
v.33
no.4
/
pp.413-421
/
1999
Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.
Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.
Purpose: Transient neurological deterioration (TND) is one of the complications after extracranial-intracranial bypass surgery, and it has been assumed to be caused by postoperative transient hyperperfusion. This study was performed to evaluate the relationship between TND and preoperative and postoperative cerebral perfusion status on brain perfusion SPECT following superficial temporal artery - middle cerebral artery (STA-MCA) anastomosis surgery. Materials and Methods: A total of 60 STA-MCA anastomosis surgeries of 56 patients (mean age: $50{\pm}16$ yrs; M:F=29:27; atherosclerotic disease: 33, moyamoya disease: 27) which were done between September 2003 and July 2006 were enrolled. The resting cerebral perfusion and cerebral vascular reserve (CVR) after acetazolamide challenge were measured before and 10 days after surgery using 99mTc-ethylcysteinate dimer (ECD) SPECT. Moreover, the cerebral perfusion was measured on the third postoperative day. With the use of the statistical parametric mapping and probabilistic brain atlas, the counts for the middle cerebral artery (MCA) territory were calculated for each image, and statistical analyses were performed. Results: In 6 of 60 cases (10%), TND occurred after surgery. In all patients, the preoperative cerebral perfusion of affected MCA territory was significantly lower than that of contralateral side (p=0.002). The cerebral perfusion on the third and tenth day after surgery was significantly higher than preoperative cerebral perfusion (p=0.001, p=0.02). In TND patients, basal cerebral perfusion and CVR on preoperative SPECT were significantly lower than those of non-TND patients (p=0.01, p=0.05). Further, the increases in cerebral perfusion on the third day after surgery were significant higher than those in other patients (p=0.008). In patients with TND, the cerebral perfusion ratio of affected side to contralateral side on third postoperative day was significantly higher than that of other patients (p=0.002). However, there was no significant difference of the cerebral perfusion ratio on preoperative and tenth postoperative day between patients with TND and other patients. Conclusion: In patients with TND, relative and moderate hyperperfusion was observed in affected side after bypass surgery. These finding may help to understand the pathophysiology of TND.
Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.
Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.
Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
The Korean Journal of Nuclear Medicine Technology
/
v.19
no.1
/
pp.30-36
/
2015
Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.
To investigate a comparison of rice yield and quality between organic and conventional cultivation, study for occurrence of rice diseases carried out in rice (Oryza sativa L.) field of Noahn and Bannam region. The results obtained as following: 1) Bactericide and insecticide were applied twice and four times at Noahn and Bannam region in conventional cultivation (C.C) of rice field, respectively, it was applied twice at two region in organic cultivation (O.C). Rice strip virus, leaf blast, neck blast, sheath blight, bacterial leaf blight, rice water weevil, rice leaf folder, and plant hoppers were occurred mainly in rice field. Leaf blast, neck blast, and rice leaf folder were occurred highly at O.C compared with C.C. 2) Growth level of rice in clum and panicle length was lower at O.C than C.C. Number of panicles per hill was by 0.6 higher at O.C than C.C. Number of panicles per hill was by 0.6 higher at O.C than C.C in Noahn region. Number of spikelets per panicle, grain filling ratio, brown/rough rice ratio, and weight of 1,000 grains was lower at O.C than C.C. Number of panicles per hill was by 0.8 lower at O.C than C.C in Bannam region. Number of spikelets per panicle and grain filling ratio was higher at O.C than C.C while brown/rough rice ratio was lower at O.C. Total yield percentage of rice in O.C was level of 84% at Noahn region and 94% at Bannam region compared with C.C. 3) Head rice percentage was lower at in O.C than C.C at two region. Protein and palatability (Toyo value) were lower at O.C than C.C in Bannam region causing occurrence of neck blast and rice leaf folder by oversupply of nitrogen fertilizer. Protein, whiteness, and palatability (Toyo value) were adequate level at O.C in Noahn region by lower nitrogen fertilizer.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.