• Title/Summary/Keyword: 4절기구

Search Result 56, Processing Time 0.023 seconds

Effect of Foliar Uptake of Azoxystrobin and Kresoxim-methyl on Fungicidal Activity against Cucumber Powdery Mildew (Azoxystrobin과 Kresoxim-methyl의 오이 엽면 침투성과 오이 흰가루병 방제 효과)

  • Yu, Ju-Hyun;Choi, Gyung-Ja;Kim, Heung-Tae
    • Applied Biological Chemistry
    • /
    • v.51 no.2
    • /
    • pp.108-113
    • /
    • 2008
  • Azoxystrobin applied by aqueous WP suspension 50 mg/l was slightly absorbed into cucumber leaf in the absence of activator surfactant 24 h after spraying, but was increased to 25.7% by adding polyoxyethylene monohexadecyl ether (12 moles of ethylene oxide, CE-12) 500 mg/l. Only 4.1% of kresoxim-methyl WDG 100 mg/l in the absence of surfactant was absorbed into cucumber leaf 24 h after spraying, but was increased to 58.0% by adding polyoxyethylene monooctadecyl ether (14 moles of ethylene oxide, SE-14) 1,000 mg/l. The effect of CE-12 500 mg/l on foliar uptake of kresoxim-methyl at 50 mg/l was twice bigger than on azoxystrobin. Fungicidal activity of azoxystrobin WP against cucumber powdery mildew was marginally increased by adding surfactants to facilitate foliar uptake of azoxystrobin, so that the further increase of azoxystrobin uptake into cucumber plant by the addition of adjuvant was not a practical mean for enhancing the formulation efficacy in view of fungicidal activity. It was not possible for kresoxim-methyl to assess the adjuvant effect on the fungicidal activity in a greenhouse trial due to the vapor effect of active ingredient.

Yield Increase and Energy Saving Effect on Plastic Greenhouse Covered with Polyolefin Film (PO필름 피복 온실의 수량 증대 및 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kim, Jin Gu;Lee, Jae Han;Kang, Youn Koo;Lim, Mi Young;Kim, Hye Min
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.428-439
    • /
    • 2020
  • This study was carried out to investigate the effect of PO film on the increase of crop yield and energy saving through PO and PE film greenhouse application and comparison test. As a experimental greenhouse, two single span greenhouses (1-1 W) and two double span greenhouses (1-2 W) were used. During winter season, PO film (0.15 mm outer layer, 0.10mm inner layer) was used as a covering material of greenhouse in double layers for double-span (B15) and single-span(B21), and PE film used for double-span (B15), and single-span (B23) as a control. The experimental vegetable was tomato(Solanum lycopersicum L.) cultivated in soil and the cultivar of that was 'Happiness'. That was cultivated from December 3, 2019 to April 30, 2020. The temperature at night inside the greenhouse was maintained at 15℃, and the side and roof windows were opened to maintain 23 ~ 24℃ during the day. As a result, this study showed that the yield in single-span greenhouse(B21) covered with a PO film increased 20% and that in double-span greenhouse (B16) increased by 9% compared to the greenhouse covered with a PE film (B23, B15). Fuel consumption of the single-span greenhouse (B21) with the cover of PO film was reduced by 12.4% and that of double-span greenhouse was done by 11.5% compared to that of the PE film greenhouse (B23, B15) without any difference between them in growing state.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

The suggestion for mosquito control methods on mosquito habitat by land cover map classification (토지피복도 분류체계와 연계한 모기 서식지와 적용가능 방제법 검토)

  • Kim, Jeong-Eun;Lee, Hwang-Goo;Kim, Dong-Gun
    • Korean Journal of Environmental Biology
    • /
    • v.38 no.1
    • /
    • pp.189-196
    • /
    • 2020
  • Mosquitos serve as vectors for diseases, causing inconvenience as well as a threat to human life and health. Concern about mosquitos introducing and spreading new diseases has been intensifying. We observed a variety of mosquito habitats based on land cover classification from Korea's Ministry of Environment, and the mosquito species that could appear were classified according to the each habitat type. Finally, we suggested the best control methods for each type of habitat considering habitat characteristics and the ecological traits of mosquitos. Urban areas harbor various habitats for pests, contributing significantly to mosquito habitats. Control must be performed regarding larva and adults because various sources for habitats exist. Public mosquito control programs such as educational training, as well as information brochures can be effective in managing mosquito populations and public health. Agricultural areas show high densities of mosquito larva to lentic zones such as reservoirs, wetlands, paddy fields. So, biological control using natural predators may be effective in controlling mosquito populations. Forests are major habitats for Aedes albopctus, so physical controls should be deployed for residents living nearby, and excessive deforestation should be minimized. Other areas including aquatic ecosystems should be adopted regarding biological control using Bti (Bacillus thuringiensis var. israelensis) and chemical control for eradicating mosquitos. We classified habitats into four types of land cover patterns considering ecological traits and habitat preference, and suggest adequate control methods for each habitat type. Our suggestion can be used to positively contribute toward effective managing mosquito's density and reducing the damage to public health.

VOC/HAPs Emission Characteristics & Adsorption Evaluation for Paint Products in Busan Area (부산지역 페인트제조시설의 VOC/HAPs 배출특성 및 흡착능 평가)

  • Song, Bok-Joo;Lee, Seung-Min;Cho, Gab-Je;Cho, Jeong-Gu;You, Pyung-Jong;Kim, Gi-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.5
    • /
    • pp.316-325
    • /
    • 2012
  • In this study, we suggested adequate control technology by analyzing emission process and main chemical of VOC/HAPs generated from four paint factories in Busan area. And we estimated whether Kapok fiber, which is a natural material, can be commercially used for an absorbent by testing adsorption ability. As a result of this sturdy, above 60% of VOC/HAPs was volatilized and dispersed inside the working place without conducting control system of facilities during manufacturing paints. Concentration profile of VOC/HAPs, which is volatile naturally outside the factories, is surveyed above 70% at Toluene, Ethylbenzene, and Xylene. And a result of evaluation of odor attribution level about the component whose Odor Threshold is known, it is estimated that major cause material of A, B, C factories is Toluene and that of D factory is m/p-Xylene. And that result presented design arguments such as facilities specifications, activated carbon filling volume, and replace cycle of activated carbon as control technology. Also, that result presented emission process improvement such as adsorption of central-controlled ventilation device, installation of inlet flenge, and potable cleaning process. The rate of pollutant adsorption of Kapok fiber, which is natural material, is indicated about 91.9%, 66.7%. That result validated the possibility as replacement of activated carbon.

Ice Melting Capacity Evaluation of Applicable Materials of De-icing Fluid for High Speed Railway Rolling Stock (고속철도차량용 제빙액으로의 적용가능물질에 대한 융빙성능 평가)

  • Park, Gyoung-Won;Lee, Jun-Ku;Lee, Hong-Ki
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.384-388
    • /
    • 2019
  • In winter season, the snow and ice accretion on the bottom of the high speed railway rolling stock and boogie part has fallen at a high speed from the ballast section (gravel section for the transmission of the rolling stock load received by sleepers and fixing sleepers), causing the gravel to be scattered, thereby damaging the railway rolling stock structures and facilities. In order to solve these problems, the gravel scattering prevention net, manual de-icing, and movable hot air machine were used, but their efficiency was low. For the more efficient de-icing than ever before, an optimum material for de-icing fluid for high speed railway rolling stock was developed by evaluating the ice melting capacity, kinematic viscosity, evaporation of the material used as a chemical de-icing fluid. Four kinds of organic acid salts (sodium formate, sodium acetate, potassium formate and potassium acetate) and two different alcohols (propylene glycol, glycerol) were used as evaluation materials. Potassium formate, potassium acetate, and propylene glycol had similar ice melting capacities in the indoor test, but the propylene glycol showed the best ice melting capacity in spraying the system simulation test. This is because the kinematic viscosity of propylene glycol was 2.989029 St, which is higher than those of other materials therefore, it could stay longer on the ice and de-icing. In addition, potassium formate and potassium acetate were difficult to be used since the crystals precipitated and adversely affected the appearance of the rolling stock. The propylene glycol is the most optimum as an de-icing fluid for the high speed railway rolling stock.

Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption (방울토마토 생장부 추종 국소난방이 군락 온도분포 및 연료소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Lee, Tae Seok;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2015
  • Local heating system providing hot air locally to growing parts including shoot apex and flower cluster which were temperature-sensitive organs of cherry tomato was developed to reduce energy consumption for greenhouse heating without decline of crop growth. Growing part following local heating system was composed of double duct distributer which connected inner and outer ducts with hot air heater and winder which moved ducts up and down following growing parts with plant growth. Growing part local heating system was compared with conventional bottom duct heating system with respect to distributions of air and leaf surface temperatures according to height, growth characteristics and energy consumption. By growing part local heating, air temperature around growing part was maintained $0.9{\sim}2.0^{\circ}C$ higher than that of lower part of crop and leaf surface temperature was also stratified according to height. Investigations on crop growth characteristics and crop yield showed no statistically significant difference except for plant height between bottom duct heating and growing part local heating. As a result, the growing part local heating system consumed 23.7% less heating energy than the bottom duct heating system without decrease of crop yield.

Evaluation on Cooling Effects of Geothermal Heat Pump System in Farrowing House (지열 냉방시스템을 이용한 분만돈사의 냉방효과 분석)

  • Choi, H.C.;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.;Park, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.99-108
    • /
    • 2010
  • The principal objective of this study was to investigate the cooling effects of geothermal heat pump system (GHPS) in farrowing house. A total of 96 sows were allocated to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in summer season. During the experimental period of four weeks, the highest outside temperature observed was approximately $34.1^{\circ}C$, GHPS decrease indoor temperature of pig housing up to $30.9^{\circ}C$, but conventional pig housing was similar to outside temperature. Dust concentrations (maximum 61.4%) of particulate matter less than $10{\mu}m$ (PM 10) in GHPS-housing were lower than the conventional housing. GHPS showed no signigicant difference in carbon dioxide emission, whereas the ammonia gas concentration was significantly decreased in GHPS-housing compared to that of conventional housing. Sows in GHPS-housing showed significantly lower respiratory rate than those of the control group. GHPS did not affect hormone level, litter size and birth weight, but weaning weight of piglets was influenced by GHPS. Feed consumption of sows was significantly increased in GHPS-housing compared to the conventional hosing. These results suggest that GHPS decrease dust concentration, ammonia gas emission and indoor temperature of pig housing and may affect performance in sows and weaned piglets.

Effect of Timing of Nutrient Starvation during Transplant Production on the Growth of Runner Plants and Yield of Strawberry 'Seolhyang' (딸기 '설향' 육묘기 양분 공급 중단 시기가 자묘 생육 및 수량에 미치는 영향)

  • Kim, Dae-Young;Chae, Won Byoung;Kwak, Jung-Ho;Park, Suhyung;Cheong, Seung-Ryong;Choi, Jong Myung;Yoon, Moo Kyoung
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.421-426
    • /
    • 2013
  • This study was conducted to investigate the effects of timing of nutrient starvation during transplant production on growth of runner plants and yield of strawberry 'Seolhyang' (Fragaria ${\times}$ ananassa). Nutrient solution supply at the level of EC (electrical conductivity) 0.8 $dS{\cdot}m^{-1}$ was terminated at interval about 10 days between July 25 and September 5. As a result, the growth of above-ground part was inhibited while root growth increased when the nutrient starvation treatment had been brought forward to July 25. It also reduced the T/R ratio significantly and chlorophyll content was tended to be lower than the other treatment. In addition, it significantly promoted the budding, flowering and harvest of first flower cluster. On the other hand, the period of harvest was delayed more than two weeks when the nutrients were continuously supplied after the middle of August. An accumulated marketable fruit yield per plant until the end of January and February was 169 and 266g, respectively in the treatment of nutrient starvation on July 25, which was 71 and 12% increase, respectively, as compared with those in the treatment of September 5. Therefore, the appropriate nutrient starvation in the late season of strawberry nursery period could be expected the increase in yield and income during the winter season by promoting the flower bud differentiation as reducing the endogenous nitrate level of the plantlet.

Rhizobium meliloti Populations and Alfalfa Yields Due to Nitrogen Fertilization and Inoculation Methods at Cultivated Upland Soil (숙전(熟田)에서 질소시용(窒素施用)과 Rhizobium meliloti의 접종방법(接種方法)이 근류균(根瘤菌) 밀도(密度) 및 알팔파 수량(收量)에 미치는 영향(影響))

  • Kang, Ui-Gum;Jung, Yeun-Tae;Lee, Soo-Kwan;Ha, Ho-Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.25 no.3
    • /
    • pp.275-280
    • /
    • 1992
  • Inoculation responses of alfalfa[Medicago sativa(L.) Vernal] to Rhizobium meliloti with nitrogen fertilization were characterized by soil populations and plant yields from 1989 to 1991 at cultivated upland soil, which contained $3.1{\times}10$cells of R. meliloti/g.soil. The results obtained accordingly to fertilizing with 8Kg N/10a and differently inoculating the host such as initial and annual inoculation methods were as follows : 1. Soil populations of R. meliloti were increased more at no nitrogen fertilized condition compared to nitrogen fertilized condition to 2nd year experiment from 1st year that came up $1.6{\times}10^3$cells/g.soil, but at 3rd year the trend was reversed. Between inoculation methods, on the whole, the annual inoculation caused more populations, which were $2.0{\times}10^4$cells/g.soil in maximum number. And the populations declined after winter but recovered passing through summer season. 2. Alfalfa yields were mainly influenced by rhizobial populations rather than by fertilizing nitrogen showing a significant correlation(Y=0.36+0.287X, $r^2=0.58^{**}$) with the former. The increased extents of yields obtained by inoculation at no nitrogen and nitrogen fertilized conditions, respectively, were 66 and 10% in 1st : 13 and 20% in 2nd : 19 and 13% in 3rd year experiment with the initial inoculation, and were 66 and 10% in 1st ; 30 and 20% in 2nd : 35 and 36% in 3rd year experiment with the annual inoculation. 3. The results demonstrated the importance of inoculating, if possible, annual inoculating alfalfa to get much yields even at cultivated upland soil.

  • PDF