• Title/Summary/Keyword: 4분할 광센서

Search Result 16, Processing Time 0.032 seconds

Photostimulated Luminescence and Photoluminescence of SrCl2:Eu2+ Phosphors (SrCl2:Eu2+ 형광체의 광발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.319-326
    • /
    • 2002
  • $SrCl_2:Eu^{2+}$ phosphors were prepared by the solid phase reaction method, and their photostimulated luminescence(PSL) and photoluminescence(PL) characteristics were investigated. The PSL and PL peak of the $SrCl_2:Eu^{2+}$ phosphors are due to the $5d{\rightarrow}4f$ transition of $Eu^{2+}$ ions in phosphors. The PSL and PL spectrum obtained by the 355nm excitation was observed in $380{\sim}440\;nm$ region with the peak at 407 nm. The dose response of the PSL phosphors were linear within $2.5\;mGy{\sim}200\;mGy$ of 100 kV X-ray. The fading of the phosphors at room temperature was approximately 60% after 20 min.

Development of intrusion detection technique using fiber optic ROTDR sensor (광섬유 ROTDR 센서를 이용한 침입 탐지기법의 개발)

  • Baik, Se-Jong;Kwon, Il-Bum;Chung, Chul;Yu, Jae-Wang
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2002
  • The developing of buried fiber optic sensor with high sensitivity and broad-area detecting intruders is carried out using fiber optic ROTDR(Rayleigh Optical Time Domain Reflectometry). The sensing part was designed to be able to broad-area detect intrusion effect per optical fiber length under ground. The bending light losses in optical fibers are investigated by commercial mini ROTDR with wavelength $1.55{\mu}m$, distance range 5km, pulse width 20ns, SNR=5.7. The sensing fibers are selected as the common telecommunication fibers are the 1.5mm, 3.5 mm outer diameter, 4km each length fiber products. Experiments were investigate the characteristics of signal sensitivity according to applied intrusion weight. The relation between the applied weight and the bending loss was almost linear, and broad-area detect intrusion effects are the 2m resolution and $1.3m^2$ per optical fiber length respectively. The light loss by the applied weight on fiber was 0.17 dB/kg. that the sensitivity of the optical fiber sensor was sufficient to detect intruders passing over the buried optical fiber.

전기화학증착 방법으로 성장시간에 따라 형성한 SnO2 나노세선의 구조적 성질

  • Lee, Chang-Hun;No, Yeong-Su;Lee, Dae-Uk;Kim, Tae-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.398-398
    • /
    • 2012
  • SnO2 나노세선은 n-형 전기적 성질과 화학적인 안정성 때문에 가스센서, 투명 전극 및 태양전지와 같은 전자소자와 광소자에 널리 사용되고 있다. 화학 기상 증착, 전자빔 증착과 전기화학증착법을 사용하여 SnO2 나노세선을 제작하고 있다. 여러 가지 증착 방법중에서 전기화학증착방법은 낮은 온도와 진공 공정이 필요하지 않으며 대면적 공정이 가능하고 빠른 성장 속도로 나노구조를 효과적으로 성장할 수 있는 장점을 가지고 있다. 본 연구에서는 전기화학증착법을 이용하여 Indium Tin Oxide (ITO) 기판 위에 SnO2 나노세선 성장하고 성장시간에 따라 형성한 SnO2 나노세선의 구조적 성질을 조사하였다. SnO2 나노세선을 성장하기 위하여 D.I. water와 Entanol을 7:3의 비율로 섞은 용액을 $65^{\circ}C$로 유지하였고, 0.015 M의 Tin chloride pentahydrate ($Cl4{\cdot}Sn{\cdot}5H2O$)를 타겟 물질로 이용하였고, 0.1 M의 Potassium chloride (KCl)를 완충 물질로 사용하였다. 전기화학증착 방법을 사용하여 제작한 ITO 기판위에 성장한 SnO2 나노세선 위에 전극을 제작하고 전류-전압 특성을 측정하였다. SnO2 나노세선이 성장되는 전기화학증착 전압을 1.2 V로 고정하고, 성장시간을 15분, 30분 및 1시간으로 변화하여 SnO2 나노세선의 구조적 특성을 분석하였다. X-선회절 (X-ray diffraction; XRD) 실험 결과는 $31^{\circ}$에서 (101) 성장방향을 갖는 SnO2 나노세선이 성장함을 확인하였고, 성장 시간이 길어짐에 따라(101) 성장방향의 XRD 피크의 intensity가 증가하였다. 전기화학증착 성장 시간이 길어짐에 따라 SnO2 나노세선의 지름이 60 nm에서 150 nm로 변화하는 것을 주사전자현미경으로 관측하였다. 이 실험 결과는 전기화학증착방법을 사용하여 제작한 SnO2 나노세선의 성장 시간에 따른 구조적 특성들을 최적화하여 소자제작에 응용하는데 도움이 된다.

  • PDF

Recent Advances in 3D/4D Printed Electronics and Biomedical Applications (3D/4D 프린트된 전자기기 및 바이오메디컬 응용기술의 최근 발전)

  • Hyojun Lee;Daehoon Han
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.1-7
    • /
    • 2023
  • The ability of 3D/4D printing technology to create arbitrary 3D structures provides a greater degree of freedom in the design of printed structures. This capability has influenced the field of electronics and biomedical applications by enabling the trends of device miniaturization, customization, and personalization. Here, the current state-of-the-art knowledge of 3D printed electronics and biomedical applications with the unique and unusual properties enabled by 3D/4D printing is reviewed. Specifically, the review encompasses emerging areas involving recyclable and degradable electronics, metamaterial-based pressure sensor, fully printed portable photodetector, biocompatible and high-strength teeth, bioinspired microneedle, and transformable tube array for 3D cell culture and histology.

Computer Interface for the Disabled Using Gyro-sensors and Artificial Neural Network (자이로 센서와 인공신경망을 이용한 장애인용 컴퓨터)

  • 안용식;엄광문;김철승;허지운;나유진
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.411-419
    • /
    • 2003
  • This paper aims at developing 'gyro-mouse' which provides decent and comfortable human-computer interface that supports the usage of such software as an internet-browser in PC for the people paralyzed in upper limbs. This interface operates on information collected from head movement to get the cursor control. The interface is composed of two modules. One is hardware module in which the head horizontal and vertical angular velocities are detected and transmitted into PC. The other is a PC software that translates the received data into movement and click signals of the mouse. The ANN (artificial neural network) learns the quick nodding pattern of each user as click input so that it can provide user-friendly interface. The performance of the system was evaluated by three indices that are click recognition rate. error in cursor position control. and click rate of the moving target box. The performance result of the gyro-mouse was compared with that of the optical-mouse to assess the efficiency of the gyro-mouse. The average click recognition rate was 93%, average error in cursor position control was 1.4∼5 times of optical mouse. and the click rate with 50 pixels target box was 40%(30 clicks/min) to that of optical mouse. The click rate increased monotonously with the number of trial from 35% to 44%. The suggested system is expected to provide a new possibility to communicate with the society.

Development of PET Detector Module Measuring DOI using Multiple Reflectors (여러 반사체를 사용한 양전자방출단층촬영기기의 반응 깊이 측정 검출기 모듈 개발)

  • Kim, Neung Gyun;Kim, Gu;Kwak, Jong Hyeok;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.825-830
    • /
    • 2019
  • A detector module measuring a depth of interaction was developed using silicon photomultiplier (SiPM) and two layers of scintillation crystal array treated with multiple reflectors. When reconstructing an image based on a signal obtained by using different types of reflector of each layer, the interaction positions of scintillation pixels and gamma rays could be tracked by utilizing the feature that all scintillation pixels were recorded at different positions. The bottom layer uses a specular reflector, and the top layer uses a diffuse reflector to differently process the size of the signal obtained from the SiPM. The optical grease was used to recude the sharp refractive index change between the layers of scintillator and the SiPM. The signals obtained from the 16 SiPMs were reduced to four signals using the Anger equations, and the images were reconstructed using them. All the scintillation pixels composed of the two layers appeared in the reconstructed image, which distinguished the layer where the scintillation pixels and gamma rays interacted. If the detectors, which measure the interaction depth of two layers using different reflectors, will be applied to preclinical positron emission tomography, the degradation of spatial resolution appearing outside the field of interest could be solved.