• Title/Summary/Keyword: 4/2 SRM

Search Result 135, Processing Time 0.028 seconds

Copper Loss and Torque Ripple Minimization in Switched Reluctance Motors Considering Nonlinear and Magnetic Saturation Effects

  • Dowlatshahi, Milad;Saghaiannejad, Sayed Morteza;Ahn, Jin-Woo;Moallem, Mehdi
    • Journal of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.351-361
    • /
    • 2014
  • The discrete torque generation mechanism and inherently nonlinear magnetic characterization of switched reluctance motors lead to unacceptable torque ripples and limit the application of these motors. In this study, a phase current profiling technique and torque sharing function are proposed in consideration of magnetic saturation effects and by minimizing power loss in the commutation area between the adjacent phases. Constant torque trajectories are considered in incoming and outgoing phase current planes based on nonlinear T-i-theta curves obtained from experimental measurements. Optimum points on constant torque trajectories are selected by improving drive efficiency and minimizing copper loss in each rotor position. A novel analytic invertible function is introduced to express phase torque based on rotor position and its corresponding phase current. The optimization problem is solved by the proposed torque function, and optimum torque sharing functions are derived. A modification method is also introduced to enhance the torque ripple-free region based on simple logic rules. Compared with conventional torque sharing functions, the resultant reference current from the proposed method has less peak and effective values and exhibits lower copper loss. Experimental and simulation results from a four-phase 4 KW 8/6 SRM validate the effectiveness of the proposed method.

Fault Detection and Compensation Scheme of Switch Open-fault in VSI for Two-phase Excitation Drive (2상 여자 구동용 전압형 인버터의 스위치 개방고장 검출 및 보상 기법)

  • Lee, Kui-Jun;Park, Nam-Ju;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.74-80
    • /
    • 2007
  • This paper proposes the novel open-fault detection/isolation scheme of inverter switch in two-phase excited VSI. This scheme identify open-fault using voltage sensor at lower switches of each phase according to the operating mode. It has benefit of simple implementation, fast detection and robustness in the load so that stab of the system is improved. Also, at faulty mode, it minimizes faulty effect and makes possible continuous operation through the reconfiguration procedure applying four-switch operation. The validity of proposed fault detection scheme is verified by experimental results.

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF

A Study of $^{222}Rn\;and\;^{226}Ra$ Analysis in the Groundwater by LSC (액체섬광계수기에 의한 지하수중의 $^{222}Rn$$^{226}Ra$ 분석법 연구)

  • Woo, Hyung-Joo;Yoon, Yoon-Yeol;Cho, Soo-Young;Chun, Sang-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.275-283
    • /
    • 1995
  • PERALS(Photon Electron Rejecting Alpha Liquid Scintillation) spectrometry coupled with solvent extraction method has been set up for the analysis of $^{222}Rn\;and\;^{226}Ra$ in the groundwater. This analytical method offers low background, better energy resolution and lower quenching problem than the other techniques. By the analysis of NIST SRM 4966 $^{226}Ra$ standard, the analytical accuracy and precision were found to be 3% and 1%, respectively, and the relative standard deviation of the recovery of Rn extraction between pH2 and pH10 was 7%. Detection limits of $^{222}Rn$ and $^{226}Ra$ for 10 hours counting were counted to be $0.42 pCi/{\iota}\;and\;0.016 pCi/{\iota}$, respectively. For the test analysis of $^{222}Rn\;and\;^{226}Ra$ in the graundwater, hot spring water samples of 17 regions were analyzed. The concentration of $^{222}Rn$ were in the range of $90{\sim}5200pCi/{\iota}$ and average value was $1470pCi/{\iota}\;^{226}Ra$ concentration showed a peak value of $97.9pCi/{\iota}$ in a Kangwon region, but the average value was $1.14pCi/{\iota}$ except that region.

  • PDF

Investigation of Nanometals (Ni and Sn) in Platinum-Based Ternary Electrocatalysts for Ethanol Electro-oxidation in Membraneless Fuel Cells

  • Ponmani, K.;Kiruthika, S.;Muthukumaran, B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.95-105
    • /
    • 2015
  • In the present work, Carbon supported Pt100, Pt80Sn20, Pt80Ni20 and Pt80Sn10Ni10 electrocatalysts with different atomic ratios were prepared by ethylene glycol-reduction method to study the electro-oxidation of ethanol in membraneless fuel cell. The electrocatalysts were characterized in terms of structure, morphology and composition by using XRD, TEM and EDX techniques. Transmission electron microscopy measurements revealed a decrease in the mean particle size of the catalysts for the ternary compositions. The electrocatalytic activities of Pt100/C, Pt80Sn20/C, Pt80Ni20/C and Pt80Sn10Ni10/C catalysts for ethanol oxidation in an acid medium were investigated by cyclic voltammetry (CV) and chronoamperometry (CA). The electrochemical results showed that addition of Ni to Pt/C and Pt-Sn/C catalysts significantly shifted the onset of ethanol and CO oxidations toward lower potentials. The single membraneless ethanol fuel cell performances of the Pt80Sn10Ni10/C, Pt80Sn20/C and Pt80Ni20/C anode catalysts were evaluated at room temperature. Among the catalysts investigated, the power density obtained for Pt80Sn10Ni10/C (37.77 mW/cm2 ) catalyst was higher than that of Pt80Sn20/C (22.89 mW/cm2 ) and Pt80Ni20/C (16.77 mW/ cm2 ), using 1.0 M ethanol + 0.5 M H2SO4 as anode feed and 0.1 M sodium percarbonate + 0.5 M H2SO4 as cathode feed.

A Study on Characteristics of Wood Pellet Gasification in Two Stage Gasifier (Two Stage Gasifier에서의 우드펠릿 가스화 특성 연구)

  • Lee, Moon-Won;Choi, Sun-Yong;Kim, Lae-Hyun
    • Journal of Energy Engineering
    • /
    • v.19 no.4
    • /
    • pp.240-245
    • /
    • 2010
  • In this study, characteristics of wood pellet gasification was studied using a Two Stage Gasifier which is consisted of pyrolysis reactor and ultra high temperature reformer. The average yields of $H_2$, $CH_4$, CO, $CO_2$ were 16.7, 11.3, 37.2, 26.6 L/mim, conversion rate from biomass to gas was 65% in pyrolysis reactor and gas yields in reformer were 55.4, 0.8, 120.8, 56.8 L/mim, respectively. The hydrogen flow rate from reformer is obtained 360.1 L/hr. The most of $CH_4$ was decomposed from 12.3 to 0.3 vol.% while $H_2$ is from 18.2 to 23.7 vol.% in reformer by methane dry reforming, Boudouard reaction, oxidation and/or steam reforming. The amount of $H_2O$ generated by hydration reaction from reformer was 1111.8 g, its accelerated conversion of $CH_4$ to other products. The conversion rate from $CH_4$ to other Compounds was 97.2%. Cold gas efficiency was 53.2%.

A Simple Negative Torque Compensation Scheme for a High Speed Switched Reluctance Motor

  • Lee, Dong-Hee;Ahn, So-Yeon;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.58-66
    • /
    • 2012
  • SRMs(Switched Reluctance Motors) are much interested in high speed applications due to the mechanical robustness, simple structure and high efficiency. In spite of many advantages of SRMs, a higher torque ripple discourages the adoption of SRMs in a high speed application. This paper presents a simple negative torque of tail current compensation scheme using a modified TSF(Torque Sharing Function) for the high speed SRMs. Because of the short commutation in the high speed region, the negative torque from the tail current makes the high torque ripple. In order to reduce and compensate the negative torque from tail current, the proposed control scheme produces an additional compensating torque with a reference torque in the active phase winding. And the compensating value is dependent on the tail current of the inactive phase winding. Furthermore, the switching signals of the outgoing phase are fully turned off to restrict the extended tail current, and the torque error of the outgoing phase is compensated by the incoming phase. The proposed modified TSF control scheme is verified by the computer simulations with 30,000[rpm] high speed 4/2 SRM. The simulation and experimental results show the effectiveness of the proposed control scheme.

Measurements of the rheological properties of standard reference material 2490 using an in-line micro-Fourier rheometer

  • Smith R. S.;Glasscock J. A.
    • Korea-Australia Rheology Journal
    • /
    • v.16 no.4
    • /
    • pp.169-173
    • /
    • 2004
  • The control of the rheological properties of a fluid during processing is important and can determine the efficiency of the production in addition to the performance of the final product. The vast majority of process fluids are viscoelastic, hence an instrument that measures both the viscous and elastic properties of the material during processing would be of great practical use. However, most in-line instruments commercially available to date are only capable of measuring viscosity at a single shear rate. An in-line rheometer that measures both the viscous and elastic properties of fluids over a wide range of shear rates simultaneously has been described in a previous publication (Glasscock et at., 2003) in which the results of measurements on flowing sunflower oil were presented. Before this instrument can be used in an industrial situation, it must be demonstrated that the generated results are the same as, or bear some fixed relationship to, the results obtained by conventional off-line rheometers. To this end, the present investigation describes the measurements of a standard reference fluid, polyisobutylene dissolved in 2,6,10,14-tetramethylpentadecane, labelled SRM2490 by the National Institute of Standards and Technology (NIST) in the USA. The results obtained using the in-line rheometer show remarkably good correlation for viscosity, using a modified Cox­Merz rule, with the results supplied with the reference material from NIST.

Measurement of Heavy Metals Using Portable XRF in Children's Playing Goods (Portable XRF를 이용한 어린이 야외 놀이용품의 중금속 측정)

  • Kim, Hyung-Jin;Baek, Young Man;Jung, Kyung Hoon;Hong, Suk Youn;Heo, Hwa Jin;Seong, Jin Uk;Park, Je Chul
    • Journal of Environmental Science International
    • /
    • v.22 no.4
    • /
    • pp.471-479
    • /
    • 2013
  • The present study was conducted to judge the applicability of field quality control by children's goods manufacturers by assessing the contents of heavy metals such as Pb and Cd in outdoor play goods for children through measurement using Portable XRF and comparing the results through detailed analyses using ICP. Heavy metal contents of 711 part samples of 505 products were measured using XRF. According to the results, the ratio of products that exceeded the Pb and Cd content standards specified under the Quality Management and Safety Control of Industrial Products Act were 2.4% and 2.6%. Many products certified for self-regulated safety exceeded the standards and thus it was considered that harmful chemical material centered safety management systems would be necessary. Detailed ICP analyses of some products were compared and the results showed deviations of 0.9~80.8% from XRF results. The reasons for this are deviations in the characteristics of measured cross sections and the homogeneity of samples resulting from sample preparation methods, etc. Therefore, it is considered that field quality control will be applicable if measuring methods are efficiently established based on product characteristics and calibration curve preparation methods are established through quality control.

A Study of Moral Development and Ethical Values of the Nurse (임상 간호사의 도덕성 발달과 윤리적 가치관에 대한 연구)

  • Kim, Mee-Jeong;Kim, Myung-Hee
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.2
    • /
    • pp.337-353
    • /
    • 1999
  • This study is to provide the basic sources to develop educational data that can establish ethical values with research on the interrelation between moral development and ethical values of nurses. The subjects of this study are the convenience sample from 111 nurses working in clinical settings from 5 general hospitals located in Pusan area. The questionnairs for this study are comprised two parts: Part 1 is SRM-SF(1995) guestionnaire, and translated by Kil, 1m Ju(1997): Part 2 is the guestion papers about the ethical values, and disigned by Jung, Hee Ja. The data were collected from June lth to 31th, 1997 and analyzed by S.A.S(Statistical Analysis System) Package for frequency, percent, and Pearson's correlation coefficient. The results of the study is as the followings: 1) According to the moral development. the nurses are in the levels of Stage3 or Transition3/4, which are generally focused on the personal relations or personality. Thus, nurses are considered to need to get the stage4 of education that helps them recognize a person as a member of society. a family as an unit of society, and human life as the values of human dignity. 2) According to the ethical values, nurses have the positive ethical values of respecting the right of the patients, providing information, keeping the secret, truth. and credit of patients. But they also experience some troubles by the patients to care and the clinical situation. Thus, to overcome the problems, nurses are considered to need to get the education that establishs the right ethical values. 3) The analysis result on the interrelation between moral development level and ethical values shows as r=0.28 and p=0.003. This indicates that the interrelation between them is low. In conclusion, it is considered that the moral development level is viewed broadly from a person and family to a society, and then it can affect to the ethical values positively.

  • PDF