• Title/Summary/Keyword: 3d-scanning

Search Result 1,479, Processing Time 0.027 seconds

Relationships between the upper central incisor crown forms and degree of labial inclination, overbite, and overjet in Japanese young adults

  • Kurita, Takeshi;Mizuhashi, Fumi;Sato, Toshihide;Koide, Kaoru
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.338-343
    • /
    • 2020
  • PURPOSE. The present study aimed to investigate the relationships between the crown form of the upper central incisor and their labial inclination, overbite, and overjet. MATERIALS AND METHODS. Maxillary and mandibular casts of 169 healthy dentitions were subjected to 3D dental scanning, and analyzed using CAD software. The crown forms were divided into tapered, square, and ovoid based on the mesiodistal dimensions at 20% of the crown height to that at 40%. The degree of labial inclination of the upper central incisor was defined as the angle between the occlusal plane and the line connecting the incisal edge and tooth cervix. The incisal edges of the right upper and lower central incisor that in contact with lines parallel to the occlusal plane were used to determine the overbite and overjet. One-way ANOVA was performed to compare the labial inclination, overbite, and overjet among the crown forms. RESULTS. The crown forms were classified into three types; crown forms with a 20%/40% dimension ratio of 1.00±0.01 were defined as square, >1.01 as tapered, and <0.99 as ovoid. The labial inclination degree was the greatest in tapered and the least in square. Both overbite and overjet in tapered and ovoid were higher than those in square. CONCLUSION. Upper central incisor crown forms were related to their labial inclination, overbite, and overjet. It was suggested that the labial inclination, overbite, and overjet should be taken into consideration for the prosthetic treatment or restoring the front teeth crowns.

Effects of Schroth exercise therapy on curvature and body appearance of patients with lumbar idiopathic scoliosis

  • Lee, Hyung-Joo;Lee, Suk-Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.4
    • /
    • pp.230-237
    • /
    • 2020
  • Objective: To investigate the physical appearance and therapeutic changes that occur with the performance of Schroth exercise in patients with scoliosis. Design: Randomized controlled trial. Methods: Fifteen subjects with maximum curvature of the lumbar who were diagnosed with idiopathic scoliosis had volunteered to participate in the study. Eight subjects were included in the experimental group where they performed the Schroth Therapeutic Exercise and the other seven were included in the control group. The experimental group underwent 2 hours of weekly treatment for 12 weeks, while the control group did not during the same period based on the decisions of patients or guardians. The Mann-Whitney rank test was carried out to compare the treatment results of the two groups, and the comparison within the group was done by Wilcoxon signed-rank test. The vertebral rotation angle (VRA) was by Scoliometer, and difference of rotated and curved portion volume (DV) between both sides on the major curvature portion measured by 3D human body scanning system. Results: In the experimental group, 12 weeks of Schroth exercise therapy has significant improved in correction rate (CR) in Cobb's angle (CA), VRA, and DV between both sides on the major curvature portion (p<0.05), while significant differences were not found between the groups regarding weight bearing difference in both feet (WD) and DV (p<0.05). Conclusions: Schroth exercise performance showed significant changes in the patient's therapeutic changes (CA, VRA), but the physical appearance (DV, WD) was not significant, indicating that external changes in the treatment goal setting are more difficult goals to achieve.

Comparison of dimensional accuracy between direct-printed and thermoformed aligners

  • Koenig, Nickolas;Choi, Jin-Young;McCray, Julie;Hayes, Andrew;Schneider, Patricia;Kim, Ki Beom
    • The korean journal of orthodontics
    • /
    • v.52 no.4
    • /
    • pp.249-257
    • /
    • 2022
  • Objective: The purpose of this study was to evaluate and compare the dimensional accuracy between thermoformed and direct-printed aligners. Methods: Three types of aligners were manufactured from the same reference standard tessellation language (STL) file: thermoformed aligners were manufactured using Zendura FLXTM (n = 12) and Essix ACETM (n = 12), and direct-printed aligners were printed using Tera HarzTM TC-85DAP 3D Printer UV Resin (n = 12). The teeth were not manipulated with any tooth-moving software in this study. The samples were sprayed with an opaque scanning spray, scanned, imported to Geomagic® Control XTM metrology software, and superimposed on the reference STL file by using the best-fit alignment algorithm. Distances between the aligner meshes and the reference STL file were measured at nine anatomical landmarks. Results: Mean absolute discrepancies in the Zendura FLXTM aligners ranged from 0.076 ± 0.057 mm to 0.260 ± 0.089 mm and those in the Essix ACETM aligners ranged from 0.188 ± 0.271 mm to 0.457 ± 0.350 mm, while in the direct-printed aligners, they ranged from 0.079 ± 0.054 mm to 0.224 ± 0.041 mm. Root mean square values, representing the overall trueness, ranged from 0.209 ± 0.094 mm for Essix ACETM, 0.188 ± 0.074 mm for Zendura FLXTM, and 0.140 ± 0.020 mm for the direct-printed aligners. Conclusions: This study showed greater trueness and precision of direct-printed aligners than thermoformed aligners.

A Study on the Effect of Oyster Shell Surfase Modified with Rare Earth Coupling Agent on Eco-Friendly Bio-EPDM Foam (Rare earth coupling agent로 표면개질된 Oyster shell이 친환경 Bio-EPDM 발포체에 미치는 영향 연구)

  • Seo, Eun Ho;Lim, Sung Wook;Park, Kyung Soon;Park, Eun Young
    • Textile Coloration and Finishing
    • /
    • v.33 no.4
    • /
    • pp.317-326
    • /
    • 2021
  • In this study, we investigated for Bio-EPDM foam with oyster shell surface modified earth coupling agent. Experiments were carried out to confirm the bio-EPDM/Oyster shell foam applying content of earth coupling agent. The cure characterization were evaluated by measuring the mooney viscosity and oscillating disc rheometer (ODR). Mechanical properties such as hardness, tensile strength, elogation at break and tear strength were measured, and changes of mechanical properties were also evaluated after immersion in NaCl solution. In addition degree of volume change was measured after immersing the Bio-EPDM foam in NaCl solution and the low-temperature permanent compression set was evaluated at 4℃. To evaluate the low-temperature characteristics of Bio-EPDM/Oyster shell, the glass transition temperature was measured using Differential Scanning Calorimeter (DSC). As a result as the content of the earth coupling agent increased up to 3phr, the crosslinking density and mooney viscosity increased, and the mechanical properties and low-temperature permanent compression set improved, but from 4phr, it was rather decreased. The change in the glass transition temperature was insignificant, and the foam cell appeared to be uniform when the earth coupling agent was applied.

Conservation Status Diagnosis of Mural Painting in Geungnakjeon Hall of Daewonsa Temple, Boseong: Avalokitesvara Bodhisattva Mural and Buddhist Monk Bodhidharma Mural

  • Lee, Hwa Soo;Eom, Tae Ho;Jee, Bong Goo;Yi, Sun Jo;Yu, Yeong Gyeong;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.314-326
    • /
    • 2022
  • Investigation of conservation status, optical survey, infrared thermography, and ultrasonic examination were performed on Avalokitesvara Bodhisattva mural and Buddhist Monk Bodhidharma mural to determine the conservation status and physical properties. As a result of investigation of conservation status, the types of damage are largely divided into the wall and finishing layer damage, painting layer degradation, damage due to restoration materials, stains and contamination, and biological damage. As a result of the optical survey, drawing, stains, and repainted site were confirmed. Result of the infrared thermography, the delamination of the finishing layer was confirmed, and some locations and shapes of the wooden lath inside the wall were identified. The result of the 3D scanning, the deviation, and the separation of the wall was confirmed. As a result of ultrasonic examination, it was confirmed that the physical properties of the mural were identified and the ultrasonic speed was relatively low due to physical damage such as delamination and exfoliation of the finishing layer and cracking. Ultrasonic speed values were also high in some wall cracks or delamination, and it was confirmed by the infrared thermography results that the wooden lath inside the wall was located in those parts. It was possible to understand that the wooden lath inside the walls affects the ultrasonic speed during the ultrasonic examination. Therefore, management through periodic inspection of the relevant elements is necessary, and a countermeasure for damage that may occur in the future should be prepared along with intensive monitoring of the major damage identified in this diagnosis result.

Application of Finite Element Analysis for Structural Stability Evaluation of Modern and Contemporary Sculptures: 'Eve 58-1' by Man Lin Choi

  • Kwon, Hee Hong;Shin, Jeong Ah;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.38 no.4
    • /
    • pp.277-288
    • /
    • 2022
  • 'Eve 58-1', the subject of this study is a statue made of plaster and its structural stability was evaluated by utilizing the CAE program in order to prevent the risk of damage arising from impact and vibration that are generated during the packaging and transportation process given its material characteristics. CAE is an abbreviation for Computer Applied Engineering for realization by predicting changes at the time of application of virtual physical energy. It is applied by reflecting the physical property conditions and each boundary condition of plaster, and the digital images of the internal and external structure of the work were acquired through 3D scanning and CT analysis for interpretation by executing finite element modeling. When acceleration is applied to the work in the direction of its own weight, the left-right side and the front-rear side, it was possible to confirm a maximum displacement value of 15.24 mm in the head section of the front-rear side direction that has been tilted by approximately 27° from the Y-axis and the largest stress value of 12.46 MPa was at the left ankle section. The corresponding results confirmed that the left ankle section is the most vulnerable area and the section for which precautions need to be exercised and supplemented at the time of transporting the work by means of objective values.

Heat Dissipation Trends in Semiconductors and Electronic Packaging (반도체 및 전자패키지의 방열기술 동향)

  • S.H. Moon;K.S. Choi;Y.S. Eom;H.G. Yun;J.H. Joo;G.M. Choi;J.H. Shin
    • Electronics and Telecommunications Trends
    • /
    • v.38 no.6
    • /
    • pp.41-51
    • /
    • 2023
  • Heat dissipation technology for semiconductors and electronic packaging has a substantial impact on performance and lifespan, but efficient heat dissipation is currently facing limited improvement. Owing to the high integration density in electronic packaging, heat dissipation components must become thinner and increase their performance. Therefore, heat dissipation materials are being devised considering conductive heat transfer, carbon-based directional thermal conductivity improvements, functional heat dissipation composite materials with added fillers, and liquid-metal thermal interface materials. Additionally, in heat dissipation structure design, 3D printing-based complex heat dissipation fins, packages that expand the heat dissipation area, chip embedded structures that minimize contact thermal resistance, differential scanning calorimetry structures, and through-silicon-via technologies and their replacement technologies are being actively developed. Regarding dry cooling using single-phase and phase-change heat transfer, technologies for improving the vapor chamber performance and structural diversification are being investigated along with the miniaturization of heat pipes and high-performance capillary wicks. Meanwhile, in wet cooling with high heat flux, technologies for designing and manufacturing miniaturized flow paths, heat dissipating materials within flow paths, increasing heat dissipation area, and reducing pressure drops are being developed. We also analyze the development of direct cooling and immersion cooling technologies, which are gradually expanding to achieve near-junction cooling.

Purification of Oat ${\beta}-Glucan$ by ${\alpha}-Amlyase$ Treatment and Characterization of Its Physicochemical Properties (귀리 ${\beta}-glucan$${\alpha}-amlyase$를 이용한 정제와 이화학적 특성)

  • Park, Hee-Joeng;Kang, Tae-Su;Lee, Hee-Bong;Kim, Kwang-Yup;Jang, Keum-Il;Noh, Young-Hee;Jeong, Heon-Sang
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.776-782
    • /
    • 2005
  • The effects of purification using ${\alpha}-amlyase$ (Termamyl 120L) on physicochemical properties of ${\beta}-glucan$ from oat bran were studied. Four fractions were selected as fraction A ($55^{\circ}C$, 15%, pH 6), fraction B ($45^{\circ}C$, 15%, pH 6), fraction C ($50^{\circ}C$, 0%, pH 7), and fraction D ($50^{\circ}C$, 10%, pH 5) from the result of physiological test, and three consecutive subfractions were obtained by repeated ${\alpha}-amlyase$ treatments on the each fractions. The contents of ${\beta}-glucan$, protein, and ash after purification were in 81.4-88.2%, 4.1-6.3% and 2.6-6.2%, respectively. The apparent viscosities of purified ${\beta}-glucan$ aqueous solutions were similar to those of hydroxy methyl cellulose. Glucose was a major monosaccharide of ${\beta}-glucan$ extracts, and xylose and arabinose were also detected as minor constituents on TLC. The average molecular weight ranged $2.0{\times}10^6-5.1{\times}10^6$ and was decreased after purification. From the result of the differential scanning calorimetry, the melting point ranged $130-140^{\circ}C$ with purification step and thermal transition enthalpy was increased. The ratio of ${\beta}-(1{\rightarrow}3)\;to\;{\beta}-(1{\rightarrow}4) $ linkages were 1:2.22-1:2.52, and increased up to 1:5.50 after purification.

Effect of additional coating of bonding resin on the microtensile bond strength of self-etching adhesives to dentin (접착레진의 추가도포가 자가부식형 접착제의 상아질에 대한 미세인장접착강도에 미치는 영향)

  • Jung, Moon-Kyung;Cho, Byeong-Hoon;Son, Ho-Hyun;Um, Chung-Moon;Han, Young-Chul;Choung, Sae-Joon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.103-112
    • /
    • 2006
  • This study investigated the hypothesis that the dentin bond strength of self-etching adhesive (SEA) might be improved by applying additional layer of bonding resin that might alleviate the pH difference between the SEA and the restorative composite resin. Two SEAs were used in this study; Experimental SEA (Exp, pH: 1.96) and Adper Prompt (AP, 3M ESPE, USA, pH: 1.0) In the control groups they were applied with two sequential coats In the experimental groups, after applying the forst coat of assigned SEAs, the D/E bonding resin of All-Bond 2 (Bisco Inc., USA, pH: 6.9) was applied as the intermediate adhesive. Z-250 (3M ESPE, USA) composite resin was built-up in order to prepare hourglass-shaped specimens . The microtensile bond strength (MTBS) was measured and the effect of the Intermediate layer on the bond strength was analyzed for each SEA using t-test. The fracture mode of each specimen was inspected using stereomicroscope and Field Emission Scanning Electron Microscope (FE-SEM). When D/E bonding resin was applied as the second coat, MTBS was significantly higher than that of the control groups . The incidence of the failure between the adhesive and the composite or between the adhesive and dentin decreased and that of the failure within the adhesive layer increased. According to the results , applying the bonding resin of neutral pH can increase the bond strength of SEAs by alleviating the difference in acidity between the SEA and restorative composite resin.

The effect of contamination on bonding of orthodontic brackets with a self-etching prirneriadhesive (Self-etching primer/adhesive를 사용한 교정용 브라켓의 접착시 오염이 전단결합강도에 미치는 영향)

  • Kim, Yu-Shin;Lee, Hyung-Soon;Lee, Hyun-Jung;Jeon, Young-Mi;Kim, Jong-Ghee
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.439-447
    • /
    • 2004
  • The purpose of this study was to investigate the influence of water, saliva and blood contamination on the bonding strength of metal brackets with a self-etching primer/adhesive to enamel. Ninety-six extracted human teeth were divided into four groups. The brackets were bonded to enamel with a self- etching primer (3M/Unitek Dental Products. Monorovia California) according to one of four protocols. The teeth were bonded in a dry condition (group D) or in contamination with distilled water (group W), artificial saliva (group S). or fresh human blood (group B) Shear bond strengths were tested using an Instron Universal testing machine. After debonding. bracket and tooth surfaces were examined with a stereomicroscope. In each group, four samples were selected and examined with a Scanning electron microscope of the prepared enamel surface and resin-enamel interlace. The results obtained were summarized as follows: Shear bond Strength if group D $(15.22{\pm}2.86MPa)$ and W $(15.20{\pm}3.85 MPa)$ Were higher than in group B$(12.56{\pm}2.94MPa)$ (p<0.05). There were no statistical differences in the shear bond strengths between groups D. W and S (p>0.05). There was a tendency to have less residual adhesive remaining on the enamel surfaces of group B than group D. The SEW morphology of group D and W showed a more roughened etching pattern than group S and B. Water or saliva contamination on bending of orthodontic brackets with Transbond plus self etching primer had almost no influence on bond strength In this study, the blood contaminated group showed the lowest bond strength, but it was above the clinically acceptable bond strength (5.9-7.8 MPa, Reynold, 1975). The results of this study suggest that acceptable clinical bond strengths can be obtained in wet conditions when self-etching adhesives are used.