• 제목/요약/키워드: 3T MRI System

검색결과 196건 처리시간 0.029초

Preparation of Chitosan-coated Magnetite Nanoparticles by Sonochemical Method for MRI Contrast Agent

  • Cho, Jun-Hee;Ko, Sang-Gil;Ahn, Yang-Kyu;Choi, Eun-Jung
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.124-128
    • /
    • 2009
  • Magnetic nanoparticles were synthesized by using the sonochemical method with oleic acid as a surfactant. The average size of the magnetite nanoparticles was controlled by varying the ratio R=[$H_2O$]/[surfactant] in the range of 2 to 9 nm. To prepare chitosan-coated magnetite nanoparticles, chitosan solution was added to a magnetite colloid suspension under ultrasonication at room temperature for 20 min. The chitosan-coated magnetite nanoparticles were characterized by several techniques. Atomic force microscopy (AFM) was used to image the chitosan-coated nanoparticles. Magnetic hysteresis measurement was performed by using a superconducting quantum interference device (SQUID) magnetometer to investigate the magnetic properties of the magnetite nanoparticles and the chitosan-coated magnetite nanoparticles. The SQUID measurements revealed the superparamagnetism of both nanoparticles. The T1- and T2-weighted MR images of these chitosan-coated magnetite colloidal suspensions were obtained with a 4.7 T magnetic resonance imaging (MRI) system. The chitosancoated magnetite colloidal suspensions exhibited enhanced MRI contrasts in vitro.

삼차원 자기공명영상법의 뇌 구조 영상을 위한 최적화 연구: 센스인자 변화에 따른 신호변화 평가 (Optimizations of 3D MRI Techniques in Brain by Evaluating SENSE Factors)

  • 박명환;이진완;이강원;류창우;장건호
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.161-170
    • /
    • 2009
  • 목적 : 평행영상(Parallel imaging)기법의 개발로 긴 촬영시간 때문에 종종 사용되지 못하던 삼차원 영상기법이 최근 들어 환자 병을 진단하는데 새로이 사용되고 있다. 이 연구의 목적은 최근에 뇌 영상에서 개발되어 이용되고 있는 삼차원 자기공명영상을 사람의 뇌에서 짧은 시간 내에 얻을 수 있도록 2차원 평행영상 기법을 사용한 최적화 방법을 연구하는데 있다. 대상 및 방법 : 검사 장비는 3.0T 자기공명영상장치를 이용하였으며 8-채널 SENSE(sensitivity encoding) 머리 코일을 이용하였다. 팬텀 및 3명의 사람 머리에서 영상을 얻었다. 세 가지의 삼차원 영상법인 3D T1WI, 3D T2WI 및 3D FLAIR 영상 방법에 대하여 평행인자(SENSE factor)의 변화에 따른 팬텀 영상을 얻었다. 각각의 영상법에서 영상획득에 적당한 SENSE 인자를 찾기 위해 Phase encoding 방향과 Slice encoding 방향을 조합한 SENSE 인자를 변화시키면서 영상을 얻었다. 영상분석을 위하여 특정영역(ROI)를 설정한 후에 신호대 잡음비 (Signal-to-noise ratio, SNR), 감소분율(Percent Signal Reduction Rate, %R), 대조도(contrast-to-noise ratio, CNR)를 계산하였다. 결과 : 팬텀을 이용한 SENSE 인자 변화에 따른 SNR 및 %R 값의 변화 결과 3D T1WI 방법에서 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우 약 0.2%의 신호 감소가 나타났고 영상시간은 5분 이내였다. 3D T2WI 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 총 3인 경우에 약 1.0% 신호 감소가 나타났고 영상 시간은 약 5분 이내였다. 3D FLAIR 방법의 경우 SENSE 인자를 사용한 것들 중에서 SENSE 인자를 4를 사용한 경우에 약 0.2% 신호 감소가 나타났고 영상시간은 약 6분이었다. 사람을 대상으로 할 경우 3D T1W 및 3D T2W영상에서 SNR 및 CNR은 SENSE 인자를 3으로 한 경우에서 SENSE 인자를 4로 한 경우 보다 높게 나타났다. 3D FALIR 영상의 경우 CNR은 SENSE 4에서는 SENSE 3에 비하여 낮았다. 결론 : 본 연구에서는 3가지 3차원 영상법을 실제 임상적용이 가능한 시간 영역에서 SENSE 인자를 변화 시키면서 치적의 영상을 얻도록 하는 연구를 실시한 결과 SNR 감소를 최소화 하면서 영상획득 시간을 약 5분에서 6분 정도 소요되는 2차원 SENSE 인자를 찾았다. 이를 뇌 영상에 적용하였을 경우 SENSE 인자를 적용하지 않은 경우와 비교하면 신호 감소는 최소화 하면서 영상의 질은 큰 영향을 주지 않은 것으로 나타났다. 3D T1W및 3D T2W는 SENSE 인자를 3으로 3D FLAIR인자는 SENSE 인자를 4로 하는 것이 환자를 대상으로 한 뇌 영상에 적합하다고 생각된다. 앞으로는 이들 영상법이 뇌 영상뿐만 아니라 다른 영역의 영상에 적용을 위한 최적화가 필요하다고 생각된다.

  • PDF

b0 Dependent Neuronal Activation in the Diffusion-Based Functional MRI

  • Kim, Hyug-Gi;Jahng, Geon-Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제30권1호
    • /
    • pp.22-31
    • /
    • 2019
  • Purpose: To develop a new diffusion-based functional MRI (fMRI) sequence to generate apparent diffusion coefficient (ADC) maps in single excitation and evaluate the contribution of b0 signal on neuronal changes. Materials and Methods: A diffusion-based fMRI sequence was designed with single measurement that can acquire images of three directions at a time, obtaining $b=0s/mm^2$ during the first baseline condition (b0_b), followed by 107 diffusion-weighted imaging (DWI) with $b=600s/mm^2$ during the baseline and visual stimulation conditions, and another $b=0s/mm^2$ during the last activation condition (b0_a). ADC was mapped in three different ways: 1) using b0_b (ADC_b) for all time points, 2) using b0_a (ADC_a) for all time points, and 3) using b0_b and b0_a (ADC_ba) for baseline and stimulation scans, respectively. The fMRI studies were conducted on the brains of 16 young healthy volunteers using visual stimulations in a 3T MRI system. In addition, the blood oxygen level dependent (BOLD) fMRI was also acquired to compare it with diffusion-based fMRI. A sample t-test was used to investigate the voxel-wise average between the subjects. Results: The BOLD data consisted of only activated voxels. However, ADC_ba data was observed in both deactivated and activated voxels. There were no statistically significant activated or deactivated voxels for DWI, ADC_b, and ADC_a. Conclusions: With the new sequence, neuronal activations can be mapped with visual stimulation as compared to the baseline condition in several areas in the brain. We showed that ADC should be mapped using both DWI and b0 images acquired with the same conditions.

뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성 (Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2)

  • 이세지;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.51-57
    • /
    • 2016
  • 뇌 자기공명영상(Magnetic Resornance Imaging; MRI)에서 검사 중 발생되는 소음을 줄이기 위한 기법으로 경사 파형을 변경한 Quiet $T_2$-weighted Turbo Spin-Echo(이하 Q-$T_2$)와 일반적으로 사용되는 $T_2$-weighted Turbo Spin-Echo(이하 $T_2$) 영상의 소음수준 및 영상의 질을 비교하여 그 유용성을 알아보고자 하였다. 3.0T MR 기기로 뇌 MR 검사를 받은 60명(남자 29명, 여자 31명, 평균 연령 60.1세)의 환자를 대상으로 하였다. Q-$T_2$$T_2$ 각각의 영상에서 소음 및 심박동수를 측정하였다. 정량적 분석은 Q-$T_2$$T_2$의 SNR, CNR, SIR 값을 측정한 뒤 독립표본 T검정을 이용하여 통계적 분석을 하였다. 정성적 분석은 Q-$T_2$$T_2$의 전체적인 영상의 질에 대하여 육안으로 평가하였다. 평가는 5점 척도로서 우수(excellent) 5점, 양호(good) 4점, 보통(fair) 3점, 불량(poor) 2점, 평가불가(unacceptable) 1점으로 평가하였다. Q-$T_2$$T_2$ 검사 중 평균소음과 peak소음은 Q-$T_2$가 기존 $T_2$에 비해 각각 $15dB_A$, $10dB_A$ 감소하였다. 또한 각각의 검사 중 120초 동안 심박동수의 평균값은 Q-$T_2$에서 더 낮은 값으로 나타났지만 통계적인 유의성은 없었다. 정량적 분석의 결과 CNR과 SIR은 유의한 차이가 없었으며, SNR은 Q-$T_2$가 더 낮은 평균값을 보임으로서 유의한 차이를 보였다(p<0.05). 정성적 분석은 59개의 Q-$T_2$$T_2$ 영상의 질이 동일하게 우수(excellent) 5점으로 평가되었으며, 1개의 영상에서 모션 아티팩트로 인해 양호(good) 4점으로 평가되었다. Q-$T_2$는 기존의 $T_2$와 같이 검사시간 및 진단의 정확도는 동일하지만 소음을 효과적으로 감소시킬 수 있으며, 이로인하여 환자 편의를 향상시킬 수 있을 것으로 사료된다.

Assessment of Malignancy in Brain Tumors by 3T MR Spectroscopy

  • 최보영;전신수;김범수;이재문;정성택;안창범;오창현;김선일;이형구
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2003년도 제8차 학술대회 초록집
    • /
    • pp.84-84
    • /
    • 2003
  • Purpose: To assess clinical proton MR spectroscopy (MRS) as a noninvasive method for evaluating tumor malignancy at 3T high field system. Materials and methods: Using 3T MRI/MRS system, localized water-suppressed single-voxel technique in patients with brain tumors was employed to evaluate spectra with peaks of N-acetyl aspartate (NAA), choline-containing compounds (Cho), creatine/phosphocreatine (Cr) and lactate. On the basis of Cr, these peak areas were quantificated as a relative ratio.

  • PDF

음릉천(陰陵泉)(Sp9)의 전침자극(電鍼刺戟)이 functional MRI상 뇌활성(腦活性) 변화(變化)에 미치는 영향(影響) (A fMRI study on the cerebral activity induced by Electro-acupuncture on Sp9(Yinlingquan))

  • 김정호;이현;임윤경;홍권의;이병렬;김연진
    • Journal of Acupuncture Research
    • /
    • 제20권4호
    • /
    • pp.114-133
    • /
    • 2003
  • Objective : The meridian theory in oriental medicine explains that Sp9(Yinlingquan) has been considered very important for gynecological disorders, spleen and stomach disorders, and water metabolic disorders. Functional MRI is the best method of showing the evidences of the effect of the Electro-acupuncture treatment through scientific methods. On this supposition, Electro-acupuncture stimulation on Sp9(Yinlingquan) was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). Methods : Electro-acupuncture stimulation on Sp9(Yinlingquan), the experiment was carried out on six healthy volunteers, using the gradient echo sequence with the 3.0T whole-body MRI system(ISOL). After the needle insertion on right Sp9(Yinlingquan), 2Hz of electric stimulation was given for 30 seconds, repeated five times, with 30 seconds' intervals. The Image analysis including motion correction, talairach transformation, and smoothing was done using SPM99. Results : The electro-acupuncture stimulation on Sp9(Yinlingquan) activates Brodmann Area 13, 19, 22, 39, 40, 47 which may be the central pathways of the electro-acupuncture stimulation on Sp9(Yinlingquan). We also hypothesize that those brain areas may be directly or indirectly related with the mechanism of the effect of electro-acupuncture stimulation on Sp9(Yinlingquan).

  • PDF

복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교 (Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.367-373
    • /
    • 2016
  • 본 연구의 목적은 복부 자기공명영상에서 주로 적용되고 있는 4 종류의 펄스시퀀스를 중심으로 1.5 T 와 3.0 T 기기의 자기장의 차이로 나타나는 자기장의 속성 및 인공물 발생 차이를 비교하기 위해 분석을 하였다. PACS network로 전송된 총 500 명의 데이터를 정량적으로 SNR 값을 분석하였고, MSA, CSA, DA을 3 단계로 구분하여 정성적 평가를 하였다. 정량적 평가에서 SNR 값은 1.5 T 값 보다 의미 있는 결과로 높은 값을 얻었지만(p<0.05), 영상의 인공물이 발생하여 영상의 질을 저하시키는 요인도 있었다(p<0.05). 1.5 T는 3.0 T 보다 인공물 발생이 적어 3.0 T 만큼에 영상의 질을 보상 할 수가 있었다(0.05). 결론적으로, 이러한 결과를 토대로 자기장의 차이에 따라 발생되는 자기장의 속성 및 인공물 발생 차이를 파악 할 수 있었으며 이에 따른 대처방안을 제공할 수 있었다. 향후 임상현장에서 두 기기를 이용하여 복부 자기공명영상을 검사 할 때 환자를 직접 검사하는 MRI 사용자에게 가이드라인이 될 것이다.

Brain Activation Pattern and Functional Connectivity Network during Experimental Design on the Biological Phenomena

  • Lee, Il-Sun;Lee, Jun-Ki;Kwon, Yong-Ju
    • 한국과학교육학회지
    • /
    • 제29권3호
    • /
    • pp.348-358
    • /
    • 2009
  • The purpose of this study was to investigate brain activation pattern and functional connectivity network during experimental design on the biological phenomena. Twenty six right-handed healthy science teachers volunteered to be in the present study. To investigate participants' brain activities during the tasks, 3.0T fMRI system with the block experimental-design was used to measure BOLD signals of their brain and SPM2 software package was applied to analyze the acquired initial image data from the fMRI system. According to the analyzed data, superior, middle and inferior frontal gyrus, superior and inferior parietal lobule, fusiform gyrus, lingual gyrus, and bilateral cerebellum were significantly activated during participants' carrying-out experimental design. The network model was consisting of six nodes (ROIs) and its six connections. These results suggested the notion that the activation and connections of these regions mean that experimental design process couldn't succeed just a memory retrieval process. These results enable the scientific experimental design process to be examined from the cognitive neuroscience perspective, and may be used as a basis for developing a teaching-learning program for scientific experimental design such as brain-based science education curriculum.

성인의 악하부에 발생한 낭성 림프관종 (Cystic lymphangioma in the submandibular triangle in the adult)

  • 김은경;한원정;김상준
    • Imaging Science in Dentistry
    • /
    • 제31권3호
    • /
    • pp.175-179
    • /
    • 2001
  • Cystic lymphangioma is an uncommon benign developmental tumor of the lymphatic system, seen rarely in adults. A 23-year-old man visited DKUDH complaining of the painless swelling in the right submandibular area. It was reported that swelling had increased since 5 months ago. Clinically, fltriangle uctuant and mobile mass was palpated at the right submandibular area. CT scan showed a large, well-defined, homogenous low density mass, measuring 5.0 × 2.5 × 4.0 cm. T1W MRI scan demonstrated a large, multiseptated homogenous low signal mass with septum and rim enhancement. Proton-density and T2W MRI scan showed mass of high signal intensity. MRI scan was able to delineate better the enhanced multi septation and extent of the lesion. Histopathologically, a lobulated cystic mass lined by a layer of flattened endothelium was observed.

  • PDF

Development of Quadrature Detection Surface Coil for Functional Magnetic Resonance Imaging at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.363-364
    • /
    • 2002
  • We describe quadrature type surface coil for functional magnetic resonance imaging at 3T MRI system. The coil consisted of two coplanar resonators and was used as both transmitter and receiver. The signal-to-noise ratio (SNR) of the coil was compared with that of a standard birdcage head coil. Visual cortex activation on normal subjects using LED flicker was performed. The SNR of surface coil was found to be better than that of the conventional head coil.

  • PDF